HomeMy WebLinkAboutGW1-2021-03893_Well Construction - GW1_20210823 WELL CONSTRUCTION RECORD For Internal Use ONLY: This form can be used for single or mutiple wells F. R 1.Well Contractor Information: DESCRIPTION Sammy Rackley t. Well Contractor Name t3573-A G for u ti-case ells O Rif app ica lNC Well Contractor Certification Number DIAMETER THICKNES MATERIAL Lake Valley Well Co., Inc t 6.25 'n• .188 Steel-galvanized Company Name t in. O B G geot ermal c os op 2.Well Construction Permit#: W21-0114 FROM TO DIAMETER THICKNES MATERIAL List all applicable well construction pertmits ft County,State,Variance,etc. ft ft in. 3.Well Use: ft ft in. 7.SCa E FROM TO DIAMETER TMCKNES SLOTS MATERIAL Residential 50 ft ft in. °✓° ft ft. in. .9a•p,.s Al GRO !) 1Oti FROM TO MATERIAL EMPLACEMENT METHOD&AMOUNT • 1 ft ft Jf;'•i aQ� ft ft 1 r.• ft ft p icable FROM TO MATERIAL EMPLACEMENT METHOD&AMOUNT ft ft ft ft 4. Date Well(s)Completed: 7/29/2021 Well ID# ft ft 5a. Well Location: 20. G (a ch a itio a s eets if necessary. List all applicable well construction pertmits(le County,State,Variance,etc. FROM TO DESCRIPTION(color,hardness,soil/rock type,grain size,etc) Drees Homes 0 ft 25 ft Red Clay Facility/Owner Name Facility ID(if applicable) 25 ft 182 ft Gray Rock 1728 Eno Ridge DR Hillsborough 27278 Lot 17 Cates Landing ft ft Physical Address,City,and Zip ft ft Orange 9884318904 ft ft County Parcel Identification No.(PIN) ft ft 5b. Latitude and Longitude degrees/minutes/seconds or decimal degrees: ft ft (If well field,one lat/long is sufficient.) 21' 36.063591 N -79.054611 W Water zones at 110ft with 20gpm and at 160ft with 5gpm 6. Is(are)the well(s): Permanent 22. Certification: 7. Is this a repair to an existing well: No '�� 7 7/29/2021 If this is a repair,fill out known well construction information and explain the nature of the Signature of Certified Well Contractor Date repair under#21 remarks section or on the back of this form. By signing this form,I hereby certify that the well(s)was(were)constructed in accordance with 1 SA NCAC 02C.0100 or 15A NCAC 02C.0200 Well Construction Standards and that a 8. Number of wells constructed: 1 copy of this record has been provided to the well owner. For multiple injection or non-water wells ONLY with the same construction,you can 23. Site diagram or additional well details: submit one form. You may use the back of this page to provide additional well site details or well construction details. You may also attach additional pages if necessary. 9.Total well depth below land surface: 182 (M) For multiple wells list all depths if different(example-3@ 200'and 2 @ 100J SUMITTAL INSTRUCTIONS 10.Static water level below top of casing: 30 (ft) 24a.For All Wells: Submit this form within 30 days of completion of well construction to the following: � i If water level is above casing,use"+" Division of water Quality,Information Procession Unit, 11. Borehole diameter: 6 (in.) 1617 Mail Service Center,Raleigh,NC 27699-1617 12. Well construction method: Rotary air 24b.For Iniection Wells: In addtion to:Isending the form to the address in 24a (i.e.auger,rotary,cable,direct push,etc.) above,also submit a copy of this form within 30 days of completion of well construction to the following: FOR WATER SUPPLY WELLS ONLY: Division of Water Quality,Undergroun Injection Control Program, 1636 Mail Service Center,Raleigh,NC 27699-1636 13a. Yield(gpm): 25 Method of test: Air 24c.For Water Supply Infection Wells: In addtion to sending the form to the address(es)above,also submit one copy of this form within 30 days of 13b. Disinfection type: HTH Amount: 14 OZ completion of well construction to the county health department of the county where constructed. Form GW-1 North Carolina Department of Environment and Natural Resources - Division of Water Quality Revised 2/22/16 I