Loading...
HomeMy WebLinkAboutSW1210902_Plansheet - SCM Detail_20210930r) 1 J W CD �� 0 n, w Q 0 cn 0 z 0 / m W z CD w Q ry I j W W Q� z/ Q Y -5ry 0 w �I -� Om m! n PROJECT DATA BLOCK OWNER/SELLER CAROLINAS LLC. DUKE ENERGY 550 SOUTH TRYON STREET CHARLOTTE, NC 28202 DEVELOPER/BUYER MINKLES BROADPOINTE II LLC. DAVID GIBBONS 7 CHERRYWOOD ROAD LOCUST VALLEY, NY 11560 PERMIT NUMBER NOT YET ASSIGNED PROJECT LOCATION MILLS RIVER, NORTH CAROLINA COUNTY HENDERSON COUNTY PID 9642-18-7974 SITE COORDINATES LAT:35.425583 LONG:-82.554972 PROPERTY SIZE 9642-18-7974 MINUS DUKE AREA TOTAL: 25.07 ACRES STREAM DISTURBANCES 89 LF SOILS TYPE BaB, BRADSON GRAVELLY LOAM, 2-7% SLOPES Cu, COMUS (COLVARD) FINE SANDY LOAM EnB, ELSINBORO LOAM, 0-3% SLOPES Ro, ROSMAN LOAM BUILT UPON AREA 5.24 AC, 228,111 SF (20.90%) BUILDING SETBACKS 60' FRONT (OFF OTHER STREETS) 15' SIDE 20' BACK BUILDING DIMENSIONS 260'x460' = 119,600 SF LIGHTING REQUIREMENTS TO BE PROVIDED BY DUKE ENERGY TOWNSHIP MILLS RIVER EXISTING ZONING MR-LI DISTURBED AREA 7.17 ACRES WATERSHED FRENCH BROAD USACE / NCDEQ YES PERMITS REQUIRED PROPOSED GRADE. 2:1 MAX. SLOPE. SEED AS SPECIFIED AND STABILIZE W/ SC150 STAPLE PATTERN D OR APPROVED EQUIVALENT. EXISTING GRADE 4� 1 i� I I 1 NOTES: '�11811E STORM SEWER STRUCTURE TABLE STIR. # RIM INVERTS DESCRIPTION 3' SQ. PRECAST CONC. BOX, NCDOT STD. 840.46 DI-1 2059.54 NW 15" 2056.25 W/ NCDOT STD. 840.16 CAST IRON DROP INLET FRAME AND GRATE. 3' SQ. PRECAST CONC. SE 15" 2059.15 BOX, NCDOT STD. 840.46 DI-2 2063.68 NE 18" 2050.17 W/ NCDOT STD. 840.16 CAST IRON DROP INLET FRAME AND GRATE. 3' SQ. PRECAST CONC. BOX, NCDOT STD. 840.46 DI-3 2064.07 NW 15" 2060.50 W/ NCDOT STD. 840.16 CAST IRON DROP INLET FRAME AND GRATE. 6' DIA. PRECAST CONC. SE 15" 2055.78 MANHOLE, NCDOT STD. JUNCTION-1 2058.38 SW 48" 2050.68 840.52 W/ CAST IRON NE 48" 2050.64 RING AND LID, NCDOT STD. 840.54 1. INSTALL MATTING AND SEED FILL SLOPE EVERY 8 VERTICAL FEET, AS SLOPE IS CONSTRUCTED. 2. INSTALL FILL MATERIAL IN 8" LIFTS MAXIMUM AND COMPACT TO 95% MDD OR AS RECOMMENDED BY THE OWNER'S GEO-TECHNICAL ENGINEERING CONSULTANT. 3. CONSTRUCTED FILL SLOPE SHOULD BE "BENCHED -IN" STEEPER THAN THE DESIGN GRADE THEN CUT BACK TO THE DESIGNED SLOPE OR RECOMMENDED BY THE OWNER'S GEO-TECHNICAL ENGINEERING CONSULTANT. BENCHED FILL SLOPE Know what's below. Call before you dig. SCALE: NOT TO SCALE 40 20 0 40 80 SCALE IN FEET NOTES: 1. BOTTOMS AND SIDES OF DITCH TO BE SOD; SEE LANDSCAPING PLAN ON SHEET C6.0 DITCH CROSS SECTION DETAIL 0 "I'll Ott I)an-410 SCALE: NOT TO SCALE 2070 2065 2055 2050 2045 Tl. 0 to 0 N 2075 2065 2060 2055 00 0 0 N PROPOSED SURFACE 50 LF OF 18" HDPE N-12 STM ® 1.00% EXISTING SURFACE 00 to LO to Q to to C.0 0 to O 0 N O 0 N N N 2080 2075 will Fit, 2065 2060 2055 O co co O N 0+00 STORM PROFILE - DRIVEWAY 1+00 CULVERT 1 VERT. SCALE: 1 "=8' HORZ. SCALE: 1 "=20' 2065 2060 1014141 2050 2045 2040 N LO 0 N 2065 2060 15" 12 .00% I,z4l.4.i 2050 OF 48" N-12 0.84% 2045 2040 t )0 V V 0+00 1+00 STORM PROFILE - STREAMZDRIVEWAY CULVERT 2 VERT. SCALE: 1 "=8' HORZ. SCALE: 1 "=20' 0 Lq L 0 to 0 6 c; �LO N O O r0 > 00 4 z ILO >> N;o PROPOSED SURFACE a M II - Nnao 13 N II o0�z ww �EU1z 272 LF OF 15" HDPE N-12 STM ® 0.50% ✓� t ✓� t f t EXISTING SURFACE `............. . . O___. ___. ___. 39 LF OF 18" HDPE N-12 STM ® 3.03% 0 0 rn rn rn 0 N N 0 0 cfl Lr) o a� 0 0� 0 In 0 In 0 In 0 O N O N O N O N O N O N O N N N (N N N N N 2070 2065 f�IiIIi7 2055 2050 2045 O 0+00 1+00 2+00 3+00 3+50 BACK OF TRUCK COURT STORM SEWER SYSTEM VERT. SCALE: 1 "=8' HORZ. SCALE: 1 "=20' m z O O w 0 w Q 0 > w 0 o U- N U) �o z E 20 N --O o U r9 Z J ti ` - N 8 � .� _2 O > O 3 IDN Q M n C O in Q 00 U 3 'm u J co Zj w 1-4 ~ rQ4 W � W E-- Z Ea� > W C-1 U) Z W W �, C E-1 azz w O O M� w4--1 T NQ mW M� W u ISSUED FOR: DATE: BY: z_ REVIEW 08/30/21 RDH w z 0 n 0 Q m JOB NO. MNK2001.01A Q SHEET cj E C 20 .1 a O