Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0031050_Regional Office Historical File Pre 2018
Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality November 30, 2006 Mr. Chris Branch, Manager The Boulevard at Wendwood View, LLC 715 North Church Street - Suite 110 Charlotte, NC 28202 Subject: Permit No. WQ0031050 . The Boulevard at Wendwood View The Boulevard at Wendwood View, LLC Wastewater Collection System Extension C-MU TRACKING #600-06-586 Mecklenburg County, North Carolina Dear Mr. Branch, In accordance with your application received on November 1, 2006, we are forwarding herewith Permit No. WQ0031050, dated November 30, 2006, to The Boulevard at Wendwood View, LLC for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore - incorporated therein by reference. Please pay particular . attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design - Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.netnwaterquality.org Customer Service: 1-877-623-6748 An Equal OpportunitylAffirmative Action Employer— 50% Recycled/10% Post Consumer Paper o Carolina NNaturally Mr. 8ranch Page 2 November 30, 2006 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to The Boulevard at Wendwood View, LLC for the construction and operation of approximately 125 linear feet of 6-inch gravity sewer and the discharge of 6,080 gallons per day of collected domestic wastewater into the Charlotte Mecklenburg Utilities existing sewerage system, pursuant to the application received November 1, 2006, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Charlotte Mecklenburg Utilities WWTP (Sugar Creek NPDES No. NC0024937) prior to being discharged into the receiving stream. The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the terms .of the Operational Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statutes 143-215.6A to 143-215.6C for violation of or failure to act in accordance with the terms and conditions of this permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely G? a - for Alan W. Klimek, P.E. cc: . Mecklenburg County Land Use and Environmental Services Agency (LUESA) Steve Miller, CMU Philip Edward, Mecklenburg County Mooresville Regional Office, Surface Water Protection (WWTP Permit No. NC0024937) Jason Sesler, Stantec Consulting Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force, Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21_ .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system 'shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are,not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by ,North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable;. the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 30th day of November, 2006. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0031050 3 r. Fast Track Engineering Certification Permit No. WQ0031050 November 30, 2006 Chris Branch, Manager The Boulevard at Wendwood View, LLC 715 North Church Street Suite 110 Charlotte, NC 28202 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Boulevard at Wendwood View, a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND.THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Permit No. DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (di) and entered into this 5th day of October, 2006, by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and The Boulevard at Wendwood View, LLC, a corporationlgeneral partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. ATE OF NORTK / AROLINA COUNTY OF WITNESSETH: 1. The DEVELOPER is the owner of the certain lands lying in Mecklenburg County, upon which it erecting and will erect dwelling units and other improvements, said development to be known as The Boulevard at Wendwood View (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, the Wendwood View Condominium Owners Association, Inc._hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Quality has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3 The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. Uri T") 11. . \ ill fill rppir- 'The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance finds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL MANANT COMMISSION Alan W. Klimek, P.E., erect Division of Water Quality (Date) The Boulevard at Wendwood View, LLC Name of DEVELOPER By: (Signature) Ch4•34, 4,-3 $ ►e� Managin'g Mameber Print Name and Title October 5, 2006 (Date) t(\D & f. TINT !1^1 /Ill AST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIE Owner: la„ The Boulevard at Wendwood View LLC Full Legal Name (company, municipality, HOA, utility, etc, Christopher J. Branch, Manager Application Number: (to be completed by DWQ Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing o lc. The legal entity who will own this system is: ❑ Individual ❑ Federal ❑ Municipality ❑ State/County ❑ Private Partnership E Corporation ❑ Other (specify): © 1 d. 715 North Church Street. Suite 110 ▪ Mailing Address NC State Q 1 h. 704-334-8244 704-334-0047 Telephone Facsimile 2. Project (Facility information: 2a. The Boulevard at Wendwood View Brief Project Name (permit will refer to this name) Contact Person: le. Charlotte City 1 g. 28202 Zip Code kabner@theblvdco.com E-mail 2b. Mecklenburg County Where Project is Located 3a. Jason Sesler Project Manager Name and Affiliation of Someone Who Can Answer Questions About this Application 3b, 980-297-7684 3c. jsesler@stantec.com Phone Number E-mail . Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. Owner is ❑ Public (skip to Item B 2a. If private, applicant will be: Private (go to Item 2(a)) 2b. If sold, facilities owned by a (must ch O Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ® Selling units (lots, townhomes, etc. - go to Item B(2b)) C-MUD ❑ Public Utility (Instruction III) ® Homeowner Assoc./Developer (Instruction IV) Owner of Wastewater Treatment Facility (AJWTF) Treating Wastewater From This Project 4a. Sugar Creek Wastewater Treatment Plant 4b. NC0024937 Name of WWTF WWTF Permit No, 5a. C-MUD 5b. Owner of Downstream Sewer Ree Gravity ving Sewer Size ❑ Force Main The origin of this wastewater is (check all that apply): ❑ Residential Subdivision ❑ Car Wash ►i Apartments/Condominiums ❑ Institution ❑ Mobile Home Park 0 Hospital • School 0 Church Ej Restaurant 0 Nursing Home Office ❑ Other (specify): Volume of wastewater to be allocated for this particular project: 6,080 gallons per day *Do not include previously permitted allocations Permit Number of Downstream Sewer If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted in subsequent per ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected 100 % Domestic/Commercial % Industrial % Other (specify): hat connect to this line FTA 02/03 - Rev. 3 04/05 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 W Z 1- z 0 Z 0 2 0 u. 1- 2 tY 0. m i9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3). 32 Condo units x 190 gpd/unit 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) i Length (feet) 6 125 25 Gravity or Force Main (use the pull down menu) 1- Gravity (Sewer Service Connections) Con ENTER TOTAL LINE LENGTH IN MILES€ 0.10 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) N/A Location ID Power Reliability Option ' (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- plans for cross-reference) _ (MGD) _ GPM @ TDH _ portable generator w/telemetry; 4-wet well storage) y -.-_. ._. i - — — - 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? El Yes ❑ No ® N/A ® Yes ❑ No ❑ N/A Stormwater? ® Yes ❑ No ❑ N/A Sedimentation and Erosion Control Plan? 14. Does this project involve aerial lines or siphons? Check if yes: ❑ These_lines.W.il.I.be.considered,heh...priorityand,.must .be_Checked,o.nce_every..s.ix.morlths„ _ ,-,-,--„-„,•, ,,,-_ ,., 15. Does this project have gravity sewer lines designed at minimum slopes? ❑ Be aware that the Division will not accept installed lines more than 10% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. FTA 02/03 - Rev. 3 04/05 • AST -TRACK APPCATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 z 0 Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: ® A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on map for cross-reference) la. Name of Waterbody County Riv Basin terbody Stream Waterbody Index Classification Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: 1, Christopher Branch, attest that this application for The Boulevard at Wendwood View has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to `. $25, 000 per violation. Signing Official Signature Professional Engineer's Certification: Date I attest that this application for The Boulevard at Wendwood View has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations,, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a, Jason Sesler, PE. Professional Engineer Name 2b, Stantec Consulting Engineering Firm 2c. 2127 Ayrsley Town Blvd., Suite 300 Mailing Address 2d, Charlotte City 2g, 704-329-0900 Telephone 2e, NC State 2f. 28273 Zip 2h, 704-329-0905 2i, jseslerastantec.com Facsimile E-mail 0,1t11111110 CAR S 51� SEAL 2177 GENE; N, lllsstsi�r /b Seal, Signature & Date FTA 02/03 - Rev. 3 04/05 Permit Number WQ0031050 Central Files: APS SWP 11 /29/06 Permit Tracking Slip Program Category Non -discharge Status Project Type In review New Project Permit Type Fast Track Version Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Extensions - - Primary Reviewer dee.browder Permitted Flow 6080 Facility Facility Name The Boulevard at Wendwood View Location Address Owner Permit Classification Individual Permit Contact Affiliation Major/Minor Region Minor Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Owner Type The Boulevard At Wendwood View LLC Non -Government • Owner Affiliation Christopher Branch 715 N Church St Charlotte DateslEvents NC 28202 Orig Issue App Received Draft Initiated 11/01/06 Scheduled Issuance Public Notice Issue Effective Expiration Regulated Activities Requested/Received Events Subdivision Wastewater collection Outfall NULL Additional Information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin Transmit al Stantec Consulting Services Inc. 2127 Ayrsley Town Boulevard Ste, 300 Charlotte NC 28273 Tel: (704) 329-0900 Fax: (704) 329-0905 To: Company: Address: Phone: Date: File: Delivery:. e NCDENR - Mooresville 610 E. Center Ave, Suite 301 Mooresville NC 28115 704.663.1699 October 23, 2006 173200736 Courier ( From: Jason Sesler o For Your Information I For Your Approval © For Your Review O As Requested Reference: The Boulevard of VWendwood View Condo Britt, Iniuims Please find the attached application and required submittal documents and fees for approval for the private sewer system for the Boulevard at Wendwood View condominiums in Charlotte, NC. Please feel free to contact me if you should have questions or comments regarding this. S r� NTEC CONSULTING SERVICES INC, son Sesler, P.E. Project Manager Tel: (980) 297-7684 Fax: (704) 329-0905 jsesler@stantec.corn Attachment: 2 set of applications and supporting info (one original, one copy) c. project file, TBC 321a der7celwater•sew ^ peanri[ appNi baonsWn-©0736-sewer_uap icatrta'as-n errrdpr' eaze (CM CHARLOTTE.. C.HAR!..OrrE4VIEOKLEt.NIBURG olmuTIES .September28, 2006 Mr: Kenny .Abner The Boulevard at Wendwood Vievw,LLC 715. North Church Street Suite 110 Charlotte, NC 28202 S.U.BJECT: WATER AND SANITARY SEWER FLOW ACCEPTANCE THE BOULEVARD AT WENDWOOD VIEW TAX PARCEL #t 57-08'1-03 C-MU# 600-06-586 Dear Mr. Abner: in response to your request, a:fioWacceptance: study of the subject site has been completed and the following has been determined: Please see attached map. Upon completion and acceptance of'all necessary suer lines to serve thesubject site, Charlotte: - Mecklenburg Utilities agreesto accept the gravity sewage flow of 6,080 gallons per day`(32 condo units x 190 gpolunit) from this project for transmission to the Sugar Creek Wastewater Treatment Plant, NPDES permit number NC0024937, for treatment;This acceptance of flow is. based on the existing capacity of the designated publicly owned treatments works; which is contingent upon final acceptance and issuance of a discharge permit from the.appropriate local, 'State, or Federal Agency,. whichever might havecontrol. Upon completion and acceptance of'1l necessary water mains to serve the subject site, Charlotte - Mecklenburg Utilities agrees to furnish water to the subject project_ The water quality to the subject project is regulated by the State Dririkin; Water Act Amendments of 1986 and The Water Supply Management Plan, dated October 2005, (WMSP # 05-'1702 & PINS ID # 01.60010), on fife with the Public Water Supply Section of NCDENR. However, C-MU cannot guarantee a constant pressure or quality of flow. This a agreementis also contingent upon approval by the Division of Environment, and Natural Resources. Charlotte -Mecklenburg Utilities does not expect any of the above conditions to preclude water orsewer service to the subject site. However; the applicant should understand that due to the involvement of other agencies and continuing growth of the, water and sewer system, the ability to provide service -for: future projects cannot be guaranteed nor reserved.. Connection to the GMU system is accepted on.a first come, first served basis, If you have any. questions, you may contact me at (704) 391 �5129. Barbara Gross - Engineering Assistant 'New Services Section CHARLOTTE-MECKLENBURG UTILITIES Engineering Division • New Services Section www.cmutiiities:com 5100 Brookshire Boulevard Charlotte, NC 28216 Ph: 704/3,99-2221 Fax: 704/393-2219 Site C-M U# 600-06-586 3 Charlotte -Mecklenburg Utilites WWTP Service Areas with Basins a F , • I ¢v �°EaElard Creek WlM! rit4 lty W Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Careen Sullins, Director Division of Water Quality June 13, 2007 Chris Branch, Manager The Boulevard at Wendwood View, LLC 715 North Church Street Suite 110 Charlotte, North Carolina 28202 SUBJECT: The Boulevard at Wendwood View Permit No. WQ0031050 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on June 6, 2007. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from http://h2o.enr.state.nc.us/ndpu/ndpuap s.html#Sewer. If you have any questions concerning this document or the completion of Form PNOCF-S (if necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. Sincerely, jRobert Krebs Surface Water Protection Regional Supervisor Enclosure Cc: Jason Sesler, P.E. Stantac Consulting Services Philip Edwards Steve Miller, CMU Surface Water Protection Section Central Files (certification page only) NorthCarolina Naturally Pretreatment, Emergency Response and Collection Systems Unit Internet http://h2o.enr.nc.state.us/ndpu 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled/10% post -consumer paper aat Track Engineering Certification Permit No. WQ0031050 November 30, 2006 Chris Branch, Manager The Boulevard at Wendwood View, LLC 715 North Church Street Suite 110 Charlotte, NC 28202 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria, This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION 0 Partial final o r9:+r) SS�i~ g , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe t' periodically, 0 weekly, © full time) the construction of the Boulevard at Wendwood View, a Mecklenburg County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump. Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DgUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. stantec.com Transmittal Stantec Consulting Services Inc. 2127 Ayrsley Town Boulevard Ste. 300 Charlotte NC 28273 Tel: (704) 329-0900 Fax: (704) 329-0905 To: Company: Address: Phone: Date:. File: Delivery: Dee Browder NCDENR - Mooresville 610 E. Center Ave, Suite Mooresville NC 28115 (704) 663-1699 June 6, 2007 173200736 Task #201 Courier JUN O. From: Jason Se Q For Your Information 01 El For Your Approval O For Your Review O As Requested Reference: Wendwood View Engineer's Certification - WQ0031050 Dee, Please find the attached certification form with the as -built plans for the Wendwood View project in Charlotte, NC. Please feel free to call with questions or comments regarding this. STAIIiTEC CONSULTING SERVICES INC. on Sesier, P.E. roject Manager Tel: (980) 297-7684 Fax: (704) 329-0905 Jason.sesier@stantec.cam Attachment: 1 as -built plan and certification c. project file, TBC scu v V17 21active117320©736\designNearrespondencetwater and sewer permit apph atonsltm-00736Sewer CerUhcaSan-NCDENR-DeeBro der- 20070606.doc