Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0037940_Regional Office Historical File Pre 2018
North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary August 13, 2015 Mr. Steve Hoots, Construction Manager Childress Klein Properties 2800 One Wells Fargo Center Charlotte, NC 28202 Subject: Permit No.WQ0037940 Rivergate office Phase 1 Wastewater Collection System Extension Permit Mecklenburg County Dear Mr. Hoots: In accordance with your application received July 30, 2015, we are forwarding herewith Permit No.WQ0037940 dated August 13, 2015, to Childress Klein Properties (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. if any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. Mooresville Regional Office 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Phone: 704-663-1699 \ Fax 704-663-6040 \ Customer service 1-877-623-6748 Internet: www.ncwaterqualitv.org An Equal Opportunity \ Affirmative Action Employer— Made in part by recycled paper Childress Klein Properties Permit No.WQ0037940 Ifyou need additional information concerning this matter, please contact Barry Love at (704) 235-2143 or via e-mail at barry.love@ncdenr.gov. for S.Jay Zimmerman, P.G. Director, Division ofWater Resources, 0CDENR byMichael Parker, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division ofWater Resources, NCQENR cc: Kevin S.Caldwell, PE.(electronic copy) Barbara Gross (electronic copy) Tommy Rowland (electronic copy) Regional Office Files Water Resources Central Files Page 2 of 8 NCDENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Childress Klein Properties Mecklenburg County for the construction and operation of approximately 371 linear feet of 8-inch gravity sewer to serve a 10 employee office space as part of the Rivergate Office Phase 1 project, and the discharge of 250 GPD of collected domestic wastewater into the Charlotte Water existing sewerage system, pursuant to the application received July,30, 2015, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the ecified conditions and limitations cont.' • - . therein. for S. Jay Zimmerman, P.G. Director, Division of Water Resources, NCDENR By Authority of The Environmental Management Commission &? Permit Number: WQ0037940 Permit Issued: August 13, 2015 Page 3 of 8 SUPPLEMENT ��� �������K7� ������ �A���� ^�� PERMIT COVER Childress Klein Properties is hereby authorized to: Construct, and then operate upon mertifcatioU the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water McAlpine Creek Wastewater Treatment Facility inaccordance with Permit NumherNCU0Z497O' Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A N[AC ZT; the Division's Gravity Sewer Minimum Design Criteria adopted March 4, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Forme Mains adopted June I, ZOOV as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. it shall be the Permittee"s responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below, 1. SPECIAL CONDITIONS 1. This permit shall become voidable unless the agreement between Childress Klein Properties and Charlotte Water for the collection and final treatment ofwastewater is in full force and effect, [154 2. No flow in excess of the quantity permitted herein, 250 GPD shall be mace tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted toand approved bythe Division. [I5ANCACO2TD304(b)] 11. STANDARD CONDITIONS l. This permit is not transferable, In the event there is a desire for the wastewater collection facilities tochange ownership, orthere |saname change of the Pcmoittee,aformal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials asmay beappropriate. The approval ofthis request shall beconsidered ooits merits and may ormay not beapproved. [l6AWCAC0ZT'UIO4;G.S143-2IS1(d3)] 1 This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; lS4 NCA[ 2T; the Division's Gravity 3evvnr Minimum Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting ofPump Stations and Force Mains adopted June 1, 2003as applicable, and other supporting materials unless specifically mentioned herein. (15A NCAC 02T.0110] This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting, data. [15A NCAC 02T .01101 4. The wastewater collection facilities shall beproperly maintained and operated atall times, The Page 4 of 8 operation and maintenance of these facilities as required by 15A NCAC 2T .0403. 1f an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure, due to known or unknown reasons, that renders the fad|hY incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage orbreakage, etz.;or b. Any SSOand/or spill over l,OOQgallons; or r. Any 5GOand/or spill, regardless ofvolume, that reaches surface water Voice nnaO messages or faxed information is permissible, but this shall not he considered as the initial verbal report. QwedMoma and spills occurring outside nnnna| business hours may also he reported to the Division of Emergency Management attelephone nurnber(8O0) 858-0368nr(819) 733-3300 Persons reporting any ofthe above occurrences shall file a spillreport bycompleting and submitting Part | of Fnnn CS-63O (or the most current Dk/|dom approved form) within five days 6m1|mm/ing first knowledge ofthe occurrence. This report must outline the actions taken orproposed tobetaken tnensure that the problem does not recur. Part ||ofForm CS,-SS0(or the most current Division approved form) can also be completed to show that the 6SO was beyond control. [6.l 143' 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled xm as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater tuthe surface waters ofthe State. [15AN[AC 02T.0108(b)] 7. Upon completion of construction and prior to operation of these, permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents tothe address provided onthe form. Acomplete cerLificadun is one where the form is fully executed and the supporting documents are provided as applicable. Any vxastewaterOm*v made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permit1eetoappropriate enforcement actions. If the permit is issued to private entity with an Operational Agreement, then a copy of the Articles of Incorporation, DecLarmtio nantsyRestrictions, and Bylaws that have been appropriately filed with the applicable Count/o Register of Deeds mffica shall be submitted with the certification. Acomp|ete certification isone where the form Usfully executed and the supporting documents are provided asapplicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (mbm & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans oron digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush |ovv points in force mains with a pump cycle, and downstream sewer capacity analysis. it portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stndqnn^ storage capacities and the rotation schedule of the portable power source or pump, include travel bonefrarnex, shall be provided. Page 6 of 8 c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and, increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained- in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions,. the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page 7 of 8 FAISTTRACK, SEWER ENGINEERING CERTIFICATION Childress Klein Properties WQ0037940 RiverQateOffice Phase 1 August l3'Z01S This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Regional Supervisor, Water [}ua|h» Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection systern extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the PennNtee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until afinal certification isreceived. AFinal Certification shall beacomplete set ofrecord drawings and design calculations regardless ofwhether partials have been submitted. PERMITTEE'S CERTIFICATION [ the undersigned agent for the Pennittee,hereby, state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the permittee,and the Pemnittee is prepared to operate 8.maintain the wastewater collection system permitted herein o, portiomsthereof. Printed Name, Title Signature Date ENGmNEsu'SKIERIIFIC*T@0IN i _ _ as duly registered Professional E ineerin the State ofNorth Carolina, having been authorized to observe ([ i periodically, [] oveeWy, | | full dmm) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the bestof my ab||iti es, due oawa and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC UZl; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted K4arch4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting ofPump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: [:] Final | | Partial (include description) Certification Comments/Qualifiers (attach ifnecessmm): NC DWR — Water Quality Regional Operations Section 610 East Center Avenue, Suite 301, Mooresville, NC 28115 z 0 z z 0 0 0 CL /, la. USE THE TAB KEY TO MOVE FROM HELD TO FIELD Application Number: (to be completed by DWR) OwneriPermittee: Childress Klein Preperties Full Legal Name (company, municipality, HOA, utility, lb. Steve Hoots. Construction Manager Signing Official Name and Title (Please review 15.A NCAC 2T .0106 (b) for authorized signing officials) lc The legal entity who will own this system is: RECEIVED/NCDENRIDWR O Individual E Federal 0 Municipality 0 State/County 0 Private Partnership rl Corporation 0 Other (specify 0 2' ld. 2800 One Wells Fargo Center le, Charlotte Mailing Address if, NC State 1 h 704-342-9000 Telephone i„ 704-342-9039 Facsimile City wOPOS 1g, 28202 MOORESVILI. E qEGIONAL OFFICt - Zip Code 1j. steve,hoots@childresskiein.corn E-mail 2, Project (Facility) Information: 2a, Riveraate Office Phase 1 2b. Mecklenburg Brief Project Name (permit will refer to this name) 3. Contact Person: 3a: Scott Gregory, Project Designer Name and Affiliation of Someone Who Can Answer Qu 3b. 704-941-2244 Phone Number County Where Proje.ct. is Located stions About this Application 3c, sgrega ea ciencegroukcom E-mail 1 Project is 0 New 0 Modification (of an existing permit) If Modification, Permit No,: 2. Owner is El Public (skip to Item B(3)) Private (go to item 2(a)) 2a If private, applicant will be: f.'_] Retaining Ownership (i.e, store, church, single office, etc„) or O Leasing units (lots, townhomes, etc, - skip to Item B(3)) TA Selling units (lots, townhomes, etc, - go to Item B(2b)) 2b. If sold, facilities owned by a (must choose one) El Public Utility (Instruction D) 0 Homeowner Assoc /Developer (Instruction E) 0 3, Charlotte Water — Owner of Wastewater Treatment Facility F) Treating Wastewater From This Project 4a: McAlpine Creek 4b. NC0024970 ..._ Name of VVWTF NMATTF Permit No , . ....., 5a, Charlotte Water .,, 5l:i. 8" ..wc — Gravity I5c. WQ10337 __ ! LL Owner of Downstream Sewer Receiving Sewer Size IC Force Main I permit # of Downstream Sewer (Instruc- tion F Z 6 th The origin of this wastewater is (check all that apply): 0 Residential Subdivision 0 Apartments/Condominiums 0 Mobile Horne Park 10 School Ei Restaurant El Office Ej Retail (Stores, shopping centers) El Institution O Hospital 0 Church EJ Nursing Home [1] Other (specify): 100P/0 Domestic/Commercial % Industrial (Attach Description) % Other (Attach Description) 7, Volume of wastewater to be allocated or permitted for this particular project 250 gallons per day *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: El Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. [7] Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T 0303 to determine if a permit is required) FTA 10-14 APPLICATION Page 4 of 6 i ^ Z 0 0 Design Flow (MGD) 2 0 Z B. PERMIT •9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (t). 25gal/employee x 10 employees 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 Length (feet) New Gravity or Additional Force Main 371 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID: (self chosen - as shown on planslmap for reference) Longitude: Latitude: 'Operational Point Power Reliability Option GPM @TDH 1 - permanent generator w(ATS; 2 - portable generator w/MTS Force Main Size 1 Force Main Length Pump Station Location ID: (self chosen - as shown on planslmap for reference) Longitude: Latitude: Design Flow (MGD) r Operational Pointl Power Reliability Option GPM @TDH 1 - permanent generator wIATS; 2 - portable generator wIMTS Force Main Size ! Force Main Length 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ❑ Yes ® No If Yes, permit number of 2" d treatment facility : (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request (VADC 10-14) application and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. FTA 10-14 APPLICATION Page 5 of 6 14, Have the following perrnits ca ions been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Trout Suffer Waiver? Stormwater? El Yes Li No E Yes ❑ No [p Yes [IJ No Yes El No N/A N/A NIA Li NIA 15. Does this project include any high priority lines 05A NCAC 02T ,0402 (2)) involve aerial lines, siphons, or interference manholes)? These Pines will be considered high priority and must be checked once every six months Check if Yes: El and provide details. Owner/Permittee's Certification: (Signature of Signing Official and Project Narne) 1, tti+f 'i(604 attest that this application for Rivergate Office, Phase 1 has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that. if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143-215,68 any person who knowingly makes any false statement„ representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10, 000 as well as civil penalties up to $25,000 per APP Z 0 Official Signa Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS CATION, THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC, REFER TO 15A NCAC 02T .0305 H 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) Q c 1, ,attest that this application for Rivergate Office, Phase 1 has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge., 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June '1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that l have reviewed this material and have judged it to be consistent with the proposed design. Note: !n accordance with NC General Statutes 143-215, 6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10„000 as well as civil penalties up to $25,000 per violation, e lA 2a. Kevin Caldwell Professional Engineer Name 2b, GeoScience Group, Inc, Engineering Firm 2c. 500K Clanton Road Mailing Address 2d Charlotte City 2g. 704-525-2003 2 h. 704-525-2059 Telephone Facsimile 2e NC 2f. 28217 State Zip 2i. Ikcaldwell geoscience9roul E-mail w _. NC PE Seal, Signature & Date FTA 10-14 APPLICr' TIt:1 ' Page 6 of 6 CHARLOTTE WLJER July 28, 2015 Mr. Kevin Caldwell Geoscience group 500K Clanton Rd. Charlotte, NC 28217 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE RIVERGATE OFFICE PH I— FRESENIUS MEDICAL CARE 14166 STEELE CREEK ROAD CLTWATER TRACKING# 600-15-614 A flow acceptance study of the subject site has been completed and the following has been determined: Charlotte Water (CLTWater) agrees to accept the additional gravity sewage flow of 250 gallons per day (10 employee medical office x 25 gpdiemployee) from this project for transmission to the McAlpine Creek Creek Wastewater Treatment Plant; NPDES permit number NC€1024970, for treatment. This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works, Please see attached FTSE form. CLTWater agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, PWS ID # 0160010, on file with the Public Water Supply Section of NCDENR. However, CLTWater cannot guarantee a constant pressure or quality of flow. Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater end sewer system is accepted on .a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction, if the poropriate authorization to construct permits are not obtain d and construction has not started within one (1) year of issuance of this flow acceptance study, and payment for any service connection(s) has not been received within (1) year of issuance of this flow acceptance Letter, this approval shall rescinded anda new flow acceptance study must be made, If you have any questions, you may contact me at (704) 432-5801. Sincerely, Barbara Gross Engineering Assistant Charlotte' Water ' t N, Tryon St, Charlotte, NC 28202 charlottewater.org operated by the City of Charlotte /A TI1 it jt r_ _ 1 A Division of Water Resources State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: Geoscj.ence Groun Project Name for which flow is being requested: Riverqate Office PH I - Fresenius Medical Care More than one FTSE may be reguired for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek WWTP b. WWTP Facility Permit #: NC002497D, NC0024945, NC0024937 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 99.0 10.253 69.208 0.00025 79,462 80.3t II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Station (Name or Number) Firm Capacity,* MGD Steele Creek 8.60 (A) Design Average Daily Flow** (Firm / pf), MGD Approx. Current Avg. Daily Flow, MGD 3.44 4.267 (B) (C) . (D)=(B+C) (E)={A-D) Obligated, Not Yet Total Current Tributary Flow Plus Daily Flow, Obligated Available MGD Flow Capacity*** 0.486 4.753 -1_111 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can he achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pi) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Page 1 of 6 FTSE 08-13 111. Certification Statement: i II certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections 1 and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this fortdicates acceptance of this wastewater flow. Signing Official Si are Da e Page 2 of 6 FTSE 08-1 $ U.S.USGS T OF E DE� S. GEOLOGI AL SURV YERIt3R changing world 81 °00' 35°07'30" The National Map USTopo 57' 30" E 2 ; 940000 FEET iNcti 4 5 [Sewer Location PROJECT NARRATIVE: RIVERGATE OFFICE PHASE I. The proposed commercial development is located on 11.73 acres of land surrounded by highway 49 (York Road), highway 160 (Steele Creek Road), and Old Steele Creek road, The proposed gravity sewer for this phase will connect to the Charlotte Water sewer system tying into their line on the west side of Old Steele Creek Road by open cut. The total length of the Sewer System being permitted is 371 LF RC VE NCDENR/DWR WQROS MOORESVILvL.E: REGIONAL OFFCCE GEQSC1ENCE GROUP To: Attn: LETTER OF TRANSMITTAL North Carolina Department of Environment And Natural Resources 610 E. Center Avenue Mooresville, NC 2811.7 Water Quality Section We are sending you: Attached VIA: Overnight The following items: Shop Drawings Specifications Under separate cover Consulting Engineers DATE: 7.28.15 CH 15.001.3.0 V TASK: PHASE: Rivergate Office Pp Regular Mail Pick-up Prints Copy of Letter Calculations Change Order V N r)FNR/fWR 3 WOROS MOORESVILLE REGIONAL orF CE Hand Delivered/Couriered Disks Other Copies 1 Da 7.28.1.5 No. Description Applica Check for $480 THESE ARE TRANSMITTED as checked below: !IIIIFor Approval 1 For your use Remarks: As Requested For Review and Continent Approved as Submitted Approved as Noted Returned for Corrections Copy To: Signed: Scott Gregory 500 Clanton Road Charlotte, North Carolina Telephone Facsimile Suite K 28217 704.525.2003 704.525.2051 Corporations Division Page 1 of 2 North Carolina eatrie F marshall DEPARTMENT T Secret iiy ECRE &R�I P Y OF LATE PO Box20V22 Weiti1, t O2742643671 t4191l r7.2PAO Click Here To: Account Login Register View Document Filings Fife an Annual Report Amend a Previous Annual Report Corporate Names Print a Pre -Populated Annual Report form Legal: Childress Klein Properties, Inc. Business Corporation Information Sosld: Status: Annual Report Status: Citizenship: Date Formed: Fiscal Month: State of Incorporation: Registered Agent: Corporate Addresses 0231609 Current -Active Current Domestic 7/15/1988 December NC Johnson, Cyrus M. Mailing: Principal Office: Reg Office: Reg Mailing: Officers 301 S College St, Suite 2800 Charlotte, NC 28202-6033 301 S. College St, Ste 2800 Charlotte, NC 28202-6033 301 S. College St., Ste 3500 Charlotte, NC 28202-6050 301 S. College St., Ste 3500 Charlotte, NC 28202-6050 Vice President: Vice President: Vice President: Vice President: Secretary: Vice President: Vice President: Gordon A Buchmiller , Jr 300 Galleria Pkwy Atlanta GA 30339 Christine M Chase 300 Galleria Parkway, STE 200 Atlanta GA 30301 Thomas C G Coyle , Jr 301 S College St Charlotte NC 28202-6042 Christopher J Daly 301 S College St Charlotte NC 28202-6042 Susanne G Davis 300 Galleria Pkwy Atlanta GA 30339 John R Decker 300 Galleria Pkwy Atlanta GA 30339 http://www.secretary.state.nc.us/Search/profcorp/4959042 7/31/2015 Corporations Division Page 2 of 2 Deborah B Duniec 301 S College Street, Suite 2800 Charlotte NC 28202 Secretary: Lee Ann Gibbs 301 S. College Street, Suite 2800 Charlotte NC 28202 Vice President: R David Haggart 301 S College St Charlotte NC 28202-6042 Assistant Secretary: Kate Hoos 301 S College St. Suite 2800 Charlotte NC 28202 President: Fred W Klein 301 5 College St Charlotte NC 28202-6042 Assistant Secretary: Shelley Lassiter 301 S. College Street, Suite 2800 Charlotte NC 28202 Assistant Secretary: Morgan Lowery 301 S. College Street, Suite 2800 Charlotte NC 28202 Secretary: Barb Repp 301 S. College St, Ste 2800 Charlotte NC 28202 Assistant Secretary: Carolyn Sarrio 300 Galleria Parkway, STE 200 Atlanta GA 30301 Vice President: Landon R Wyatt , III 301 S College St Charlotte NC 28202-6042 Stock Class: COMMON Shares: 100000 Par Value: 1 http://www.secretary.state.nc.us/Search/profcorpl4959042 7/31/2015 Central Files: APS ^ SWP 8/12/2015 Permit Number WQ0037940 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.iove Coastal SWRu1e Permitted Flow 250 Facility Version A Permit Classification Individual Permit Contact Affiliation Facility Name Rivergate Office Phase 1 Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Childress Klein Properties - Dates/Events Owner Type Non -Government Owner Affiliation Steve Hoots Construction Dr of 2800 One Wells Fargo Ctr Charlotte NC 28202 Orig Issue 8/13/2015 Scheduled App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 7/30/2015 8/13/2015 8/13/2015 Regulated Activities Requested /Received Events Office Wastewater collection Outfall Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasin 'ater Resources vironmennil. ity February 16, 2017 Mr. Steve Hoots, Director of Construction Childress Klein Properties 2800 One Welk Fargo Center Charlotte, NC 28202 SUBJECT: Final Engineering Certification Acknowledgement Project: Rivergate Office Phase 1 Permit No. WQ0037940 Perrnittee: Childress Klein Properties County: Mecklenburg Dear Mr. Hoots: ROY COOPER G overnor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN DireCtor The Division of Water Resource's Mooresville Regional Office received the final engineering certification with record drawings for the subject sewer extension project on February 16, 2017'. Enclosed is a certification page for your records. A full review of the certification materials may or may not be conducted, It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. However, if a full technical review is conducted, you will be notified of any items of non-compliance. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you. have not received such copy from your consultant, please contact .them immediately to obtain a copy. Lastly, you are receiving this letter because the Division has you listed as the .responsible party. If this permitted system is no longer owned by you or your company, please complete Form PNOCF since the permit is not automatically transferable. Form PNOCF can be downloaded from http://portal.nedenr.orelweb/willswp/psics/pnoe from the Collection Systems Applications page. Should you have any questions, please do not hesitate to contact me at (704) 235-2143. Sincerely., Barry Love Environmental Specialist cc: Mr, Kevin S. Caldwell, RE., (Geoscience Group, 500-K Clanton Road, Charlotte, NC 28217) Central Files Compares— Sntte of North Carolina 1 Lim, nonrrienuil Qualgy 1 Water Resources Water Quality Regional Operations MoornYille Reiglonal Office 610 EaS1 Cente' M',-,'nue, Suite 301 MonTesville„ North. Co rol LI 5 5 704.663-1 i';')9 FAST TRACK SE ER ENGINEERING CERTIFICATION PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: Childress Klein Propertir WQ0037940 Rivergate Office Phase 1 February 3, 20117 WDROS This project shall not be considered con plete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted, PERK TTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted ein orortj„ons thereof, Steve Hoots, Dirn t Printed Name, Title Signature ENGINEER'S CERTIFICATION Date I, Kev n S. Caldwell, P.E. as a dui registered Professional En ineer in the State of North Carolina, having been authorized to observe (J periodically,[l weekly, [J full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: inal [] Partial (include description) Certification Comments/Qualifiers (attach if necessary): Mooresville Regional Office NC DWR water Quality Regional Operations Section 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Phone: (704) 663-1699 FAX; (704)•-633-6040 To:. Attn: We are sending you: The following items: Copies Da Consu LETTER OF TRANSMITTAL Attached Overnight Shop Drawings Specifications No. 7 2.3.17 Under separate cover Regular Mail Pickup Prints 11 Calculations Copy of Letter Change Order Description nd. Delivered/C©u:riered Disks Other Fast `f"rack Engineering Certification As -Built — Sheet C THESE ARE TRANSMF For Approval For you use ED as checked below: As Requested For Review and Comment Approved as Submitted Approved as Noted Returned for Correcti Copy To:. 500 Clanton Road Suite IC Charlotte, North Carolina 28217 ed: Kevin Caldwell. Telephone Facsimile 7(14.52.5.2003 704,525,2051 0 EX I5'HCP 24,1,527,7 V.3'.-62 E. XtSTJNV.=t'i1 7.34 i=k YF„.HfV'Y PD'EV.IN.622.31 WJY.OUT-622.2 o o 0Q,0o....._ t ;.0U.0o R:1,Drawings120i5 Proj s\Ries rgat'e ONic:e SUSS_C:ONS:RUCTIGN"vRIVFRSU82.71.17.dwg, 2/15/2'017 76:29:78 AM, 1:40 tlNV.IN-622.94 IN'V,OUT-622,70 4 620 610 RIVERGATE OFFICE SEWER AS -BUILT SCALE:1 "=40' GE SCIENCE GROUP loomerood 500 K Clanton Road Charlotte, NC 28217 Phone:7©9,525:2003 fax: 704.525,2051 www.geoscime:egroup.eom