HomeMy WebLinkAboutGW1-2021-03862_Well Construction - GW1_20210823 WELL CONSTRUCTION RECORD For Internal Use ONLY:
This form can be used for single or mutiple wells
1.Well Contractor Information:
FROM TO DESCRIPTION
Chauncey Leggett ft. ft
Well Contractor Name ft ft
2269-A 4 .Q.,TEE O S G(for multi-cased e 1 O R if applicable
NC Well Contractor Certification Number FROM TO DIAMETER THICKNES MATERIAL
Lake Valley Well Co.,Inc 0 ft 134 ft 6.25 in. .188 Steel-galvanized
Company Name ft ft in.
JFROM
s2.Well Construction Permit#: E21-000041 TO DIAMETER THICKNES MATERIAL
List all applicable well construction pertmits(ie County,State, Variance,etc. ft ft. in.
3.Well Use: ft ft in.
TO DIAMETER THICKNES SLOTS MATERIAL
Residential ft ft in.
ft ft in.
RO
FROM TO MATERIAL EMPLACEMENT METHOD&AMOUNT
ft. ft Grouting Through
ft ft
ft ft
SA / L AC if.a plicable
FROM_ TO MATERIAL EMPLACEMENT METHOD&AMOUNT
ft ft
ft ft
4. Date Well(s)Completed: 3/26/2021 Well ID#
ft ft
5a. Well Location: 20. G G(attach additi na sheets if necess rynow
List all applicable well construction pertmits(ie County,State,Variance,etc. FROM TO DESCRIPTION(color,hardness,soiVrock type,grain size,etc)
Mike Elliott 037701 0 ft 35 ft Orange Clay
Facility/Owner Name Facility ID(if applicable) 35 ft 130 ft Orange Clayey Sandstone
Red Oak RD Whitakers 27891 Lot 130 ft 240 ft Gray Rock
Physical Address,City,and Zip 240 ft 382 ft Red Rock
Nash 383500639905 ft ft
County Parcel Identification No.(PK ft ft q
5b. Latitude and Longitude degrees/minutes/seconds or decimal degrees:
ft ft � ie
(If well field,one lat/long is sufficient.) 21. -
36.090825 N -77.858866 W Water zone at 230ft (i'C` "'s ^`�•���'Oil
6. Is(are)the well(s): Permanent
22. Certification: 00
7. Is this a repair to an existing well: No C�Yr 3/26/2021
If this is a repair,fill out known well construction information and explain the nature of the Signature of Certified Well Contractor Date
repair under#21 remarks section or on the back of this form. By signing this form,I hereby certify that the well(s)was(were)constructed in accordance
with I5A NCAC 02C.0100 or 15A NCAC 02C.0200 Well Construction Standards and that a
8. Number of wells constructed: 1 copy of this record has been provided to the well owner.
For multiple injection or non-water wells ONLY with the same construction,you can 23. Site diagram or additional;well details:
submit one form. You may use the back of this page to provide additional well site details or well
construction details. You may also attach additional pages if necessary.
9.Total well depth below land surface: 382 (ft)
For multiple wells list all depths if different(example-3@ 200'and 2 @ 100) SUMITTAL INSTRUCTIONS
10.Static water level below top of casing: 22 (ft.) 24a.For All Wells: Submit this form within 30 days of completion of well
construction to the following:
If water level is above casing,use"+" Division of Water Quality,Information Procession Unit,
11. Borehole diameter: 6 (in.) 1617 Mail Service Center,Raleigh,NC 27699-1617
12. Well construction method: Rotary air 24b.For Iniection Wells: In addtion to sending the form to the address in 24a
(i.e.auger,rotary,cable,direct push,etc.) above,also submit a copy of this form within 30 days of completion of well
construction to the following:
FOR WATER SUPPLY WELLS ONLY: Division of Water Quality;Undergroun Injection Control Program,
1636 Mail Service;Center,Raleigh,NC 27699-1636
13a. Yield(gpm): 10 Method of test: Air 24c.For Water Supply Iniection Wells: In addtion to sending the form to
the address(es)above,also submit one copy of this form within 30 days of
13b. Disinfection type: HTH Amount:
14 OZ completion of well construction to the county health department of the county
where constructed.
Form GW-I North Carolina Department of Environment and Natural Resources - Division of Water Quality Revised 2/22/16
I
i