Loading...
HomeMy WebLinkAboutNC0020656_Inspection_20150624ATA NCDENR , North Carolina Department of Environment and Natural Resources Pat McCrory Governor June 24, 2015 Robert A. Ellis City of Laurinburg PO Box 249 Laurinburg NC 283530249 SUBJECT: 5/28/2015 Compliance Evaluation Inspection City of Laurinburg Leith Creek WWTP Permit No: NC0020656 Scotland County Dear Mr. Ellis: Donald R. van der Vaart Secretary Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on 5/28/2015. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Senior Specialist, of the Fayetteville Regional Office. The facility was found to be in Compliance with permit NC0020656. The cooperation of Mr. Ricky Odum, Facility Back-up ORC, was greatly appreciated. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Comments > The facility was clean and neat in appearance at the time of the inspection. During the walk through portion of the inspection the effluent was observed to be clear and free of solids. > Maintenance records and log books were neat and up to date. > Laboratory records for the month ofJanuary 2015 were reviewed. Two very minor transcription• errors were found but they did not affect permit compliance. Please be careful when entering data into the eDMR database to ensure proper results are reported. L Fayetteville Regional Office 225 Green Street, Suite 714, Fayetteville, North Carolina 28301-5095 Main Phone: 910-433-3300 \ Internet: http://www.ncdenr.gov An Equal Opportunity \ Affirmative Action Employer— Made in part by Recycled Paper Mr. Ellis Page 2 June 24, 2015 Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3327. Sincerely, Mark Brantley Environmental Senior Specialist Division of Water Resources NCDENR cc: Robert A. Ellis, ORC Central Files Fayetteville Files) United States EnvironmentalProtection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 u 2 u 3 1 NC0020656 111 12 1 15/05/28 117 Type 18 i ,. I III Inspector Fac Type 19 I G 1 201 2111111111111IIIIIIII1I1111mill Hill! II r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA 671 1 70 I, I 71 I �, LI 72 I �,) l-1 L� Reserved 73 • I I. 174 751 1 1 1 I 1 1 1 .180 Section B: Facility Data - Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Leith Creek WWTP Hall St Extension Laurinburg NC 28352 Entry Time/Date " 10:15AM 15/05/28 Permit Effective Date 14/11/01 Exit Time/Date 12:45PM 15/05/28 Permit Expiration Date 19/08/3.1 Name(s) of Onsite Representative(s)Ttles(s)/Phone and Fax Number(s) /// Robert A. Ellis/ORC/910-277-0214/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Robert A. Ellis,PO Box 249 Laurinburg NC 2835.30249//910-276-9374/9102773633 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Facility Site Review II Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) . Name(s) and Signature(s) of Inspectors) Agency/Office/Phone and Fax Numbers Date Mark Brantley FRO WQ//910-433-3300 Ext.727/ `;i eA?/ `lede Signature of.Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date El.n=so659 ivilowley,RO WQ//910-433-300 Ext.72E 6 -_02, i- 1 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 NPDES NC0020656 yr/mo/day Inspection Type, 121 15/05/28 117 18 I „ (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Comments ❑ The facility was clean and neat in appearance at the time of the inspection. During the walk through portion of the inspection the effluent was observed to be clear and free of solids. ❑ Maintenance records and log books were neat and up to date. 0 Laboratory records for the month of January 2015 were reviewed. Two very minor transcription errors were found but they did not affect permit compliance. Please be careful when entering data into the eDMR database to ensure proper results are reported. Page# 2 Permit: NC0020656 Owner - Facility: Leith Creek VVWTP Inspection Date: 05/28/2015 Inspection Type: Compliance Evaluation Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector grantedaccess to all areas for inspection? Comment: Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing. analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Yes No NA NE ® ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ■ ❑ ® ❑ ❑ ❑ ❑ ❑ ® ❑ ® ❑ ❑ ❑ ® ❑ ❑ ❑ Yes No NA NE II El ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ 11 ❑ ❑ ❑ II ❑ ❑ ❑ • 11 ® ❑. ❑ ❑ O El 0 El ❑ ❑ 11 ❑ Page# Permit: NC0020656 Owner - Facility: Leith Creek VWVfP Inspection Date: 05/28/2015 Inspection Type: Compliance Evaluation Record Keeping Facility has copy of previous year's Annual Report on file for review? Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Yes No NA NE ❑ ❑ ❑II Yes No NA NE 11 ❑ ❑ ❑ MI ❑ ❑ ❑ ® ❑ ❑ ❑ ❑ ❑ I ❑ Yes No NA NE 0 ® ❑ ❑ ❑ IN ❑ ❑ ❑ • ❑ ❑ ❑ 11 El El El Grit Removal Yes No NA NE Type of grit removal a.Manual ❑ b.Mechanical 1 Is the grit free of excessive organic matter? 1 ❑ ❑ ❑ Is the grit free of excessive odor? II 0 ❑ 0 # Is disposal of grit in compliance? MI 0 ❑ 0 Comment: Pump Station - Influent Yes No. NA NE Is the pump wet well free of bypass lines or structures? I ,❑ ❑ ❑ Is the wet well free of excessive grease? ® ❑ . ❑ 0 Are all pumps present? • ❑ ❑ ❑ Page# 4 Permit: NC0020656 Owner - Facility: Leith Creek VWVT'P Inspection Date: 05/28/2015 Inspection Type: Compliance Evaluation Pump Station - Influent Yes No NA NE Are all pumps operable? 111 ❑ ❑ ❑ Are float controls operable? ® ❑ ❑ ❑ Is SCADA telemetry available and operational? • ❑ ❑ ❑ Is audible and visual alarm available and operational? ❑ ❑ ❑ • Comment: Equalization Basins Yes No NA NE Is the basin aerated? ® ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? ® ❑ ❑ ❑ Is the basin free of excessive grease? IN ❑ ❑ ❑ Are all pumps present? ® ❑ ❑ ❑ Are all pumps operable? ® ❑ ❑ ❑ Are float controls operable? ❑ ❑ ❑ 11 Are audible and visual alarms operable? ❑ ❑ ❑ MI # Is basin size/volume adequate? II ❑ ❑ ❑ Comment: Basin is only used duing rain events that cause high flows. Currently aerators are out of service because the copper electrical lines have been stolen. Secondary Clarifier - Yes No NA NE Is the clarifier free of black and odorous wastewater? ..® 0 ❑ " ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? 11 ❑ ❑ .❑ Are weirs level? IN ❑ ❑ ❑ Is the site free of weir blockage? • 1 ❑_ _ ❑ El Is the site free of evidence of short-circuiting? ® ❑ . ❑ ❑ Is scum removal adequate? • ❑ ❑ ❑ Is the site free of excessive floating sludge? • ❑ . ❑' ❑ Is the drive unit operational? •❑ ❑ ❑ Is the return rate acceptable (low turbulence)? ® ❑ ❑ . ❑ Is the overflow clear of excessive solids/pin floc? ® ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately %4 of the sidewall depth) 1 ❑ ❑ ❑ Comment: Aeration Basins Mode of operation Yes No NA NE Ext. Air Page# 5 Permit: NC0020656 Owner -Facility: Leith CreekWWTP Inspection Date: 05/28/2015 - Inspection Type: Compliance Evaluation Aeration Basins Yes No NA NE Type of aeration system Surface Is the basin free of dead spots? • 0 0 0 Are surface aerators and mixers operational? - ■ 0 0 0 Are the diffusers operational? 0 0 • 0 Is the foam the proper color for the treatment process? ® 0 0 0 Does the foam cover less than 25% of the basin's surface? _ 1 0 0 0 Is the DO level acceptable? 110 0 0 Is the DO level acceptable?(1.0 to 3.0 mg/I) ®\ 0 0 0 Comment: Oxidation Ditches Yes No NA NE Are the aerators operational? ® 0 0 0 Are the aerators free of excessive solids build up? -• 0 0 0 # Is the foam the proper color for the treatment process? ® 0 0 0 Does the foam cover less than 25% of the basin's surface? II 0 0 0 Is the DO level acceptable? ® 0 0 0 Are settleometer results acceptable (> 30 minutes)? 000111 Is the DO level acceptable?(1.0 to 3.0 mg/I) ® 0 0 ❑ Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) • 0 0 0 Comment: De -chlorination - Yes No NA NE Type of system ? Gas Is the feed ratio proportional to chlorine amount (1 to 1)? • 0 0 0 Is storage appropriate for cylinders? 1 0 0 0 # Is de -chlorination substance stored away from chlorine containers? • 0 0 0 Comment: Are the tablets the proper size and type? 0 0 II 0 Are tablet de -chlorinators operational? 0 0 0 Number of tubes in use? Comment: Page# 6 Permit: NC0020656 Owner - Facility: Leith Creek W1NTP Inspection Date: 05/28/2015 Inspection Type: Compliance Evaluation Standby Power Is. automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment: Laborato Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? Comment: Yes No. NA NE II 0 0 ❑ ® ❑ ❑ ❑ 1111000 ❑ ❑ ❑ II ® ❑ ❑ ❑ O ❑ ❑ ® ❑ ❑ ❑ Yes No NA NE ® ❑ ❑ ❑ ®. ❑ ❑ ❑ ® ❑ ❑ ❑ 1 ❑ ❑ ❑ ® ❑ ❑. ❑ ® . ❑ ❑ ❑ Disinfection -Liquid - Yes No NA NE Is there adequate reserve supply of disinfectant? ® ❑ ❑ 0 (Sodium Hypochlorite) Is pump feed system operational? ® 0 ❑ 0 Is bulk storage tank containment area adequate? (free of leaks/open drains) II 0 ❑ 0 Is the level of chlorine residual acceptable? ® 0 0 0 Is the contact chamber free of growth, or sludge buildup? I 0 ❑ 0 Is there chlorine residual prior to de -chlorination? • ❑ 0 ❑. Comment: Influent Sampling Yes No NA NE # Is composite sampling flow proportional? ❑ 0 II 0 Is sample collected above side streams? ■ 0 0 0 Is proper volume collected? ® 0 0 ❑ Is the tubing clean? ■ ❑ ❑ ❑ Page# 7 Permit: NC0020656 Owner - Facility: Leith Creek VVWTP Inspection Date: 05/28/2015 Inspection Type: Compliance Evaluation Influent Sampling # Is proper temperature set for sample storage (kept at Tess than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Comment: Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume, collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Upstream / Downstream Sampling Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? Comment: Yes No NA NE ® ❑ 0 ❑ 0 ❑.❑ Yes No NA NE ® .❑ ❑ ❑ ® ❑ ❑ ❑ ❑ ❑ ❑ ❑.❑ II ❑ ❑ IN ❑ ❑ ❑ Yes No NA NE MOOD Page# Regional. inspectors' Checklist for Field P rameter Facility Name: Leith Creek WWTP Regional Plant Inspector: Mark Brantley NPDES #:NC0020656 Regional Inspector Contact #: 910-433-3327 Field Lab Certification #: Region: FRO Lab Contact :Ricky Odum Date: June 24, 2016 B. Check the paraaeter(s) performed at this site for reporting purposes. ei Total Residual Chlorine (TRC) [2 Temperature (TEMP) Specific Conductivity (SC) EpH Dissolved Oxygen (DO) ❑ Settleable Residue (SETT) BB. General Laboratory (note any exceptions in section XB Are instruments, meters, probes, photometric cells, etc. maintained in good condition? Yes ❑ No Are standards, reagents and consumables used within manufacturer expiration dates? [TRC gel standard is exempt.] 4 es ❑ No Date of sample collection* Time of sample collection* Sample collector's initials or signature Date of sample analysis* Time of sample analysis* Analyst initials or signature Sample location "Date and time of sample collection and analysis may be the same for in situ or on -site measurements. $ 1I.:-, [AHcPIB 1('i1e 1 brl'r o-.. ''}:, + :...: ..:t ..., .:._, ' �£,.,....' ?, Total Residual Chlorine meter make and model: Hach 2800. Is a check standard analyzed each day of use? gel standard Yes ❑ No What is the assigned/observed value of the daily check standard? Is a 5-point calibration verification performed? Note date of last verification: 2-12-15. Yes ❑ No Alternatively, does the lab construct a linear regression, using 5 standards, to calculate results? Note date of last calibration curve constructed: ❑ Yes ❑ No True values:. a pg/L ❑ mg/L _500_ _300_ _100_ _50_ _10_ Obtained values: ;pg/L ❑ mg/L _513_ _310_ _105_ _51_ _11_• What program are samples analyzed on? ULR Are results reported in proper units?. Check one: Qg pg/L ❑ mg/L E Yes ❑ No Are results reported between the facility's permit limit and the compliance limit of 50 pg/L? If value is less than the low standard, report as "<x", where x=low standard conc. Yes ❑ No Are samples analyzed within 15 minutes of collection? Yes ❑ No 4 pH meter make and model: YSI 60 Is the pH meter calibrated with at least 2 buffers per mfg's instructions each day of use? Note buffers used: E Yes ❑ No Is the pH meter calibration checked with an additional buffer each day of use? Note check buffer used: es ❑ No Does the check buffer read within ±0.1 S.U. of the known value? Yes ❑ No Are the following items documented: Meter calibration? Yes ❑ No Check buffer reading? Yes ❑ No Are samples analyzed within 15 minutes of collection? Lres ❑ No Are sample results reported to 0.1 pH units? es ❑ No p-. ..{fig pV What instrument(s) is used to measure temperature? Check all that apply: ❑ pH meter ❑ DO meter ❑ Conductivity meter ❑ Digital thermometer ❑ Glass thermometer . Is the instrument/thermometer calibration checked at least annually against a NIST traceable or NIST certified thermometer? ❑ Yes ❑ No Are temperature corrections (even if zero) posted on the instrument/thermometer? Yes ❑ No Are samples measured in situ or on -site? [REQUIRED - there is no holding time for temperature] ❑ Yes ❑ No Are sample results reported in degrees C? ❑ Yes . ❑ No ra--oive� O y e _, , .,. n..� _ r ..�v-- ,... ..-...-- ..f�=+-.i.. ...+ , ,.-. _�1..>.#r DQ meter make and model: YSI 550A Is the air calibration of the DO meter performed each day of use? El Yes ❑ No Are the following items documented: Meter calibration? Yes ❑ No Are samples analyzed within 15 minutes of collection? Yes ❑ No Arepresults reported in mg/L? Yes ❑ No � YI�Y :}' C®nW W6 IVG}S ...�1} 5, i { ...2 t } ,` trx 2: Conductivity meter make and model: ORION 3-STAR Is the meter calibrated daily according to the manufacturer's instructions? Note standard used (this is generally a one -point calibration): Yes ❑ No Is a daily check standard analyzed? Note value: g, es ❑ No Are the following items documented: Meter calibration? Yes ❑ No Are samples analyzed within 28 days of collection? Yes ❑ No Are results reported in Ifmhos/cm (some meters display equivalent pS/cm units)? Yes ❑ No y ]y{22}2ryp221 i 'Jtl[UY �, 0:'2}kW\ ,\: ,,t N.. h:).t: .,. .. A.:T,Y.P Z - } Y ti}<At '� ( r 3} `::, .rL. v ,d Does the laboratory have an Imhoff Cone in good condition? _ Yesn tp. Y{e s` Ytesl,= . o'p #o' +, o'� o i Is the sample settled for 1 hour? Is the sample agitated after 45 minutes? Are the following items documented: Volume of sample analyzed'? Note volume analyzed: = Ye`�. � Yves e .f Date and time of sample analysis (settling start time)? Time of a•itation after 45 minutes of settlin•? = Ytog 4Yrs;;_ ,� 1®.- div Sample analysis completion (settling end time)? Are samples analyzed within 48 hours of collection? Are results reported in ml/L? ryes • ®, tln �s ,ef fra1 {.o ® f hp ' �'r11�-pp fracit. ®1Y �li�� � 1�� ®{®i d��' Y s ad O,rm�>d� 1« � lla� yid➢G4$....1161-2$ t s r t ia. �G. �Cr,-� � .4..1... i `i.:F � FFti. i; }.. x y x t , i io11O a e r' o atacata r�' p ' ®- r ITN comma h�dsa� . . ,_. „ � Ve �4 N ... XL Addition.}1 comments: © Nothing major was noted during the inspection. It has been some time since a laboratory inspection was performed according to the facility staff. Please submit a copy of this completed form to the Laboratory Certification program at: DWQ Lab Certification, Chemistry Lab, Courier # 52-01-01 Electronic copies may be emailed to linda.chavis@ncdenr.gov. Revision 04/20/2012