HomeMy WebLinkAboutNC0084387_Compliance Evaluation Inspection_20211101ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
S. DANIEL SMITH NORTH CAROLINA
Director Environmental Quality
November 1, 2021
Gabe Sasser, Operations Manager
Charlotte Water
5200 Brookshire Blvd.
Charlotte, North Carolina 28216
Subject: Compliance Evaluation Inspection
Charlotte Water/Lee S. Dukes WTP
NPDES Permit No. NC0084387
Mecklenburg County
Dear Mr. Sasser:
Enclosed is a copy of the Compliance Evaluation Inspection (CEI) Report for the inspection conducted at the subject
facility on October 28, 2021, by Mr. Wes Bell of this Office. Please advise the facility's Operator -in -Responsible Charge
(ORC) of our findings by forwarding a copy of the enclosed report.
Should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192,
or via email at wes.bell@ncdenr.gov.
Enclosure: Inspection Report
NORTH
D penment of Environmental Onont —
Sincerely,
r--DocuSigned by:
'-A14CC681AF27425...
W. Corey Basinger, Regional Supervisor
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ
North Carolina Department of Environmental Quality 1 Division of Water Resources
Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115
704.663.1699
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code
1 IN I 2 I5
21 1 1 1 1 1
NPDES yr/mo/day Inspection
I 3 I NC0084387 111 121 21/10/28 117
Type
18 i i
I I 1 1 1
Inspector Fac Type
191 S I 201
1 1 1 1 11 1 1 1 I I I 1 1 1 1 1 1 I I I I I
1 11
1 1 1 I 1 P6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
67I2.0 I 70I4 I 71IN I 72 I N I 731 I 74 751
I I 1
I I I I I I 180
l
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES oermit Number)
Lee S. Dukes WTP
7980 Babe Stillwell Farm
Huntersville NC 28078
Entry Time/Date
12:50PM 21/10/28
Permit Effective Date
20/08/01
Exit Time/Date
02:OOPM 21/10/28
Permit Expiration Date
25/02/28
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
David M Banick/ORC/704-399-2426/
Gabe Sasser//704-399-2142 /
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Angela Charles,4222 Westmont Dr Charlotte NC 282171030//704-336-5911/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s)
Wes Bell
of Inspector(s) Agency/Office/Phone and Fax Numbers Date
�Docusigned by: DWR/MRO WQ/704-663-1699 Ext.2192/ 11/1/2021
'-A61696D90CC3437...
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W. Corey Basinger DWR/Division of Water Quality/704-235-2194/
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
DocuSigned by:
11/1/2021
"-A14CC681AF27425...
Page# 1
NPDES yr/mo/day
31 NC0084387 111 121 21/10/28
I17
Inspection Type
18 [j
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page# 2
Permit: NC0084387
Inspection Date: 10/28/2021
Owner - Facility: Lee S. Dukes WTP
Inspection Type: Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new El El ❑
application?
Is the facility as described in the permit? • El El El
# Are there any special conditions for the permit? El El • El
Is access to the plant site restricted to the general public? • ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? • El El El
Comment: The last compliance evaluation inspection at the facility was performed by DWR staff
on 10/22/19.
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified
operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility
classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
•
• ❑ ❑ ❑
❑ ❑ • ❑
• ❑ ❑ ❑
▪ ❑ ❑ ❑
• ❑ • ❑
Comment: The records reviewed during the inspection were organized and well maintained.
Discharge Monitoring Reports (eDMRs) were reviewed for the period October 2020
through September 2021.
No effluent limit violations were reported and all monitoring frequencies were correct.
Page# 3
Permit: NC0084387
Inspection Date: 10/28/2021
Owner - Facility: Lee S. Dukes WTP
Inspection Type: Compliance Evaluation
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ • ❑
❑ ❑ • ❑
Comment: On -site field analyses (pH, temperature, total residual chlorine) are performed under
Charlotte Water/Lee S. Duke WTP's field laboratory certification #5221. Charlotte
Water's Environmental Lab Services (Certification #192) performs all remaining
permit -required analyses with the exception of chronic toxicity (ETT Environmental).
The pH meter is calibrated every day; however, the effluent pH is measured
approximately six to seven hours following the calibration. The pH meter should be
re -checked with the 7.0 SU standard prior to analysis. In addition, the ORC and staff
must ensure that the calibration of the pH meter (4.0 SU, 7.0 SU and 10 SU standards)
and the serial #s for the pH and total residual chlorine meters are documented in
calibration log.
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional? ❑ El • El
Is sample collected below all treatment units? • ❑ El El
Is proper volume collected? • El El El
Is the tubing clean? ❑ El • ❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 El El • El
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type • El El El
representative)?
Comment: The subject permit requires effluent grab samples.
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • ❑ El El
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The NPDES facilities appeared to be properly operated and well maintained. The
treatment units and selected alarm conditions are connected to the on -site SCADA
system.
Equalization Basins
Is the basin aerated?
Yes No NA NE
❑ ❑ • ❑
Page# 4
Permit: NC0084387
Inspection Date: 10/28/2021
Owner - Facility: Lee S. Dukes WTP
Inspection Type: Compliance Evaluation
Equalization Basins
Is the basin free of bypass lines or structures to the natural environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Are audible and visual alarms operable?
# Is basin size/volume adequate?
Yes No NA NE
❑ • ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The equalization basin is equipped with mixers and an overflow bypass into an
unnamed tributary to McDowell Creek. No bypasses have occurred in many years.
The high water alarm system operated properly during the on -site test.
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth)
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ • ❑
❑ ❑ • ❑
Comment: The clarifier was operational and in service; however, no discharge over the weirs was
occurring during the inspection.
De -chlorination
Type of system ?
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de -chlorination substance stored away from chlorine containers?
Are the tablets the proper size and type?
Yes No NA NE
Liquid
❑ ❑ • ❑
❑ ❑ • ❑
Comment: Aqueous sodium bisulfite is used for dechlorination. Sodium bisulfite is added to both
the clarifier effluent and at the head of the dechlorination contact chamber. The
dechlorination system is only activated during discharge events.
Page# 5
Permit: NC0084387
Inspection Date: 10/28/2021
Owner - Facility: Lee S. Dukes WTP
Inspection Type: Compliance Evaluation
De -chlorination
Are tablet de -chlorinators operational?
Number of tubes in use?
Comment:
Chemical Feed
Is containment adequate?
Is storage adequate?
Are backup pumps available?
Is the site free of excessive leaking?
Comment:
Yes No NA NE
❑ ❑ • ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Lagoons Yes No NA NE
Type of lagoons?
# Number of lagoons in operation at time of visit? 1
Are lagoons operated in?
# Is a re -circulation line present? El El • ❑
Is lagoon free of excessive floating materials? • El El El
# Are baffles between ponds or effluent baffles adjustable? ❑ El • ❑
Are dike slopes clear of woody vegetation? El El • El
Are weeds controlled around the edge of the lagoon? • El ❑ ❑
Are dikes free of seepage? El El • El
Are dikes free of erosion? ❑ El • ❑
Are dikes free of burrowing animals? El El • El
# Has the sludge blanket in the lagoon (s) been measured periodically in multiple El El • ❑
locations?
# If excessive algae is present, has barley straw been used to help control the growth? El El ▪ El
Is the lagoon surface free of weeds? • ❑ ❑ ❑
Is the lagoon free of short circuiting? • El El El
Comment: The sludge lagoon consists of lined walls and a clay bottom. The supernate is
manually removed by operations staff. The supernate flow is combined with the
effluent from the dechlorination contact chamber prior to flow measurement.
Synagro is contracted to land apply the sludge under the authority of Permit No.
WQ0000057.
Flow Measurement - Effluent Yes No NA NE
Page# 6
Permit: NC0084387
Inspection Date: 10/28/2021
Owner - Facility: Lee S. Dukes WTP
Inspection Type: Compliance Evaluation
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ • ❑
Comment: The flow meter is calibrated annually and was last calibrated on 3/2/2021 by Charlotte
Water's I & E Division.
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment: The was facility was not discharging at the time of the inspection.
Yes No NA NE
Page# 7