Subject: Compliance Evaluation Inspection
Weston Solutions Cotton Mill Square Site Groundwater Remediation Program
Permit No. WQ0036621
Forsyth County
Dear Mr. Kane:
On September 23, 2021 staff of the North Carolina Division of Water Resources Winston-Salem
Regional Office (DWR) performed an announced routine compliance inspection of the Weston
Solutions Cotton Mill Square groundwater remediation program. This inspection was conducted
by DWR staff member Jim Gonsiewski. Mr. Greg Flasinski of Weston Solutions met with Mr.
Gonsiewski for the inspection. The inspection reflects compliance with the permit.
If you have any questions regarding this letter, please contact Jim Gonsiewski or me at (336)
776-9800.
Sincerely,
C1 DoouSign.d by: q
L.�M 1. SMxtr
746B49E225C94EA,,.
Lon T. Snider
Regional Supervisor
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ — WSRO
cc: WSRO Electronic Files
Laserfiche Files
x'DE
o.p.( 11 t*a.un.nr a.m�
North Carolina Department of Environmental Quality I Division of Water Resources
Winston-Salem Regional Office 1450 West Hanes Mill Road, Suite 300 I Winston-Salem, North Carolina 27105
336.776.9800
z
'"4
-
_ z
I-
FF l`x• I 1 --
1
- I I I
I r
1' I I_ al I .11 I
1
11
=
A -t
=i.•I •
IN. I: z I: t - ;11
if 1
I :AtZ
_
•••
z =
Compliance Inspection Report
Permit: WQ0036621 Effective: 02/26/19 Expiration: 01/31/24 Owner : Weston Solutions Inc
SOC: Effective: Expiration: Facility: Cotton Mill Square Site (CMS)
County: Guilford 801 Merritt Dr Se Of Spring Garden St And Mer
Region: Winston-Salem
Contact Person: Ed Mackey
Directions to Facility:
Greensboro NC 27407
Title: On -site Rep Phone: 919-816-6237
System Classifications: PCNC,
Primary ORC: Certification: Phone:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
WQ0029385 Weston Solutions Inc - Cotton Mill Square
Inspection Date: 09/23/2021 Entry Time 10:10AM
Exit Time: 11:15AM
Primary Inspector: Jim J Gonsiewski Phone: 336-776-9704
Secondary Inspector(s):
Reason for Inspection: Routine
Permit Inspection Type: Groundwater Remediation
Facility Status: Compliant 0 Not Compliant
Question Areas:
IN Wells
(See attachment summary)
Inspection Type: Compliance Evaluation
In Treatment Units Sampling
Page 1 of 3
Permit: WQ0036621 Owner - Facility: Weston Solutions Inc
Inspection Date: 09/23/2021 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Inspection Summary:
Jim Gonsiewski of the WSRO on site at 10:10 AM 9/23/2021. Met with Greg Flasinski of Weston Solutions. Toured the
site. First visited the old remediation area. Previously a pump and treat system was located at the site. According to David
Kane of Weston Solutions, in 2009 the system was shut down due to extensive damage that occured during construction of
the Block 43 Apartments/Cottages student housing. 16 wells, a remediation system building, and associated underground
piping and valves were destroyed during the construction grading and work. Additionally, another 6 wells were damaged.
A remediation injection system (injection of diluted Newman Zone emulsified vegegtable oil in four injection wells across the
site) was permitted in February 2019. This system was abandoned in September 2019.
Observed the location of the new remediation system along Blunt street in the paved area along the southwestern boundary
of the site. Area appeared to have good access and room to install the new system.
Page 2 of 3
Permit: WQ0036621 Owner - Facility: Weston Solutions Inc
Inspection Date: 09/23/2021 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Page 3 of 3
View looking southwest of the proposed area of CAT 100 injection points. Former
Extraction Well EW-504 is visible to the right of the vehicle hood. The pilot test area was
located to the right and behind of EW-504. The injection points will be located along the
right side of the road.
View looking south toward the area of the former remediation building that was demolished in
2009 during the construction of the Block 43 Apartments/Cottages. The building was located
directly in front of the maintenance shed visible near the center of the photograph.
View of the remaining remediation shed on the southeast side of the property.