Loading...
HomeMy WebLinkAboutWQ0037764_Regional Office Historical File Pre 2018 (2)North Carolina Department of Environment and Natural Resources Pat McCrory Governor May 13^DJIS Mr. Roy E.Carroll, U'Manager Horizons atSteele Creek, LLC 2Q1N.Elm Street, Suite IO1, Greensboro, N[]74Q1 Subject: PenmitNo.VVQ0037764 Horizons atSteele Creek Wastewater Collection System Extension Permit Mecklenburg County Dear Mr. Carroll: Donald R. van der Vaart Secretary In accordance with your application received April 30, 2015' we are forwarding herewith Permit No,VVQ0037764 dated May 13, 2015, to Horizons at Steele Creek, LLC(Pernnittee) for the construction and operation upon certificatiOp of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered o part of this permit and is therefore incorporated therein by reference. Please pay particular attention tothe following conditions contained within this permit: [onditimnU.I: This permit shall not be automatically transferable; a request must be made and approved. CondNUonU.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued tothe Perrnittee. it ShGU be the responsibility of the permktee to ensure that the as -constructed project meets the appropriate design criteria and rules, Failure tocomply, may result inpenalties ioaccordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, nrlimitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt efthis permit. This request must be in the form of written petition, conforming to Chapter lSOB of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, N[Z769B-6714. Unless such demands are made, this permit shall befinal and binding. Mooresville Regional Office Go]East Center Avenue, Suite 301^Mooresville, m[28z15 Powne�r04-6Va'z8g9\Fax 704' 63-6840\[ustome,Sa^/|ce1-877-6I5-e748 mtemet:wmnw.ncvmtevz9a|lty-o,m An Equal Opportunity\ Affirmative Action Employer - Made in part by recycled paper Horizons at Steele Creek, LLC Permit No.uXQ0037704 If you need additional information concerning this matter, please contact Barry Love at (704) 235-2143 b# S.Jay Zimmerman, Qloec1o, Division of Water Resources, NCDENR byMichael Parker, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division ofWater Resources, NCDENR cc: B. Bruce Nooe P.E. (electronic copy) Barbara Gross (electronic copy) Tommy Rowland (electronic copy) Regional Office Files Water Resources Central Files Page 2 of 8 A RbENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION. DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Horizons at Steele Creek LLC Mecklenburg County for the construction and operation of approximately 1,949 linear feet of 8-inch gravity sewer to serve 288 apartment units, a clubhouse, and .a pool as part of the Horizons at Steele Creek project, and the discharge of 43,036 GPD•of collected domestic wastewater into the Charlotte Water existing sewerage system, pursuant to the application received April 30, 2015, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the cified conditions anii`ations contained therein. 6 for 5. Jay Zimmerman, Director Division of Water Resources, NCDENR By Authority of The Environmental Management Commission Permit Number: WQ0037764 Permit Issued: May 13, 2015 Page 3 of 8 SUPPLEMENT EMENT TO PERMIT COVER SHEET Horizons at Steele Creek, LLC is hereby authorized to: Construct, and then operate wuVm certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Charlotte Water McAlpine Creek Wastewater Treatment Facility in accordance with Permit Number NCO024970, Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC ]T; the Division's Gravity Sewer Minimum Design Criteria adopted March 4, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast'T/ackPermitdnA nfPump Stations and Force Mains adopted June l, 3OOQaxapplicable, unless specifically mentioned herein. Division approval is based on acceptance, ofthe certification provided by North Carolina -licensed Professional Engineer in the application. It shall be the Permittce'u responsibility to ensure that the a5'cunstructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions 'identified below, 1. SPECIAL CONDITIONS 1. This permit shall become voidable unless the agreement between Horizons at Steele Creek, LLC and Charlotte Water for the collection and final treatment of wastewater is in fm|| force and effect. [15A Z. No flow in excess of the quantity permitted herein, 43/036 GPD shall be made tributary to the subject sewer system wmtU an application for permit modification for an increase in flow has been submitted toand approved bVthe Division. [15AN[A[02T.0]04(b)l 11. STANDARD CONDITIONS l. This permit isnot transferable. |nthe event there isadesire for the wastewater collection facilities to change ownership, or there is name change of the Pennittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials asmay beappropriate. The approval ofthis request shall beconsidered onits merits and may urmay not heapproved. [1SANCACO2T.0lU4;6.S143'215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein, .15ANCACO2T.01101 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110) 4, The wastewater collection facilities shall be properly maintained and operated atall times, The Page 4 of 8 I operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: t15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice. shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143- 215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T,0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. Page 6 of 8 c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page7of8 FAST TRACK SEWER ENGINEERING CERTIFICATION, ~ PE0N0ITTEE: Horizons atSteele Creek, LL[ PERN4IT#/ VvQ0037764 PROJECT: Horizons atSteele Creek ISSUE DATE: May 13,2O15 This project shall not be considered complete nor allowed tooperate in accordance with Condition 7of this permit until the Division has received this Certification and all required supporting documentation, It should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Pm'mh1ee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification sh8U be a complete set ofrecord drawings and design calculations regardless ofvvhetherpartiabhave been nubrnitted. PERMITTEE'S CERTIFICATION |, the undersigned agent for the Pcmnittep, hereby state that this project has been constructed pursuant to the applicable standards, & requirements, the Professional Engineer below has provided applicable design/construction information tothe Pcrmittee,and the Pennitteeisprepared tooperate &maintain the wastewater collection system permitted herein orportions thereof, Printed Name, Title Signature ENGINEER'S CERTIFICATION as a duly registered Professional, En i eerin the State ofNorth Carolina, having been authorized to observe ([—Y periodically, -- weekly,� [—1 full time) the construction of the project narne and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A WCACO2T| the Division of Water Resources' (Division) Gravity Sewer K;|mirnmnm Design Criteria adopted March 4, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/5ignature & date: Final F] Partial (include description) Certification Comments/Qualifiers (attach if necessary): NC DWR — Water Quality Regional Operations Section 610 East Center Avenue, Suite 301, Mooresville, NC 28115 ^x...,..x°n~�.../n^n-~ ok.­ '7"^`C_C_z ,^uu cxv-'`n^` =z�3 =o"^ 10510 ,took, atl~ . INEERING AND SURVEYING, INC. LAIV reveLOPMeNT CONSULT** CORPORATE LICENSE NUMBER C-I315 4400 T7?IN15 S MI* HUSH FC►IKI`, NORTH C ROUNA 71265 $12-eeoo - FAX. 086) 812-818o STREET LEVEL MAP GOOGLE EARN IMAGE NoRIZONS AT STEELE CREEK z 0 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD Owner/Perrnittee: Horizons at Steele Creek, LLC Application Number: (to be completed by DWR) Full Legal Name (company, municipality, HOA, utility, etc.) lb, Roy E. Carroll, II , Manager Signing Official Name and Title (Please review 15A NCAC 2T ,0106 (b) for authorized signing officials) The legal entity who will own this system is: 0 Individual 0 Federal 0 Municipality 0 State/County 0 Private Partnership Corporation" k ` Q 1 d, 201 North Elm Street Suite 201 LL. Mailing Address If. NC z 0 2 State lh. 336-275-6198 Telephone 1e. Greensboro City lg. 27401 Zip Code WQROS MOORESVILLE REGIONAL 1j. dburton@cipconst.com Facsimile E-mail 2. Proiect (Facility.) Information: 2a.. Horizons at Steele Creek Brief Project Name (permit will refer to this name) Contact Person: 3a. Bruce Nooe, PE CPT Engineering & Surveying, Inc. 2b. Mecklenburg County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 336-812-8800 ext. 315 3c. brucen@cptengineering.com Phone Number E-mail Project is New 0 Modification of an existing permit) If Modification, Permit No.: iF 2. Owner is 0 Public (skip to Item B(3)) ® Private (go to Item 2(a)) 2a. If private, applicant will be: 0 Retaining Ownership (i.e. store, church, single office, etc.) or Leasing units (lots, townhomes, etc. - skip to item 8(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(26)) Charlotte Mecklenburg Utilities Division 2b. If sold, facilities owned by a (must choose one) 0 Public Utility (Instruction D) 0 Homeowner Assoc./Developer (Instruction E) Owner of Wastewater Treatment Facility (WWTF) Treating Wastev 4a, McAlpine Creek Wastewater Treatment Plant Name of WWTF Sa, City of Charlotte _ ►� Gravity Owner of Downstream Sewer 'Receiving Sewer Size 0 Force Ma The origin of this wastewater is (check all that apply): 0 Residential Subdivision Apartments/Condominiums [� Mobile Home Park 0 School © Restaurant El Office ater From This Project 4b. NC0024970 WWTF Perm 5c, Unknown n Permit # of Downstream Sewer (Ins 0 Retail (Stores, shopping centers) 0 Institution 0 Hospital 0 Church 0 Nursing Home 0 Other (specify): Clubhouse Volume of wastewater to be allocated or permitted for this particular project: 43,036 *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: ction F 100 % Domestic/Commercial % Industrial (Attach Description) Other (Attach De gallons per day ion) 0 Pump Station„ Outfall or interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T ,0303 to determine if a permit is required) FTA 10-14 APPLICATION Page 5 of 6 Provide the wastewater flow calculations used in determining the permitted In accordance with 15A NCAC 2T..0114 for`, the value in iteirra B(7) AND/OI1 the design flow for One or pump station sizi t if a reduced ©r zeros flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f), 288 units x 135 gpd/unit = 38,880gpd Clubhouse = 6,112 sf x 50 gpd/100 sf = 2,556 gpd Pool: 160 person pool x 1D gpd/person = 1,600 gpd Total = 43,E gpd 10. Summary of Sewer Lines to be Permitted (attach a Size (inches) 8 al sheets Length (feet) 1,949 New Grmr ty or Additional Force Main New Gravity z P 11. Surnrnary of Pump Stationswf associated Force Mains to be Permitted (etiach arddi onal sheets as necessary) Z d Pump Station Location ID: (self chosen - as shown on plans/map for reference) La etude: Latitude: Z 0 Design Flow (MGD) Operational Po GPM @TDH Power Reliability Option - permanent generator w/ATS; Force Main Slze Force Main 2 - portable generator wIMTS Pump Station Location ID: (self chosen - as shown on plans/map for reference) Longitude: Latitude: Design Flow (MGD) Operational Point GPM t TDH Power Reliability Option - permanent generator w/ATS; Force Main Size Force Mein Length 2 - portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? 'El Yes 'r`r No If Yes, permit rrrarawber of 2""r treatnrrent facility (RO — If "yes' to 13,12', pease contact the Central Office PERCS Unit) 13. Does sewer system comply with the n Crl(erie for P (latest version), the G ini ritar (latest version Yes 0 No Pumt rte. F nd 1 A ICAC p T If No, complete and submit the V anciaiAlternative.Deakin Raauetst (VDDc 19- pfali ticrt r documents for review. Approval of the request is required prior to submittal of the Fast Track A supporting documents. FTA l0.14 APPLICATION 6 6 14. Have the following permits/certitications been submitted for approval far the system or project to be served? Wetland/Stream Crossings - General Permit or 401Certification? 0 Yes 0 No ►i< N/A Sedimentation and Erosion Control Plan? 0 Yes 0 No 0 N/A Trout Buffer Waiver? 0 Yes ❑ No >«< N/A Stormwater? 1 Yes 0 No ❑ N/A 15. Does this project include any high priority lines (15A NCAC 02T .0402 (21) involve aerial lines, siphons, or interference manholes)? These tines will be considered high priority @rid m st be checked once every six months Check if Yes: fl and provide details: 1a. Owner/Pemiittee's Certification: (Signature of Signing Official and Project Name) /, Roy E. Carroll, II, Manager, Horizons at Steele Creek, LLC attest that this application for Horizons at Steele Creek Apartments has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if ail required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signing Official nature ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETER PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY to TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T .0305 Z 0 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) I, Bruce Nooe, P.E. ,attest that this application for Horizons at Steele Creek Apartments has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: in accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. B. Bruce Nooe P.E. Professional Engineer Name 2b. CPT Engineering and Surveying, Inc. Engineering Firrn 2c. 4400 Tyning Street Mailing Address 2d. High Point 2e, NC 2f, 27265 City State Zip 2g. 336-812-8800 2h. 336-812-8780 2i, brucenacptengineering.corn Telephone Facsimile E-mail NC PE Seat, Sign & Date PTA in_19 ©PPI TrATACIT! Pn„A 7 .r� April 28, 2015 Mr. Chuck Truby CPT Engineering & Surveyin 4400 Tyning St. High Point, NC 27265 n CHARLOTTE W TER SUBJECT: WATER AND SEWER FLOW ACCEPTANCE HORIZONS AT STEELE CREEK TAX PARCEL ID# 199-181-09, 199-541-01 CHARLOTTE WATER TRACKING# 600-14-600 A flow acceptance study of the subject site has been completed and the following has been determined: Charlotte Water agrees to accept the gravity sewage flow of 43,036 gallons per day (288 apartment units x 135 gpd/unit; 70 person pool x logpd/person;. 5,112 ft2 clubhouse x 50 gpd/100 ft2) from this project for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works. Please see attached FTSE form. Charlotte Water agrees to fumish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act. Amendments of 1986, and The Water Supply Management Plan, PWS ID # 0160010, on file with the Public Water Supply Section of NCDENR. However, Charlotte Water cannot guarantee a constant pressure or quality of flow. Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved, Connection to the Charlotte Water and sewer system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. if the appropriate authorization to construct permits are not obtained, and construction has not started within one (1) year of issuance of this flow acceptance letter, and payment for any service connection(s) has not been received within (1) year of the issuance of this flow acceptance letter, this flow acceptance approval shall be rescinded and a new flow acceptance study must be made. If you have any questions, you may contact me at (704) 432-5801. Sincerely, Barbara Gross Engineering Assistant Charlotte Water 700 N. Tryon St, Charlotte, NC 28202 charlotte Operated by the City of Charlotte State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flo Tracking/Acceptance fo Project A.l: phcant Name: c iect Name for which flow is uc'ticn -equfred fur d sr ased it^acte water equested: or ans Name: t are the owner o Applications (FTSE 08-1.3) Tater treatment plant. Creek, Szw±r Creek, Sugar Creek WWTP NC0024970, NC'002494S, NC0024937 All floare in MGD c. WWTP facility's permitted flow 99. o d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g.. Total actual and obligated flows to the f°acility 79,1. 4 h. Percent of permitted flow used 2 69.208 0,04.3 60.01 Complete this section for each pump station proposed wastewater flow. onsible for along the route of this List pump stations located between the project connection point and the WWTP: (A) (B) (C) fl )=(B+C) Design Obligated, Pump Average Daily Approx. Not Vet Total Current Station Firm flow** Current Avg.. Tributary Flow Plus (Name or Capacity,* (Firm l pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** 8.6 0.423 4.690 -1„a 49. * The Firm Capacity of any pump station is defined as the maximum pumped flow tha can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump sta factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. Page 1 of 6 n divided by a peaking cause any en route to the re olz the planned analysis has beet the best available nts in accordance rtil cation app plus all attached planning assessment addendua'ns prov$ es se arer overflows tar ta��erhtardcn any do�tastte� t plaarit uunder normal circtttnstatt ces, i °t n the ctatitied ita flee f laannino assessment �ahere with liae tl establislaecl ra ali fcs Signature of has Canna indicates aceeptaartee oftlais wastewater flow. g 6 y knov ledge that the addition of altsated altang the route to the s not anticipated to np station ble. and procedures using in Sections I and 11 ponsible Submit a planning Capacit ° is C 0. FTSE ]PLANNING" ASSESSMENT ADDENDUM (PAA) asses enl addendum for each pump station listed in Section 11 where Available Purnp Station (Name or Number): Given that: a. 'The proportion and amount of (a °'u and 'Tributary Daily f low tC:) accounts for Available Capacity (P) in Fuinp Station provide the required planned capacity, namely. ek Pump Station Replacement and Relief Sewer is in design or under construction ww ith planned completion in Summer 2017 ; and/or d. The following applies: The Steele Creek Pump Station replacement pruj ct wall pr©vide a new regional facd tic able of Summer ©17. 9 ~construction to be completed in .. . _ handling build -out flews in the basin, with Sa.r.le and th f acti atic ri ofthis obligated, not yet tributary capacity is currently approximately MOD per year; and that unded Capital Pi Therefore: Given reasonably expected conditions and planning information„ there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over allocating capacity in the system infrastructure, I understand that this does not relieve the co'tlect.ion system owner from complying with G.S. 143-215.67(a,) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Signing ignatu Page 3 of 6 Date NARRATIVE FOR Horizons at Steele Creek Apartments MECKLENBURG COUNTY CHARLOTTE, NORTH CAROL NA April 28, 2015 OWNER/DEVELOPER: Carroll Investment Properties. Inc. 201 North Elm Street Greensboro, North Carolina 27401 (336) 275-6198 CPT Engineering and Surveying. Inc. 4400 Tyning Street High Point, NC 27265 Phone (336) 812-8800 • Fax (336) 812-8780 WQRUS MOORESVILLE REM AL CG "F °E PROJECT DESCRIPTION The project is located on an approximately 18.88 acre tract in Mecklenburg County, Charlotte, NC. The purpose of the project is to construct twelve (12) apartment buildings with 283 total units, a clubhouse and pool with associated paved drives and parking including extension of existing water and sewer service. SITE DESCRIPTION The site consists of 18.88 acres more or less and currently has two single family homes that will be demolished. ADJACENT PROPERTY Land use in the vicinity is a mix residental and vacant land. The site fronts along Steele Creek Road (NC Highway 160). SOILS INFORMATION The soil in the project area is mapped as Iredell fine sandy loam per USDA Natural Resources Conservation Service Web Soil Survey. All soils are in hydrologic group "C/D". The site slopes west to east at approximately 5% average slope. uscis QUAD MAP CHARLOTTE VEST QUADRANGLE HORIZONS AT STEELE CREEK CITY OF CHARLOTTE NE<GKLE& COUNTY, NORTH GAROLINA PATE: 4/213/15 Engineering & Surveying, Inc. April 28, 2015 North Carolina Department of Environment and Natural Resources Water Quality Section 610 E. Center Avenue Mooresville, N,C, 28115 Re: Fast -Track Application (FTA 10-14) For Horizons at Steele Creek (Apartments) Mecklenburg County, Charlotte, NC RECEIVEDINCOENRIDWR WQHUS MOORESVILLE REGIONAL OFFICE On behalf Horizons at Steele Creek, LLC, we are submitting herewith for your review and approval the following documents relative to the above referenced project: - (I) Original Fast -Tract Application - (1) Copy of Fast -Tract Application - (1) Check for $480 (Horizons at Steele Creek, EEC) Specifications for this project will be per the City of Charlotte standards and specifications. We respectfully request your review and approval of these items. If you have any questions or need any additional information, please give me a call. Thank you for your assistance with this matter. Sincerely, CPT Engineering and Surveying, Inc Bruce Nooe, Enclosures 4400 Tyning Street • High Point, NC 27265 Phone: (336) 812-8800 • Fax: (336) 812-8780 www.cptengineering,corn Central Files: APS ...�. SWP 5/13/2015 Permit Number WQ0037764 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.love Coastal SWRu!e Permitted Flow 43,036 Facility Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Horizons at Steele Creek Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Horizons at Steele Creek LLC Dates/Events Owner Type Non -Government Owner Affiliation Roy E. Carroll 11 201 N Elm St Greensboro NC 27401 Orig Issue 5/13/2016 Scheduled App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 4/30/2015 5/13/2015 5/13/2015 Regulated Activities Requested /Received Events Apartment complex Additional information requested Condominium Additional information received Wastewater collection Ouffall Waterbody Name Streamindex Number Current Class Subbasin PAT MCt:.:RCtRY covemov DONALD R. VAN DER VAART Seer etc -cry S. JAY ZIMMERMAN Water Resources ENVIRONMENTAL 4VALITV J Roy E. Carroll, II, Manager Horizons at Steele Creek, LLC 201 N, Elm Street, Suite 201 Greensboro, NC 27401 y 2016 SUBJECT: Final Engineering Certification Acknowledgement Project Horizons at Steele Creek Permit No, WQ0037764 Permittee: Horizons at Steele Creek, LLC County: Mecklenburg Dear Mr. Cara The Division of Water Resource's Mooresville Regional Office received the final engineering certification with record drawings for the subject sewer extension project on June 28, 2016. Enclosed is a certification page for your records. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the pei nit, However, if a full technical review is conducted, you will be notified of any items of non-compliance. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received such copy from your consultant, please contact them immediately to obtain a copy. Lastly, you are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you or your company, please complete Form PNOCF since the permit is not automatically transferable. Form PNOCF can be downloaded from http://portal.ncdenr.org/web/wq/svvp/ps/cs/onoc from the Collection Systems Applications page. Should you have any questions, please do not hesitate to contact me at (704) 235-21,43. Sincerely, Barry Love Environmental Specialist. cc: Mr. Jim Jackson, (CPT Engineering and Surveying, Inc., 4400 Tyning Street, High Point, NC 27265) Central Files MRO State of North Carolina I Environmental Quality I Water Resources 610 E. CenterAvenue. Suite 301, Mooresville, NC 28115 Phone: 7O4-663-16991 Internet: wrwrim,ncdene.gov iFASTTFiAtiattiER MdiNEOINGtERTIFitATI614 iigkm-olkf! Atgoffixg4.04:Ji PRRIAITia.:lat)37764: P#0):VOI Nitikko 0,1001g'0'0•0)( ISSUpAlp: 44.16‘flpIA MAP C OUdO IVN010313 3111AS3800111 SOECOM 9tQZ Nor UMOUNBOONICI3A13 338 Tbr 1417.16110.6.67.011-1taqjg Conditron of fhii*iratturifikifie4A4g10 hasli400 ,146411.41:41104 t1.4.tig4' WOPPrtflig ,t10.0#1.01-4:ti_Oft 5.0.1f.ffittOd. a';it.Atler tifa:).74:011fakitOL the 019Vta ceip Send the tegiirred docurnentalym Ito the flegjim4$1.ipeptsog Water 44Atitylijo' golgi Gpratons4kdIgi..at. th-.44.40(0.sAt at the fltitttfil.. AOY'wg4wigrflow.tnagig tributary t ihg-WoggtAtotoo1J041*v.ottoo ottottioii 06tioi to tfiffij5.1.eti.eiii 0441.4 tiftifteitliiii-thali be :etiiiid&cra violation of of ifie7peiriiii and.:shafl subject The appropriate gqfPrgginiqd.gctioi itipTRAtnlIttgP,AtOpfsgklAIOritto.601:1110 rottiortgailitoti,O4* tiiitiliJitialthittfrotrcitrktepitiied,,M9iaI coittf:1604frth'ili1a*ifkoi* *pfrqc9t0 OivAngs ard 001,grcgolgplifkinrs tggpyciloo::-Af'*teittOr. otrirat-40,44414,00.4t' krien-i*ii14.etRifirfcAticrt,, 1 the Otntiritkfde.t!:ilqO'4*Rt4tVVtMifj?.F--e ' ' ' .'. I "' 6-I5r tf fiaibeeii. t iiiiitiiiitedTursua rite . toArleia0.01041# standards eq:119:c10:e000V.,t,t4:1PriiIgglitl:ADgiriRtr00w-111-PI:411i'de4. al-)att4.0e; #0.iitAtillAtlf.dtki.ji-1667.0.4VPARA,"-..iffkiiitt**'irt0.1#61.0*-(4A VT*51-VitI4-iislikeit0 .-gt,f'lltal!ilarlw tli.i4gfewaterigf,..6.4fabiOrarii pefOittialliefelii'bilVatiiiii1111.64ofi, .-__.., , .s. ....,.., , '..t&wieif..iltitribist: ,..• _....., r•.,:.1 .' • , P;-7.•,-,7....,-,.--...- PrirtleSilktfkititlIA ))j1--.' gr1.9gi• ki;''' Fri aiiii ifillaiikTil J44 ir.3,2,‘..... • ' EY ei 7A4r - .:',!' ' as fi,"-iic;',1'414.:&ilii6.04.(itijklik4tAir:Viii1.74tff 00ottli-so.040, k ba:_ylifiSib..!.70,,,:tiktit.,,,,,,Aled,,, :i.t•i)-e-.0.1isifv'e: - uipTgiii.r.diZi.t 2-- 011"'f'Vt A _T-_.q till' ,tfit)--driti-e'tb*ttuittaiteifiii§ I .4. pri!..gte;,,ytir1a& dT.,,74_9pcie.,:#4:na-rA:',.(e74.:re„,,q:Ile:ia",*,iiiifff7.-rl. ,F,Atiy:pi zOtftzapPi,dRgeliCelk:itil,ettt rIi.;411M1rrrii1i;;'4'iCrSrCti':. "iii9; 'ii:: c°10(4001:11*gible_154etalleTaiiiiiiiiitiglilfiKAP1414`4!4"''—'11-ffi' °I1 c " t e tilyrA90,4 vitat6rwgii.tifEeirtttifigivai- , ,-..vil-5919Firaf-...atfrelttiii$P .414-57,kT!''':1.ii ,„... , ,=:. , n ravitykScwqn inen-0 -IDesti' :. 1 7-- ' '' 't. -'' d' g 4R13001§10 plggtv'rgor?0-64itiiiiiiikameerit6ti.- Arihlikllett-Tr. _ii,.4c0, Wr4101315....04,,,:to 4;., TO.R.9; Fqt•Feliiiiti_ __.,_6.i..._ ri,,,,,._,i, --,,, •• ,,„. , -,,,,,,,..;,,,,,,-141,-:„.,,,c,--ox.,f,,,,:-*Attlittifirgro.p,t4trotikatyp y4 1 ,., p992KeRN ..... ,= ,g.q.ppligtipt y erttiiipodfog*atKi ' ' — ' • -- " - • ' .- 4 rt .., . .h-r,----- - Eliiitibtaro1inaliixtfessionittnefieeei$6iO4sit tiettiteAtrite:-, . . „ r "i•sii.f.' - c.`"01$./.5'• f - • *lc : A • ?atotif if, • .1:1-potlikiolott.o4osiii4:(Fif, a ca-ttotgreoto*-6tRyckbafiem-fetzhif-04** :4 4414M :44 4 koiVott I ifittrOdtkribsiii4Obri Fit211$ A ,„: Mefolts.itlik'APIANdia.t.Qf*k • 7.7•71,...., = Engineering & Surveying, Inc, To: NCDENR-DIVISION OF WATER RESOURCES Attn: BARRY LOVE. 610 E. CENTER AVE, SUITE 301 MOORESVILLE, NC 28115 LETTER OF TRANSMITTAL Date: 6/17/16 Job No: 1306-14 Attention: BARRY LOVE Re: HORIZONS AT STEELE CREEK APARTMENTS-SAN. SEWER AS-BUILTS We are sending you: ® Attached ❑ Under separate cover via : the fo1101+ittgLitemsEN R,SANR ❑ Plans ❑ Diskette(s) ❑ For Approval ® For Review ❑ Specifications J U N 2 0 2 016 ❑ Other: WQROS MOORESVILLE F3L:.0.0NAL OFFICE Quantity Dwg. No. Description Status 1 SET PRIVATE SANITARY SEWER AS-BUILTS SHEET 4 UTILITY SHEET SHEET 1 OF 3 PLAN/PROFILE SHEET (LINE 1 AS -BUILT) SHEET 2 OF 3 PLAN/PROFILE SHEET (LINE 2 AS -BUILT) SHEET 3 OF 3 PLAN/PROFILE SHEET (LINE 3 AS -BUILT) Status Code: A. Approved B. Sign and Return C. Amend and Resubmit Remarks: BARRY, D. Rejected - See Remarks E. For your information F. Refer to Remarks G Approved - As noted H. As Requested I. Review and Comment PLEASE ACCEPT THE ATTACHED SANITARY SEWER AS -BUILT FOR YOUR REVIEW. LET ME KNOW IF YOU REQUIRE ANYTHING FUR1'ILI R. THANK YOU FOR YOU TIME. cc: I Jackson CP'`Engineering and Surveying, Inc. 4400 Tyning Street • High Point, NC 27265 Phone: (336) 812-8800 • Fax: (336) 812-8780 www.cptengineering.com