Loading...
HomeMy WebLinkAboutWQ0042577_More Information (Requested)_20210813ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director NORTH CAROLINA Environmental Quality August 13, 2021 BRUCE PORTER AND MELANIE BETH BROWN -PORTER 2200 SHAW ROAD DURHAM, NORTH CAROLINA 27704 Subject: Application No. WQ0042577 Additional Information Request 2206 Shaw Rd. SFR Single -Family Residence Wastewater Irrigation System Durham County Dear Mr. and Mrs. Porter: Division of Water Resources' Central and Regional staff has reviewed the application package received June 4, 2021. However, additional information is required before the review may be completed. Please address the items on the attached pages no later than the close of business on September 13, 2021. Please be aware that you are responsible for meeting all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the Applicant's responsibility. In addition, any omissions made in responding to the outstanding items in Sections A through L, or failure to provide the additional information on or before the above requested date may result in your application being returned as incomplete. Please reference the subject application number when providing the requested information. All revised and/or additional documentation shall be signed, sealed and dated (where needed), with one electronic copy submitted to my attention at the email address below. If you have any questions regarding this request, please do not hesitate to contact me at (919) 707- 3661 or poorva.mokashi@ncdenr.gov. Thank you for your cooperation. Sincerely, DIocuSigned by. tA A167AEB7F4A546F... Poorva Mokashi, Engineer I Division of Water Resources cc: Raleigh Regional Office, Water Quality Regional Operations Section (Electronic Copy) Gary S. MacConnell, PE — MacConnell & Associates, PC (Electronic Copy) Permit Application File WQ0042577 £ D_E NORTH CAROLINA Department of Environmental Quality North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 919.707.9000 Mr. Bruce Porter and Mrs. Melanie Beth Brown -Porter August 13, 2021 Page 2 of 4 A. Cover Letter: 1. No comments B. Application Fee: 1. No comments C. Application: 1. No comments D. Existing permit: 1. Not applicable E. Property Ownership Documentation: 1. No comments F. Soil Evaluation: 1. Please specify the soil mapping units within each land application site to indicate whether it is WsB or WsE or if it is both and update the `Figure 4' [15A NCAC 02T .0604(b)(3)]. Please also specify on this map that the dominant soil series is White Store. The updated `Figure 4' should be signed, sealed and dated by a North Carolina Licensed Soil Scientist [15A NCAC 02T .0604(b)]. 2. The Raleigh Regional Office has recommended following changes to the 'Fill Application plan'. a. Clear and grub site by hand in such a manner as to minimize native soil loss and compaction. b. The provided plan indicates that "the existing ground surface should be lightly tilled to scarify the surface and should extend at least three (3) feet beyond the intended irrigation area." This area should be increased to extend at least five (5) feet beyond the proposed wetted area on all sides. c. The provided plan indicates that "the fill material should extend one (1) foot beyond the proposed disposal area. "The fill material should extend at least five (5) feet beyond the wetted area and blend into the natural contours of the area. d. Remove vegetation less than 8 inches in diameter from the disposal area. e. Avoid placing fill material under the drip line of any trees that are to be left within the disposal area to prevent tree death (an arborist can provide more guidance on tree protection). The application area Fill Plan will need to be modified to compensate for any area removed from the proposed application area for tree protection. Mr. Bruce Porter and Mrs. Melanie Beth Brown -Porter August 13, 2021 Page 3 of 4 G. Engineering Plans: 1. On sheet C-102, please add a statement that clearly specifies the depth of fill material as minimum 8 inches. Or the depth of fill should be such that it will provide one foot (12 inches) of vertical separation between any perched seasonal high water table and the ground surface [15A NCAC 02T .0605(q)]. H. Engineering Calculations: 1. According to Section I of the Instructions for `Form: SFRWWIS 06-16', please provide Friction/total dynamic head calculations and system curve analysis for each pump used [15A NCAC 02T .0604(c)(3)]. I. Site Map: 1. Please provide an enlarged version of the `overall site plan', sheet C-101. Please update the site map to indicate the soil mapping units on all disposal sites based on changes which will be made by the Lead Soils Scientist on the `Figure 4' [15A NCAC 02T .0604(d)(1)(B)]. Also ensure that the updated site plan has been signed, sealed and dated by a North Carolina licensed Professional Engineer and/or Professional Land Surveyor. J. Operation & Maintenance Plan: 1. No comments K. Additional Documentation: ➢ County Health Denial Letter: 1. Please provide a provide a written letter from the Durham County Health Department denying the site for all subsurface systems. [15A NCAC 02T .0604(g)] ➢ Floodway Regulation Compliance: 1. No comments > Operational Agreements: 1. No comments > Threatened or Endangered Aquatic Species Documentation: 1. No comments Mr. Bruce Porter and Mrs. Melanie Beth Brown -Porter August 13, 2021 Page 4 of 4 L. Recommendations (No response required): 1. Depth of dripline: It is mentioned in the Specifications, that driplines are typically placed at depths of 6-10 inches below the surface, which would be considered a subsurface disposal system, and is not permitted by the Non -Discharge branch. Hence the drip lines with emitters should be placed above -grade, and a written letter from County Health Department denying the site for all subsurface systems is required. [15A NCAC 02T .0604(g)]