Compliance Inspection Report
Permit: SW7130606 Effective: 01/21/16 Expiration: 06/25/21
Project: Pronamic Inustries Facility
Owner: Flanders Filters Inc
County: Beaufort Adress: 1151 Page Rd
Region: Washington
Ohl— 8�/ City/State/Zip: Washington INC 27889
Contact Person: 11
Directions to Project: Qv%%����r pr�,�ry Title: // /� Phone:
�GtXvry @ aua'.f//.loot
At the intersection of Cherry Run Road and Page Road - Lot 8 & 9 Beaufort County Industrial Park on Page Road
Type of Project: State Stonmwater - HD - Detention Pond
Drain Areas: 1 - (Maple Branch) (03-03-06) (C;Sw,NSW)
On -Site Representative(s):
Related Permits:
Inspection Date: 07/14/2017 Entry Time: 09:OOAM
Primary Inspector: William J Moore
Secondary Inspector(s):
Reason for Inspection: Routine
Permit Inspection Type: State Stormwater
Facility Status: ❑ Compliant Not Compliant
Question Areas:
® State Slormwater
(See attachment summary)
Exit Time: 10:OOAM
Phone: 252-946-6481 Ext.264
t
Inspection Type: Compliance Evaluation
page: 1
permit: SW7130606 Owner -Project: Flanders Filters Inc
Inspection Date: 07h4/2017 Inspection Type Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
Inspection conducted 07/14/17 at Pronamic Industrial facility located at 1151 Page Rd near Washington, NC.
Water level in WP at/near PP level; water in pond bright green; vegetation inside perimeter of WP overgrown/not properly
maintained; vegetation on banks & outer slopes cut too close causing minor erosion & bare soils; inverted grade at bank
of emergency spillway appears to allow adjacent field to drain into WP. Drainage along back of plant site re-routed to
WP by grass swale. Grass swale not well defined; poorly maintained. Ouentin Mason, Plant Rep, stated that bright
green color in WP due to dye residue from exposed outside storage containers & recessed truck loading ramp washed
into pond during storm events.
Based on SIC code 3564 (air filters) facility should apply for and obtain coverage under Federal SW permit NCG03 -
Metal Fabrication. Monday, 07/17, follow-up with Tavern Dixon, (252)947-2538, company rep for AAF Flanders, local
company that owns facility. Facility being closed down/operation ceased immediately; company has hired
Environmental Consultant to assist with shut-down/clean up process.
Follow-up site visit with Flanders & Consultant TBA early August to discuss/resolve issues with WP & other permitting
requirements.
Built Upon Area Yes No NA NE
Is the site BOA constructed as per the permit and approval plans? ® ❑ ❑ ❑
Is the drainage area as per the permit and approved plans? ❑0 ❑ ❑
Is the BOA (as permitted) graded such that the runoff drains to the system? ® ❑ ❑ ❑
Comment: see summary comments
SW Measures Yes No NA NE
Are the SW measures constructed as per the approved plans? ❑ ®❑ ❑
Are the inlets located per the approved plans? ❑ 0 ❑ ❑
Are the outlet structures located per the approved plans? 0 ❑ ❑ ❑
Comment: see summary comments
Operation and Maintenance Yes No NA NE
Are the SW measures being maintained and operated as per the permit requirements? ❑ E ❑ ❑
Are the SW BMP inspection and maintenance records complete and available for review or provided to ❑ ❑ ❑ N
DWQ upon request?
Comment: see summary comments
Other WQ Issues Yes No NA NE
Is the site compliant with other water quality issues as noted during the inspection? ❑ ■ ❑ ❑