Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0033735_Regional Office Historical File Pre 2018
AVA NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue, Governor Dee Freeman, Secretary January 20, 2009 Mr. Jay Lynch, President- Charlotte Division Morgan Corporation 3301 Stafford Drive Suite 1300 Charlotte, NC 28285 Subject: Permit No. WQ0033735 Morgan Corporation Site Improvements Tax Parcel #025-011-16 C-MU Tracking # 600-08-668 Wastewater Collection System Extension Mecklenburg County, North Carolina Dear Mr. Lynch: In accordance with your complete application received on January 9, 2009 we are forwarding herewith Permit No. WQ0033735, dated January 20, 2009, to Morgan Corporation Site Improvements for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3, which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. 610 East Center Avenue, Suite 301, Mooresville, North Carolina 28115 Phone: 704-663-1699 \ FAX: 704-663-6040 Internet: www.enr.state.nc.us An Equal Opportunity / Affirmative Action Employer - 50 % Recycled 110 % Post Consumer Paper NorthCairolina 7Vatllrattj Mr. Tony Lynch Page 2 January 20, 2009 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 335 linear feet of 8-inch gravity sewer and the discharge of 700 gallons per day of collected domestic wastewater into the Charlotte Mecklenburg Utilities existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the McAlpine Creek WWTP (NPDES No. NC0024970) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system is the complete responsibility of Charlotte Mecklenburg Utilities. Charlotte Mecklenburg Utilities must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WQCS00001 permit requirements. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Michael Parker at (704) 663-1699. Electronic copies: Cc: 2ncerely, („ 6 for Coleen H. Sullins Meredith Moore, Mecklenburg County Development of Water Quality Barbara Gross, CMU Philip Edwards, Mecklenburg County Julia A. Roberts, P.E., LandDesign, Inc. Mooresville Regional Office, Collection System Permit File Surface Water Protection Central Files PERCS V i NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 28 .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 3- r 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction drawings shall be maintained on fife by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or 2 b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 20th day of January, 2009. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0033735 3 1 Permit No. WQ0033735 January 20, 2009 OwnerIWQCS Tony Lynch P.O. Box 480130 Charlotte, NC 28269 PE Julian Roberts, P.E. LandDesign, Inc. 223 N. Graham Street Charlotte, NC 28202 WQCSIWWTP Barbara Gross CMU 5100 Brookshire Blvd Charlotte, NC 28216 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for anv changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and,all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ['weekly, ['full time) the construction of Morgan Corporation Site Improvements, a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. L TRANSMITTAL 223 North Graham Street, Charlotte, NC 28202 V:704,333,0325 F:704.332.3246 cics, n p1arioir s'w° I it Cyr I lardca:)e arc, ©ATE:: 11/17/2008 PROJECT NAME: Morgan Corporation Site Improvements TO: Dee Browder NCDENR 610 East Center Avenue, Suite 301 CC: WE ARE SENDING: Mooresville NC 28115 NUMBER OF PAGES: PROJECT #: BUS. PHONE: BUS. FAX: BUS. MOBILE: VIA: PURPOSE: 1008213 (704) 663-1699 (704) 663-6010 DRAWINGS SPECIFICATIONS x _' APPLICATIONS x_ FEES REDLINES DISK ICD OTHER IOUANTITY: ITEM: 'Fast Track Application Package 'Check Amount: $480.00 NOTES: YOUR USE x YOUR INFORMATION x REVIEW I COMMENT YOUR REQUEST SIGNATURE MAIL x APPROVAL FAX COURIER x . FEDEX GROUND FEDEX OVERNIGHT HAND DELIVERY PICK UP EMAIL DESCRIPTION: FROM: Robert. A. Keidel rak If this document was delivered via FAX, the accompanying transmission contains confidential information intended only for the use of the individual of the entity named above. I1 you are not the intended recipient, you are hereby notified that any disclosure, copying, distribution or the taking of any action in reliance on the contents of this facsimile information is strictly prohibited. If you have received this FAX in error, please immediately notify us by telephone to arrange for disposition or return of the documents to us. Charlotte NC Washington DC Tampa FL Asheville NC Pinehurst NC Charlotte NC Nashville TN Beijing PRC USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! 1, Owner/Permittee: la. Morgan Corporation_ 1e F- ull Legal Name (company, mun z 0 1- lc. The legal entity who will own this system is: El Individual [] Federal ❑ Municipality ❑ State ce O 1d. P.O. Box 480130 LL Mailing Address Z pality, HOA, utility, etc.) 2 0 0 J 2 0 • 5a. LL• 6. z 1b. Jay Lynch PrpSi.dt char.)r�ttp Di - Signing Official Name and Title (Please review 15A NCAC 2T ,0106 (b) for authorized signing o 1f. North Carolina State 1 h. 704-598-9117 1 i. 704-598-5973 Telephone Facsimile 2. Project (Facility) Information: 2a, Morgan Corporation Site Inprovements_ B- rief Project Name (permit will refer to this name 3. Contact Person: 3a, Julie Roberts Name and Affiliation of Someone Who Can Answer Questions Abou ']35 aunty ❑ Private Partnership Corporation ❑ Other (specify). 1e. Charlotte City 3b. 704-376-7777 Phone Number Project is O New ❑ Modification e 2. Owner is ❑ Public (skip to Item 8(3)) n existing permit) g. 28269 Zip Code.. jlynch aewmorgan-corj com 2b. Mecktenbura__. .._..�. County Where Project is Located this Application tc. jroberts@landdesign.com E-mail edification, Permit No.; 2a, If private, applicant will be: Retaining Ownership (i.e. store, church, single office, etc.) or Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. Charlotte -Mecklenburg Utilities 4a. astewater Treatment Facility _McAlpine Creek Wastewater Tr Name of WWTF Application Number: (to be completed by DWQ) V l 'q 1 otl Item 2(a)) 2b. If sold, facilities owned by a (must choose cane) ❑ Public Utility (Instruction C) ❑ Homeowner Assoc./Developer (instruction D) TF) Treating Wastewater From This Project en t Plant 4b. NC0024970 WWTF Permit No. Char-Meck Utilities 5b. 8" I Gravity 5c. CMUD Job # 100-97- Owner of Downstream Sewer Receiving Sewer Size ❑ Force Main Permit # of Downstream Sewer (Instruction E) The origin of this wastewater is (check all that apply): [] Residential Subdivision ❑ Apartments/Condominiums Q Mobile Home Park School Restaurant Office ❑ Retail (Stores, shopping centers) ❑ Institution 0 Hospital [] Church Nursing Home ❑ Other (specify):,._. 7. Volume of wastewater to be allocated or permitted for this particular project *Do not include future flows or previously permitted allocations 8, If the permitted flow is zero, indicate why. O Pump Station, Outfall or Interceptor Line where flow will be permitted in subserl ❑ Flow has already been allocated in Permit No, [} Rehabilitation or replacement of existing sewer with no new flow expected (see permit is required) 100 % Domestic/Commercial % Industrial (attach description,) (RO. contact your Regoonal Office Pretreatment staff) % Other (specify): 700 gallons per day 5A NCAC 02T .0303 to determine if a 2/07 ❑ G. Stream Classifications — Watershed Classification Attachment (Form WSCAS-12/07) If any portion of the sewer system project is within 100 feet of any surface water or wetlands, the Watershed Classification Attachment may need to be completed. A variance must be requested for encroachment within required setbacks or buffers pursuant to 2T .0305 (f) and be indicated in Item B-13 with supporting documentation/justification provided. ❑ H Environmental Assessments — If this project is subject to an Environmental Assessment (EA) [15A NCAC 01C], this application cannot be used. Send the project application on the most current version of Form PSFMGSA to the Design Management Unit, 1633 Mail Service Center, Raleigh, NC 27699-1633. Applications cannot be accepted until a Finding of No Significant impact (FONSI) or Environmental Impact Statement (EIS) has been issued. A copy is to be submitted with that permit application. ❑ I. Flow Direction — Many wastewater treatment systems are entering into agreements for regionalization efforts and emergency treatment capacity. Parts of the system are installed so that the wastewater flow can be directed to more than one treatment facility. if this is the case with this project, please indicate in B(12) and give the permit number of the second treatment facility. ® J. Certifications — Section C The application must be certified by both the applicant and the design engineer who is a North Carolina Registered Professional Engineer (PE). The applicant signature must match the signing official listed in Item A(1b). The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC Chapter 2T, the Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. THE COMPLETED FTA 12/07 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND $480 FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Fayetteville 'Regional Office 225 Green Street Suite 714 Fayetteville, North Carolina 28301-5094 (910) 433-3300 (910) 486-0707 Fax Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Mooresville Regional Office 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 791-4200 (919) 788-7159 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Washington Regional Office 943 Washington Square Mall • Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender Winston-Salem Regional Office 585 Waughtown Street Winston-Salem, North Carolina 27107 (336) 771-5000 (336) 771-4630 Fax Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin For more information, please visit our web site at: http:/lwww.nccgl.net/Engineering/Sewer%20Permits.html or contact the Regional Office serving your county. FTA 12/07 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 fort the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use; data in accordance with 15A NCAC 2T .0114. (f). [120 (GPD/1000SF) X 5816 SF Office] • 700 GPD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 Inch Length (feet) 335 New Gravity or Additional Force Main New Gravity s11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) W n Pump Station Location ID (self chosen - as shown on plans/map for reference) Z F., Design Flow Operational Point Power Reliability Option Z (MGD) GPM @TDH 1 - permanent generatorw/ATS; Force Main Size 0 2 portable generator w/MTS U' Z 0 Fr. 'Pump Station Location ID Design Flow C (MGD) LL Z Force Main Length!. Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; ; Force Main Size Force Main Length 2 - portable generatorwlMTS (self chosen - as shown on plans/map for reference) 1 Pump Station Location ID (self chosen - as shown on plans/map for reference) I Design Flow Power Reliability Option (MGD) Operational Point 1 - permanent generator w/ATS; I Force Main Size `f Force Main Length 1 GPM @TDH 2 - portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ❑ Yes ® No If Yes, permit number of 2nd treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 12/07 14. Have the following permits/certifications been submitted for approval for the system or project to be served? WetlandfStrearn Crossings - General Permit or 401Certification? 0 Yes [ No N/A Sedimentation and Erosion Control Plan? (l Yes ❑ No © N/A Stormwater? Yes ❑ No LI N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These Tines wilt be considered high priority and must be checked once every, six months Check if Yes: El and provide details Own er/Permittee" Certification. (Signature of Signing Official and Project Name) Jay Lynch , attest that this application for Morgan Corporation Site Improvements has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if ail required supporting documentation and attachments are not included, this plication package is subject to bein returned as incomplete. Note: In accordance with North Carolina General s 143-215.6A and 143-215.6B, an person who knowingly makes any false statement, representation, or ation in any placation shall be gut y of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 civil pen es up t $25, 000 pe violation. ENGINE.. RING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY u) TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC, REFER TO 15A NCAC 02T ,0305 Z 0 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, Julie Roberts attest that this application for Morgan Corporation Site Improvements has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans„ calculations, and all other supporting documentation to the best of my knowledge, i further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Matins adopted June 1, 2000 and the watershed classification in accordance with Divisiion guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Julie A, Roberts Professional Engineer Name 2h. LandDesign, Inc, Engineering Firm 2c. 223 North Graham Street Malting Address 2d. Charlotte City NC Zip 2g.704-333-0325 2h, 704-717-515© 2i. 'robeanddFsi Telephone Facsimile E-mail State 28202 NC PE Se l -t8 Signature & Date /07 DERITA, N.C. DMA 4854 IV SE -SERIES V842 1993 CHARLOTTE., CHARLOTTE-MECKLENBURG UTILITIES October 22, 2008 Ms. Julie Roberts LandDesign, Inc. 223 N Graham Street Charlotte, NC 28202 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE MORGAN CORPORATION — SITE IMPROVEMENTS TAX PARCEL# 025-011-16 C-MU TRACKING #600-08-668 In response to your request, a flow acceptance study of the subject site has been completed and the following has been determined: Charlotte -Mecklenburg Utilities agrees to accept the gravity sewage flow of 700 gallons per day (5,816 ft2 office x 120 gpd/1,000 ft2) from this project for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works. Please see attached basin map and flow tracking form. Charlotte -Mecklenburg Utilities agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, dated October 2005, (WSMP # 05-01702 & PWS ID # 0160010), on file with the Public Water Supply Section of NCDENR. However, Charlotte -Mecklenburg Utilities cannot guarantee a constant pressure or quality of flow. Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the Charlotte -Mecklenburg Utilities system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. if the appropriate authorization to construct permits are not obtained and construction has not started within one (1) year of issuance of this flow acceptance, this flow acceptance approval shall be rescinded and anew flow acceptance request must be made. If you have any questions, you may contact me at (704) 391-5129. Barbara Gross Engineering Assistant New Services Section CHARLOTTE-MECKLENBURG UTILITIES Customer Service Division • New Services Section www,cmutilities.com 5100 Brookshire Boulevard Charlotte, NC 28216 Ph: 704/399-2221 Fax: 704/393-2219 Charlotte -Mecklenburg Utilites P Service Areas with Basins State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE—10/07) Project Applicant Name: LandDes t qn, Inc . Project Name for which flow is being requested: Morgan Corporat. pan Site Improvements Mare than one FTSE-10/07 may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater,flowe I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek 41WTP b. WWTP Facility Permit #: NC0024970, NC0024945, NC0024937 All flows are in MGD c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 99.0 14.81 66.8 0.0007 81.67 82.5% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD Approx. Current Avg. Long Creek Paw Creek (Fi.►tii/Design) Daily Flow, MGD 7.80 3.20 7.7© 4.70 volume of waste Statement: r1 , certify that, to the best of my knowledge, the addition of the to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been perfotnied in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in. Sections I and rI for which I am the responsible party. Signature of this form indicates acceptance of thi +; tevvater flow, Signing 0cial Signature Date TRANSMITTAL 223 North Graham Street, Charlotte. NC 2 V, 704,333,0325 F: 704,332"3246 DATE. 11/17/2008 PROJECT NAME;, Morgan Corporal ton Site Improvements TO: Dee Browder NCDENR 610 East Center Avenue, Suite 301 Mooresville CC: WE ARE SENDING: VIA; NC 28115 IRA411NGS MAIL. SPECIFICATIONS FAX x APPLICATIONS COURIER x FEES x FEDEX GROUND REDLINES FEDEX OVERNIGHT DISK / CD HAND DELIVERY OTHER PICK UP EMAIL QUANTITY: ITEM; 1 Fast Track Application Package Check Amount;. $480.00 NOTES; FROM; i trtaert A. Keidel if this document was detoe'red via FAX, the 0,..., w..- __ If you are not the intended ravpsent, you are hereby notified that any dyer information is stnctfy prohibited, If you have received trot; FAX in error, p cr ng iarCIX.aDC DESCRIPTION: NUMBER OF PAGES: PROJECT #; BUS. PHONE:. BUS, FAX; BUS. MOBILE: PURPOSE; 1008213 (704) 663-1699 (704) 663-6010 x APPROVAL YOUR USE x YOUR INFORMATION x REVIEW / COMMENT YOUR REQUEST SIGNATURE rak ar irte a of Iradev t1 at rise eral%iy turned above dR action tni reliant` oent mta 5S its rasa mile ty r aty cas t wy 1e e td er rzra lot disposition or return of the documents to us. Charlotte NC Washington DC Tampa FL Asheville NC Pinehurst NC Charlotte NC Nashville TN Beijing PRC dvpira applic be inco'mplete. Tht.r your resubmittal). For a listing; of the correct forums and instructions please vkit: htt J'li E .em -t ire ti 'Iscr T ti r ! tp /Colle trot s c.rn pp9ic atl, ta1_;,ilbPl. Michael F. Easley, l_r 'et -nor William G. Ross Jr., .Secrc.tarl North Carolina t' epaot'rt argil 'Natural Resourz:e3 C tecr td. Stains', Dtrecto> O0S F tst Track, a .p6 la County, No Fol technical revs` be requir esti ill� Re giotsal C t tee re ..i:'ed. your Fat Track :sewer w of your applic.=a'ti n your application was determined to is being returned. ('Please include a copy of this letter with tI l te,c,one t tl'kr t ?Ilo ving delclt`n n submitted on wrong_ or outdated ti tt was srrin°itditlJcrat. a proc.esin rt dad not corttairr 1"lo °'Tracking I° tt did not contain the. Dev-eloper's'lt. rt did not contain the correct number .>,P fir sailed to include pr jcot rzra... nor-nE r - b) \vas not signed by an a 1A,)' tplcte appli icatiott. t your applica.ti may be retttrrred apai Roher Super Fast Track Sewer Fxtensi n : tit lication cco R0 File ti;'A helldocArast Track Return =08 610 East. Center .Ave. Suite 300 Moores' 0Ge, NC Permit Number WQ0033735 Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer michael.parker Permitted Flow 700 Facility Facility Name Morgan Corporation Site Improvements Location Address Owner Central Files: APS, SWP_ 01/23/09 Permit Tracking Slip Status Active Project Type New Project Version Permit Classification 1.00 Individual Permit Contact Affiliation Major/Minor Minor Region Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Morgan Corporation Dates/Events Orig Issue App Received Draft Initiated 01/20/09 01/09/09 Regulated Activities Office Wastewater collection Outfai{ NULL Scheduled Issuance Owner Type Non -Government Owner Affiliation Jay Lynch PO Box 480130 Charlotte Public Notice Issue 01/20/09 01/20/09 NC 28269 Requested/Received Events Additional information received Additional information requested Effective Expiration Waterbody Name Stream Index Number Current Class Subbasin • t North Carolina Secretary of State Page 1 of 1 North Carolina Elaine F. Marshall DEPARTMENT OF THE Secretary SECRETARY OF STATE PO Box 29822 Raleigh, NC 27626-0622 (919)807-2009 CORPORATIONS Corporations Home Search By Corporate Name Search For New Corporation Search By Registered Agent Important Notice Resale of Tickets Online Corporations FAQ Homeowners' Association FAQ Tobacco Manufacturers Unincorporated Non -Profits Dissolution Reports Non -Profit Reports Verify Certification Online Annual Reports LINKS & LEGISLATION KBBE B2B Annual Reports SOSID Number Correction 2001 Bill Summaries 1999 Senate Bills Annual Reports 1997 Corporations 1997 Register for E-Procurement Dept, of Revenue ONLINE ORDERS Start An Order New Payment Procedures CONTACT US Corporations Division TOOLS Secretary of State Home Secretary of State Site Map Printable Page Date: 1/12/2009 Click here to: View Document Filings I Sign Up for E-Notifications 'Print apre-populated Annual Report Form I Annual Report Count I File an Annual Report I Corporation Names Name Name Type NC Morgan Corporation of Legal South Carolina Business Corporation Information SOSID: Status: Date Formed: Citizenship: State of Inc.: Duration: Registered Agent Agent Name: 0101530 Current -Active 11/14/1980 Foreign SC Perpetual CT Corporation System Registered Office Address: 150 Fayetteville St., Box 1011 Raleigh NC 27601 Registered Mailing 150 Fayetteville St,, Box 1011 Address: Raleigh NC 27601 Principal Office Address: 1800 East Main St Duncan SC 29334 Principal Mailing Address: No Address Stock Class 99 SEE CERT Shares No Par Value 0 Par Value 0 http://www.secretary.state.nc.us/corporations/Corp.aspx?PitemId=4866957 1/12/2009