Loading...
HomeMy WebLinkAboutWQ0036570_Regional Office Historical File Pre 2018NCDENR North Carolina Department of Environment and Natural Resources Division of Water Resources Water Resources Programs Pat McCrory Thomas A. Reeder John E. Skvarla, III Governor Director Secretary August 2"d, 2013 Ms. Cheryl Lumsden, Treasurer DeVere Construction Company, Inc. 1030 DeVere Drive Alpena , MI 49707 Subject: Permit No, WQ0036570 Modification The Exchange at Charlotte Wastewater Collection System Extension Mecklenburg County, NC Dear Ms. Lumsden: In accordance with your complete application received July 31 , 2013, we are forwarding herewith Permit No. WQ0036570, dated August 2"d, 2013, to DeVere Construction Company, Inc. for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, shall void permit WQ0036570 issued June 17th, 2013, and shall be subject to the conditions and limitations as specified therein. This cover letter and supplement shall be considered a part of this permit and are therefore incorporated therein by reference. The modification of this permit is a transfer of ownership from Apex Construction Services, LLC to DeVere Construction Company, Inc. Please pay particular attention to the following conditions contained within this permit: Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be responsibility of Apex Construction Services to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General. Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. 1617 Mail Service Center, Raleigh, North Carolina 27699 1617 Location' 512 N. Salisbury St. Raleigh, North Carolina 27604 Rhone; 919-807-6300 FAX 919-807-6492 Internet: www.ncwaterquati ,o v� �a ryu Ilnr ,rirnhn, ti t rmn Nne orthhCarolina V aurally If you need additional information concerning this matter, please contact Michael Leggett at (919) 807- 6312 or via e-mail at MichaeLLeggett@ncderir.gov. Sincerely, for Thomas A. Reeder Division of Water Resources by Deborah Gore, PERCS Supervisor cc: Gene Ritz, Apex Construction Services, LLC (GeneRiitzfapexcsteen.com) Chei yl Lun'isci n, DeVe`e Corestiuctiuri Company, ii'lc. (LluHHlsuen@deverecc.us, Russ Greer, UNCC Millennium, LLC (rgreer@progressivecapital.org) Mooresville Regional Office, Surface Water Protection Section Water Resources Central Files PERCS (electronic copy) I .14 t NCDENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the DeVere Construction Company, Inc. for the construction and operation of approximately 2,000 linear feet of 8-inch gravity sewer to serve The Exchange at Charlotte development, and the discharge of 34,965 gallons per day of collected domestic wastewater into the Charlotte Mecklenburg Utilities existing sewerage system, pursuant to the complete application received June 10, 2013, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. Permit issued this the 2nd day of August, 2013. for Thomas A. Reeder Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ0036570 Modification r , SUPPLEMENT TO PERMIT COVER SHEET DeVere Construction Company is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in Mallard Creek Wastewater Treatment Facility prior to being discharged into the receiving stream. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. I. SPECIAL CONDITIONS 1. If, at any time, the additional wastewater flow volume made tributary to this sewer extension is believed to exceed the value permitted herein, a modification shall be requested for this permit from the Division of Water Resources to properly allocate the subject wastewater flow. 2. No flow in excess of the quantity permitted herein, 34,965 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division of Water Resources. I • II. STANDARD CONDITIONS 1. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. ° 2. For privately owned collection systems, the Grease Control Program shall include at least bi-annual distribution ofgrease education nnatchab to users nfthe collection system by the permitLee or its representative, l Grease education materials shall be distributed more often than required in Parts (l) and (Z) of this Subparagraph if necessary to preven|Qeasc,e|ated sanitary sewer overflows, i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment j. Documentation shall be kept for Subparagraphs (a) through (U of this Rule for a minimum of three yeas with exception ofthe map, which shall bemaintained for the life mfthe system, 5. Noncompliance Notification: The Permittee shall report by telephone to a water Nsrwms staff member at the Mooresville Regional Office, telephone number (704) 663-1699' as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc;or b. Any SSQand/or spill over 1'Q00gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered asthe initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (8O0) 858-0368 or (919) 733'3300. Persons reporting any of the above occurrences shall file aspill report bycompleting and submitting Part |oJForm CS-SIO(or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part UofForm CS-SS0(or the most current Division approved form) can also be completed to show that the SSO was beyond 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled mas not to interrupt oen4oe by the existing utilities nor ,coox in an overflow or bypass discharge ofwastewater vo the surface waters cfthe State. 7' Per 15A N[AC 2[0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents tothe address provided onthe form, Acomplete certification isone where the form is fuHy executed and the supporting documents are provided as applicable, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is Issued to a private entity with an Operational Agreement, then a copy mfthe Articles mf Incorporation, DedaeOous/Coxeuaot*/Retd#iwvs,and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. 4complete certification is one where the form isfully executed and the supporting documents are provided os I a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record(drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting pump station design calculations (selected pumps, system curve, operating point, buoyancy calculations, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non- compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. 8. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 9. Failure to abide by the conditions and limitations contained in this permit; 1SA NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. 10. In the event that the wastewater collection facilities fail to perform satisfactorily,. including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 11. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 1SA NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. FAST TRACK ENGINEERING CERTIFICATION Permittee: DeVere Construction Company, Inc. Permit No. WQ0036570 Project: The Exchange at Charlotte Issue Date: 08IO2/2013 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) in pdf format. Record drawings should indicate the design and the marked up changes during construction. • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. Modifications should be submitted prior to certification. This project shall not be considered complete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation. Therefore. it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. PERMITTEE'S CERTIFICATION 1, , the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date - ENGINEER'S CERTIFICATION ❑ Partial ❑ Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS SURFACE WATER PROTECTION SUPERVISOR MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. DWQ Use Only: Flow from this project is tributary to: FAST TRAC Nl T"t'1W1CATXON Perrnittee: D6Ver0 Constreotton Company, inc. Project: The Exchange at Charlotte Permit No. W00036I70 Issue Date: 013102l2013 Complete and submit VI form to the permit Iseuing regional office with the following: • One copy of the project record drawings (plan & profile views and detail drawings of sewer Ones) of the wastewater collection system extension. Final record drawings should be clear on the plans or an digital media (CD or DVD disk) In pdf format Record drawings should indicate the design and the marked up changes during construction, • Supporting design calculations (selected pumps, system curve, operating paint, available storage If portable generator(s) or ato greater than longest past three year outage reliability option selected) for any pump stations permitted es part of this project • Changes to the project should be clearly Identified on the record drawings or in written s€saatnary form. d as rea n U co t minimum dest m criteria. Modifications should be stibrrdtted odor to certification,, This project smell not be considered complete nor allowed to operate until the Division has received this Engineer's Cereflcat}on and all required supporting documentation. Therefore, it is hlahiv_,recommended that this cartifigatloq jae seat la amanner that provides proefpf !sootier; by the Division, P 'f :6'6 G>rltTlFmcArtoN that undersigned agent for the Perrntttee, hereby stale that this project has. applicable standards & requirements, the Professional Engineer below has Cation Information to the Permltteet and the Permittee is prepared to operate & ern pe herein or 'thereof. ENGINE CR lFicAT 51 Partial 0 Final as a duly registered Professional Engineer In the Stale of North Carolina, periodically, DI weekly, 0 full tine) the construction of the subject project the best of my abilities, due care and diligence was used In the observation IrucUan was observed to be butt within substantial compliance of title Sewer Minimum Design Criteria adopted February 12, 1t as for the Fast -Track Permitting of Pump Stations and Force supporting materials, er's SEND THIS FORM & SUPPORTING DOCUMENTATION. WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS SURFACE WATER PROTECTION SUPERVISOR MOORESViLLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 The Permltlee is responsible for IT ki i ail a t certifications up unit a final certification is received. Any wastewater flow made tributary to ttto wastewater collection system extension prior to campletlon of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permlttee to appropriate nforcement actions, iDWQ Use Only: Flow &am this project is tributary to: a. One copy of the protect construction record drawings (plan & profile views of sewer lines & fora: mains) of the wastewater collection system extension, Final record(drawings should be dear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated ° with after construction information and show required buffers, separation distances, material changes, etc, b. One copy of the supporting pump station design calculations (selected pumps, system curve, operating. point, buoyancy calculations, available storage If portable generator(s) or storage greater than longest past three year outage re►lability option selected) far any pump stations permitted as part of this project. c. Changes to the protect that do not result In non-compliance with this permit, regulations, or the Minimum Design Criteria should be dearly Identified an the record drawings, on the certlflcatlon In the space provided, or in written summary form, Prior to Certification (Final or Partial): Permit modifications are ret;ulred far any changes resulting In non- compliance with this permit (including pipe length Increases of 10%or great, Increased flow, pump station design capacity design Increases of 5% or greater, and Increases to the number/type of connections), regulations, or the Minimum Design Criteria, Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on Its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation, 8. A copy of the construction record drawings shall be maintained on file by the Permlttee far the life of the wastewater collection facilities 9. Failure to abide by the conditions and limitations contained In this permit; 15A NCAC 2T; the Di Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1; 2000 as applicable; and other supporting materials may subject the. Permlttee to an enforcement action by the Division, In accordance with North Carolina General Statutes §143-215.5A through e143.215,6C, construction of additional or replacement wastewater collectl©n fadilties, and/or referral of the North Carolina-Ilcensed Professional Engineer to the licensing board. 10. In the event that the wastewater collect an facilities fail to perform satisfactorily,. Including the creation of nuisance conditions, the PerrnIttee shalt take Immediate corrective action, Including those as may be required by this Division, such as the construction of additional or replacement fadilties. 11. The Issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rutes, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have Jurisdiction, including but not limited to applicable river buffer rules In i5A NCAC 26 .0200, erosion and sedimentation control requirements In 1SA NCAC Ch. 4 and under the Division's Generai Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and I5A NCAC 2H .0500. LETTER OF TRANSMITTAL To: NCDENR Dee Browder 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Re: The Exchange at Charlotte I am sending you the following 'item(s): DATE NO, These are transmitted as checked below: 0 Remark As requested For approval For review and comment Date: July 2, 2014 ** HAND DELIVER ** Job No.: PCG-13©©0 DESCRIPTION As -built sanitary sewer for System B and C Partial Certification Application Q For your use D Copy to: Signed: Robert M. Reddick, Jr., PE Senior Project Manager Raleigh -Durham 2905 Meridian Parkway Durham, North Carolina 27713 (919) 361-5000 Charlotte 11301 Carmel Commons Blvd., Suite 111 Charlotte, North Carolina (704) 527-0800 Designing Tomorrows infrastructure & Communities IV1cAdamsCo.com