HomeMy WebLinkAboutNC0005762_Inspection_20150814kVA NCDENR North Carolina Department of Environment and Natural, Resources Pat McCrory Governor August 14, 2015 Ronald Locklear Cascades Holding US Inc PO Box 338 Wagram, NC 28396 SUBJECT: 7/24/2015 Compliance Evaluation Inspection Cascades Holding US Inc Wagram plant Permit No: NC0005762 Scotland County Dear Mr. Locklear : Donald R. van der Vaart Secretary 4 Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on 7/24/2015. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Senior Specialist, of the Fayetteville Regional Office. The facility was found to be in Compliance with permit NC0005762. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Comments • Facility has not had an effluent discharge since August 2014. o Maintenance Togs and laboratory records are being maintained. Maintenance Togs, laboratory records (including process control records), and ORC Togs are being maintained. • The Division of Water Resources recommends that all wastewater equipment be maintained as best as possible for future use. It is also understood that Cascades Holdings US Inc. and Scotland County are in discussions about transferring the ownership of the.WWTP to the county. Fayetteville Regional Office 225 Green Street, Suite 714, Fayetteville, North Carolina 28301-5095 Main Phone: 910-433-3300 1 Internet: http://www.ncdenr.gov An Equal opportunity \ Affirmative Action Employer— Made in part by Recycled Paper r Mr. Locklear Page 2 August 14, 2015 Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3327. Sincerely, . & ' Mark Brantley Environmental Senior Specialist Division of Water Resources Water Quality Regional Operations Section cc: Ronald Gene Locklear, ORC Central Files ayF t ville Files. United States Environmental Protection Agency EPA Washington, D.C.20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 • Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 Er 2 h I 3 I NC0005762 111 121 15/07/24 I17 Type 18 I r. i I I I I I Inspector Fac Type 19 Ls] I 20I i 211111 I I I I I I II I I I I I I I I I I I I I I I I I I II I I I I 1 l66 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA 67I I 70I I 71 I 1 72 1.1,1 I Reserved 731' I I74 7511 I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) • Wagram plant NCSR 1407 Wagram NC 28396 Entry Time/Date 10:OOAM 15/07/24 Permit Effective Date 14/11/01 Exit Time/Date 12:30PM 15/07/24 Permit Expiration Date 19/07/31 Name(s) of Onsite Representative(s)/tles(s)/Phone and Fax Number(s) /// Ronald Gene Locklear/ORC/910-369-4392/ Other Facility Data 3 Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Donald Locklear,PO Box338 Wagram NC 283961/910-369-4392/9103694399 = No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Facility Site Review • Permit . Operations & Maintenance Records/Reports .® Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists'as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers, Date Mark Brantley FRO WQ//910.433-3300 Ext.727/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date BeJjnS Hinson /) �a , FRO WQ//910-433-3300 Ext.72E g' Jq_—' Q �a ,ail d AC347) at `71,a44,0 i EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type 3I NC0005762 111 121 15/07/24 I 1 % 18 (; (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Comments °Facility has not had an effluent discharge since August 2014. •Maintenance Togs and laboratory records are being maintained. Maintenance Togs, laboratory records (including process control records), and ORC Togs are being maintained. •The Division of Water Resources recommends that all wastewater equipment be maintained as best as possible for future use. It is also understood that Cascades Holdings US Inc. and Scotland County are in discussions about transferring the ownership of the VWVfP to the county. Page# 2 Permit: NC0005762 Owner - Facility: Wagram plant Inspection Date: 07/24/2015 Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or Tess). Has the permittee submitted a new application? Is the facility as described in the, permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Record -Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on,DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator each shift? Is the ORC visitation log available and current? Is the ORC certifiedat grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy Of the current NPDES permit available on site? Yes No NA NE ❑ ❑ 11 ❑ ® ❑ ❑ ❑ ❑ ❑ • ❑ 11 ❑ ❑ ❑ II ❑ ❑ ❑ Yes No NA NE II El ❑ ❑ ❑ ❑ 11 ❑ Yes No NA NE ® ❑ ❑ ❑ ® ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ 11 ❑ ❑ ❑ 1 �:.❑ 0 0 O 0110 ❑ • 0 ▪ El El 0 ▪ El ❑ ❑ ▪ :❑_ ❑ ❑ 1 ❑ "❑ .❑ Page# 3 Permit: NC0005762 Owner - Facility: wagram plant Inspection Date: 07/24/2015 Inspection Type: Compliance Evaluation Record Keeping Facility has copy of previous year's Annual Report on file for review? Comment: Pump Station - Influent Is the pump wet well free of bypass lines or structures? Is the wet well free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? Comment: Equalization Basins Is the basin aerated? Is the basin free of bypass lines or structures to the natural environment? Is the basin free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Are audible and visual alarms operable? # Is basin size/volume adequate? Yes No NA NE ❑ ❑ ■ ❑ Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ® ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ■ ❑ ❑ .❑ ■ 0 Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ 0 ❑ ❑. ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ .❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ Comment: The water level in the EQ Basin is so low that air pockets (6 pockets) have formed under the liner. Please have the structure evaluated by a professional enqinner to determine the correct way to repair the structure before the eq basin is placed back into service. Secondary. Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Yes No NA NE IN ❑ ❑ ❑ • ❑ ❑ CI ■ 0 ❑-❑ ❑ ❑ ■ ■ ❑ ❑ Page# 4 Permit: NC0005762 Owner - Facility: Wagram plant Inspection Date: 07/24/2015 Inspection Type: Compliance Evaluation Secondary Clarifier Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately % of the sidewall depth) Yes No NA NE • ❑ ❑ ❑ E10110 ❑ ❑ MI ❑ Comment: No discharge from clarifers. Only one darner is in operation to maintain it in working order. Two other clarifers are off line and are in need of repair. Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/I) Comment: Yes No NA NE Ext. Air Surface MI 0 0 El ❑ ❑ • ❑ ▪ ❑ ❑ ❑ ® ❑ ❑ ❑ IN ❑ ❑ ❑ • ❑ ❑ ❑ Page# 5