Loading...
HomeMy WebLinkAboutSW6210906_Plansheet - SCM Detail_20211014 (2)5' MIN. EXIST. ROAD 20' AVG. POLY. WATER SERVICE LINE BRASS ADAPTER FOR COMPRESSION CONECTION CORPORATION STOP 11 � HOKE COUNTY REGIONAL WATER SYSTEM DETAILS HOKE COUNTY, NORTH CAROLINA CAL ■ METER BOX ON P ANGLE VALVE DOUBLE CHECK VALVE COMPRESSION FITTING PVC CASING CLASS 200) �a •► 1�. INLETS WILL HAVE A BRASS ADAPTER AS REQUIRED FOR A COMPRESSION FITTING TO "IPS" WATER SERVICE PIPE. 2. YOKE WILL HAVE CHECK VALVE THAT SHALL HAVE SPRING ASSISTED SEATING, AND THE SEAT SHALL BE OF BUNA-N- RUBBER. 3.OUTLEI' SHALL BE FORD DOUBLE PURPOSE COUPLING OR APPROVED EQUAL. 4. METER YOKES SHALL BE SUPPORTED AS CALLED FOR IN SPECIAL PROVISIONS. TYPICAL HOUSE SERVICE DETAIL (LONG) 5.75" I-� �-I 5.75" 17.25" SOLID COVET 00 20.125" SECTION A -A HOKE COUNTY REGIONAL WATER SYSTEM DETAILS HOKE COUNTY, NORTH CAROLINA METER BOX (GONG., C/I, OR PLASTIC COPPER SETTER TO BE p FORD (VHH172-7W-SN) OR APPROVED EQUAL METER YOKE SECTION B-B WATER METER BOX DETAIL N.T.S. MIN. AVG. WGT. FRAME 50 LBS. COVER 20 LBS. WATER METER BOX DETAIL DOUBLE ----C METER BY ___- CHECK VALVE 1T OTHERS METER BOX OO I� PLASTIC R COPPER SETTER OUTLET TO BE FORD (VHH 172-7W-SN) OR APPROVED EQUAL METER YOKE R/W ANGLE VALVE CORPORATION STOP POLY. WATER SERVICE LINE COMPRESSION SADDLE FITTING BRASS ADAPTER FOR COMPRESSION CONECTION TYPICAL HOUSE SERVICE DETAIL (SHORT) N.T.S. NOTES: 1. INLETS WILL HAVE A BRASS ADAPTER AS REQUIRED FOR A COMPRESSION FITTING TO "IPS" WATER SERVICE PIPE. 2. YOKE WILL HAVE CHECK VALVE THAT SHALL HAVE SPRING ASSISTED SEATING, AND THE SEAT SHALL BE OF BUNA-N- RUBBER. 3. OUTLET SHALL BE FORD DOUBLE PURPOSE COUPLING OR APPROVED EQUAL. 4. METER YOKES SHALL BE SUPPORTED AS CALLED FOR IN SPECIAL PROVISIONS. HOKE COUNTY REGIONAL WATER SYSTEM DETAILS HOKE COUNTY, NORTH CAROLINA TYPICAL HOUSE SERVICE DETAIL (SHORT) SEAL EACH END OF CASING - WITH SOLID CONCRETE BRICK AND 1:3 MORTAR 12" MINIMUM LENGTH. CARBON STEEL CARRIER PIPE BRACE SHALL BE PLACED 3' PRIOR TO AND 3' AFTER EACH JOINT OF DUCTILE IRON CARRIER PIPE. (SEE DETAIL BORE UNDER ROADWAYS/RAILROADS SHT 2 OF 2 FOR SPECIFIC REQUIREMENTS) STEEL CASING SIZED AS INDI, ON THE BORE SIZING CHART. CARRIER PIPE SHALL BE DUCTILE IRON WITH PROPER �- • EXTERIOR AND INTERIOR COATINGS EACH SECTION OF COMPLETELY FILL ENCASEMENT PIPE SHALL VOID OUTSIDE OF BE BE BUTT -WELDED TO THE NOTE: CASING W/ 1:3 GROUT• ADJACENT CASING PIPE 1. SEE DWG M.6 SHEET 2 OF 2 FOR ADDITIONAL INFORMATION. HALF SECTION ISOMETRIC OF BORE BORE UNDER ROADWAYS/RAILROADS N.T.S SHEET NO. I DWG. NO. M.6 1 OF 2 DATE JULY 01, 2016 BORE SIZING CHART CARRIER PIPE SIZE MIN. CASING SIZE ROADWAYS MIN. WALL THICKNESS RAILROADS MIN. WALL THICKNESS 4" 10" 0.188" 0.188" 6" 12" 0.25" 0.281" 8" 16" 0.25" 0.281" 12" 24" 0.25" 0.375" 16" 30" 0.312" 0.469" 18" 30" 0.312" 0.469" 24" 36" 0.375" 0.532" 301, 1 42" 0.500" 1 0.625" 36" 48" 0.500" 0.688" *CONTRACTOR MAY SUBSTITUTE A LARGER SIZE CASING PIPE HAVING THE MIN. WALL THICKNESS SHOWN FOR SEWER MAINS. ALL ADDITIONAL COSTS SHALL BE INCLUDED IN THE UNIT PRICE BID FOR BORING AND JACKING. FASTEN BRACE TO PIPE W/ HEAVY DUTY STUDS, NUTS AND WASHERS. RUNNERS SHALL BE MIN. 2" SOLID CONCRETE BRICK AND 1:3 MORTAR., COMPLETELY FILL VOIDS BETWEEN BRICK WITH MORTAR. CLOSE EACH END OF CASING. COMPLETELY FILLS VOID OUTSIDE OF CASING W/GROUT I SEE NOTE 4 RJDI CARRIER PIPE STEEL CASING BAND -12 GA. MIN. RISER -8 GA. MIN CARBON STEEL SECTION "A -A" CARBON STEEL CARRIER PIPE BRACE BORE UNDER ROADWAYS/RAILROADS N.T.S DWG. NO. M.6 I SHEET NO. 2 OF 2 DATE JULY 01, 2016 2. CARRIER PIPE FOR PRESSURE APPLICATIONS (WATER MAINS & FORCE MAINS) SHALL HAVE FACTORY RESTRAINED JOINTS. CARRIER PIPE FOR GRAVITY SEWER SHALL HAVE RESTRAINED JOINTS AND MAY USE RESTRAINING GASKETS SUCH AS FIELD LOK, SURE STOP 350 OR OTHER APPROVED GASKETS. 3. CARRIER PIPE SHALL BE CLASS 350 OR 250 FOR WATER, AND SHALL BE CLASS 50 FOR SEWER. DATE I REVISION 2016-M6 BORE-ROAD-RAIL.dwg NOTES: 1. INSTALLATION SHALL BE DRY BORE AND JACKING OF SMOOTH WALL STEEL PIPE. JETTING OR WET BORING WITH WATER SHALL NOT BE ALLOWED. 2. SEE BORE SIZING CHART FOR CARRIER PIPE SIZE AND STEEL CASING SIZE, MIN. DIA. AND WALL THICKNESS. 3. CASING PIPE SHALL BE IN ACCORDANCE WITH ASTM A-53, GRADE B WITH A MINIMUM YIELD STRENGTH OF 35,000 PSI 4. EACH END OF ENCASEMENT TO BE PLUGGED WITH BRICK. ALL VOIDS OUTSIDE THE CASING PIPE SHALL BE COMPLETELY FILLED WITH 1:3 PORTLAND CEMENT GROUT AT SUFFICIENT PRESSURE TO INSURE NO SETTLEMENT OF ROADWAY/ RAILROAD. METHOD OF GROUTING SHALL BE AS APPROVED BY THE PERMITTING AGENCY. 5. IT IS RECOMMENDED THAT THE BORE BE ACCOMPLISHED BEFORE PIPE CONSTRUCTION BEGINS. 6. THE BORING SHALL BE PERFORMED FROM "UPSTREAM" TO "DOWNSTREAM" DIRECTION MAINTAINING THE CRITICAL DOWNSTREAM INVERT ELEVATION. SHOULD THE BORE NOT BE ON GRADE, A REVISED PLAN SHALL BE SUBMITTED TO HCPW FOR APPROVAL. 7. THE BORING OPERATION SHALL BE CONDUCTED IN A MANNER THAT THE FLOW OF TRAFFIC IS NOT IMPEDED OR IN SUCH A MANNER SO AS NOT TO CREATE A HAZARD. 8. IF AN OBSTRUCTION IS ENCOUNTERED DURING THE BORING OPERATION, THE AUGER SHALL BE WITHDRAWN THE EXCESS CASING PIPE CUT-OFF, CAPPED AND THE INTERIOR AND EXTERIOR VOIDS SHALL BE COMPLETELY FILLED W/1:3 PORTLAND CEMENT GROUT UNDER PRESSURE. NO SEPARATE PAYMENT FOR UNSUCCESSFUL BORES. 9. CONTRACTOR SHALL FIELD ADJUST AND INSTALL PROPER PIPE BRACES TO ACCOMPLISH GRADE AND INVERTS AS SHOWN ON THE DRAWINGS. 10. A MANUAL CONTROL STEERING HEAD OR OTHER GUIDANCE SYSTEM IS RECOMMENDED FOR BORES 30" DIAM. AND/OR LARGER AND FOR BORES EXCEEDING 100' IN LENGTH OR AS SPECIFIED. 11. SUBCONTRACTORS SHALL ADHERE TO ALL PERMIT REQUIREMENTS AND SHALL PROVIDE APPROVED INSURANCE CERTIFICATES AS REQUIRED. 12. CONTRACTOR SHALL EXECUTE AND PERFORM ALL REQUIREMENTS AND CONDITIONS STIPULATED BY THE PERMITTING AGENCY. 13. SEE DWG M.6 SHEET 1 OF 2 FOR ADDITIONAL INFORMATION. 14. CARRIER PIPE FOR PRESSURE APPLICATIONS (WATER MAINS & FORCE MAINS) SHALL HAVE FACTORY RESTRAINED JOINTS. CARRIER PIPE FOR GRAVITY SEWER SHALL HAVE RESTRAINED JOINTS AND MAY USE RESTRAINING GASKETS SUCH AS FIELD LOK, SURE STOP 350 OR OTHER APPROVED GASKETS. DATE REVISION 3" WIDE DETECTOR TAPE - 18" BURY I1P111 Hlflll-IIIIIIIIIIIIII III #10 SOLID �f� Fff) i« IIII w COPPER WIRE UII II`=I IIII II Y SPIRAL WRAPPED II=N� IE� �I m o AROUND PVC PIPE III III (IIII = -=IIII NOT REQUIRED II IIII P z z_ FOR DIP IIII IIII-I��IiI Iii � 111111�- IIIIII �IIIIIII IIIHII 1fIIlII. M III �1� -ILK I�I*II� _�4I_� LL- CL z$I� III fib:- © I$I�I IIII- 1 III z PIPE Z 0 UNDISTURBED SOIL WIDTH w AS REQUIRED m BELL O.D.+12" MIN. BELL O.D.+24" MAX. WATER MAIN TRENCH DETAILS N.T.S. NOTES: 1. LAYING CONDITIONS AS PER AWWA C600 AND C605 STANDARDS. 2. BEDDING MATERIAL SHALL BE 4" MINIMUM THICKNESS, LOOSE SOIL (DEFINED AS NATIVE SOIL EXCAVATED FROM THE TRENCH), FREE FROM ROCKS AND SHALL PROVIDE UNIFORM SUPPORT FOR THE FULL LENGTH OF PIPE. COMPACT TO 95% MAXIMUM DENSITY. 3. INITIAL BACKFILL SHALL BE LIGHTLY CONSOLIDATED IN MAXIMUM 6" LOOSE LIFTS, COMPACTED TO 95% OF MAXIMUM DENSITY. 4. UNDER AREAS TO BE SEEDED OR SODDED, COMPACT SUCCEEDING LAYERS OF FINAL BACKFILL IN 12" LOOSE LIFTS TO 85% MAXIMUM DENSITY. 5. UNDER STRUCTURES, PAVEMENTS AND ROAD SHOULDERS, COMPACT SUCCEEDING LAYERS OF FINAL BACKFILL IN 6" LOOSE LIFTS TO 95% MAXIMUM DENSITY EXCEPT COMPACT TOP 12" OF SUBGRADE TO 98 % MAXIMUM DENSITY. 6. PROVIDE #10 SOLID COPPER WIRE IN SUFFICIENT LENGTH TO BE SPIRAL WRAPPED AROUND EACH SEPARATE RUN OF ALL BURIED PVC PIPING. AT VALVE BOXES, BRING WIRE TO WITHIN 6 IN. OF TOP OF BOX AND INSERT INTO BOX THROUGH DRILLED HOLE. NOT REQUIRED FOR DUCTILE IRON PIPE. 7 INSTALL 3" WIDE DETECTOR TAPE AT 18" DEPTH. TAPE SHALL HAVE MIDDLE FOIL LAYER. HOKE COUNTY REGIONAL WATER SYSTEM DETAILS WATER MAIN TRENCH DETAILS HOKE COUNTY, NORTH CAROLINA 11 IIII solutions D s im t e e�ivil engineering I land surveying 409 Chicago Drive, Suite 112, Fayetteville, NC 28306 office 1 910-426-6777 fax 1 910-426-5777 license number I C-2354 wwwAD site solutions.com .CARpi SS'• SEA 0274 - v. c �O 1 1111���`````` REVISIONS PROJECT NAME BROOKE VALLEY SUBDIVISION WATER DETAILS CLIENT STOUT LAND DEVELOPMENT, LLC 1786 Metromedical Drive Fayetteville, North Carolina 28304 Phone: (910) 779-0019 PROJECT INFORMATION DESIGNED BY: SEAN DRAWN BY: BRETT CHECKED BY: SCOTT PROJECT NUMBER: 1781 DRAWING SCALE NOT TO SCALE DATE RELEASED SEPTEMBER 8, 2021 SHEET NUMBER C-604 2016-M6 BORE-ROAD-RAIL.dwg