HomeMy WebLinkAboutGW1-2021-03849_Well Construction - GW1_20210823 WELL CONSTRUCTION RECORD For Internal Use ONLY: This form can be used for single or mutiple wells 4. A•� R ZO. S 1.Well Contractor Information: FROM TO DESCRIPTION Chauncey Leggett ft ft Well Contractor Name ft ft 2269-A 5.0 ER I x for ul'Fc s wells O R(if applicable NC Well Contractor Certification Number FROM TO DIAMETER THICKNESS MATERIAL Lake Valley Well Co.,Inc 0 ft 84 ft 6.25 in- .188 Steel-galvanized Company Name ft M in. 6. R CAS G O UB G geothermal c ose oop 2.Well Construction Permit!#: E21-000296 FROM TO DIAMETER TIIICKNESJ MATERIAL List all applicable well construction pertmits(ie County,State, Variance,etc. ft ft in. 3.Well Use: ft ft in, 7.SGR E FROM TO DIAMETER TIUCKNESS SLOTS MATERIAL Residential ft ft in. ft ft FROM TO MATERIAL EMPLACEMENT METHOD&AMOUNT ft 26 ft ft ft ft ft 9.S_A /GRAB C if a'pp ica le) FROM TO MATERIAL. EMPLACEMENT METHOD&AMOUNT ft ft ft ft 4. Date Well(s)Completed: 8/3/2021 Well ID# ft ft 5a. Well Location: 0. G OG(attac additional s ee if necess ry. MW List all applicable well construction pertmits(fe County,State,Variance,etc. FROM TO DESCRIPTION(color,hardness,soil/rock type,grain size,etc) Clayton Homes of Greenville 0 ft 1 ft Brown Topsoil Facility/Owner Name Facility ID(if applicable) 1 ft 18 ft Red Clay 7516 Strickland Road Bailey Lot 18 ft 50 ft Yellow Clayey Sand Physical Address,City,and Zip 50 ft 75 ft Brown Shale Nash 335567 75 ft 203 ft Gray Slate ; County Parcel Identification No.(PIN) ft ft �1\� 5b. Latitude and Longitude degrees/minutes/seconds or decimal degrees: ft ft (If well field,one lat/long is sufficient.) 21. 35.838957 N -78.130962 W Water zone 165 and 200 feet 6. Is(are)the well(s): Permanent 22. Certification: 00 7. Is this a repair to an existing well: No tJYr 8/3/2021 If this is a repair,fill out known well construction information and explain the nature of the Signature of Certified Well Contractor Date repair under#21 remarks section or on the back of this form. By signing this form,I hereby certify that the well(s)was(were)constructed in accordance with I SA NCAC 02C.0100 or I SA NCAC 02C.0200 Well Construction Standards and that a 8. Number of wells constructed: 1 copy of this record has been provided to the well owner. For multiple injection or non-water wells ONLY with the same construction,you can 23. Site diagram or additional well details: submit one form. You may use the back of this page to provide additional well site details or well construction details. You may also attach additional pages if necessary. 9.Total well depth below land surface: 203 (ft.) For multiple wells list all depths if different(example-3@ 200'and 2 @ 1009 SUMITTAL INSTRUCTIONS 24a.For All Wells: Submit this form within 30 days of completion of well 10.Static water level below top of casing: 22 (ft) construction to the following: If water level is above casing,use"+" Division of Water Quality,Information Procession Unit, 11. Borehole diameter: 6 (in.) 1617 Mail Service Center,Raleigh,NC 27699-1617 12. Well construction method: Rotary air 24b.For Injection Wells: In addtion to sending the form to the address in 24a (i.e.auger,rotary,cable,direct push,etc.) above,also submit a copy of this form within 30 days of completion of well construction to the following: FOR WATER SUPPLY WELLS ONLY: Division of Water Quality,'Undergroun Injection Control Program, 1636 Mail Service'Center,Raleigh,NC 27699-1636 13a. Yield(gpm): 7 Method of test: Air 24c.For Water Supply In°ection Wells: ' In addtion to sending the form to the address(es)above,also submitlone copy of this form within 30 days of 13b. Disinfection type: HTH Amount: 16 CZ completion of well construction to the county health department of the county where constructed. Form GW-1 North Carolina Department of Environment and Natural Resources - Division of Water Quality Revised 2/22/16