Loading...
HomeMy WebLinkAboutSW7960202_APPROVED PLANS_19960419STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW��, DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD w NOTES: 1. OWNER/DEVELOPER: WATERMARK ASSOCIATION OF ARTISANS, INC. MR. CLARKE MARTIN ECONOMIC DEVELOPMENT DIRECTOR NORTHEASTERN COMMUNITY DEVELOPMENT CORPORATION, INC. P.O. BOX 367 CAMDEN, NC 27921 2. PROJECT ZONING HC - HIGHWAY COMMERCIAL DISTRICT 3. PROPOSED DEVELOPMENT: 4.300 SQ. FT. WAREHOUSE ADDITION TO EXISTING 2-STORY COMMERCIAL STRUCTURE; 9.000 SQ. FT. TRAINING CENTER WITH ASSOCIATED PARKING, DRIVES, LOADING ZONES AND WASTEWATER DISPOSAL FACILITIES. 4. MINIMUM PARKING REQUIREMENTS; REQUIRED PARffltlG - 1 SPACE 500 SQ: FT. OF FLOOR AREA EXISTING STRUCTURE - 6.500 SQ. FT. PROPOSED TRAINING CENTER - 9,000 SO. FT. TOTAL AREA s 19,700 SQ. FT, TOTAL PARKING REQUIRED a 40 SPACES All PARKING AREAS AND DRIVES SHALL BE SURFACED WITH 2' 1-2 ASPHALT OVER r AGGREGATE BASE COURSE. ALL PARKING SPACES SHALL 9E SET OFF FROM REQUIRED YARDS WITH PRECAST CONCRETE CURB STOPS AS SHOWN. 5. MINIMUM BUILDING SETBACK: FRONT (SR. 12A0) - 15 FRONT (U.S. 158) - 25' SIDE - 10' REAR - 20' 6. TOTAL SITE AREA = 124,554 SQ. FT. (2.86 AC.) LOT COVERAGE BY IMPERMEABLE SURFACES (AT COMPLETION) = 49,000 SQ. FT MAXIMUM LOT COVERAGE BY IMPERMEABLE SURFACES = 50% PROPOSED LOT COVERAGE BY IMPERMEABLE SURFACES (AT COMPLETION) - 39.3X 7. UNDERGROUND U11UTIES MAY EXIST THAT ARE NOT SHOWN ON THIS PLAN. NOTIFY ULOCO (1-800-632-4949) AND HAVE UTILITIES FLAGGED PRIOR TO LAND DISTURBING ACTIVITIES. 8. SEPTIC SYSTEM DESIGN NOTES: A. EXISTING BUILDING AND WAREHOUSE ADDITION: THE EXISTING SEPTIC SYSTEM DRAINFlELD CONSISTS OF 3-1D0' L.F. DRAINLINES AT 3' O.C. ABANDON WESTERN 50' OF EXISTING DRAINFlELD AND REPLACE WITH 3 50 L.F. DRAINLINES 9' O.C. TO EXISTING AND PROPOSED LINES. B. PROPOSED TRAINING CENTER: DAILY FLOW FOR DESIGN IS 450 GPD BASED ON 10 EMPLOYEES AT 15 GPO/EMPLOYEE AND 30 STUDENTS AT 10 GPD/STUDENT. USE A 1250 GALLON PRECAST SEPTIC TANK AND PROVIDE 300 L.F. OF DRAINUN£ IN DRAINFlELD. (3 - 100 L.F. LINES ® 9' O.C.) RESULTING LTAR = 0.5 GPD/SQ. FT./DAY. C. SEE WASTEWATER SYSTEM INSTALLATION AND MAINTENANCE SPECIFICATIONS ON SHEET SP2 OF 2. 9. SEE SHEET SP2 OF 2 FOR STORMWATER MANAGEMENT AND SEDIMENTATION/ EROSION CONTROL NOTES. 1 Cps, e 0s 11, 01 �N O GO pG. ti• t',6yP W.e' 5z f. ti o se lGll r\e• pG B as yb, Gdso Oe- �.L1 COOVNG. 7'9 _ U.S. HIGHWAY 158______,eb 100' R/W — _- - 1 40% 59 INV. = 5.0 6{ EXISTING DRAINAGE DITCH �0 "9 POP 'ON LLQEXISTINGG GRADE R PROPOSED GRADE '3.7 DRAINAGE FLOW INTENT UTILITY POLE VEGETATIVE SWALE - . UTILITY LINE (SEE NOTE 7) APROX. FILL LIMITS NOW OR FORMERLY WINIFRED J. WOOD A— 0 GRAPHIC SCALE j✓,q{�o R/W EOP EOP ,o F ti BPG MSB W E w "wna�en: MWR MSB SHEET: SP 1 of 2 CAD FILE: 346900SI ( IN FEET ) 1 inch = 30 ft. 3469 N . - --- _ -� - - SE D E" ABC 2' BEYOND ESE O- FIVE AS EROSION CONTROL G - - _ 6' CONIC PRECAST SLOTTED CURB I 3' _- _. _+ram-_- VARIES 3' w.. 2" 12 ASPHALT PAVING Vn J�(�IVi F NI RA ___ FINISHED GRADE 6' A.B C / \\\ \' '/ / .U> \: \\/\ / /r COMPACTED SUBGRADE \/�\� ��\\ 24" 5\8" DIA. REBAR/ SECTION A -A SCALE: 1" = 2' 1/2' ISOLATION JOINT \ w �4 zi FINISHED GRADE \� �' R j FINISHED GRADE FINISHED AD d \ FINISHED GRADE � IA 2" 12 ASPHALT PAVING 6' x 6' W1.4 /W1,4 WELDED WIRE MESH 18' 4 •• \\\\j�\%\� \\� 3 1\1 1 3 \j\�i\\�\\�\\ .•v ` I: •f' \\\' III \� iIIZ,- COMPACTED SUBGRADE \ 4.5' 1- 4.5' �3000 PSI CONCRETE SECTION B-B SECTION D-D SCALE: I" = 2' +/- SCALE: 1"+�- NOTES: HAND TOOLED CONTRACTION JOINTS SHALL BE PLACED AT 10' INTERVALS. ALL CONTRACTION JOINTS SHALL BE FILLED NTH JOINT FILLER AND SEALER. �.. VARIES WTH DEPTH OF FILL --- i i 4' DRAINTLE\ 9TYP. BACKFlLL OVER GRAVEL OL � NON-SEIECT FILL 1 EXISTNG GRADE L__�� EXISTING GRADE \\\� / / \ / /\/ \\ /\/\✓ \\ / /\\ \/�� �\i //\/ \\ \ 2C MIN. 12' OF WASHED •57 STONE is' \2" ABOVE DRAINTLE AND SELECT FILL I L 6" BELOW DRAINTLE\/i./�\ = VAft1E5 SELECT FILL - - - - - - --OXOIL�TNE�S CO�DITI� - - - J MIN.-� - - - - - - _ - - - - REMOVE CLAEY SOILS AND �- REPLACE WITH TYPE 1 MATERIAL--- +7 - _ \ SCARIFY NATIVE SOIL AND MIX 3-6' BELOW REPLACEMENT AREA /�►� /�� WITH FILL MATERIAL TO AVOID SECTION C-C DEFINED SOIL BOUNDARY NOT TO SCALE WOVEN WIRE FENCE (MIN. 14 1/2 GAUGE, 101 MAX C MESH SPACING) •O•y' '4 gr0 NOTES 1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TOFENCE POSTS WITH WIRE TIES OR STAPLES 36' MIN. FENCE POST, 2. FILTER CLOTH TO BE FASTENED SECURELY TO DRIVEN, IC INTO WOVEN WIRE FENCE WITH TIES SPACED GROUND EVERY 24' AT TOP AND MID SECTION. 3, WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE OVER- LAPPED BY 6' AND FOLDED 4. MAINTENANCE SMALL BE PREFORMED AS NEEDED AND MATERAIL REMOVED WHEN >� w� OP 'BULGES' DEVELOP IN THE SILT FENCE. � MXNe �N � LNO RBL`D WOVEN WIRE FENCE (MIN 14 1/2 MAX C MESH SPACING) LAND b / b FLOW EMBED FILTER CLOTN z MIN 6' INTO GROUND b SILT FENCE SECTION T, .. L C / C A! POSTS: STEEL EITHER T OR U TYPE OR Y HARDWOOD FENCE: WOVEN WIFI 1/2 GA 6'MAIL. MESH OPENING GROUND FILTER CLOTH: FILTER X. MIRAF IOOX,STABILINKA T14ON OR APPROVED EQUAL PREFABRICATED UNIT: GEOFAB. ENVIROFENCE, OR APPROVED EQUAL 6*-3080 PSI CgICIII MAIL AM ELT 4%-BX REINIF. /5 RE W • B' EACH WAY 58' F_1 FLARE SIDES AT CONCRETE RAMP i I LOADING PLATFORM III I W' II I I I I I CONCRETE DRIVE 2' naffi AL�END SCALE : 1 = 4 -0 i III FLEW END 1 4 0 rrr�FL� .s i� B - &OW COMPACTED %IBORADE/ PSI 0I 4 CALL F.c. e.es' BOLATION7� H.C. ACCESS RAMP DETAIL NOT TO SCALE 6 j4 O 24 W/ 16- HOOK 6' 3000 ppel CONS FLOOR W/ AXE - W2.9/W2.9 WELDED N1RE FABRIC E 6 MIL POLYETHYLENE VAPOR BARRIER FOLD UP 3' AT EDGES AND TAPE JOINTS 6' COMPACTED GRANULAR FILL �- COMPACTED SUBGRADE (TYP.) --1' RIGID INSULATION. EXTEND V-4" VERTICALLY BELOW GRADE �µ DOWELS • 16' c-c 8 16- SECIO�a SCALE W t� F.G. IOAt F.G. 8.7 2Y SEDIMENTATION AND EROSION CONTROL NOTES 1, PROJECT DESCRIPTION: THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A 4,300 S0. FT. WAREHOUSE ADDITION (TO AN EXISTING 2-STORY 'II STRUCTURE), THE CONSTRUCTION OF A 9,000 SO, FT. 1-STORY TRAINING CENTER, AND THE CONSTRUCTION OF ASSOCIATED PARKING, DRIVES AND WASTEWATER DISPOSAL FACILITIES. THE PROJECT SITE IS A 2,86 AC. WEDGE FORMED BY THE INTERSECTION OF U.S. HIGHWAY 158 AND S.R. 1240. THE EXISTING TOPOGRAPHY IS FLAT WITH AN AVERAGE GROUND ELEVATION OF 7' +/-. THE NORTHERN PORTION OF THE SITE IS CURRENT-Y USED FOR AGRICULTURAL PURPOSES WHILE THE SOUTHERN PORTcw WAS DEVELOPED SEVERAL YEARS AGO. THE PROPOSED AREA OF LAND DISTURBANCE IS APPROXIMATELY 1.5 AC., 'MTH A TOTAL IMPERVIOUS COVER (AT PROJECT COMPLETION) OF 49,000 SO FT., OR APPROXIMATELY 39.3% OF THE TOTAL AREA, ADJACENT PROPERTY: NORTH - AGRICULTURAL USE (FARM FIELDS) ACROSS S.R. 1240 - RESIDENTIAL USE _. TEMPORARY EROSION CONTRL_ MEASURES: DUE TO THE TOPOGRAPHY A•i_ EXISTING SOILS. OFF -SITE SEDIMENTATION IS NOT ANTI':PATEC. HOWEVER, IF OFF -SITE SEDIMENTATION IS ENCOUNTERED, TEMPORARY EROSION CONTROL MEASURES WILL 8E EMPLOYE` A, NECESSARY 4. PERMANENT EROSION CONTROL MEASURES: A. PROVIDE STONE CHECK DAM- IN INFILTRATION BASIN OUTLETS AS SHOWN ON PLAN. B. EXTEND PARKING LOT BASE C,JRSE, 2' BEYOND EDGE OF PAVING AS SHOWN ON PLAN. C. STABILIZE ALL DISTURBED AREA AS OUTLINED IN ITEM 5 BELOW. STABWZATION AND LANDSCAPING- FINAL SLOPES IN ALL 3PAOED AREAS SHALL NOT EXCEED 3:1. ALL SEEDING AND SODDING SHALL BE IN PLACE WTHIN 30 DAYS OF PROJECT COMPLETION. A. FERTILIZER. APPLY 3,DDD-B/ACRE GROUND AGRICULTURE LIMESTONE AND 500 LB/ACRE 10-10-10 FERTILIZER. TOP DRESS WITH 50 LB/ACRE N TSOGEN. B. MULCH: APPLY 4,000 LB/A-,RE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL, SEEDING: 1_ TEMPORARY VEGFTAPUN. IF TEMPORARY SEEDING OCCURS DURING WATER, EARLY SPRING, OR FALL, APPLY 120 LB/ACRE RYE GRAIN. IF TEMPORARY SEEDING OCCURS ?JPING SUMMER, APPLY 4C LB/ACRE CENTPEEDGRASS. TEMPORARY VEGETATION MUST BE APPLIED WTTHIV 3C -AYS OF LAND DISTURBING ACTIVITY. c_ PERMANENT VEGE•AT=N APPLY COASTAL MIX CONSISTING OF _ -8 PENSACOLA BAHIAGRASS, AND 10 LB/ACRE GERMAN MILLET. APPLY PERMANENT SEEDNG BETWEEN APRIL 1 AND JULY 15. REFERTLZE THE I'LLOWNG APRIL WITH 50 LB/ACRE NITROGEN. D. SODDING: (IF REQUIRE' PERMANENT VEGETATION -SELECT COMPATIBLE SPECIE - PERMANENT SEEDED TYPE; INSTALL WITH LONGE: DIMENSION PERPENDICULAR TO THE SLOPE AND ."A°LE 'F NECESSARY; ROLL SOD IMMEDIATELY AND NA` T' 4'_ ALL STABILIZED AREAS SHOULD BE CHECKED AFTER EACH SIGNIFICANT RAINFALL EA'ENF RILLS AND GULLIES MUST BE REPAIRED, RE -SEEDED AND MULCHED AS SOON AS POSSIBLE. TEMPORARY DIVERSION'_ MAY BE NECESSARY UNTIL NEW PLANTS DEVELOP. BARE SPOTS MUST BE RELIMED, FERTILIZED, MULCHED AND RESEEDED AS PROMLI AS POSSIBLE. YEARLY REFERTILIZATION MAY Bt REQUIRED TO MAINTAIN PRODUCTIVE STANDS. STORMWATER MANAGEMENT PLAN NOTES 1. NARRATIVE (REFER TO SPI OF 2) A. EXISTING IMPROVEMENTS - (2-STORY COMMERCIAL STRUCTURE AND AN ASPHALT PARKING AREA. NO FORMAL STORMWATER COLLECTION SYSTEM CURRENTLY EXISTS. STOPITO DRAINAGE DRAINS BY SHEET G S.R. ACROSS GRASSED OPEN SPACES PTO DRAINAGE DITCHES ALONG S.R. 1240 AND U.S. HIGHWAY 158. P PROPOSED IMPROVEMENTS (WAREHOUSE ADDITION, TRAINING CENTER AND ASPHALT PARKING!DRIVFS). THE PROPOSED PARKING AREA AND DRIVES WILL BE GRADED TO SHEET FLOW STORMWATER INTO GRASSED STALES WHICH FLOW INTO AN INFILTRATION BASIN. THE INFILTRATION BASIN WILL OVERFLOW INTO THE EY'STING DRAINAGE DITCH ALONG U.S. HIGHWAY 158. A STONE CHECK DAM WLL ACT TO BLOCK SEDIMENT FLOW AND AID FILTRATION. 'HE PROPOSED TRAINING CENTER WLL USE GUTTERS TO DIRECT RVNOFT '0 THE NORTH SIDE OF THE BUILDING. THE STORMWATER WILL SHEE FLOW ACROSS A GRASSED OPEN SPACE (35') INTO A DRAINAGE SWA•E TO BE CONSTRUCTED ALONG THE NORTH PROPERTY LINE. 2. INFILTRATION BASIN DECO, _ATA: A. TOP OF BASIN ELEV. = E B. BOTTOM OF BASIN ELE1. + `_." O SIDE SLOPES = '" D. BASIN VOLUME - 2, 600 CUBIC FEET E. TOTAL IMPERVIOUS AREA GRAINING TO BASIN - 13,550 FT.2 F. VOLUME GENERATED FROM MPERAOUS SURFACES BY 1 INCH OF RAINFALL - 1,129 CUBIC FEE'. 3, NOTE: THERE ARE NO DIRECT CONNECTIONS (OF THIS DRAINAGE SYSTEM) TO SAWYER CREEK. WHICH IS A TRIBUTARY OF THE PASQUOTANK RIVER. F.F. ELEV. a 8.8' MSL y/ PRE -CAST SLOTTED CURB NOT TO SCALE FLOW NO.5 WA STONE Em WASTEWATER DISPOSAL SYSTEM SPECIFICATIONS A. SEPTIC TANK 1. PRE -CAST CONCRETE TANK SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE PLANS APPROVED BY THE N.C. DIVISION OF ENVIRONMENTAL HEALTH AND SHALL COMPLY WITH 15A NCAC 18A.1954 AS AMENDED THRU APRIL 1, 1993. 2. A MINIMUM 28-DAY CONCRETE COMPRESSIVE STRENGTH OF 3,500 PSI SHALL BE USED. 3. TANKS MANUFACTURED IN TWO SECTIONS SHALL BE JOINED AND SEALED AT THE JOINT BY USING A MASTIC, BUTYL RUBBER OR OTHER PLIABLE SEALANT THAT 15 WATERPROOF, CORROSION -RESISTANT AND APPROVED FOR USE IN SEPTIC TANKS. 4. TANK ACGFSS OPENINGS, CONCRETE RISERS AND LIDS SHALL BE PROVIDED AS NECESSARY TO ALLOW TANK ACCESS LIDS TO BE AT FINAL GRADE. EACH CONCRETE LID SHALL. HAVE AT LEAST ONE NO. 3 REBAR HANDLE. 5. GROUT ALL LOCATIONS WHERE PIPES EXIT THE TANKS WITH NON -SHRINK WATER -PROOF GROUT. 6. EXCAVATION SHALL BE BRACED AND SHEETED AS SOIL CONDITIONS DICTATE AND SHALL BE DEWATERED UNTIL INSTALLATION OF TANK MP S COMPLETE LEAKAGE TEST (IF REQUIRES BY THE REGIONAL HEAL-TH DEPARTMENT A. NOTIFY ENGINEER 1-3 DAYS PRIOR TO BEGINNING TEST, B. REMOVE SUFFICIENT WATER FROM TANK SUCH THAT THE WATER LEVEL IS AT LEAST 6 INCHES BELOW THE JOINT BETWEEN THE 2 TANK SECTIONS. C. MEASURE WATER LEVEL IN TANK. D. MEASURE WATER LEVEL IN TANK 24 HOURS LATER. E. MAXIMUM RISE IN WATER LEVEL SHALL BE ONE- HALF (1/2) INCH. 8. PROTECT TANKS FROM CAMAGE BY HEAVY EQUIPMENT AND VEHICULAR TRAFFIC. 9. BACKFILL WITH MATERIAL FREE FROM DEBRIS; COMPACT TO AT LEAST 90% OF MAXIMUM DRY DENSITY. 10, GRADE SITE TO PREVENT LONGING OF WATER ABOVE TANK. B. GRAINFIELD 1. INSTALL DISTRIBUTION BOX ON LEVEL AND COMPACTED MATERIAL AND AS SHOWN ON THE SITE PLAN IN THE DETAILS. 2, INSTALL DRAINFIELD IN ACCORDANCE WITH 15A NCAG 18A.1900 AS AMENDED THIRD APRIL 1, 1993, 3. SCARIFY NATURAL SOIL AT 3 TO 6 INCHES BELOW REPLACEMENT DEPTH PRIOR TO PLACING FILL MATERIAL IN DRAINFlELD TRENCH AREA. NOTIFY ENGINEER FOR INSPECTION PRIOR TO PLACING BACKFlLL IN TRENCHES. 4. FILL MATERIAL SHALL BE TYPE I AS APPROVED BY THE REGIONAL HEALTH DEPARTMENT PRIOR TO PLACEMENT. COMPACTION SHALL BE MINIMIZED TO THE EXTENT PRACTICABLE. 5. TRAFFIC SHALL BE PROHIBITED ON DRAINFlELD AND SIDE SLOPES. 6. VEGETATIVE COVER SHALL BE ESTABLISHED AND PROPERLY MAINTAINED BY THE OWNER. 7. SIDE SLOPES SHALL BE 3'1 (HORIZONTAL TO VERTCAL) MAXIMUM. 8. PROVIDE SUFFICIENT FILL MATERIAL TC ALLOW FINAL GRADE TO EXTEND AT LEAST 5 FEET BEYOND EDGE OF TRENCH BEFORE SLOPING TO NATURAL GRADE. C. OPERATION AND MAINTENANCE 1. THE OWNER WILL BE RESPONSIBLE FOR PROPERLY MAINTAINING THE WASTEWATER SYSTEM. 2, TANK SHOULD BE CHECKED ANNUALLY FOR ACCUMULATION OF SCUM AND/OR SLUDGE DEPTH AND FOR GENERAL CONDITION OF THE TANK AND COMPONENTS. SEPTIC TANK SHOULD BE PUMPED OUT WEN SLUDGE DEPTH REACHES 25X-35% OF LIQUID DEPTH UNLESS BUILDUP PROBLEMS WTH THE COLLECTION PIPE WARRANTS MORE FREQUENT PUMPING. 3. DRAINFlELD AND DISTRIBUTION BOX SHOULD BE CHECKED EVERY SIX MONTHS FOR EROSION AND SURFACING OF EFFLUENT. ROUTINE MOWNG SHOULD BE PERFORMED. D. GENERAL 1. PIPELINE CROSSINGS - W/ENEVER A WATERLINE CROSSES OVER A WASTEWATER PIPE, THE BOTTOM OF THE WATERLINE SHALL BE 18' ABOVE THE TOP OF THE WASTEWATER PIPE. IF THE 18' SEPARATION CANNOT BE MAINTAINED, OR IF THE WATERLINE MUST CROSS BELOW THE WASTEWATER PIPE, THEN BOTH WATERLINE AND WASTEWATER PIPE SHALL BE CONSTRUCTED OF DUCTILE IRON MATERIALS WTH JOINTS EQUIVALENT TO WATERLINE STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE POINT OF CROSSING. A SECTION OF WATERMAIN PIPE SHALL BE CENTERED AT THE POINT OF CROSSING. 2. LATERAL SEPARATIONS - WASTEWATER PIPES SHALL BE LAID AT LEAST 10 FEET LATERALLY FROM EXISTING OR PROPOSED WATERMAINS, UNLESS LOCAL CONDITIONS OR BARRIERS PREVENT A 10 FOOT LATERAL SEPARATION IN WHICH CASE: A. THE WASTEWATER PIPE IS LAID IN A SEPARATE TRENCH, WTH THE ELEVATION OF THE BOTTOM OF THE WATERMAN AT LEAST 18 INCHES ABOVE THE TOP OF THE FORCEMAIN; OR B. THE WASTEWATER PIPE IS LAID IN THE SAME TRENCH AS THE WATERMAIN WTH THE FORCEMAIN LOCATED AT ONE SIDE OF A BENCH OF UNDISTURBED EARTH, AND WITH THE ELEVATION OF THE BOTTOM OF THE WATERMAN AT LEAST 18 INCHES ABOVE THE TOP OF THE FORCEMAIN. 3. SETBACKS IN ACCORDANCE WITH 15A NCAC 18A.1950 SHALL BE MAINTAINED; SUCH SETBACKS FOR TREATMENT AND DISPOSAL SYSTEMS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: A. PUBLIC WELL - 100 FEET B. PRIVATE WELL - 1DO FEET OR AS REQUIRED BY CCHD C. BUILDING - 5 FEET D. PROPERTY LINE- 10 FEET E. WATERLINE - 10 FEET F. ANY OTHER NITRIFICATION FIELD - 20 FEET SETBACKS FOR COLLECTION SEWERS INCLUDE THE FOLLOWING: A. PUBLIC WELL - 100 FEET UNLESS CONSTRUCTED OF DIP NTH MECHANICAL JOINTS EQUIVALENT TO WATERMAIN STANDARDS IN WHICH CASE THE MINIMUM SETBACK IS 50 FEET, B. PRIVATE WELL - 50 FEET UNLESS CONSTRUCTED OF DIP WIN MECHANICAL JOINTS EQUIVALENT TO WATERMAN STANDARDS IN WHICH CASE THE MINIMUM SETBACK IS 25 FEET. C. PROPERTY LINE - 5 FEET D. ANY OTHER NITRIFICATION FIELD - 5 FEET 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND AVOIDING DESTRUCTION OF ALL E10STING UTILITIES IN THE VICINITY OF THE WORK. 2' MIN. �V � vw v� vv� v•a �••vr� vrvv m SLT N NOT TO SCALE a m 0 m O n T N (' O 3 O _ L C C 75 C O P o 00 0O O ` OW fOZnN w a N zm2Nm y n Ta nao«- m Z CL sO1wa • • � H m o � m � a ut � N m o c c • c m o E O 1 m m UL C JUL rn � c c w 0 • a r� v1 2 U O ai �r Z O 0 E- Q Z' U-� o O U)V>U a Q Q w Qq r+ YF� Q LL� Q !1/ 1 ILL (0 Q O Q w �•1Q-.y�i H4 E" 154 U m N Zo O _ F a U - 1 Wy O ac C Z 4 `Udeu �CSSI� i t .y. i 0 m •° AT ti 1-24 -aJ6i° E A'1'>s30` BPG MSB MWR MSB SHEET. SP2 2 OFtAil - f34 6900S2 TC . 34fi9