Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0032985_Regional Office Historical File Pre 2018
Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen 11. Sullins, Director Division of Water Quality May 14, 2008 Mr. Barry Shearin, Chief Engineer Charlotte Mecklenburg Utilities 5100 Brookshire Blvd. Charlotte, NC 28216 Subject: Permit No. WQ0032985 Griffith St. Pump Station Modifications Wastewater Collection System -Extension Mecklenburg County, North Carolina Dear Mr. Shearin, In accordance with your application received on April 25, 2008, we are forwarding herewith Permit No. W00032985, dated May 14, 2008, to Charlotte Mecklenburg Utilities for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403'or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. • Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper On e NCarolina ur'afllf I Fr Mr. Shearin Rage 2 May 13, 2008 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 28 linear feet of 18-inch gravity sewer, 25 linear feet of 8-inch gravity sewer , a 1,850 gallon per minute pump stations (with duplex pumps, on -site audible and visual high water alarm, and a permanent on -site generator with automatic transfer switch),and the discharge of 0 gallons per day of collected domestic wastewater into the Charlotte Mecklenburg Utilities existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996,-as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Charlotte Mecklenburg Utilities WWTP (McAlpine Creek NPDES No. NC0024970) prior to being discharged into the receiving stream. t Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Charlotte Mecklenburg Utilities. Charlotte Mecklenburg Utilities must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the WQCS00001 permit requirements. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Coleen H. Sullins cc: Mecklenburg County Land Use and Environmental Services Agency (LUESA) Steve Miller, CMU Philip Edward, Mecklenburg County Mooresville Regional Office, Collection System Permit File Charles Shue, McKim & Creed Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T 0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 28 .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 Pr. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5 Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life ofthe wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject 'the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting 'any of the above occurrences shall 'file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 14th day of May, 2008. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032985 3 Fast Track Engineering Certification Permit No. WQ0032985 May 14, 2008 OwneriWQCS PE Barry Shearin, Chief Engineer Charles Shue Charlotte -Mecklenburg Utilities McKim & Creed 5100 Brookshire Blvd 8020 Tower Point Drive Charlotte, NC 28216 Charlotte, NC 28227 WQCSMIWTP Steven Miller Charlotte Mecklenburg Utilities 5100 Brookshire Blvd. Charlotte, NC 28216 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer fines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or• minimum design criteria. . This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Griffith St. Pump Station Modifications, a Mecklenburg County project for the Permittee, hereby state that, to the best of *abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. and North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 0 2 USE THE TAB KEY TO MOVE FROM HELD TO FIELD! (to be completed by DWQ) Application Number: 1. OwnerfPermittee: la. Charlotte Mecklenburg Utilities Full Legal Name (company, municipality, HOA, utility, etc.) lb Barry Shearin, PE, Chief Enheer, Charlotte Mecklenburg_Utilities Signing Official Name and Title (Please review 15A NCAC 2T 0106 (b) forauthorized s ning o icials!) lc. The legal entity who will own this system is: 0 Individual 0 Federal Municipality 0 State/County 0 Private Partnership 0 Corporation 0 Other (specify): O ld. 5100 Brookshire Blvd le. Charlotte LL. Mailing Address City if NC lg. 28216-3371 Z State O 1h, 704-399-2221 1 704-393-2219 1j. Telephone Facsimile 2 Project (Faciii Information: 2a, Griffith St, Pump Station Modifications Brief Project Name (permit will refer to this name) 3. Contact Person: 3a, Brian Pate Name and Affiliation of Someone Who Can Answer Que 3b. 704-399-2221 Phone Number 1 Project is New 2. Owner is Zip Code bshearin@ci.charlotte.nc.us E-mail 2b, Mecklenburg County Where Proje- ct is Located ons About this Application 3c. bpate@ci,charlotte,nc.us E-mail 0 Modification (of an existing permit) If Modification, Permit No.: Public (skip to Item B(3)) 0 Private (go to Item 2(a)) 2a. If private, applicant will be: 0 Retaining Ownership (i.e. store, church, single office, etc) or 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) 2b. If sold, facilities owned by a must choose one) 0 Public Utility (Instruction C) 0 Homeowner Assoc./Developer (Instruction D) 3, Water and Sewer Authority of Cabarrus County (VVSACC) Z Owner of Wastewater Treatment Facility (VWVTF) Treating Wastewater From This Project O 4a. RockiRiver VVWTP 4b, NC0036269 1-- Name of VVVVTF VVvVIF Permit No, 5a, Charlotte Mecklenburg Utilities5b, 15" Gravity' 5c WQ203574 Owner of Downstream Sewer 'Receiving Sewer size 0 Force Main Permit # ot Downstream Sewer (Instruction E) 6, The origin of this wastewater is (check all that apply): Residential Subdivision Apartments/Condominiums 0 Mobile Home Park School Restaurant Office D Retail (Stores, shopping centers) 0 Institution 0 Hospital Church 0 Nursing Home 0 Other (specify): 100 % Domestic/Commercial % Industrial (attach description,) (RO: contact your Regional Office Pretreatment staff) % Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project: 0 gallons per day *Do not include future fiows er previously permitted allocations 8. If the permitted flow is zero, indicate why: Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No, 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FLA] 2/0 7_ver2 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) ANDIOR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional • Force Main W CI Z ' Design Flow Z (MGD) 0 0.. Z 0 0.533 18" 8" 28 ± If 25 ± If Gravity Gravity 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Pump,Station Location ID Proposed Pump Station (self chosen -.as shown on plans/map for reference) Operational Point GPM @TDH 1850 ©148 Power Reliability Option 1 - permanent generatorwlATS; 2 - portable generator w/MTS 1 Force Main Size 12" Force Main Length 3635 + If F Pump Station Location 1D Design Flow (MGD) 0,. L.L. ..._..__ Z Operational Point GPM @TDH (self chosen - as shown on planslmap for reference) Power Reliability Option 1 - permanent generator w/ATS; 2 - portable generator w/MTS Force Main Size Force Main Length re ;Pump Station Location ID W. CO Design Flow (MGD) Operational Point GPM @TDH (self chosen - as shown on planslmap for reference) Power Reliability Option 1 - permanent generator wIATS; 2 - portable generator wIMTS Force Main Size Force Main Length 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ❑ Yes ® No If Yes, permit number of 2nd treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 113. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA12/07_ver2 14. Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Stormwater? ❑ Yes ❑ No ® Yes ❑ No ❑ Yes ❑ No ® N/A ❑ N/A ® N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details OwnerlPermittee's Certification: (Signature of Signing Official and Project Name) 1, Barry Shearin, PE, attest that this application for the Griffith Street Pump Station Modifications has been reviewed by me and is accurate and complete to the best of my knowledge. ! understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143- 215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10, 000 as well as civil penalties up to $25, 000 per violation. Signing Official Signature Date 'ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 Z 1 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, Charles E. Shue, PE, attest that this application for the Griffith Street Pump Station Modifications has been reviewed by LL me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed Ce design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for W Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump V Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judgedit to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a tine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. ci 2a. Charles E. Shue, PE Professional Engineer Name 2b. McKim & Creed Engineering Firm 2c. 8020 Tower Point Drive Mailing Address 2d. Charlotte 3 City 2g. 704-841-2588 2h. 704-841-2567 2i. cshue@mckimcreed.com Telephone Facsimile e. NC 12f. 28227 State Zip E-mail ,,tu tiCiA,,,,,, SSio '1.1 _rs -�"A I- • ES, ,,,, ,, V NC PE Seal, Signature & Date FTA12/07 ver2 'FORM WSCAS-12/07 WATERSHED CLASSIFICATION ATTACHMENT FOR SEWER SYSTEMS Applicant Name Charlotte Mecilenburg Utilities Professional Engineer Name Charles E. Shue, PE Location ID Project Nam Griffith St, Pump Station Modifications Engineering Firm Name McKim & Creed Name of Waterbody' Catawba River River Waterbody Stream Waterbody Count Basin Index No. Classification Mecklenburg Catawba 11 - (75) W S-IV,E :CA unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary goi I certify that as a Registered Professional Engineer in the State of North Carolina that I have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief, PE Seal, Signature and Date ** END OF FOR, W'SC.AS- FORM: WSCAS-12/07 GRIFFITH ST PUMP STATION MODIFICATIONS CHARLOTTE MECKLENBURG UTILITIES 200 400 800 1,200 1 inch equals 600 feet 1,600 Feet &CREED April 24, 2008 Ms, Dee Browder Mooresville Regional Office, Division of Wate North Carolina Department of Environment a 610 East Center Avenue, Suite 301 IMooresville, North Carolina 2811.5 014320019(40) APR 2 r ;-;;;41„ 0n i RE: Fast -Track Application Griffith Street Pump Station NC DENR MR0 Charlotte Mecklenburg Utilities DWQ-Surface Water Protection Dear Ms, Browder, Enclosed please find one original and one copy of the completed Fast -Track Application and a check for the application fee for the Griffith Street Pump Station in Davidson. The application indicates a permitted flow of zero wastewater for this project. Future wastewater flow generated in the service area will be assigned to the specific future projects as they develop. 'Therefore,. per your instructions, neither flow- calculations nor Form FTSE-10/07, HOW Tracking/Acceptance for Sewer Extension Permit Application., are included for either CMU or WSACC The new force main for the Griffith Street Pump Station was previously permittedunder permit number \VQ0030600. Please review the above and if you have any questions or comments, do not hesitate to call me at 704-841-2588. Very truly yours, Me_1(1114 & CREED, PA. CALA-A:- K Charles E. Shue, PE Senior Project Manager pc: Brian Pate, Charlotte Mecklenburg Utilities ' w Central Files: APS SWP^ 05/13/08 Permit Number WQ0032985 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 0 Facility Facility Name Griffith Street Pump Station Modifications Location Address Owner Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Owner Type Charlotte Mecklenburg Utilities Government - County Dates/Events Owner Affiliation Barry Shearin, PE 5100 Brookshire Blvd Charlotte NC 28216 Orig Issue App Received 05/14/08 04/25/08 Draft Initiated Scheduled Issuance Public Notice issue Effective Expiration 05/14/08 05/14/08 Regulated. Activities Reauested/Received Events Apartment complex Church Condominium Restaurant School Wastewater collection Outfall NULL Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin East Track Engineerincl Certi Permit No, WQ0032985 y 14, 2008 OwnerMlQCS Barry Shearin, Chief Engineer Charlotte -Mecklenburg utilities 5100 Brookshire Blvd Charlotte, NC 28216 n PE Charles Shue McKim & Creed 8020 Tower Point Drive Charlotte, NC 28227 WQCSiWWTP Steven Miller Charlotte Mecklenburg Utilities 5100 Brookshire Blvd. Charlotte, NC 28216 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Pe modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial D Final r Cke,Pk', 5h J , as a duly registered Professional Engineer in the State of North Carolina, having been .horized to observe periodically, [j weekly, © full time) the construction of Griffith St. Purnp Station Modifications, a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit 15A NCAC 27; the Division of Water Quality's (Division) Gravity Sewer 'Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: ErsutO SEND THIS FORM & SUPPORTING DOCUMENTATION WiTH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, Fast Track Engineering Certification Perrnit No. WQ0032985 May 14, 2008 Owner!WQCS PE Barry Shearin, Chief Engineer Charles'Shue Charlotte -Mecklenburg Utilities McKim & Creed 5100 Brookshire Blvd 8020 Tower Point Drive Charlotte, NC 28216 Charlotte, NC 28227 WQCSNUWIP Steven Miller Charlotte Mecklenburg Utilities 5100 Brookshire Blvd. Charlotte, NC 28216 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or • minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION IN/Partial ❑ Final 3 Ch��ks e.. Sh- e- , as a duly registered Professional Engineer in the State of North Carolina, having been .horiaed to observe periodically, ❑ weekly, ['full time) the construction of Griffith St. Pump Station Modifications, a Mecklenburg County project for the Permittee, hereby state that, to the best of my` abilities, due care and diligence was used in the observation of the construction such that the construction was observed td tie built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer 'Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. • North Carolina Professional Engineer's seal, signature, and date: - . • .. i ...:4 "of P- `SRO': Jul!, -?Q ,2: A�, - /42 • • hi 1 SEND THIS FORM &, SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this . Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Charlotte Mecklenburg Utilities Town of Davidson Griffith St. Pump Station Pump Station Design Calculations Engineering Report WQ0032985 Charlotte Mecklenburg Utilities Town of Davidson Griffith St. Pump Station Pump Station Design Calculations Engineering Report Design Flows Average Design Flows (ADF) ADF = 370 gpm Pumping Rate (QPS) QPS = 1850 gpm Wet Well Design Volume Where: Tc = Pump cycle time (minutes) V = Volume of the Wet Well (cubic feet) Scenario 1. Build Out Flows V = Tc *ADF*(1-(ADF/PDF)) per NCDENR requirements Tc ADF*(1-(ADF!QPS)) V= 12.0 x 296.00 = 3552.00 gal Cycles per Hour Where: Tf = Wet Well fill time (minutes) Tr = Pump run time (minutes) Tc = Total pump cycle time C = Cycles per hour V ADF Tf = 3552.00 ! 370.00 = 9.60 minutes V (PDF- ADF) Tr= 3552.00 / 1480.00 = 2.40 minutes Tc = Tf + Tr = 12.00 minutes C = 60 minutes / Tc = 5.00 cycles per hour Wet Well Sizing WET WELL Dimensions 12.00 18.33 Area (t) 219.96 STORAGE DEPTH (ft) BASED ON EFFECTIVE VOLUME 0.35 27.00 42.00 1134.00 Wet Well Control Settings Pump Station Top High Water Alarm Lag Pump On Lead Pump On Pump(s) Off Low Water Alarm Influent Sewer Invert Wet Well Floor Wet Well Bottom Depth (ft. ) 1.45 15.17 0.50 0.50 0.50 0.50 1.50 0.50 1.50 Elevation (ft.) 765.45 750.28 749.78 749.28 748.78 748.28 746.78 746.28 744.78 Design allows 2.50' from "Pump(s) Off' elevation to 'Wet Well Bottom" elevation. "Suction Intake" elevation shall be set for pumps supplied. supplied. Consult manufacturers specifications. Total Pump Station Depth = 20.67 ft McKim and Greed ProJec1 No. 1432-0019 Page 1 3/26/2010 Pump Selection & Design General Design Parameters -- Pumping Rate Force Main Size: - Force Main Velocity= TDH=Hm+Hv+Hf+Hs where: 1850.00 gpm 12 inch 5.25 ftfs Hm =Minor Losses Hv = Velocity Head Hf =Friction Losses Hs = Static Head Static Head Hs = Highest Force Main Elevation - Pump Off Elevation -- Highest FM Elev. = Hs = 820 - 748.78 = 71.22 feet 820 feet Hs = 71.22 feet Equivalent Unit Lengths of Fittings and Piping Equivalent 8 inch Diameter Piping PS Suction Fittings 8" Bell PS Suction Piping No. Unit L Total L 1.60 1.60 Suction Fittings and Piping Total 1.60 PS Discharge Fittings 8" Check Valve 1 80.0 80.00 6" Plug Valve 2 12.5 25.00 8" 45 Bend 2 4.2 8.40 8" 90 Bend 2 8.8 17.60 8" Tee Branch 1 40.0 40.00 8" Tee Line 1 13.3 13.30 P5 DiScharne Pining 8" DIP 1 50.0 50.00 FM Pining All Fittings and Piping Total 235.90 Equivalent 12 inch Diameter Piping Fittings No. Unit L Total L PS Suction Fittings PS Suction Pining Suction Fittings and Piping Total 0.00 PS Discharge Fittings PS Discharge Piping FM Fittings 12' x 8" Reduce 1 20.8 20.80 12" 90 Bend 4 16.5 66.00 12' 45 Bend 8 5.3 42.40 12" 22.5 Bend 5 2.6 13.00 12" 11.25 Bend 2 1.7 3.40 FM Piping 12" DIP 1 3625 3966 All Fittings and Piping Total 4111.60 McKim and Creed Project No. 1432-0019 Page 2 3282010 • Minor Losses for Suction Piping at Design Flow Hazen -Williams Friction Factor = 100 Q gpm 1850 L (ft) 8 inch Diameter Piping 1.60 hU. -100 ft 9.253 Hf (ft) 0.15 Total Hss (ft) 0.15 Net Positive Suction Head Available NPSHa = where: ha+hss - hfs -hvp= 35.46 ft ha = Atmospheric Pressure of Water at Mean Sea Level = hss = Suction Static Head (Pumps Off Elevation - Volute CI Elevation) = hfs = Minor Losses for Suction Piping at Design Flow = hvp = Vapor Pressure for Water at 60d F Minor Losses for Minimum Condition Hazen -Williams Friction Factor = 125 33.9 ft 2.30 ft 0.15 ft 0.59 ft Q gpm 8 inch Diameter Piping 12 inch Diameter Piping Total Hf (ft) L (ft) h\L -100 ft Hf (ft) L (ft) MI_ -100 ft Hf (ft) 0 235.90 0.000 0.00 4111.60 0.000 0.00 0.00 400 235.90 0,359 0.85 4111.60 0.050 2.05 2.89 800 235.90 1.296 3,06 4111.60 0,180 7,39 10,45 1200 235.90 2.746 6.48 4111.60 0.381 15.67 22.14 1600 235.90 4.678 11.04 4111.60 0.649 26.69 37.73 2000 235.90 7.072 16.68 4111.60 0.981 40.35 57.03 1850 235.90 6.121 14.44 4111.60 0.849 34.92 49.36 2400 235.90 9,912 23.38 4111,60 1,376 56.56 79.94 2800 235.90 13.187 31.11 4111.60 1.830 75.24 106.35 Minor Losses for Maximum Condition Hazen -Williams Friction Factor = 100 Q gpm 8 inch Diameter Piping 12 inch Diameter Piping Total Hf (ft)_ L (ft) h1L -100 ft HT (ft) L (ft) h1L -100 ft _ _ Hf (ft) 0 235,90 0,000 0.00 4111.60 0.000 0.00 0.00 400 235.90 0.543 1.28 4111.60 0.075 3.10 4.38 800 235.90 1.959 4.62 4111.60 0.272 11.18 15.80 1200 235.90 4.151 9.79 4111.60 0.576 23.68 33.48 1600 235.90 7.072 16.68 4111.60 0.981 40.35 57.03 2000 235.90 10.691 25.22 4111.60 1.464 61.00 86.22 1850 235.90 9.253 21.83 4111.60 1.284 52.80 74.63 2400 235.90 14.985 35.35 4111.60 2.079 85.50 120.85 2800 235.90 19.936 47.03 4111.60' 2.767 113.75 160.78 Minimum Head Conditions FM Piping = 12 inches PS Piping = 8 inches Suct. Inlet = 8 inches C= 125 Minor Losses Force Main Static Q gpm Hm ft Velocity fps Hy • ft. Hs ft. TDH ft. 0 0.00 0.00 0.00 71.22 71.22 400 2.89 1.13 0.10 71.22 74.22 800 10.45 2.27 0.40 71.22 82.08 1200 22.14 3.40 0.91 71.22 94.27 1600 37.73 4.54 1.62 71.22 110.57 2000 57.03 5.67 2.53 71.22 130,76 1850 49.36 5.25 2.17 71.22 122,75 2400 79.94 6.81 3.64 71.22 154.80 2800 106.35 7.94 4.98 71.22 182.53 McKIm end Creed Protect No. 1432.0019 Page 3 3/26/2010 Maximum Head Conditions FM Piping = PS Piping = Suct. Inlet = C= 12 inches 8 inches 8 inches 100 Minor Losses Force Main Static Q gpm Hm ft Velocity fps Hv' _ ft. Hs ft. TDH ft. 0 0.00 0.00 0.00 71.22 71.22 400 4.38 1.13 0.10 71.22 75.70 800 15.80 2.27 0.40 71.22 87.42 1200 33,48 3,40 0.91 71.22 105.61 1600 57,03 4,54 1.62 71.22 129.87 2000 86.22 5.67 .2,53 71.22 159.97 1850 74.63 5.25 2.17 71.22 148.01 2400 120.85 6.81 3.64 71.22 195.71 2600 160.76 7.94 4.96 71.22 236.96 Velocity Head taken at PS Suction Inlet System Head Curves Minimum Maximum Q gpm TDH FT TDH FT 0 71.22 71.22 ' 400 74.22 75.70 800 82.08 87.42 1200 94.27 105,61 1600 110.57 129.87 2000 130.78 159.97 2400 154.80 195.71 2800 182.53 236.96 Brake Horse Power BHP = (gpm * TDH ` sg) / (3950 * Pe) = where: Velocity min flow = max flow = Pump Curves Q gpm 1800 RPM FT 0 243.70 400 220.30 800 199.80 1200 180.10 1600 160.50 2000 143.00 2400 127.40 2800 109.00 gpm = design flow = TDH =Total Dynamic Head sg = Specific Gravity of water at 60d F. = Pe = Pump Efficiency = FM Piping = PS Piping 370.00 gpm 1850.00 gpm min vel. = max vex. = 90.42 HP 1850 gpm 148.01 ft 0.999 76.4 % 12 inches 8 inches 12" FM 8" PS 1.05 ft/s 5.25 ft!s 2.36 ft/s 11.81 ft/s Operating Point Q TDH gpm FT 1850 148.01 Pump Selection 8" CP3300 350 mm Imp. Flygt- Curve 63-460 NPSHr= NPSHa= 30.80 ft 35.46 ft McKim and Creed Project No. 1432-0019 Page 4 3126/2010 300 250 .� 200 u_ c 150 w 100 50 PUMP AND SYSTEM HEAD CURVES - 12" FM - TDH (MIN) C=125 - TDH(MAX) C=100 — 0-1800 RPM A Design Point MII=O1111=1. ="Maitil• 0 400 800 1200 1600 GPM 2000 2400 2800 Bouancy Calculations Dia. Thickness Height Area Volume Density Weight (ft) (ft) (ft) (ft42) (ft"3) (Iblft°3) (lips) wet well top 9 1 63.62 63.62 150 9,543 slab wet well walls wet well bottom slab soil overburden Water Displaced wet well walls wet well bottom slab 9 11 11 9 11 1 16.15 13.35 215.63 150 32,345 2 95.03 190.07 150 28,510 2 15.15 31.42 475.95 37.6 17,896 '(Assume groundwater level at surface) 88,293 15.15 63.62 964 62.4 60,141 2 95.03 190 62.4 11,860 72,001 Difference between wet well self weight with soil overburden and water displaced. = 16,292 (Ibs) Factor of Safety = 1.23 McKim and Creed Project No. 1432-0019 Page 5 Certified Performance Curves The following curve shows predicted flow for the pump/impeller combination shown. Certified factory performance curves will be submitted for approval prior to the pumps leaving the factory. FLYGT PERFORMANCE CURVE PRODUCT CP3300 /605 TYPE HT DATE 2009-06-09 PROJECT CMUD-Griffith Street Station Rehab Protect Number 359-05542 CURVE NO 63-460 ISSUE 8 _ POWER FACTOR I EFFICIENCY MOTOR DATA 1/1-LOAD 0.84 93.5 % — 3/4-LOAD 0.80 94.5 % — 1/2-LOAD 0.71 95.0 % — PRATED DR 100 h STARTING P CURRENT ... 560 A CURRENT ... 120 A RATED SPEED TOT.MOM.OF 1775 rpm INERTIA ... 0.89 kgm2 NO. OF BLADES 2 IMPELLER DIAMETER 350 mm MOTOR # STATOR 35-29-4AA 101 D REV 12 FREQ. 60 Hz PHASES 3 a VOLTAGE 460 V POLES 4 COMMENTS INLET OUTLET -/ 6 inch GEARTYPE RATIO -- I -- IMP. THROUGHLET 3.0 inch a F5 [hp] 100 r J — r r 1 - f DVERALL EFF. 0 INPUT POWE 'UMP EFF. * SHAFT POWs Et 1 � 80 O ------------------- 60 CL. 40 . DUTY -POINT FLOW(usgpm) HEAD[ft] POWER [hp] EFF. [%] NPSHre]ft] 1 1880 148 97.9 (92.1) 71.9 (76.5) 31.3 B.E.P. 2157 137 104 (97) 72.4 (77.1) 36.0 0 . NPSHre 1- [ft] [ft] o 1 120 — w 16 w m 0 240 I- Q- 100 —EFF. 200 [%] 80 -- 80 Q160 W -----1 P 70 2 � ---- = .4— 7- 60 60 120 ` ""-.-- 50 40 40 80 — 30 20 1 20 40 —10 0 0 0 0 500 1000 1500 2000 2500 [USgpm] FLOW NPSHre = NPSH3% + min. operational margin Performance with clear water and ambient temp 40 °C FLYGT HI B Cu rve Charlotte Mecklenburg Utilities Town of Davidson Griffith St. Pump Station Pump Station Design Calculations Engineering Report WQ0032985 •`pPSH Cq/R.?,f? : n , .Q` -V: " Charlotte Mecklenburg Utilities Town of Davidson Griffith St. Pump Station Pump Station Design Calculations Engineering Report Design Flows Average Design Flows (ADF) ADF = 370 gpm Pumping Rate (QPS) QPS = 1850 gpm Wet Well Design Scenario 1. Build Out Flows Volume Where: Tc = Pump cycle time (minutes) V = Volume of the Wet Well (cubic feet) V = Tc *ADF*(1-(ADF/PDF)) per NCDENR requirements Tc ADF*(1-(ADF/QPS)) V = 12.0 x 296.00 = 3552.00 gal Cycles per Hour Where: Tf = Wet Well fill time (minutes) Tr = Pump run time (minutes) Tc = Total pump cycle time C = Cycles per hour V ADF Tf = 3552.00 / 370.00 = 9.60 minutes V (PDF- ADF) Tr= 3552.00 / 1480.00 = 2.40 minutes Tc = Tf + Tr = 12.00 minutes C = 60 minutes / Tc = 5.00 cycles per hour Wet Well Sizing WET WELL Dimensions 12.00 18.33 Area (ft') 219.96 STORAGE DEPTH (ft) BASED ON EFFECTIVE VOLUME 0.35 27.00 42.00 1134.00 Wet Well Control Settings Pump Station Top High Water Alarm Lag Pump On Lead Pump On Pump(s) Off Low Water Alarm Influent Sewer Invert Wet Well Floor Wet Well Bottom Depth (ft. ) 1.45 15.17 0.50 0.50 0.50 0.50 1.50 0.50 1.50 Elevation (R.t 765.45 750.28 749.78 749.28 748.78 748.28 746.78 746.28 744.78 Design allows 2.50' from "Pump(s) Off' elevation to "Wet Well Bottom" elevation. "Suction Intake" elevation shall be set for pumps supplied. supplied. Consult manufacturers specifications. Total Pump Station Depth = 20.67 ft McKim and Creed Project No. 1432-0019 Page 1 3/2612010 Pump Selection & Design General Design Parameters - Pumping Rate = - Force Main Size: - Force Main Velocity= TDH=Hm+Hv+Hf+Hs where: 1850.00 gpm 12 inch 5.25 ft/s Hm =Minor Losses Hv = Velocity Head Hf =Friction Losses Hs = Static Head Static Head Hs = Highest Force Main Elevation - Pump Off Elevation -- Highest FM Elev. = 820 feet -- Hs = 820 - 748.78 = 71.22 feet Hs = 71.22 feet Equivalent Unit Lengths of Fittings and Piping Equivalent 8 inch Diameter Piping PS Suction Fittings 8' Bell PS Suction Piping No. Unit L Total L 1 1.60 1.60 Suction Fittings and Piping Total 1.60 PS Discharge Fittings 8" Check Valve 1 80.0 60.00 8" Plug Valve 2 12.5 25.0D 8" 45 Bend 2 4.2 8.40 8" 90 Bend 2 8.6 17,60 8" Tee Branch 1 40.0 40.00 8" Tee Line 1 13.3 13.3D PS Discharge Piping 8" DIP 1 50,0 50,00 FM Piping Alt Fittings and Piping Total 235.90 Equivalent 12 inch Diameter Piping Fittings No. Unit L Total L PS Suction Fittings PS Suction Piping Suction Fittings and Piping PS Discharge Fittings PS Discharge Piping FM Fittings Total 0.00 12" x 6" Reduce 1 20.8 20.80 12' 90 Bend 4 16.5 66.00 12" 45 Bend 8 5.3 42.40 12" 22.5 Bend 5 2.6 13.00 12" 11,25 Bend 2 1.7 3.40 FM Piping 12" DIP 1 3625 3966 All Fittings and Piping Total 4111.60 Maim and Creed Project No. 1432-0019 Page 2 3252010 Minor Losses for Suction Piping at Design Flow Hazen -Williams Friction Factor = 100 Q gpm 8 inch Diameter Piping Total Hss (ft) L (ft) h1L -100 ft Hf (ft) 1850 1.60 9.253 0.15 0.15 Net Positive Suction Head Available NPSHa = ha + hss - hfs - hvp where: 35.46 ft ha = Atmospheric Pressure of Water at Mean Sea Level hss = Suction Static Head (Pumps Off Elevation - Volute CI Elevation) _ hfs = Minor Losses for Suction Piping at Design Flow = hvp = Vapor Pressure for Water at 60d F Minor Losses for Minimum Condition Hazen -Williams Friction Factor = 125 33.9 ft 2.30 ft 0.15 ft 0.59 ft Q gpm B inch Diameter Piping 12 inch Diameter Piping Total HT (ft) L (ft) h1L -100 ft Ht (ft) L (ft) h1L -100 ft Hf (ft) 0 235.90 0.000 0.00 4111.60 0.000 0.00 0.00 400 235.90 0.359 0.85 4111.60 0.050 2.05 2.89 800 235.90 1.296 3.06 4111.60 0.180 7.39 10.45 1200 235.90 2.746 6,48 4111.60 0.381 15.67 22.14 1600 235.90 4.578 11.04 4111.60 0.649 26.69 37.73 2000 235.90 7.072 16.68 4111.60 0.981 40.35 57.03 1850 235.90 6.121 14.44 4111.60 0.849 34.92 49.36 2400 235.90 9.912 23.38 4111.60 1,376 56.56 79.94 2800 235.90 13.187 31,11 4111.60 1.83D 75.24 105.35 Minor Losses for Maximum Condition Hazen -Williams Friction Factor = 100 Q gpm 8 inch Diameter Piping 12 inch Diameter Piping Total Ht (ft) L (ft) h1L -100 ft Hf (f1) L (ft) htL -100 ft Hf (ft) 0 235.90 0.000 0.00 4111.60 0.000 0.00 0.00 400 235.90 0.543 1.28 4111.60 0.075 3.10 4.38 800 235.90 1.959 4.62 4111.60 0.272 11.18 15.80 1200 235.90 4.151 9.79 4111.60 0.576 23.68 33.48 1600 235.90 7.072 16.68 4111.60 0.981 40.35 57.03 2000 235.90 10.691 25.22 4111.60 1.484 61.00 86.22 1850 235.90 9.253 21.83 4111.60 1.284 52.80 74.63 2400 235.90 14.985 35.35 4111.60 2.079 85.50 120.85 2800 235.90 19.938 47.03 4111.69 2.767 113.75 160.78 Minimum Head Conditions FM Piping = 12 inches PS Piping = 8 inches Suct. Inlet = 8 inches C= 125 Minor Losses Force Main Static Q gpm Hm ft Velocity fps Hy' ft. Hs ft. TDH ft. 0 0.00 0.00 0.00 71.22 71.22 400 2.89 1.13 0.10 71.22 74.22 800 10.45 2,27 0.40 71.22 82.08 1200 22.14 3.40 0.91 71.22 94.27 1600 37.73 4.54 1.62 71.22 110.57 2000 57.03 5.67 253 71.22 130.78 1650 49.36 5.25 2.17 71.22 122.75 2400 79,94 6.81 3.64 71.22 154.80 2800 106,35 7.94 4.95 71.22 182.53 McKim and Creed Project No. 1432.0019 Page 3 3126/2010 • .F Maximum Head Conditions FM Piping = 12 inches PS Piping = 8 inches Suet. inlet = 8 inches C= 100 Minor Losses Force Main Static Q gpm Hm 8 Velocity fps Hv' ft. Hs ft. TDH ft. 0 0.00 0.00 0.00 71.22 71.22 400 4.38 1.13 0.10 71.22 75.70 800 15.80 2.27 0.40 71.22 87.42 1200 33.48 3.40 0.91 71.22 105.61 1600 57.03 4.54 1.62 71.22 129.87 2000 86.22 5.67 2.53 71.22 159.97 1650 74.63 5.25 2.17 71.22 146.01 2400 120.85 6.61 3.64 71.22 195.71 2800 160.78 7.94 4.96 71.22 236.96 Velocity Head taken at PS Suction Inlet System Head Curves Minimum Maximum Q gpm TDH FT TDH FT 0 71.22 71.22 400 74.22 75.70 800 82.08 87.42 1200 94.27 105.61 1600 110.57 129.87 2000 130.78 159.97 2400 154.80 195.71 2800 152.53 236.96 Brake Horse Power BHP = (gpm *TDH • sg) / (3960 " Pe) = where: Velocity min flow = max flow Pump Curves 0 gpm 1800 RPM . FT 0 243.70 400 220.30 800 199.80 1200 180.10 1600 160.50 2000 143.00 2400 127.40 2800 109.00 gpm = design flow = TDH =Total Dynamic Head = sg = Specific Gravity of wafer at 60d F. _ Pe = Pump Efficiency = FM Piping = PS Piping = 370.00 gpm 1850.00 gpm 90.42 HP 1850 gpm 148.01 ft 0.999 76.4 % 12 inches 8 inches 12" FM 8" PS min vel. = 1.05 Ws Max vel. = 5.25 Ws 2.36 ft/s 11.81 ills Operating Point Q TDH gpm FT 1850 148.01 Pump Selection 8" CP3300 350 mm Imp. Flygt- Curve 63-460 NPSHr = NPSHa= 30.80 ft 35.46 ft McKim and Greed Project No. 1432-0019 Page 4 3262010 300 250 1- 200 Q 150 w x 100 50 0 0 PUMP AND SYSTEM HEAD CURVES - 12" FM 400 800 1200 1600 GPM 2000 2400 —ER—TDH (MIN) C=125 ---TDH(MAX) C=100 —0-1800 RPM A Design Point 2800 Bouancy Calculations IDia. Thickness Height Area Volume Density Weight (ft) (ft) (ft) (ftA2) (ft"3) (Iblft"3) (lbs) wet well top 9 - 1 63.62 63.62 150 9,543 slab wet well walls wet well bottom slab soil overburden Water Displaced wet well walls wet well bottom slab 9 11 11 9 11 1 16.15 13.35 215.63 150 32,345 2 95.03 190.07 150 28,510 2 15.15 31.42 475.95 37.6 17,896 88,293 '(Assume groundwater level at surface) 15.15 63.62 964 62.4 60,141 2 95.03 190 62.4 11,860 72,001 Difference between wet well self weight with soil overburden and water displaced. = 16,292 (Ibs) Factor of Safety = 1.23 McKim and Creed PrcJect No. 1432-0019 Page 5 3126l200 Certified Performance Curves The following curve shows predicted flow for the pump/impeller combination shown. Certified factory performance curves will be submitted for approval prior to the pumps leaving the factory. FLVGT PERFORMANCE CURVE PRODUCT CP 3300 /605 TYPE HT DATE 2009-06-09 POWER FACTOR EFFICIENCY MOTOR DATA PROJECT CMU17-Griffith Street Station Rehab Project Number 359-05542 1/1-LOAD 0.84 93`5 % 3/4-LOAD 0.80 94.5 % 112-LOAD 0.71 95.0 % COMMENTS INLET/OUTLET -1 6 inch IMP. THROUGHLET 3.0 inch RATED POWER 100 hp STARTING CURRENT ... 560 A RATED CURRENT ... 120 A RATED SPEED 1775 rpm TOT.MOM.OF INERTIA... 0.89 kgm2 NO, OF BLADES 2 CURVE NO 63-460 IMPELLER DIAMETER 350 mm ISSUE 8 MOTOR# STATOR REV 35-29-4AA 101 D 12 FREQ. 60 Hz PHASES 3 VOLTAGE 460 V POLES 4 GEARTYPE RATIO [h p] 100 80 O 60 40 1 r DUTY -POINT 1 B.E.P. [ft] 240 200 FLOW[USgpm] 1880 2157 HEAD[ft] 148 137 POWER [hp] 97.9 (92.1) 104 (97) EFF. I%] NPSHre[tt] 71.9 (76.5) 31.3 72.4 (77.1) 36.0 NPSHre 2000 Ow H re=36-f. . of [ft] 120 0 OVERALL EFF. E- J rQ- 100 _EFF. F. 80-80 4 70 .1 0-60 2500 `�-50 40 — 40 -- 30 20 — 20 —10 0-0 [USgpm] ul R i'r �r.►a March 26, 2010 Ms.. Dee Browder Mooresville Regional Office,.Division of Water Surface Water Protection, NCDENR 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 0 1 4 3 2 0 0 4 :1 ( 4 0 ) :RE: Partial Engineering Certification - Permit No, WQ0032895 Griffith Street Pump Station - Charlotte Mecklenburg Utilities Dear ,Ms. Browder, Enclosed please find the original Fast -Track Engineering Certification for the Griffith Street Pump Station (Permit No. WQ0032895). Also enclosed are supporting design calculations for the pump station. 'Two copies of the project record drawings will be Submitted upon final completion/final certification, This is a partial certification for the pump stattofl which is fully operational; however, a number of site related issues which do not affect the operation of the facility still need attention. We are providing this partial certification in order to discontinue the temporary by-pass pumping and allow the permanent pump station to operate in automatic mode. The on -site generator is fully operational so back-up power is available. Please review the above and if you have any questions or comments, do not hesitate to call me at 704-841-2588. I Very truly yours, McK1M & CREED, P.A. Charles E, Shue, PE Senior Project Manager nf; "0; Ote Pc: Brian Pate, Charlotte Mecklenburg Utilities Dennis Gwaltney, f5r7,-ttr.t117'Ivitecklenburg Utilities Stuart Rosenberger, Charlotte Mecklenburg Utilities Fast Track Engineering Certification Permit No, W00032985 May 14, 2008 OwnerfWQCS PE Barry Shearin, Chief Engineer Charles Shue Charlotte -Mecklenburg Utilities McKim & Creed 5100 Brookshire Blvd 8020 Tower Point Drive Charlotte, NC 28216 Charlotte, NC 28227 WQCSNW TP Steven Miller Charlotte Mecklenburg Utilities 5100 Brookshire Blvd. Charlotte, NC 28216 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension +► Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected y for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required For any changes resulting in non-compliance with this permit, regulations or rinimura design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, ENGINEER'S CERTIFICATION U Partial 'Final Cinartta E. 5 ktA , as a duly registered Professional Engineer in the State of North Carolina, having been A4..horized to observe (periodically, El weekly, El full time) the construction of Griffith St. Pump Station Modifications, a Mecklenburg County project for the Permittee, hereby stale that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date:. _._ nmatio C�ffiAr' SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. )b 0 DIVISION OF WATER QUALITY Dec 1taa der - 0ff3e, Surfrlce titer ion•, NCI NR 610'East Center.Aveuut uit 01 1 1oore'vi11e, forth (arohn a ' 115 1PiENAL Fngineerirtg Certification: ir.LE REGIONAL 432004 1 0) No, WQ0Cl52895 iftitla St . c t I'trnap Station -- Cho rlcatte Heckler bur f Ct egar \1;. Brofsis, [rocTo:;td Iair=°r + rectPun cord d rya her anal Fa Track 11 ra rnnr Certi an (I er ait No, ' 00 2S 5) and one c Supporting design calculations- for the pump station 1 a >itla the partial certific atican can 1\'`T<art h 26, 2010, and if yf have any fittest' at 04-41-2558, titicKIM Sic CREED, , T',A, tor ject ccamrneaatr , do n IC.: Brian 1' rtr "li ar cattc: ecl lcialarr tint enrai °altar t, I' P (harlottc ;\Flecklech rr�t; CTt Stuart Rost raberr,er°, Ch arlsatte 1�Iec I lentaur C ftilit;