HomeMy WebLinkAboutSW7060712_HISTORICAL FILE_20201124STORMWATER DIVISION CODING SHEET
POST -CONSTRUCTION PERMITS
PERMIT NO.
SW
DOC TYPE
❑ CURRENT PERMIT
❑ APPROVED PLANS
le HISTORICAL FILE
❑ COMPLIANCE EVALUATION INSPECTION
DOC DATE
YYYYMMDD
ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
BRIAN WRENN
Director
NORTH CAROLINA
Environmental Quality
November 24, 2020
Dare County
Attention: Mr. Robert Outten, Manager
P.O. Box 1000
Manteo, NC 27954
Subject: Stormwater Permit Renewal
Stormwater Management Permit SW7060712
Hatteras Satellite Office
Dare County
Dear Mr. Outten:
WaV-zo
A Division of Energy, Mineral, and Land Resources file review has determined that
Stormwater Permit SW7060712 for a stormwater treatment system consisting of three
infiltration basins serving the Hatteras Satellite Office located at 50346 NC Hwy 12 in
Frisco, NC expires on April 9, 2021. This is a reminder that permit renewal applications
are due 180 days prior to expiration. We do not have a record of receiving a renewal
application.
Please submit a completed permit renewal application along with a $505.00 fee for
permit renewal. Permit application forms for renewal can be found on our website at:
https://cleq.nc.Eov/about/divisions/enemy-mineral-land-resources/enema-minerakland-
rules/stormwater-pro gram/post-co nstruction. North Carolina General Statutes and the
Coastal Stormwater rules require that this property be covered under a stormwater
permit. Failure to maintain a permit subjects the owner to assessment of civil penalties.
If you have questions, please feel free to contact me at (252) 948-3923. 1 will be glad to
discuss this by phone or meet with you. If you would like, I can e-mail you a copy of the
application form. You can request a copy by e-mailing me at roger.thorpe(a)ncdenr.gov.
Sincerely,
Roger K. Thorpe
Environmental Engineer
- North Carolina Department of Environmental Quality I Division of Energy. htlneral and Land Resources
Washington Regional Office 1 943 Washington Square Mall I Washington, North Carolina 17889
25794Nb481
kkRo
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
February 16, 2007
County of Dare
Attn: Mr. Testy Wheeler
PO Box 1000
Manteo, NC 27954
Subject: Stormwater Permit SW7060712
Hatteras Satellite Office
Dare County
Dear Mr. Wheeler:
Alan W. Klimek P.E. Director
Division of Water Quality
This office received a revised stormwater package for the subject project on November 29, 2006.
A preliminary review of the plans and specifications has been completed. Before a stomrwater permit can
be issued, the following items must be addressed:
1) The revised plans, along with more complete details of the drainage basins, show that not all
built -upon areas are captured and treated in the proposed infiltration basins. For high density
type projects, the stormwater rules require that all impervious surfaces be captured and
treated before leaving the site.
2) The revised soils report, along with site specific information regarding soil and water table
conditions, indicates less than 12-inches of separation between the bottom of basin no. 2
and the seasonal high water table (SHWT). The stormwater rules require 2-feet of separation
for infiltration systems; however, on a case -by -case basis, this office has permitted a few
projects where only 1-foot of separation was attainable. To my knowledge, the Division has
not issued stormwater permits for infiltration systems with less than 1-foot of separation. I
suggest that you have your consultants redesign the project to make sure that all proposed
infiltration systems for this site provide at least 12-24 inches of separation from the SHWT.
3) Provide revised plans, specifications, calculations and detailed stormwater narrative that
reflect all changes.
The above requested information must be received in this office prior to March 16, 2007, or your
application will be returned as incomplete. The return of this project will necessitate resubmittal of all
required items including the application fee. If you need additional time to submit the required information,
please mail or fax your request for time extension to this office at the Letterhead address.
If you have questions, please feel free to contact me at (252) 948-3919.
Sincerely,
William J. Moore
Environmental Engineer
Washington Regional Office
cc: Mulkey Engineers & Consultants
Dare County Planning/Inspections
;/4ashington Regional Office
N hCaro
aturai
North Carolina Division of Water Quality Washington Regional Office Phone (252) 946-6481 FAX (252) 946-9215 Customer Service
Intemet h2o.enr.state.nc.us 943 Washington Square Mall, Washington, NC 27889 1-877.623-6748
�O-MULKEY
ENGINEERS & CONSULTANTS
P❑ Box 331 27
RALEIGH, NC 27636
PHONE: 91 9-BS1 -1 91 2
FAx: 9 1 9-B 5 1- 1 9 1 B
LETTER OF TRANSMITTAL
To: Bill Moore
NCDENR-DWQ
934 Washington Square Mall
Washington, NC 27889
Re: Hatteras Satellite Office
I am sending you the following item(s):
ALCE ED
NOV 2 9 2006
®WQ-WARO
Date: November 28, 2006
252.946.6481
** FEDERAL EXPRESS **
Job No.: 2005354.00
COPIES
DATE
NO.
DESCRIPTION
2
Construction Drawing Set
2
Permit Application
2
(3) Infiltration Basin Supplements
2
Infiltration Basin Supplement explanations
2
Calculations Package
2
Responses to comments
These are transmitted as checked below:
® As requested ❑ For your use
❑ For approval ❑ For Signatures
® For review and comment ❑
Remarks:
Enclosed are the plans and Calculations for Hatteras Satellite Office. If you have any questions, feel free
to call me at 919.858.1823.
Copy to:
Signed: + A-�-
Christopher A. Flythe, El
-O=MULKEY
ENGINEERS & CONSULTANTS
NOV 2 9 2006
Responses to comments
First Review -September 26, 2006 ®WQ-WAR®
Meeting November 20, 2006
Bill Moore-DWQ
1. A vicinity map with the elements required on page 4 of the permit application is
shown on Sheet C1.00.
2. Drainage basins have been updated to reflect your comments. Thev are now
delineated to show areas that drain to an outlet, or to a control device. See the
attached full-sized exhibit sheet titled "Drainage Area Map".
3. The numbers in the application, supplements, and plans have been revised, and are
consistent.
4. The grassed swale has been revised and is now an infiltration basin. All stormwater
controls now provide 85% TSS removal.
5. Cross-section/details of all control measures are shown on Sheet C2.01.
6. A new geotechnical report has been given to address all comments, and is specific to
the DWQ requests (borings for the first few feet, permeability, and SHWT). Please
see the last section of the calculations booklet.
7. We have listed 1.5" as the design storm on the supplemental sheets since the only
two choices given in the parentheses next to it is for 1.5" for SA waters, or 1" for
others. We make it clear in the narrative as well as in the calculations for each basin
that since we do not provide a bypass structure, we must capture at least double the
required amount (3" minimum) to mitigate for this.
8. Justification has been provided not only in the Infiltration Basin Supplemental
package, but also throughout the narrative and in the calculations.
9. All requests are being provided with the updated package.
MULKEY INC. 6750 TRYON ROAD CARY. NC 27511 PO BOX 33127 RALEIGH. NC 27636 PH: 919-951-1912 FAX: 919-851-1918 www.MU4KEYINC.COM
0,
A.SIcitE:i F. Easlcj, Covear_
William G. Rev ir., Seeratary,
North Carolina Doi Lr..meut c<Environment ar:c1 Natural Resonrcas
County of Dare
Attn: Mr. Terry Wheeler
PO Box 1000
Manteo, NC 27954
Dear Mr. Wheeler.
September 26, 2006
Subject: Stormwater Permit SW70607 2
Hatteras Satellite Office
Dare County
Alan W. Klimek, P.E. Director
Division of VJaier Oualiry
This office received your stormwater application for the subject project on July -17, 2006. F.
preliminary review of the plans and specifications has been completed. Before a stomwater permit can
be issued, the following items must be addressed:
1) Provide vicinity map(see application checklist page 4 of 4).
2) Drainage basins should be delineated to reflect areas that drain to a particular outlet, or
control device (wetlands represent a separate DB; a portion of DB #1 drains to Infiltration
Basin 2).
3) The numbers provided in the application, calculation sheets and supplement/ Sheets do not
match (drainage basins areas, impervious areas, calculations should all be consistent).
4) Adequate stormwater controls should be provided for all impervious areas on site (swales
provide 35 % TSS removal rates and do not meet 85 % TSS requirement - specifically
East parking lot).
5) Provide cross-sections/details of all control measures.
6) Soils Report addresses details for structural purposes; hand borings, on -site, in the area
proposed for infiltration are needed to better address depth to seasonal high water table
(SHWT), permeability, estimated infiltration rates & overall expectation that the system
will work and meet design requirements of rules ( see list of design criteria on supplement
sheet).
7) Application package indicates that 3-inches of runoff is captured and stored in basins.
Information on supplement sheets and calculations do not support these storage
volumes.
8) Infiltration basins must meet all design requirements listed on supplement sheets. If a
particular design requirement is not met; justification must be provided that shows the
alternate design provides, at least equal, or better, treatment. (see specific requirements
on supplement sheet).
9) Provide revised plans, specifications, calculations and detailed stormwater narrative that
reflect all changes.
The above requested information must be received in this office prior to October 26. 2006, or your
application will be returned as incomplete. The return of this project will necessitate resubmittal of all
required items including the application fee. If you need additional time to submit the required information,
please mail or fax your request for time extension to this office at the Letterhead address.
North Carolina Division of Water Quality Washington Regional Office Phone (252) 946-6481 FAX (252) 946-9215
Internet: h2o.encstale.nc.us 943 Washington Square Mall, Washington, NC 27889
Customer Service
1-877-623-6748
e
rCaro
urM
An Equal Opportunity/Affirmative Action Employer — 50% Recycled110% Post Consumer Paper
County of Dare
September 26, 2006
Page Two
If you have questions, please feel free to contact me at (252) 948-3919.
Siinncer/ely,%
J/Y
William J. Moore
Environmental Engineer
Washington Regional Office
cc: ulkey Engineers & Consultants
Dare County Planning/Inspections
Washington Regional Office
It
p frlq. 7%17/06
OFFICE: USE ONLY r.
n,Date.Received_.._,.._,
Fee Paid
Permit Number -
B�n„ s I:'_,tl v lZ2=0
20
Sb✓ 0 7I 7-
00V 1 Q P006 State of North Carolina S„iaek "7/Zv/06
% Department of Environment and Natural Resources
DWQ-WARD Division of Water Quality
STORMWATER MANAGEMENT PERMIT APPLICATION FORM
This form may be photocopied for use as an original
I. GENERAL INFORMATION
1. Applicants name (specify the name of the corporation, individual, etc. who owns the project):
coup-rY Or QE
2. Print Owner/Signing Official's name and title (person legally responsible for facility and compliance):
( EZF_y VJHFE&; iG � (t7Ui✓'y MA111AEJtr2.
3. Mailing Address for person listed in item 2 above:
ZII 3vxrrc�N S-�2�Ei �Q (j0.t' /aoo
City: MAN-,-&' State: NG Zip:
Telephone Number:
7S-S800
4. Project Name (subdivision, facility, or establishment name -should be consistent with project name on plans,
specifications, letters, operation and maintenance agreements, etc.):
J4A7T?5et1 &%Tj7 "6 r-r,= (5) = rc-
5. Location of Project (street address):
5_0 34 & A/C, N WY
City: Zisco County: �AeF
6. Directions to project (from nearest major intersection):
7. Latitude: 35 ` lSr 3S" Al Longitude: 75" 3¢' _4,6" L✓ of project
8. Contact person who can answer questions about the project:
Name: Cli!(sZPNE i<rTdG Telephone Number: (90 ) B6f3-/ZZ3
II. PERMIT INFORMATION:
1. Specify whether project is (check one): New Renewal Modification
Form SWU-101 Version 3.99 Pagel of4
2. If this application is being submitted as the result of a renewal or modification to an existing permit, list the
existing permit number and its issue date (if known)
3. Specify the type of project (check one):
_Low Density ✓ High Density Redevelop _General Permit Other
4. Additional Project Requirements (check applicable blanks):
CAMA Major ✓Sedimentation/Erosion Control 404/401 Permit NPDES Stormwater
Information on required state permits can be obtained by contacting the Customer Service Center at
1-877-623-6748.
III. PROJECT INFORMATION
1. In the space provided below, summarize how stormwater will be treated. Also attach a detailed narrative
(one to two pages) describing stormwater management for the project.
SHL'-r f-' d Is U—nc, o To I H r 3 ONSITF �h zCre nc 3ns Ns s$S
2. Stormwater runoff from this project drains to the � Asg, ;&rANr, River basin.
3. Total Project Area: i •� acres 4. Project Built Upon Area: 24.1 %
cv- —[. Ac 4cz6j
5. How many drainage areas does the project have? 8
6. Complete the following information for each drainage area. If there are more than two drainage areas in the
project, attach an additional sheet with the information for each area provided in the same format as below.
Basin Informatton 4;
1 Drainage Area 1 . " t
¢j ,DramagewArea
Receiving Stream Name
PAMLICO ScuNJ
Receiving Stream Class
Sq twlc
5A
Drainage Area
0,479 Ac
O• -
Existing Impervious` Area
Proposed Impervious*Area
0 .Zo 8
O. Z03
% Impervious` Area (total)
Z iT = �3.4 %
d 3 3 ' v
Impervto_us Surface Aieay r,„
yy_ ,,; } "L Drainage Area l' ", r/
isi 'ri3jDramage Area
On -site Buildings
O )Zo Ac
—
On -site Streets
o o
0.0-77
On -site Parking
O , (..31
On -site Sidewalks
0.017
0 •O'LI
Other on -site
—
—
Off -site
Total: p,Zog
Total: 0,Zo3
Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas,
sidewalks, gravel areas, etc.
Form SWU-101 Version 3.99 Page 2 of
Basin Information
Drainage Area 3
Drainage Area 4
Receiving Stream Name
Pamlico Sound
Pamlico Sound
Receiving Stream Class
SA; HOW
SA; HOW
Drainage area
0.433 AC
0.093 AC
Existing Impervious Area
0.000 AC
0.019 AC
Proposed Impervious Area
0.330 AC
0.024
% Impervious Area (total)
76.21 %
46.02%
Impervious Surface Area
Drainage Area 3
Drainage Area 4
On -site buildings
0.095 AC
0.000 AC
On -site streets
0.075 AC
0.023 AC
On -site parking
0.125 AC
0.001 AC
On -site sidewalks
0.035 AC
0.000 AC
Other on -site
0.000 AC
0.000 AC
Off -site
0.000 AC
0.019 AC
Total:
0.330 AC
0.043 AC
Basin Information
Drainage Area 5
Drainage Area 6
Receiving Stream Name
Pamlico Sound
Pamlico Sound
Receiving Stream Class
SA; HQW
SA; HOW
Drainage area
0.245 AC
0.437 AC
Existing Impervious Area
0.000 AC
0.071 AC
Proposed Impervious Area
0.021 AC
0.063 AC
% Impervious Area (total)
8.577/.
30.66%
Impervious Surface Area
Drainage Area 5
Drainage Area 6
On -site buildings
0.000 AC
0.000 AC
On -site streets
0.013 AC
0.052 AC
On -site parking
0.008 AC
0.009 AC
On -site sidewalks
0.000 AC
0.002 AC
Other on -site
0.000 AC
0.000 AC
Off -site
0.000 AC
0.071 AC
Total:
0.021 AC
0.134 AC
Basin Information
Drainage Area 7
Drainage Area 8
Receiving Stream Name
Pamlico Sound
Pamlico Sound
Receiving Stream Class
SA; HQW
SA; HQW
Drainage area
1.409 AC
1.107 AC
Existing Impervious Area
0.000 AC
0.000 AC
Proposed Impervious Area
0.096 AC
0.000 AC
% Impervious Area (total)
6.81%
0.00%
Impervious Surface Area
Drainage Area 7
Drainage Area 8
On -site buildings
0.054 AC
0.000 AC
On -site streets
0.008 AC
0.000 AC
On -site parking
0.012 AC
0.000 AC
On -site sidewalks
0.015 AC
0.000 AC
Other on -site
0.007 AC
0.000 AC
Off -site
0.000 AC
0.000 AC
Total:
0.096 AC
0.000 AC
7. How was the off -site impervious area listed above derived? _P/Li /YAK S vz cw r/ c
IV. DEED RESTRICTIONS AND PROTECTIVE COVENANTS
The following italicized deed restrictions and protective covenants are required to be recorded for all
subdivisions, outparcels and future development prior to the sale of any lot. If lot sizes vary significantly, a table
listing each lot number, size and the allowable built -upon area for each lot must be provided as an attachment.
1. The following covenants are intended to ensure ongoing compliance with state stormwater management permit number
as issued by the Division of Water Quality. These covenants may not be
changed or deleted without the consent of the State.
2. No more than square feet of any lot shall be covered by structures or impervious materials.
Impervious materials include asphalt, gravel, concrete, brick, stone, slate or similar material but do not include wood
decking or the water surface of swimming pools.
3. Swales shall not be filled in, piped, or altered except as necessary to provide driveway crossings.
4. Built -upon area in excess of the permitted amount requires a state stormwater management permit modification prior to
construction.
5. All permitted runoff from outparcels or future development shall be directed into the permitted stormwater control
system. These connections to the stormwater control system shall be performed in a manner that maintains the integrity
and performance of the system as permitted.
By your signature below, you certify that the recorded deed restrictions and protective covenants for this project
shall include all the applicable items required above, that the covenants will be binding on all parties and persons
claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted
without concurrence from the State, and that they will be recorded prior to the sale of any lot.
V. SUPPLEMENT FORMS
The applicable state stormwater management permit supplement form(s) listed below must be submitted for each
BMP specified for this project. Contact the Stormwater and General Permits Unit at (919) 733-5083 for the status
and availability of these forms.
Form SWU-102
Wet Detention Basin Supplement
Form SWU-103
Infiltration Basin Supplement
Form SWU-104
Low Density Supplement
Form SWU-105
Curb Outlet System Supplement
Form SWU-106
Off -Site System Supplement
Form SWU-107
Underground Infiltration Trench Supplement
Form SWU-108
Neuse River Basin Supplement
Form SWU-109
Innovative Best Management Practice Supplement
Form SWU-101 Version 3.99 Page 3 of 4
VI. SUBMITTAL REQUIREMENTS
Only complete application packages will be accepter] and reviewed by the Division of Water Quality (DWQ).
A complete package includes all of the items listed below. The complete application package should be
submitted to the appropriate DWQ Regional Office.
1. Please indicate that you have provided the following required information by initialing in the space provided
next to each item.
Initials
• Original and one copy of the Stormwater Management Permit Application Form (AF
• One copy of the applicable Supplement Form(s) for each BMP CAF
• Permit application processing fee of $420 (payable to NCDENR) CAF
• Detailed narrative description of stormwater treatment/management OAF
• Two copies of plans and specifications, including: CAF
- Development/Project name
Engineer and firm
Legend
- North arrow
Scale
- Revision number & date
- Mean high water line
- Dimensioned property/project boundary -
- Location map with named streets or NCSR numbers
- Original contours, proposedcontours, spot elevations, finished floor elevations
- Details of roads, drainage features, collection systems, and stormwater control measures
- Wetlands delineated, or a note on plans that none exist
- Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations
Drainage areas delineated
- Vegetated buffers (where required)
VII. AGENT AUTHORIZATION
If you wish to designate authority to another individual or firm so that they may provide information on your
behalf, please complete this section.
Designated agent (individual or firm):, Key
Mailing Address: 6 7__ y,tPN i'ZoAD
City:_['p�y
Phone: (may
VIII. APPLICANT'S CERTIFICATION
State: A/ G zip: -07511
Fax: ( 9i9 ) 6,r1-OfP,
I, (print or type name of person listed in General Information, item 2) T z+ ' -J j1a,'`ce i G/
certify that the information included on this permit application form is, to the best of my knowledge, correct and
that the project will he constructed in conformance with the approved plans, that the required deed restrictions
and protective covenants will be recorded, and that the proposed project complies with the requirements of 15A
NCAC 21-I .1000.
Form SWU-101 Version 3.99
Page 4 of 4
Dater
I\
ATF9
r
County of Dare
Attn: Mr. Terry Wheeler
PO Box 1000
Manteo, NC 27954
Dear Mr. Wheeler:
Michael F. Easley, Governor
William G. Ross Jr, Secretary
North Carolina Department of Environment and Natural Resources
September 26, 2006
Subject: Stormwater Permit SW7060712
Hatteras Satellite Office
Dare County
Alim W. Klimek, P.E. Director
Division of Water Quality
This office received your stormwater application for the subject project on July 17, 2006. A
preliminary review of the plans and specifications has been completed. Before a stomrwater permit can
be issued, the following items must be addressed:
1) Provide vicinity map(see application checklist page 4 of 4).
�L) Drainage basins should be delineated to reflect areas that drain to a particular outlet, or
control device (wetlands represent a separate DB; a portion of DB #1 drains to Infiltration
Basin 2).
r/ 3) The numbers provided in the application, calculation sheets and supplement sheets do not
/ match (drainage basins areas, impervious areas, calculations should all be consistent).
v 4) Adequate stormwater controls should be provided for all impervious areas on site (swales
provide 35 % TSS removal rates and do not meet 85 % TSS requirement - specifically
East parking lot).
5) Provide cross-sections/details of all control measures.
pl'6) Soils Report addresses details for structural purposes; hand borings, on -site, in the area
proposed for infiltration are needed to better address depth to seasonal high water table
(SHWT), permeability, estimated infiltration rates & overall expectation that the system
will work and meet design requirements of rules ( see list of design criteria on supplement
sheet).
7) Application package indicates that 3-inches of runoff is captured and stored in basins.
Information on supplement sheets and calculations do not support these storage
/ volumes.
✓ 8) Infiltration basins must meet all design requirements listed on supplement sheets. If a
particular design requirement is not met; justification must be provided that shows the
alternate design provides, at least equal, or better, treatment. (see specific requirements
on supplement sheet).
9) Provide revised plans, specifications, calculations and detailed stormwater narrative that
reflect all changes.
The above requested information must be received in this office prior to October 26, 2006. or your
application will be returned as incomplete. The return of this project will necessitate resubmittal of all
required items including the application fee. If you need additional time to submit the required information,
please mail or fax your request for time extension to this office at the Letterhead address.
North Carolina Division of Water Quality Washington Regional Office Phone (252) 946-6481 FAX (252) 946-9215
Internet: h2o.enrstate.nc.us 943 Washington Square Mall, Washington, NC 27889
Customer Service
1-877-623-6748
One
Ma o
ral
An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper
County of Dare
September 26, 2006
Page Two
If you have questions, please feel free to contact me at (252) 948-3919.
Siinncer/ely,%
William J. Moore
Environmental Engineer
Washington Regional Office
cc: Mulkey Engineers & Consultants
Dare County Planning/Inspections
,/Washington Regional Office