Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0021813_Regional Office Historical File Pre 2018 (3)
pcW AE Michael F. Easley, Govemor PG _ William G. Ross Jr., Secretary 7 North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality September 7, 2004 Mr. William Cook, President Continental Communities/ Charlotte, LLC 150 East Broad Street, Suite 200 Columbus, Ohio 43215 Subject: Permit No. WQ0021813 Modification Continental Communities/ Charlotte, LLC Atkins Circle Wastewater Collection System Extension Mecklenburg County, North Carolina Dear Mr. Cook: In accordance with your application received on August 23, 2004, we are forwarding herewith Permit No. WQ0021813, dated September 7, 2004, to Continental Communities/ Charlotte, LLC for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, shall void Permit No. WQ0021813 issued April 21, 2004, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated. therein by reference. The modification includes the addition of 6 apartment units and a flow increase of 810 gallons per day. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Also note Permit Condition 12 regarding the variance for the proximity of gravity sewer to water main. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. NCOENR Mooresville Regional Office Internet http://h2o.enr.state.nc.us/ 919 N. Main Street, Mooresville, NC 28115 Telephone (704) 663-1699 .Fax (704) 663-6040 DENR Customer Service Center Telephone 1 877 623-6748 Mr. William Cook Page 2 September 7, 2004 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Continental Communities/ Charlotte, LLC for the discharge of 810 gallons per day of collected domestic wastewater (to serve 6 apartment units, with no additional line length, as part of the Atkins Circle project) into the Charlotte Mecklenburg Utilities' existing sewerage system, pursuant to the application received August 23, 2004; and the continued construction and operation of approximately 1,500 linear feet of 6-inch gravity sewer and 4,990 linear feet of 8-inch gravity sewer; an 87-gallon per minute pump station with duplex pumps, on -site audible and visual high water alarms, and a portable generator receptacle with telemetry; and approximately 1,705 linear feet of 4-inch force main to serve 562 apartment units as part of the Atkins Circle project; and the discharge of 75,870 gallons per day of collected domestic wastewater into Charlotte Mecklenburg Utilities' existing sewerage system, pursuant to the application received April 21, 2004, and all in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Charlotte - Mecklenburg Utilities' McAlpine Creek WVVTP (NPDES No. NC0024970) prior to being discharged into the receiving stream. This permit shall become voidable unless the agreement between Continental Communities/ Charlotte, LLC and Charlotte Mecklenburg Utilities for the collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Mecklenburg County Health Department Mecklenburg County Water Quality Program Mooresville Regional Office, Water Quality Section (W VTF Permit No. NC0024970) Jeffery Orsborn, GNA Design Associates, Inc. Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sew.er system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to NCDENR/ Water Quality, 919 North Main Street, Mooresville, NC 28115. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 28 .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 213 .0200 and 15A NCAC 2H .0500. 2 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733- 3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report,shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 12. A variance to 15A NCAC 2H .0219(i)(2)(ii) and the Gravity Sewer Minimum Design Criteria to allow for the installation of a gravity sewer line within the less than required 10-foot horizontal separation from the proposed water line. The sewer line shall be installed with a minimum vertical separation of 18 inches, with water over sewer. Permit issued this the 7th day of September, 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, ., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0021813 3 Fast Track Engineering Certification Permit No. WQ0021813 Modification September 7, 2004 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer fines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEERS CERTIFICATION ❑ Partial ❑ Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Atkins Circle, Mecklenburg County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 ATTENTION: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 0 LL Z z z 0 2 0 LL Z I AST TRAC1 APPI_IC A'TioN far GR,,V'ITY SEWERS. PUMP STATIONS, AND FORCE MAINS USE THE TAB KEY TO MOVE FROM FIELD TO FIELDI Application Number (ic be completed by DWQI 1„ lOvvner ta. Continental Communities/Charlotte* Ful6 Legal Name (company, municipality, HOA, uti �lity, etc,) ib. William H. Cook 0 Signing Official Name and Title (Please review lc. The legal entity who will own this system is: 0 Individual ❑ Federal ❑ Municipality ❑ State/County ❑ Private Partnership Ej Corpo ld, 150 E. Broad Street, Suite 200 ie Columbus Street Address Oh io State lh, 614/228-1362 Telephone 2. Project (Facility) Information, 2a. Atkins Circle Facsimile Brief Project Name (permit will refer to this name) Contact Person: Jeff Orsborn, Project Manager City ig 43215 Zip Code ....._ ...... 24. Mecklenburg County Where Project i Name and Affiliation of Someone Who Can Answer Questions About this Application 30, 704/373-1907 Phone Number 1 Project is 0 New odification (of an existing permit) 3c, ,j orsborn@gnades 'zed signing officialsl) n L J he gn. com Email If Modification Permit No.: WQOO2 1813 PAGE 3 specify): For modifications, attach a separate sheet clearly explaining the reason for the modification (i,e, adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in. B(7) and B(10-11) that has already been included in the original permit. 2, Owner is ❑ Public (skip to Item 8(3)) Private (go to ltem 2(a)) 2a, If private, applicant will be: 2b. It sold, facilities owned by a (must otitose ❑ Retaining Ownership (i.e. store, church, single office, etc,) or Leasing units (lots, townhomes, etc. - skip to Item 8(3)) 0 Selling units (lots, townhomes, etc, - go to Item B(2b)) CharlottemmWecklen urg LL Owner of Wastewater Treatment F 4a, McAlpine Creek WWTF Name of WWTF 5a, CMUD' _. 1,C1'iflD) TF) Treating Wastewater From This Project 44, f,IC0024970 .w���. ❑ Public Utility (Instruction III) ❑ Homeowner Assoc./Developer (Instruction IV) 8 7- Owner of Downstream Sewer ! Receiving Sewer Size The origin of this wastewater is (check all that apply): ❑ Residential Subdivision ❑ Car Wash Sa Apartments/Condominiums ❑ Institution ❑ Mobile Horne Park 0 Hospital 0 School ❑ Church ❑ Restaurant ❑ Nursing Home 0 Office 0 Other (specify)„ WWTF Permit No. Permit Number mof Downstream Sewer (if known) 7. Volume of wastewater to be ppirrst(ted in this project: 810 gallons per day B. if the permitted flow is zero, indicate why. 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected % Domestic/Commercial % Industrial Other (specify): FTA 02/03 - Rev, 20404 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 25' LU 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). 6 NT Units x 135 gpd = 810 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) - • - Size (inches) Gravity or Force Main Length (feet) (use the pull down menu) • . _ r- '• ^ Z ENTER TOTAL LINE LENGTH IN MILES I 0 I /— 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) < Location ID i i i , Power Reliability Option CC (self chosen - as shown on - Design Flow Operational Point I (1- dual line feed; 2- permanent generator w/ATS; 3- 0 • plans for cross-reference ll (MGD) GPM @ TDH _portable gsherator wIteleme_tly14-wet well_storaget . LL 1 • I i • Z 1 1 I -- i 11.1 CL 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? - • 1 D Yes E No If no, please reference the pertinent minimum design criteria or regulation and indicate why a • _1 variance is requested: variance previously approved in permit WQ0021813 'sUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 113. Have the following permits/certifications been submitted for approval? • Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes 0 No NIA Sedimentation and Erosion Control Plan? Stormwater? E Yes DNo 0 N/A El Yes CI No 0 N/A FTA 02/03 - Rev. 2 04/04 'FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1 Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality } Z regional office (see instructions for addresses) OR indicate the following: ! O • ❑ A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND ,U i ❑ A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability LL I option for any pump station near a Class C down slope waterbody. Location ID on Map L!) (self chosen - as shown on ' Name of Q•; map for cross-reference) Waterbody County _ P rev ously_Provide d See attached WSCA 10/99 Waterbody Stream Waterbody River Basin l Index Classification Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: f. SIGNING OFFICIAL NAME, attest that this application for PROJECT NAME has been reviewed by me and is accurate and complete to the best of my knowledge. l understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: in accordance with North Carolina General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil p_enalties up S25, 000 per violation. Sign ••'''Signature 2. Professional Engineer's Certification: 1 attest that this application for has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. i further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that i have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. ,Jeffery r._ flrsliorn Professional Engineer Name 2b. GNA Design A_ss_o__ciates , Irtc Engineering Firm c 428 E. Fourth.Street, Suite 408 Address —Marlon e -- 2d. 2e. NC_._. ,2f. 28202_._.._.. City State I Zip 2g. 704/373-1Q0.7 2h. 704/358-0766 '21. 1 Qrsborn@gnadesi gn 0.6m 1 Telephone i Facsimile - E-mail CAR i',J;i fie' .ti • • cL lC.�1(��! g'oy Seal, Signature & Date FTA 02/03 - Rev. 2 04/04 09/03/04 Permit Number WQ0021813 Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.williams Pertnitted Flow 810 Facility Permit Tracking Slip Status Project Type In review Major modification Version Permit Classification Individual Permit Contact Affiliation Facility Name Major/Minor Region Atkins Circle Minor Mooresville Location Address County Mecklenburg Facility Contact Affiliation Owner Owner Name Owner Type Continental Communities/Charlotte LCC Non-Govemment Owner Affiliation William Cook 150 E Broad St Columbus Dates/Events OH 43215 Scheduled Orig Issue App Received Draft Initiated Issuance 10/14/02 08/23/04 Public Notice Issue q f7 Jo4 Regulated Activities Requested/Received Events Apartment complex Wastewater collection Outfal! NULL Effective Expiration Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin August 18, 2004 N,C.D.E.N.R, Non -Discharge Permit. 919 N Main Street Mooresville, NC 28301 'ng Unit Re: Explanation of Modification to Permit WQ0021813 Atkins Circle To Whom It May Concern: I previously permitted the above referenced project in October 2002 and subsequently revised the permit in April 2004. The project is nearing completion, and the developer has made an additional revision to add a few more multi -family units. With this submittal, I request the above permit be modified to allow for the additional discharge of 810 gpd (6 units x 135 gpd) for a total discharge of 76,680 gpd (568 units x 135 gpd). Please find enclosed two application forms, two revised flow acceptance letters from Charlotte -Mecklenburg Utilities Department, and the required application fee. If any further information is required, please don't hesitate to contact me. Sincerely, GNA SJN ASSOCIATES, INC. JeferC. Orsborn, PE Project Manager JCO/It add\proj1517751corresp©ndence1081804LT-NCDENR-SEWER.wpd TerraServer Image Courtesy of the USGS Page 1 of I Send 're POnter Back To TerraServek Change to 11)(17 Print Size ).4 ' 4 : 211G8 17 km S of Charkkbe, Niorth Carotin i „, it 1011) ,..)) * 1 4 i 1/44 #4 or . 4*" OL tort 1„ 5Km 0° Show Grid. Lines ChalIge to Landscape nn S tes 01)111 1.988 44,444.4, , r* ,,,, , 4 „, ,,,, . , • , , ' , ..,, It. ' 1, Z51°11i image courtesy of the U,S. Geotogicai Survey ig) 2004 Microsoft Corporation. Terms of Use Privacy Statement http://terraserver,homeadvisor.msn.com/printi mage.aspx?T-28z S 1 2&X-6424k Y-48 50&Z—... 8/20/04 CHARLOTTE. CHARLOTTE-MECKLENBURG UTILITIES August 18, 2004 Mr. Jeffery Orsborn GNA Design Associates, Inc. 428 East Fourth Street Suite 408 Charlotte, NC 28202 SUBJECT: WATER AND SANITARY SEWER FLOW ACCEPTANCE ATKINS CIRCLE APARTMENTS TAX PARCEL# 223.231-40, 223-23141, 223-231-03 C-MU# 600-04-511 Dear Mr. Orsborn: in response to your request, a flow acceptance study of the subject site has been completed and it has been determined that the discharge from this project does not transmit through areas of SSO concern by the NCDENR, Division of Water Quality. Please see attached map. Upon completion and acceptance of all necessary sewer lines, Charlotte -Mecklenburg Utilities (C-MU) agrees to accept the sewage flow of 76,680 gallons per day (568 units x 135 gpd/unit with 4-inch pool connection) from this project for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works; which is contingent upon final acceptance and issuance of a discharge permit from the appropriate local, State, or Federal Agency, whichever might have control. Upon completion and acceptance of all necessary water mains, C-MU agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, dated January 2009, (WSMP # 00- ©0251 & PWS ID # 0160010), on file with the Public Water Supply Section of NCDENR. However, C-MU cannot guarantee a constant pressure or quality of flow. This agreement is also contingent upon approval by the Division of Environment, Health, and Natural Resources, C-MU does not expect any of the above conditions preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the C-MU system is accepted on a first come, first served basis. If you have any questions, please contact me at (704) 391-5129. Sincerely, CHARLOTTE-MECKLENBURG UTILITIES Barbara Gross Engineering Assistant CHARLOTTE-MECKLENBURG UTILITIES Engineering Division • New Services Section www,cmutilities.c©rn 5100 Brookshire Boulevard Charlotte, NC 28216 Ph: 704/399-2221 Fax: 704/393-2219 Lgyy�ul: ®Mount and Basin �1Lan Creek Basin ©Id Dowd RoadlPaw Creek Basin MIPlott Road Area DLansbury Court Area. erArko Rck9e SITE CMU# 60004-511