Loading...
HomeMy WebLinkAboutSW6210906_Supplement-EZ Form_20211014 SUPPLEMENT-EZ COVER PAGE FORMSLOADED PROJECT INFORMATION Project Name Brooke Valley Subdivision 1 2Project Area (ac)50.2 3Coastal Wetland Area (ac) 4Surface Water Area (ac) 5Is this project High or Low Density?Low Does this project use an off-site SCM?No 6 COMPLIANCE WITH 02H .1003(4) 7Width of vegetated setbacks provided (feet)30' 8Will the vegetated setback remain vegetated?Yes 9If BUA is proposed in the setback, does it meet NCAC 02H.1003(4)(c-d)? Is streambank stabilization proposed on this project?No 10 NUMBER AND TYPE OF SCMs: 11Infiltration System 12Bioretention Cell 13Wet Pond 14Stormwater Wetland 15Permeable Pavement 16Sand Filter 17Rainwater Harvesting (RWH) 18Green Roof 19Level Spreader-Filter Strip (LS-FS) 20Disconnected Impervious Surface (DIS) 21Treatment Swale 22Dry Pond 23StormFilter 24Silva Cell 25Bayfilter Filterra 26 FORMSLOADED DESIGNER CERTIFICATION 27Name and Title:Scott Brown, PE - Vice President 28Organization:4D Site Solutions, Inc 29Street address:409 Chicago Drive, Suite 112 30City, State, Zip:Fayetteville, NC 28306 31Phone number(s):910-426-6777 Email:sbrown@4dsitesolutions.com 32 Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer ______________________________________________ Signature of Designer ______________________________________________ Date Seal DRAINAGE AREAS 1Is this a high density project?No ge areas/SCMs0 2 If so, number of draina 3Does this project have low density areas?Yes 4 If so, number of low density drainage areas1 Is all/part of this project subject to previous rule 5versions?No FORMSLOADED Entire SiteLD 1 DRAINAGE AREA INFORMATION 4Type of SCM ge area (sq ft)21865702186570 5Total draina 6Onsite drainage area (sq ft)21865702186570 7Offsite drainage area (sq ft)00 ject(sq ft)162433 sf162433 sf 8Total BUA in pro New BUA on subdivided lots (subject to 9permitting)(sq ft)108000 sf108000 sf New BUA not on subdivided lots (subject to 10permitting)(sf)54433 sf54433 sf 11Offsite BUA (sq ft) 12Breakdown of new BUA not on subdivided lots: - Parking(sq ft) - Sidewalk (sq ft) - Roof (sq ft) - Roadway(sq ft) - Future (sq ft) - Other, please specify in the comment box below(sq ft) New infiltrating permeable pavement on 13subdivided lots (sq ft) New infiltrating permeable pavement not on 14subdivided lots (sq ft) Existing BUA that will remain (not subject to 15permitting)(sq ft) 16Existing BUA that is already permitted (sq ft) 17Existing BUA that will be removed (sq ft) 18Percent BUA7%7% 19Design storm (inches)1.0 in1.0 in 20Design volume of SCM (cu ft) Calculation method for design volume 21 ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22drainage area(s): LOW DENSITY 59{LDbw9v…Lw9a9b{Chw\[h‘59b{L—twhW9/{CwhaЉЋI͵ЊЉЉЌ Yes 1Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3Has the use of piping been minimized per .1003(2)(c)? 3 sf 4 Side slopes of the vegetated conveyances (H:V) 7.69 5Maximum velocity in the vegetated conveyances during the 10-year storm? Yes 6 Are curb outlet swales proposed? 9% 7Maximum longitudinal slope of curb outlet swale(s) (%) 2 ft 8 Bottom width of curb outlet swale(s) (feet) 3:1 9Maximum side slope of curb outlet swale(s) (H:V) 105 ft 10 Minimum length of curb outlet swale(s) (feet) No 11Are treatment swales used instead of curb outlet swales? Yes 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13Have stormwater outlets been designed to prevent downslope erosion? No Are variations to rule .1003 proposed? 14 ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: DrainagePervious VV SwaleBUAQSlope Flow depth ğƌƌƚǞğĭƷǒğƌ AreaareaC #(ac)(cfs)(%) ΛŅƦƭΜΛŅƦƭΜ(ft) (ac)(ac) 2.420.561.860.457.934.303.255.000.63 1 1.340.311.030.454.371.701.155.000.85 2 1.340.311.030.454.378.203.605.000.39 3 4.240.510.320.704.245.502.565.000.48 4 1.730.800.930.607.568.607.695.000.33 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30