HomeMy WebLinkAboutNC0024571_Pretreatment Inspection_20021117ATA NCDENR North Carolina Department of Environment and Natural Resources Michael F. Easley, Governor November 7, 2002 Ms. Karen Lewis Laboratory Supervisor City of Lumberton P.O. Box 1388 Lumberton, NC 28359 SUBJECT: Pretreatment Compliance Inspection (PCI) Lumberton WWTP NPDES Permit No. NC0024571 Robeson County Dear Ms. Lewis: William G. Ross, Jr., Secretary Alan Klimek, Director Division of Water Quality Enclosed please find a copy of the Pretreatment Compliance Inspection report for the inspection conducted on October 22, 2002 at the City of Lumberton Wastewater Treatment Plant (WWTP) in which I met with Karen Lewis (Laboratory Supervisor), Steve West (Laboratory Pretreatment Officer), Chris Conner (Pretreatment Coordinator). The report indicates that the Lumberton WWTP meets the pretreatment requirements as outlined in 15A NCAC 2H .0900 for Local Pretreatment Programs. A file review was performed on the records of Pepsi Bottling Ventures, Elkay 1, and Elkay 2. No Industrial Inspection was conducted during this Pretreatment Compliance Inspection. The report is self-explanatory and contains observations and recommendations. Where recommendations are cited, we ask that you provide a written description of how each has or will be addressed. We ask that your response be forwarded to the Fayetteville Regional Office by December 20, 2002. We appreciate your cooperation and that of your staff. You are commended for your continued success in maintaining your Pretreatment Program. If you or your staff have any questions or require clarification, please do not hesitate to contact me at (910).486-1541. Sincerely, Dale Lope Environmental Specia ist /dl Enclosures: Pretreatment Compliance Inspection Report cc: Deborah Gore, DWQ Pretreatment Unit Fayetteville Regional Office 225 Green Street — Suite 714, Fayetteville, North Carolina 28301-5043 Phone: 910-486-1541/FAX: 910-486-07071 Internet: www.ennstate.nc.us/ENR An Equal Opportunity 1 Affirmative Action Employer — 50% Recycled 110% Post Consumer Paper NORTH CAROLINA DIVISION OF WATER QUALITY PRETREATMENT COMPLIANCE INSPECTION (PCI) REPORT FAYETTEVILLE REGIONAL OFFICE BACKGROUND INFORMATION 1. Control Authority (POTW) Name: Lumberton 2. Control Authority Representative: Karen Lewis/Steve West/Chris Conner 3. Title(s): Laboratory Supervisor / Laboratory PT Officer/ Pretreatment Coordinator 4. Last Inspection Date: 04/10/02 Inspection Type (Circle One): PCI Audit 5. Has Program Completed All Requirements from the Previous Inspection or Program Info Sheet(s)? 6. Is POTW under an Order That Includes Pretreatment Conditions? Order Type and Number: N/A Are Milestone Dates Being Met? Yes / No PCS CODING Trans.Code Program NPDES Number MM/DD/YY JNI 1 NI CIO 10 12 14 15 17 11 J 10 /22 /02 (DTIA) 7. Current Number of Significant Industrial Users (SIUs)? 8. Current Number of Categorical Industrial Users (CIUs)? Inspec.Type J� (TYPI) Culp, Inc. IUP #008 was dropped as SIU 9. Number of SIUs Not Inspected by POTW in the Last Calendar Year? 10. Number of SIUs Not Sampled by POTW in the Last Calendar Year? 11. Enter the Higher Number of 9 or 10. 12. Number of SIUs With No IUP or With an Expired IUP? 13. Number of SIUs In SNC for Either Reporting or Limits Violations During Either of the Last 2 Semi -Annual Periods (Total Number of SIUs in SNC). 14. Number of SIUs in SNC for Reporting During Either of the Last 2 Semi -Annual Periods. 15. Number of SIUs in SNC for Limits Violations During Either of the Last 2 Semi -Annual Periods? 16. Number of SIUs in SNC for Both Reporting and Limits Violations During Either of the Last 2 Semi -Annual Periods? POTW INTERVIEW 17. Since the Last PCI, has the POTW had any NPDES Limits Violations? If Yes, How Are These Problems Being Addressed? 18. Since the Last PCI, has the POTW had any Problems Related to an Industrial Discharge (Interference, Pass -Through, Blockage, Citizens' Complaints, Increased Sludge Production, Etc.)? If Yes, How Are These Problems Being Addressed? Inspector LSD (INSP) YES Yes / / No No Fac.Type i1J (FACC) 9 1 0 0 0 0 0 0 0 0 SIUS CIUS NOIN NOCM PSNC MSNC SNPS YES INO YES NO . 19. Which Industries have been in SNC during either of the Last 2 Semi - Annual Periods? Have any Industries in SNC (During Either of the Last 2 Semi -Annual Periods) not been Published for Public Notice? (May refer to PAR if Excessive SIUs in SNC) SNC for Limits: 0 SNC for Reporting: 0 Not Published: 0 20. Which Industries are on Compliance Schedules or Orders? For all SIUs on an Order, Has a Signed copy of the Order been sent to the Division? 21. Are any Permits or Civil Penalties Currently Under Adjudication? If Yes, Which Ones? none YES NO PRETREATMENT PROGRAM ELEMENTS REVIEW - Please review POTW files and complete the following: Program Element Date of Last Approval . Date Next Due, If Applicable Headwork Analysis (HWA) 05/19/00 Industrial Waste Survey (IWS) 03/26/02 Sewer Use Ordinance (SUO) 09/17/96 Enforcement Response Plan (ERP) 05/31/95 Long Term Monitoring Plan (LTMP • 11/22/00 22. Is the LTMP Monitoring Being Conducted at Appropriate Locations and Frequencies? 23. Should any Pollutants of Concern be Eliminated From or Added to the LTMP? If Yes, which ones? Eliminated: Added: 24. Are Correct Detection Levels being used for all LTMP Monitoring? Yes / No Yes / Yes No / No 25. Is the LTMP Data Maintained in a Table or Equivalent? . Ye / No Is the Table Adequate? Y s No INDUSTRIAL USER PERMIT (UP) FILE REVIEW 26. User Name., Pepsi Bottling Ventures Elkay 1 Elkay 2 27. IUP Number 015 001 013 28. Does File Contain Current Permit? Yes Yes Yes 12/31/00 12/31/00 12/31/00 12/31/04 12/31/04 12/31/04 29. Permit Expiration Date? N/A N/A N/A 30. Categorical Standard Applied (I.E. 40 CFR 413, Etc.) or N/A Yes Yes Yes 31. Does the File Contain Permit Application Completed Within One Year 10/23/00 12/04/98 08/10/99 Prior to Permit Issue Date? 32. Does the File Contain an Inspection Completed Within Last Calendar Year? Yes Yes Yes 10/16/01 12/14/01 12/14/01 33. a. Does File Contain A Slug Control Plan? b. If No, is One Needed? (See Inspection Form from POTW) Yes 10/18/02 Yes 11/29/93 Yes 11/29/93 34. For 40 CFR 413 And 433 TTO Certifiers, Does The File Contain A Toxic Organic Management Plan (TOMP)? N/A N/A N/A 35. a. Does the File Contain Original Permit Review Letter from the. Division? b. All Issues Resolved? a. Yes b. Yes a. Yes b. Yes a. Yes b. Yes 36. During the Most Recent Semi -Annual Period, Did the POTW Complete its Sampling as Required by IUP? Yes Yes Yes 37. Does File Contain POTW Sampling Chain -Of -Custody's? (In Hydro Management's office, but not at the PCI.) Yes Yes Yes 38. During the Most Recent Semi -Annual Period, Did the SIU Complete its Sampling as Required By IUP? Yes Yes Yes 39. Does Sampling Indicate Flow or Production? Yes Yes Yes 40. During the Most Recent Semi -Annual Period, Did the POTW Identify All Non -Compliance from Both POTW and SIU Sampling? Yes Yes Yes 41. a. Was the POTW Notified by SIU (Within 24 Hours) of All Self Monitoring Violations? Copper violation of 0.061 lbs/day on 11/18/99. b. Did Industry Resample Within 30 Days? a. Yes b. Yes a. Yes (pH) b. Yes a.Yes (pH) a. Yes 42. Was the SIU Promptly Notified of any Violations (Per ERP)? Yes Yes Yes 43. During the Most Recent Semi -Annual Period, Was the SIU in SNC? No No No 44. During the Most Recent Semi -Annual Period, Was Enforcement Taken as Specified in the POTWs ERP? N/A Yes (NOV) Yes (NOV) 45. Does the File Contain Penalty Assessment Notices? N/A N/A N/A 46. Does the File Contain Proof of Penalty Collection? N/A N/A N/A 0 47. a. Does the File Contain any Current Enforcement orders? b. Is SIU in Compliance with Order? N/A N/A N/A 48. Did the POTW Representative Have Difficulty in Obtaining any of this Requested Information for You? No No • No FILE REVIEW COMMENTS PCI SUMMARY AND COMMENTS Lumberton WWTP Pretreatment Permit requirements appear to be met. Keep up the good work. PCI Comments: 1. Pepsi Bottling Ventures ---A pennanent change is that the production line is moving to Raleigh near the middle of November 2002. Distribution will remain in operation, but there won't be production, only domestic. A drop request letter will be sent to the PT Unit. 2. Four SIU site inspections have been performed as of the time of this PCI: Pepsi, Acme, Fun -Tees, and Kayser Roth. 3. Chris Conner performed the chemistry laboratory analysis for COD, BOD, and TSS. He also collected the metals and transports them to TBL laboratory. 4. A new ISCO Glacier sample compositor was purchased. There was a total of four compositor, including the new one. 5. PreWin (computer program) was used to track the pretreatment data management of the PT program for Lumberton. 6. Way -Houser (formerly Willamette) will be an SIU by March 2003. Requirements: Recommendations: 1. Recommend updating the Spill Control Plan for Elkay 1. and Elkay 2. 2. All of the IUPs had Whole Effluent Toxicity (WET) testing requirements. Recommend dropping the WET by modifying the IUPs. NOD: YES 10 NOV: YES NO QNCR: YES N� POTW Rating: Satisfactory, ✓ Marginal Unsatisfactory PCI COMPLETED BY: Dale Lopez, Environmental Specialist Date: 11/07/02 Name and Signature of Reviewer Agency/Office/Telephone Date Grady Dobson NCDENR/Fayetteville/(910) 486-1541 11/07/02 //i `7 //ter s.i No Industrial Inspection was conducted during the PCI inspection INDUSTRY INSPECTION CODING: Trans.Code Main Program Permit Number MM/DD/YY Inspec.Type Inspector Fac.Type U I NI CIO to I I I I 1 1 / / I 1 l S 1 I21 1 . (DTIA) (TYPI) (INSP) (FACC) 1.Industry Inspected: 2.Industry Address: 3.Type of Industry/Product: 4.Industry Contact: Title: Phone: Fax: 5.Does the POTW use The Division Model Inspection Fonn or Equivalent? Yes / No 6.Did the POTW Contact Conduct the Following Parts of the Industrial Inspection Thoroughly? Comments: A. Initial Interview B Plant Tour C. Pretreatment Tour D. Sampling Review E. Exit Interview Industrial Inspection Comments: December 19, 2002 Mr. Dale Lopez Environmental Specialist Fayetteville Regional Office 225 Green Street -Suite 714 Fayetteville, NC 28301-5043 SUBJECT: Pretreatment Compliance Inspection (PCI) Response Lumberton WWTP NPDES Permit No. NC0024571 Robeson County Dear Mr. Lopez: A copy of the Pretreatment Compliance Inspection report for the inspection conducted on October 22, 2002 at the City of Lumberton Wastewater Treatment Plant (WWTP), dated November 7, 2002, was received on November 12, 2002. Two recommendations were noted. Recommendation #1: Updating the Spill Control Plans for Elkay #1 and Elkay #2. A SIU inspection for both plants was conducted on 11/7/02 and a requirement was listed in the inspection report, under Inspection Results, that an updated Spill Control Plan be completed and received by the City of Lumberton Pretreatment Division by December 18, 2002. As of today's date, the Plans have not been received but are in transit from both Elkays. When the City of Lumberton Pretreatment Division receives the updated Plans, I will notify you by e-mail of the receipt. Recommendation #2: All of the IUP's with Whole Effluent Toxicity (WET) testing requirements, drop the WET by modifying the IUP's. The WET requirement in all IUP's have been removed. Some other minor updates have been made as well in some of the IUP's. As soon as the fmal modifications are complete, the City of Lumberton Pretreatment Division will forward to you a copy of the modified permits. The effective date for all permits will be December 31, 2002. We appreciate you patience as we continue to complete the above modifications. If you have any questions or require clarification, please do not hesitate to contact me at (910) 671-3858. Sincerely, Karen H. Lewis Laboratory Supervisor cc: Deborah Gore, DWQ Pretreatment Unit Howard Revels, Environmental Services Director Jim Walters, Environmental Services Deputy Director LVAMILJ Subject: toxicity test results (Cd7dFR) Date: Thu, 19 Dec 2002 12:57:45 -0500 From: "Sandy Mort" <sandy.mort@ncmail.net> To: "dale.lopez" <dale.lopez@ncmail.net> ATU has completed the following toxicity test: facility: Red Springs WWTP test type: Cerio 7-day chronic FR Permit limit: 90% result: Chronic Value = 52.9% (FAIL on reproduction) Sandy Mort, sandy.mort@alncmail.net Environmental. Biologist NC DENR, Div. of Water Quality Aquatic Toxicology Unit 4401 Reedy Creek Road Raleigh, NC 27607 tel/vm: (919) 733-2136 x242 fax: (919) 733-9959 1 of 1 12/19/2002 2:35 PM