Loading...
HomeMy WebLinkAboutNCG551223_Inspection_20210622United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction 1 IIV Code 1 2 15 NPDES yrlmolday Inspection Type Inspector Fac 1 3 1 NCG551223 111 121 21/06/22 117 181 c I 191 Ls] 20[j Type 211IIIII IIIIIIIIIII IIIIIII I IIII111IIIIIIII ILr6 Inspection 671 Work Days Facility Self -Monitoring I 70 I LJ Evaluation Rating I 711 B1 1 72 QA I N ----------Reserved------------------ I 73 74 7511 1 1 1 1 1 1 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 6132 Knightdale Boulevard 6132 Knightdale Blvd Knightdale NC 27545 Entry Time/Date 09:OOAM 21l06l22 Permit Effective Date 13/08/01 Exit Time/Date 10:00AM 21/06/22 Permit Expiration Date 18/07/31 Name(s) of Onsite Representative(spitles(s)1Phone and Fax Number(s) !11 Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Donna L Fowler,1008 Edenburgh's Keep Knightdale NC 2754511919-266-9934/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Other Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Jane Bernard DWRJNon Discharge Compliance Unit/919-791-42001 qc,,,2_ -0—i-sc-\4.-k_ k- -- 9 /(719/01/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date DocuSigned by: 1 VILIAt,SSa f . 1144 • L 9/28/2021 916E 1 4F EPA Form $3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 NPDES yr/mo/day NCG551223 Ill 121 21/06/22 117 Inspection Type 181s1 (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Violations noted during the inspection were as follows: 1. Treatment system operation: The wastewater treatment system shall be maintained at all times to prevent seepage of sewage to the surface of the ground. At the time of this inspection effluent was ponding before the rip -rap in a large area. 2. System Components: All system components, including but not necessarily limited to, septic tanks, surface sand filters, other filter components, pump/recirculation tanks, controls and alarms, disinfection units, dechiorination apparatus, and the outfalls shall be maintained at all times and in good operating order. a. At the time of this inspection the six peat bio-filters were ponded and heavily saturated with sludge. b. In addition to the failing bio-filters the water meter has been failing for years. Flows for this facility can only be determined by the water bills. Please submit the water bills for the calendar 2018 (prior to covid) within 30 days of this NOV. 3. Chlorine tablets in the chlorinator: Part 1, Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect the tablet chlorinator weekly to ensure there is an adequate supply of tablets for continuous and proper operation. Section D (4) requires the permittee to maintain all system components, including...disinfection units...at all times and in good operating order. The inspector observed the chlorinator filled to the top with old tablets that have absorbed moisture and fused together. As a result, the tablets would not move down in the tubes as necessary for proper disinfection. 4. Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform and Total Residual Chlorine. Failure to monitor the effluent discharge as required is a violation of NPDES General Permit NCG550000. a. The annual monitoring requirement for calendar year 2020 was not completed. b. The annual chlorine residual for calendar year 2021 was not completed. 5. Limit Exceedance Violation(s): Sample Location Parameter Date Limit Value Analytical Result Unit of Measure Type of Violation Effluent Effluent Effluent Effluent Fecal Coliform 12/19/19 Fecal Coliform 12/19/19 Fecal Coliform 6/21/21 Fecal Coliform 6/21/21 200/100 2420 mL Monthly Average Fecal Coliform 400/100 2420 mL Daily Maximum Fecal Coliform 200/100 2420 mL Monthly Average Fecal Coliform 400/100 2420 mL Daily Maximum Fecal Coliform Both samples (12/19/19 and 6/21/21) listed above included analyte qualifiers which state the following; "Reported value should be considered a minimum estimate since it is the maximum reportable number for this method based on the sample volume used. The true value is likely greater than the value reported." 6. Discharge outlet location. The permittee is required to conduct a visual review of the outfall location at least twice each year (one at the time of sampling) to ensure that no visible solids or other obvious evidence of system malfunctioning is observed. Any visible signs of a malfunctioning system shall be documented and steps taken to correct the problem. The discharge pipe was visible and accessible the day of the inspection but effluent was ponding before the rip -rap. Pee gravel had been added to the area but Eagle's Express staff nor the contractor have any knowledge as to how it got there or why. Even with the addition of the gravel there is a large area that is saturated and draining to the edge of the parking lot. Page# 2 Permit: NCG551223 Inspection Date: 06/22/2021 Owner - Facility: 6132 Knightdale Boulevard Inspection Type: Compliance Evaluation Other Comment: Yes No NA NE Page# 3 11 ■ I■ - - ■ • • ■ • ■ a ■- 1 • • • A1• • ▪ • • i • • • iir.• • J il I °I1 • i arl _ ..• , • 1.14101t ml' 4. . _ •E'11:7: : • ••: • - ntog21. . .1' . • .1%• At . r.411.1%1EL LL ■ •■�f�1■ Y I. '• r' ■ • • • i ■ i` � " � � � ■DTI m ido ` J .,= ; • • i . ... . f • .r..Frif .