HomeMy WebLinkAboutSW1210902_Plansheet - SCM Detail_20210930r) 1
J
W CD
��
0
n,
w
Q
0
cn
0
z
0
/
m
W
z
CD
w
Q
ry
I j
W
W
Q�
z/
Q Y
-5ry
0
w �I
-�
Om
m!
n
PROJECT DATA BLOCK
OWNER/SELLER
CAROLINAS LLC.
DUKE ENERGY
550 SOUTH TRYON STREET
CHARLOTTE, NC 28202
DEVELOPER/BUYER
MINKLES BROADPOINTE II LLC.
DAVID GIBBONS
7 CHERRYWOOD ROAD
LOCUST VALLEY, NY 11560
PERMIT NUMBER
NOT YET ASSIGNED
PROJECT LOCATION
MILLS RIVER, NORTH CAROLINA
COUNTY
HENDERSON COUNTY
PID
9642-18-7974
SITE COORDINATES
LAT:35.425583 LONG:-82.554972
PROPERTY SIZE
9642-18-7974 MINUS DUKE AREA
TOTAL: 25.07 ACRES
STREAM DISTURBANCES
89 LF
SOILS TYPE
BaB, BRADSON GRAVELLY LOAM, 2-7% SLOPES
Cu, COMUS (COLVARD) FINE SANDY LOAM
EnB, ELSINBORO LOAM, 0-3% SLOPES
Ro, ROSMAN LOAM
BUILT UPON AREA
5.24 AC, 228,111 SF (20.90%)
BUILDING SETBACKS
60' FRONT (OFF OTHER STREETS)
15' SIDE
20' BACK
BUILDING DIMENSIONS
260'x460' = 119,600 SF
LIGHTING REQUIREMENTS
TO BE PROVIDED BY DUKE ENERGY
TOWNSHIP
MILLS RIVER
EXISTING ZONING
MR-LI
DISTURBED AREA
7.17 ACRES
WATERSHED
FRENCH BROAD
USACE / NCDEQ
YES
PERMITS REQUIRED
PROPOSED GRADE. 2:1 MAX. SLOPE.
SEED AS SPECIFIED AND STABILIZE
W/ SC150 STAPLE PATTERN D OR
APPROVED EQUIVALENT.
EXISTING GRADE 4� 1 i� I I 1
NOTES:
'�11811E
STORM SEWER STRUCTURE
TABLE
STIR. #
RIM
INVERTS
DESCRIPTION
3' SQ. PRECAST CONC.
BOX, NCDOT STD. 840.46
DI-1
2059.54
NW 15" 2056.25
W/ NCDOT STD. 840.16
CAST IRON DROP INLET
FRAME AND GRATE.
3' SQ. PRECAST CONC.
SE 15" 2059.15
BOX, NCDOT STD. 840.46
DI-2
2063.68
NE 18" 2050.17
W/ NCDOT STD. 840.16
CAST IRON DROP INLET
FRAME AND GRATE.
3' SQ. PRECAST CONC.
BOX, NCDOT STD. 840.46
DI-3
2064.07
NW 15" 2060.50
W/ NCDOT STD. 840.16
CAST IRON DROP INLET
FRAME AND GRATE.
6' DIA. PRECAST CONC.
SE 15" 2055.78
MANHOLE, NCDOT STD.
JUNCTION-1
2058.38
SW 48" 2050.68
840.52 W/ CAST IRON
NE 48" 2050.64
RING AND LID, NCDOT
STD. 840.54
1. INSTALL MATTING AND SEED FILL SLOPE EVERY 8 VERTICAL FEET, AS SLOPE IS
CONSTRUCTED.
2. INSTALL FILL MATERIAL IN 8" LIFTS MAXIMUM AND COMPACT TO 95% MDD OR AS
RECOMMENDED BY THE OWNER'S GEO-TECHNICAL ENGINEERING CONSULTANT.
3. CONSTRUCTED FILL SLOPE SHOULD BE "BENCHED -IN" STEEPER THAN THE DESIGN
GRADE THEN CUT BACK TO THE DESIGNED SLOPE OR RECOMMENDED BY THE
OWNER'S GEO-TECHNICAL ENGINEERING CONSULTANT.
BENCHED FILL SLOPE
Know what's below.
Call before you dig.
SCALE: NOT TO SCALE
40 20 0 40 80
SCALE IN FEET
NOTES:
1. BOTTOMS AND SIDES OF DITCH TO BE SOD; SEE
LANDSCAPING PLAN ON SHEET C6.0
DITCH CROSS SECTION DETAIL
0
"I'll Ott I)an-410
SCALE: NOT TO SCALE
2070
2065
2055
2050
2045
Tl.
0
to
0
N
2075
2065
2060
2055
00
0
0
N
PROPOSED SURFACE
50 LF OF 18"
HDPE N-12
STM ® 1.00%
EXISTING
SURFACE
00
to
LO
to
Q
to
to
C.0
0
to
O
0
N
O
0
N
N
N
2080
2075
will Fit,
2065
2060
2055
O
co
co
O
N
0+00
STORM
PROFILE
- DRIVEWAY
1+00
CULVERT 1
VERT. SCALE:
1 "=8' HORZ. SCALE: 1 "=20'
2065
2060
1014141
2050
2045
2040
N
LO
0
N
2065
2060
15"
12
.00%
I,z4l.4.i
2050
OF 48"
N-12
0.84%
2045
2040
t
)0
V
V
0+00 1+00
STORM PROFILE - STREAMZDRIVEWAY CULVERT 2
VERT. SCALE: 1 "=8' HORZ. SCALE: 1 "=20'
0
Lq
L
0
to
0
6 c;
�LO
N
O O
r0 >
00
4 z
ILO >>
N;o
PROPOSED SURFACE
a
M II -
Nnao
13
N II
o0�z
ww
�EU1z
272 LF OF 15" HDPE N-12 STM ® 0.50%
✓�
t
✓�
t
f
t
EXISTING SURFACE
`............. . .
O___. ___. ___.
39 LF OF 18"
HDPE N-12
STM ® 3.03%
0
0 rn
rn rn
0 N
N 0
0 cfl
Lr) o
a�
0
0�
0
In 0
In 0
In 0
O N
O N
O N
O N
O N
O N
O N
N
N
(N
N
N
N
N
2070
2065
f�IiIIi7
2055
2050
2045
O
0+00 1+00 2+00 3+00 3+50
BACK OF TRUCK COURT STORM SEWER SYSTEM
VERT. SCALE: 1 "=8' HORZ. SCALE: 1 "=20'
m
z
O
O
w
0
w
Q
0
>
w
0
o U-
N
U)
�o z E
20 N --O o
U r9
Z
J ti
` - N 8 �
.� _2 O
> O 3
IDN Q
M n C O
in Q 00 U 3
'm
u J
co
Zj
w
1-4
~
rQ4
W
�
W
E--
Z
Ea�
>
W
C-1
U)
Z
W
W
�,
C
E-1
azz
w
O
O
M�
w4--1
T
NQ
mW
M�
W
u
ISSUED FOR: DATE: BY: z_
REVIEW 08/30/21 RDH
w
z
0
n
0
Q
m
JOB NO.
MNK2001.01A
Q
SHEET cj
E
C 20
.1 a
O