Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0037359_Regional Office Historical File Pre 2018
North Carolina Depa NCDENR ent of Environment and Natural Resources Pat McCrory John E. Skvarla, III Governor Secretary September 25, 2014 Mr. John L. Christine, Deputy Aviation Director City of Charlotte 5601 Wilkinson Boulevard Charlotte, NC 28208 Subject: Permit No. WQ0037359 Remote Rental Car Facility Wastewater Collection System Extension Mecklenburg County, NC Dear Mr. Christine: In accordance with your complete application received September 22, 2014, we are forwarding herewith Permit No. WQ0037359, dated September 25, 2014, to City of Charlotte for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter and supplement shall be considered a part of this permit and are therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in. accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permitllee. It shall be responsibility of the City of Charlotte to ensure that th.e as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with. North Carolina. General Statute § 143-215.6A through § 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional :Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 67 14 Mail Service Center, Raleigh, NC 27699-671.4. Unless such demands are made, this permit shall be final and binding. 2317 bail Service Center, Raleigh, North Carolina 27699-2317 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807.6492 Internet: wrxw.nc'waterResources.orrg An Equall Opportunity l Affirmative Acton Employer Mr. John L. Christine September 25, 2014 Page Two If you need additional information concerning this matter, please contact Michael Parker at (704) 235- 2194 or via e-mail at Michael.Parker@ncdenr.gov. Sincerely, for Thomas A. Reeder Division of Water Resources by Michael L. Parker, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Electronic copy: Steven D. Swygert, P.E. cc: Mooresville Regional Office, Surface Water Protection Section Water Resources Central Files PERCS (e- copy) Barbara Gross (e-copy) Willis Horton (e-copy) f' AwA NCDENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Charlotte for the construction and operation of approximately 980 linear feet of 4-inch gravity sewer, 903 linear feet of 6-inch gravity sewer, 1892 linear feet of 8-inch gravity sewer to serve the Remote Rental Car Facility, and the discharge of 6,800 gallons per day of collected domestic wastewater into the Irwin Creek WWTP existing sewerage system, pursuant to the complete application received September 22, 2014, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and Iimitations contained therein. Permit issued this the 25th day of September, 2014. for Thomas A. Reeder Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ00373 59 SUPPLEMENT TO PERMIT COVER SHEET City of Charlotte is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Irwin Creek Wastewater Treatment Facility prior to being discharged into the receiving stream. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division of Water Resources (Division) Gravity Sewer Minimum Design Criteria adopted Febntary 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and. Force Mains adopted :tune .1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina. -licensed Professional Engineer in the application. It shall, be the Permittee's .responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS If, at any time, the additional wastewater flow volume made tributary to this sewer extension is believed to exceed the value permitted herein, a modification shall be requested for this permit from the Division of Water Resources to properly allocate the subject wastewater flow. 2. No flow in excess of the quantity permitted herein, 6,800 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division of Water Resources. iI. STANDARD CONDITIONS This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 2. This peltilit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Resources (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting .materials unless specifically mentioned herein. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and. maintenance of these facilities as required by 15A NCAC 2T .0403, if an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: r a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute § 143-215.1 C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the Iegal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi-annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. Noncompliance Notification: The Permittee shall report by telephone to a Water Resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300, Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken. or proposed to be taken to ensure that the problem does not recur. Part II of Form CS- SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State, 7. Per 15A NCAC 2T.0123, upon completion of construction and prior to operation of these permitted facilities, the competed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification.. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following': a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting pump station design calculations (selected pumps, system curve, operating point, buoyancy calculations, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non- compliance with this permit (including pipe length increases of 10%© or greater, increased flow, pump station. design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to constriction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 9. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. 10. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 11. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A.NCAC 2H .0500. FAST TRACK ENGINEERING CERTIFICATION Permittee: City of Charlotte Permit No. WQ0037359 Project: Remote Rental Car Facility — Mecklenburg County Issue Cate: 09/25/2014 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension, Final record drawings should be clear on the plans or on digital media (CD or DVD disk) in pdf format. Record drawings should indicate the design and the marked up changes during construction. Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modificat ons are requird for any changes miniimumrdesign criteria, Modifications should belsubmitted prior ting in o certification.liance this permit, regulations or This project shall not be considered complete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. PERMITTEE'S CERTIFICATION , the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof, Printed Name, Title Signature ENGINEERS CERTIFICATION Date Partial ❑ Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS SURFACE WATER PROTECTION SUPERVISOR MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. DM) rise Only: Flow from this l)rt). e Michael Baker INTERNATIONAL September 8, 2014. Innovation Done Right...l e Make a Da Water Quality Section North Carolina Department of Environment and Natural Resourses 610 East. Center Ave. Mooresville, NC 28115 SUBJECT: Mecklenburg County Charlotte Douglas International Airport Remote Rental Car Facilities 2014 Project To Whom It May Concern: -err The Charlotte Douglas international Airport proposes a construction project for a new rental car maintenance facility (RCMF) to include four rental car buildings, four fuel islands, approximately 10 acres of lot pavement, widening and reconstruction of Barry Drive to accommodate tractor trailer and fuel truck access, storm drainage system, stortnwater detention, water, sewer, power, telephone and communication lines coordination. This project will include the construction of a new gravity sewage flow. of 6,800 gallons per day (40 employee offices x 25 gpd/employee/2 shifts; 4 car wash bays x 1,200 gpdibay) from this project for transmission to the Irwin. Creek Wastewater Treatment Plant. Please let me know if you have any further questions, Encls. Sincerely Michael Baker International Steven D. Swygert,P.E. Operations Manager - Hydrology Jrna OsAr1YPORT MBAKERINTL.C©M 10© Air5ide ©rive A Moon Township, RA 15108 Office : 412,269.63001 Fax 4123753980 z 0 0 z z USE THE TAB KEY TO MOVE FROM FIELD TO FIELD Owner/Permittee: la. City of Charlotte Full Legal Name (company, municipality, HOA, utility, etc.) 1b. John L. Christine Deputy Aviation Director ApplicationNumber: (to be completed by DWR) Signing Official Name and Title (Please review 15A NCAC 2T ,0106 (b) horized signing officials lc, The legal entity who will own this system is: ❑ Individual ❑ Federal Municipality ❑ State/County ❑ Private Partnership ❑ Corporation ❑ Other (specify): ld. 5601 Wilkerson Boulevard Mailing Address 1f, NC State 1 h, 704-359-4022 1 i. 704-359-495 Telephone Facsimile . Project (Facility) Information: 2a. Remote Rental Car Facility Brief Project Name (permit will refer to this name) 3, Contact. Person: 3a. Steve Swygert Michael Baker International Oast n 1e. Charlotte City lg. 28208 Zip Code 1 j. jIchristine cite irpor„corn E-mail 2b, Mecklenburg County Where Projec is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 803-254-2211 Phone Number Project is New ❑ Modification (of an existing permit 3c. ssWyert €+ rt-ibakerintI.c E-mail Modification, Permit No.: 2. Owner is D Public (skip to item B( Private g© to item 2(a)) 2a, If private, applicant will be: Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc. - skip to Item 8(3)) 0 Selling units (lots, townhomes, etc. go to item 8(2b)) 3, Charlotte -Mecklenburg Utilities Department 2b. If sold, facilities owned by a (must choose one) © Public Utility (Instruction D) ❑ Homeowner Assoc.CDeveloper (Instruction E) Owner of Wastewater Treatment Facility (WWTF} Treating Waste ater From This Project 4a. Irwin Creek Wastewater Treatment Plant 4b. NC 0024945 Name of WWTF 5a, C-MUD 5b. 8" Owner of Downstream Sewer Receiving Sewer Size 6. The origin of this wastewater is (check all that apply): ❑ Residential Subdivision 0 Apartments/Condominiums ❑ Mobile Home Park 0 School Restaurant ►h1 Office WWTF Permit No, Gravity i5c. 5092 Force Main Permit # of Down ❑ Retail (Stores, shopping centers} ❑ Institution D Hospital ❑ Church ❑ Nursing Home Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project: 68Q0 *Do not include future flows or previously permitted allocations 8. if the permitted flow is zero, indicate why: eam Se (Instruction F) 100% Domestic/Commercial Industrial (Attach Description) % Other (Attach Description) gallons per day O Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T,0303 to determine if a permit is required} F1"A 08- i 3 APR 7ATit::}N Page 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item 6(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). See Attachment 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main 8 1892 6 903 4 980 M 1 Z 11. Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) ' 2 0 Pump Station Location ID: N/A (self chosen - as shown on plans/map for reference) Longitude; Latitude: 2 0 ...... Design Flow Operational Point Power Reliability Option . - (MGD) GPM t, TEM 1permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS Pump Station Location ID: (self chosen - as shown on plans/map for reference) Longitude: Latitude: Design Flow Power Reliability Option Operational Point (MGD) GPM TOP! 1 - permanent generator WATS; Force Main Size Force Main Length 2 - portable generator w/MTS 12, Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? [11 Yes No If Yes, permit number of 2nd treatment facility : (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Perrnittemot Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? Yes D No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FIA 08-13 APPLICATION Page 5 of 6 Z 0 14. Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit aar 401 Certification? © Yes 0 No N/A Sedimentation and Erosion Control Plan? ® Yes 0 No Ej N/A Trout Buffer Waiver? 0 Yes D No N/A Stormwater? ► Yes Q No 0 N/A 15. Does this project include any high priority lines 5A NCAC 02T 04 J2m_( ) involve aerial lines, siphons, or interference manholes)? These lines will be considered hicth priority and must be checked once every six months Check if Yes: 0 and provide details: l a. Owner/Percniftee's Certification: (Signature of Signing Official and Project Name) 1, John L. Christine , attest that this application for Remote Rental Car Facility has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that i'f all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General States 143-215,6A and 143-275.15E, any person who knowingly makes any false statement, representation, or e ficKir"on in any appli tin shall be guilty of a Class 2 misdemeanor, which may include a fine not to exc. ed $10,000 a$2 . :er Mkt?,, Official Signature 9 Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T .0305 2, Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, Steven D. Swyrtert ,attest that this application for Remote Rental Car Facility has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes '14,3-215.6A and 143.215,6f, any person who knowingly makes any false statement,representation, or certification in any application shalt be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Steven D. Swygerl Processional Engineer Name 2b. Michael Baker Engineering Firm 2c, 700 Huger Street Mailing Address 2d. Columbia City 2e. SC 2f. 29201 State Zip 2g. 803-254-2211 2h. 803-779-8749 2i. sswygertmbakerintl.com Telephone Facsimile E-mail NC PE Seal, Signature r Date FTA fi8-t3 APPLICATION Page 6 of 6 T"1'E-MECKLENBURG TY DEPARTMENT August 15, 2014 Mr. Clayton McCathern Michael Baker Corporation 700 Huger ST Columbia, SC 29201 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE CDIA REMOTE CAR RENTAL FACILITY TAX PARCEL# 055-367-01 C-MUD TRACKING# 600-14-608 A flow acceptance study of the subject site has been completed and the following has been determined.' Charlotte -Mecklenburg Utility Department agrees to accept the gravity sewage flow of 6,800 gallons per day (40 employee offices x 25 gpolemployeei2 shifts; 4 car wash bays x 1,200 gpd/bay) from this project for transmission to the Irwin Creek Wastewater Treatment Plant; NPDES permit number NC0024945, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatment works. Please see attached FTSE form. Charlotte -Mecklenburg Utility Department agrees to furnish water to the subject project, The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, PINS ID # 0160010, on file with the Public Water Supply Section of NCDENR. However, C-MUD cannot guarantee a constant pressure or quality of flow. Charlotte -Mecklenburg Utility Department does not expect any of the above conditions to preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the Charlotte -Mecklenburg tidbit De artment s stem is acce ted era a First come first served basis. The applicant should understand that this letter is not authorization to construct private water and sewer systems, as the appropriate local or State permits are required prior to construction. if the appropriate authorization to construct permits are not obtained and construction has not started within one (1) year of issuance of this flow acceptance letter,: and payment for any service connection(s) has not been received within (1) year of issuance of this flow acceptance letter, this flow acceptance approval shall be rescinded and a new flow acceptance study musthemade. If you have any questions, you may contact me at (704) 432-5801. Sincerely, Barbara Gross Engineering Assistant CHARLOTTE-MECKLENBURG UTILITY DEPARTMENT Engineering Division • Installation 8. Development Services www,emutilities.com 700 North Tryon Street Charlotte, NC 28202 Ph: 704/432-5801 Fax. 704/432-5804 Mate ofttth Carolina Department of Enviroatntent and Natural Resources Division of W ter Resources Flow °I't aching/Acceptance fo c Applications GI..t„'lr 08-I3) icant Nanme:. Afore e than ryo•t 17vti"1 may be his sect a,. WWW```I`U Facility 'Name: b. AVW'f"l' Foe. Permit c.. WWII' facility d C�hlig h. p s, Pump. Station (Nance or Number) fac tiara 'ou are the owner ()file wastewater tretataraent plant, Its s acttaat a{f r this specific and obligated rtt)ittc'Cf flow u tributary to the "WV'FP the ta .AI! flows are in s=b GD ection for each pump station you are responsibly for along the route of this Capacity,' \IGt) The Firm Capacity o connection Dint and the WWII': (0)=(11+(::) Obligated, Approx, Not Vet lfocal Current Current Avg.. Tributary Flow Plus Daily flow, Daily Flow, Obligated Av°datable .MGD MOD,Flow Capacity*" pump station is defined as the maximum pumped tlow can be achieved with the largest pump taken out of service. .Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor fptl not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WW°C'P where the Available Capacity is < O. Page I of 6 ut receiving wastewater treatntoilt tactltty cause any capacity related sanitary sewer en route to the receivirt treatttent t°�lant. of the planned improvements identified tt tJ analysis has been performed in accordance wit reify to tle best of my knowledge that the aditien of ed in tiris project has been, evaluated along the route to the and that the now from this project is not anticipated to overflows or overburden any downstream pump station under normal circumstances, given the implementation planning assessment where applicable: This sst.ablishcd policies and procedures using the hest available data, This certification applies to those items listed above in Sections I and II plus all attached planning assessment addend.urns for hick l trtt the responsible party°. Signature of this form indicates acceptance of this wastewater flerrv=, F SE PLANNING A,SSESS;MEN" ADDFNFILIN (PAA) 'planning assessment addendum for ea e@ pump .slat; lump Station Given that: a.. The prc portion and tinioimt Ohiigatctf, Not Y t ,� and Ava.i I a arui that h, The rate cf activation crfthis obligated, not yet tributary capacity is currently appro m f) per year; and that dt that will provide the required planned capacity, namely n design or under construction 'with A rim( planned completwl The following applies: ;.xr it ". PY rt :ra' ; t redat,, 1.;utEi, Therefore: (:Given reasonably e pc' tcd coltditiorrts and planning info nt .l to allow, this flow to he permitted, witllctt.lt significant Jielihood of over -allocating the system infrastructure, kWeation pacit: in f understand that this does not relieve the collection system owner fro ci, 'plying with (S, 43-215,67(ti) which prohibits the introduction of any waste itt eatcss of the t,apac.ity of the waste disposal syslcnl.. .,° existing Sewer Milting Manhole Proposed Sewer +�► Proposed Manhole SITE LOCATION MAP SANITARY SEWER FAST -TRACK APPLICATION CHARLOTTE DOUGLAS INTERNATIONAL AIRPORT CHARLOTTE, NORTH CAROLINA 0 600 , 00 I, it 0 Cale in Feet CLT RCSF Site Aerial • Central Files: APS — SWP _ 9/25/2014 Permit Number WQ0037359 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer michael.parker Coastal SWRu1e Permitted Flow 6,800 Facility Version 1.00 Permit Classification Individual Permit Contact Affiliation Facility Name Remote Rental Car Facility Location Address Owner Major/Minor Region Minor Mooresville Facility Contact Affiliation County Mecklenburg Owner Name Owner Type City Of Charlotte Government - Municipal Owner Affiliation John L. Christine Aviation Deputy Director 5601 Wilkinson Blvd Dates/Events Charlotte NC 28208 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 9/25/2014 9/22/2014 9/25/2014 9/25/2014 Regulated Activities Requested /Received Events Car wash facility Office Wastewater collection Outfall Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasin wyw NCDEN North Carolina Department of Environment and Natural Resources Division of Water Resources Pat McCrory Thomas A. Reeder John E. Skvarla, Ill Governor Director Secretary pa -.WA/ C. Chi'%Y), 664 / C ,7/4f t a / bo, //t & w than, C.€r 1 /' f c zB , 2014 Subject: Fast Track Application Return ,� Project Name: e?i, e / l Om1-5-c /r AIL County, North Carolina Dear lE./Ms. c i2/0 The Division of Water Resources, Mooresville Regional Office received your Fast Track sewer application on g ' /7- During an initial review of your application, your application was determined to be incomplete. Therefore, your application is being returned. (Please include a copy of this letter with your resubmittal). For a listing of the correct forms and instructions please visit: http://portal.ncdenr.org/web/wq/swp/ps/cs/ext Please complete/correct the following deficiencies: ❑ Application submitted on wrong or outdated forms. Form(s): ❑ Corporation is not listed with the State of North Carolina. ❑ Application was submitted without a processing fee or with an incorrect processing fee. Application did not contain a Flow Tracking Form (FTSE 08/13). Application did not contain the Developer's/Homeowner's Operational Agreement. Application did not contain the correct number of copies. ❑ Application failed to include project map. , 14- p p ll � r ,s Gt aii�O e camp /e NI , �-s ea i R rV-7 ❑ Application (line A.1 b) was not signed by an authorized representative in accordance with 15A NCAC 2T .0106(b). (see http://h2o,enr.state.nc.us/admin/rules/codes_statutes.htnn) [�l ioo Pt014-, 5.09/1 4 d Following submission of a complete application, the Mooresville Regional Office will begin a technical review of your application. If your application is technically deficient additional information may be required or the package may be returned again. Mooresville Regional Office Location: 610 Fast Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-16991 Fax: (704) 663.60401 Customer Service:1.877-623-6748 Internet hltp:llportaI.ncdenr.orglweblwq One NorthCaroli.na 7 turaiy An Equal Opporlunily \ Affirmative Action Employer--50% Recycled/10% Fos! Consumer paper