HomeMy WebLinkAboutNC0005762_Technical Assistance_20070608Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality June 8, 2007 Anthony Chavis, Operator in. Responsible Charge J.P. Stevens, Wagram Plant WWTP NCSR 1407 Wagram, N.C. 28396 Subject: Technical Assistance Report NPDES Number NC0005762 Scotland County Dear Mr. Chavis, This is to document that technical assistance has been given regarding the operation of the downsized wastewater treatment facility. I met with you and backup operator Ronald Locklear on May 24, 2007. The technical assistance was conducted to reevaluate the large wastewater facility operations and to give recommendations regarding the plant modifications and the proper operation of this low influent flow. (7 MGD reduced to less than 1 MGD) See the summary comments in the report. As always, you are to be commended for requesting assistance when needed, in order to protect water quality by achieving and maintaining permit compliance. If you have questions concerning this report or if this office can be of additional assistance, please contact me at 910-433-3309. Sincerely, Don Register Wastewater Treatment Consultant Cc: Yancy Helton, Director of Engineering Jerry Rimmer, Technical Assistance Supervisor FRO files NorthCarolina Naturally North Carolina Division of Water Quality 225 Green Street — Suite 714 Fayetteville, NC 28301-5043 Phone (910) 433-3300 Customer Service Internet: ncwaterquality.org FAX (910) 486-0707 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper United States Environmental Protection Agency EPA nr/`1 Washington, D.C. 20460 Water Compliance Inspection Report , Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 I NI 2 151 3I NC0005762 111 121 07/05/24 117 Type Inspector Fac Type 181 DI 191 SI 20I II I 1 I I 1 I I l l 1 I I I 1 1 166 Remarks 211 1 I 1 I 1 1 l I 1 1 I 1 1 1 1 1 1 I 1 I l• 1 I' I l I l 1 I I Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 5.0 169 70 13 Il. 711 1 721 N I 731 174 751 I II I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) . Wagram plant NCSR 1407 Wagram NC 28396 Entry Time/Date 08:15 AM 07/05/24 Permit Effective Date .05/08/01 Exit Time/Date 10:30 AM 07/05/24 Permit Expiration Date 09/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) / / / Anthony Lynn Chavis/ORC/910-369-4244/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Yancy D Helton,PO Box 338 Wagram NC 28396//910-369-4111/9103694380 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) - - Other Section D: Summary of Findinq/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Don Register FRO WQ//910-433-3300 Ext.709/dieift.) 34 �L`,7 Signature of Management Q Reviewer Agency/Office/Phone and Fax Numbers Date >l 6-/2 Q EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. • Page # 1 � wpoEn v�mmmov ' ' | 11 12 / ", |� 07/05/24 / ^ Inspection Type 18 IDI (cont�) .z 'Section D:'Summary nfFinding/Comments (Attach adddiona sheots of narrative and checklists oonecessary) ' A walk-through tour of the treatment facility. 1. The climber barscreen was operating continuously instead of when needed. (soggestibn) ' A timer or level, �operation for noapparent reason. There is not enoughfood bb supportboth the aeration and the EQbaa (suggestiort);Stop basin. 3. Currently the plans are to bypass the.-aeratio'n basin by pumping, directly from the EQ basin'to the splitter box to the ' final clarifiers. 4. Operate both mixers and only enough aerators in the aereation or EQ, basin to maintain'a mixed liquor dissolved oxygen at-.1.573 mg1l. After obtaining historical readings-, timers could be used to operate only the aerators -that are needed and when they are needed. 5. The *post aerator operates continuouly, instead. of when needed to meet permit limits. The wastewater treatment olant,operated under it's current permitted fl6w and,genero.us limits, appears to be very little and iarunning itself. Efficient. operations could make aPig difference inthe cost of operating thhsfookx ' I will be available to help with any of the suggested ideas if you wish to discuss them further. / " ^ � ' Pago# 2