Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0041563_Regional Office Historical File Pre 2018
State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION .APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: e'V L ft)6 (to he completed by DVv'tt,) All items must be completed or the applieation will be.returned APPLICANT INFORMATION: 1. Applicant's name: East, Lincoln Fire Department (company, ttttmicipality, l-IOA, utility, etc,. [1 General Partnership © Privately -Owned Public utility Li Federal [1] State.a'County [j Municipal 0 Other 2. Applicant type: [1 Individual [1 Corporation Signature authority's name: Janes Martin per Title: Chairman 4. Applicant's mailing address: 406 S. Pilot Knob Road City: Stanley State: NC Zip: 28 164-,_ 5. Applicant's contact information: Phone number: (1ail t'9j 170 / 'nail Address:, aj IL PROJECT INFORMATION:. 1.. Project name: East Lincoln Fire Departm.ertt " . Application/Project: status: ® Proposed (New Permit) © Existing Permit/Project If a modification, provide the existing permit number: WQ€O0 and issued date: If new construction but part of a rn.aster plan, provide the existing permit number: WQ00 3. County where project is located: Lincoln 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.4557' Longitude: -8 E0437' 5. Parcel I.D (if applicable): 50192 (or Parcel ID to closest downstream sewer) M. CONSULTANT INFORMATION: I. Professional Engineer: Dan Brewer P F,. License Number: 17582 Firm: ESP Associates,_Inc, Mailing address: 20484 Chartwell Center Dr, Suite City: Cornelius. State: NC Zip: 28031- Phone number: (704) 990-9428 Email Address: dbre IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Killian Creek WWTP Permit Number: NC 0088722 Owner Name: Lincoln County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s): WQ Downstream (Receivin.g) Sewer Size: 8 inch S (m,.oIlec.,11 911 ti:.f.1.1,..'Mi ir_\u it h.j )1wq 4p?p1_ra sly ,'M: WQCS00149 Owner Name(s): Lincoln County RECEIVE EIVEDWCDE:i P D61a°i WQROS RM: FTA 04-16 Page I of 5 Vi. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Ccrtificat Yes ❑No 2., Ifthe Applicant is a Developer of lots to be soldhas a P_? ,v e lol;?ef s ❑ Yes ❑No EN/A If the Applicant is a l l :}lv,/y 4. Origin of ater: (check all that apply): ❑ Residential. Owned ❑ Residential Leased. ❑ School J preschool / day care ❑ Food and drink facilities ❑ Businesses / offices / factories 5. Nature of wastewater : 100 % f: of Public Convenience and Necessity been attached? v is ail }fit^t` 9 � ��t 11 t 9P 1: i3t:^:4}`l been attx ched?. N/A El Yes ❑No ®N/A ❑ Retail (stores, centers, malls) © Retail with food preparation/service ❑ Medical / dental / veterinary facilities Church Nursing. Nome mestie/Conimercial % Industrial (time_ �ls there a Pretrea eduction been approved under arovide a copv of flow reduction n tproval 7. Summarize wastewater generated by project: Establishment Type (see 021.01 14(f, Fire or Rescue with on -site staff 50 g< /e Commercial ent Program in effect? 4{ ? ❑ Yes Design Flow '°� Person per shift gal/ gal/ cmul_Ll. OR I been attached? ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool ./Clubhouse ❑ Swimming Pool/Filter Backwash Other (Explain in .Attachment) No No. of Units Flow 5 250 GPD gal/ gal/ gala'' GPD GPI) GPD GPD GPD Total 250 GPD a See 1 /'\ Pit AC 021. 411 1 10 _Ld) 0, 1) �g i�'1(2) for caveats to wastewater design flow rates i.e., minimum flow per dwelling, proposed unknown non-residential development uses; public access facilities located near high publicuse areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in i.i,Sk..4m'A.-- ). b Per 15A NCAC 0217.01 I4(c), design flow rates for establish. eats not identified [in table rcl determined using avail.ablc flow data, water using fixtures, occupancy or operation patterns Wastewater generated by project: 250 GPD (per Do not include future flows or previously permitted ahocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: (_f Rehabilitation or replacement of existing sewer with no new flow expected Ej Other (Explain): shall be nd other measured data. FORM: FTA 04-16 Page V11. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - fly "I" 1. Summarize gravity sewer to be permitted: Material PVC: DIP Section II & .Ill of the MDC for Permitting, of Gravity Sewers contains infonraat Section 111 contains .information related to minimum slopes for gravity sewers) ▪ Oversizing lines to meet minimum slope requirement is not. allowed and a violation of the MUC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) —112T fldtl5 & 11(;)Cm (Punk COMPLETE FOR EACW PUMP STATION INCLUDED IN TFIIS_PRO,IECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: 3.. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDIi) 5. Summarize the force main to he permitted (for this Pump Station): Size (inches) .4100.0 Length (feet) esign criteria Power reliability in accordance with 1 5 \ El Standby power source or pump with automatic activation and telemetry 15A NCAC 02T ,0305(hX1)(f3)= • Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day • Must be permanent to facility O if the pump station has an average daily flow less than 15,000 gallons per day: D Portable power source with manual activation, quick -connection receptacle and telemetry - t5'A NCAC 02T .0305(h)(1)(C) ur 0 Portable pumping unit with plugged emergency pump connection and telemetry - 1. 5A NCAC 02T .0 305(h)(1)(C): 1t. shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. tithe portable power source or pump is dedicated to r.ultiple pump stations, an evaluation of all the pump statiotn.s' storage capacities and the rotation schedule of the portable power source or pump, including travel titnefr mes, shall be provided in the case of a multiple station power outage. FORM: F`TA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A. NCAC 02T .0305(t)): 1. Does the project comply with all separations found in 1. im provideds stems; SA NCAC OZ°I'.t)305�coratarns minimum sep4►r°attons that shall. he for sewer Setback P Storm sewers rati other utilities rno't listed below (v Wafter mains verticater over sewer including in benched trenches Writer attains "horizontal) Reced water lines vertical - reciaitrae=d over sewer) Reclaimed water linesJlaorizontal - reclaimed over sewer) **Any private or public water supply source, including any wells, WS-I waters ofC 'lass 1 o Class 11 imou.nded reservoirs used as a source of drinking water **haters classified WS (except WS-I or WS-V), B, SA, ORW, HOW, or SB from normal high water "or tide elevation) and wetlands (see item IX.2) **Any other stream, lali ditches An buildindation An 'basement rnpoundment, or ground water lowering and surface drainage To slo e of ettnbankment or cuts of 2 feet or more vertical hei h Drainage systems and interce for drains An wirn.rnint pools Final earth rad.e vertical Stream clas If .noncompliance ,I contains alternatives where separations in (.�Y 1w s can be identified using the Divisions N, see Section X of this application Yes in Required 24 inches 8 inches I 0 feet inches 10 feet 5 feet 0 feet 1.0feet 5 feet annot be achieved. Does the project comply with separation requirements for wetlands? (50 feet of separation) © Yes • See the Division's draft separation requirements for situations where separation cannot be meet " No variance is required lithe alternative design criteria specified is utilized. in design and construction r As built documents should reference the location of areas effected Does the project con ply with setbacks found in the ➢ This would include Trout, Buffered Streams per basin rules per 1 AA ' `(.. Nt`,A,(. 213.0:.02 4. Does the project require coverage lauthori;tataon under a 404 Ntationw ide or individual permits. or 401 Water Quality Certifications? • information can he obtained from the Does project comply with Per .I 5 1 NC_AS 0' p (1 ¢) Lc.1+ been applied for, or have hee! sedimentation control plans, stormwater management plans, etc.). 'additional t-tennitsicertification 1, rlarcetly related environmental permits or certification applicatio obtained. Issuance of this permit is contingent on issuance of dep No No N/A Yes Li No ll N/A • Yes Yes ® Yes No �s are being prepared, have ndent permits (erosion and Does this project. include any sewer collection lanes that are deemed "high -priority"?" Per A NC !;' 1 ( 0 " "high -priority sewer" paeans "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. 0 Yes No Q N/A ➢ If yes include an attachment with details for each line, 'including type (aerial line, size, material, and location). High priority lines shall be inspected by the perm.ittee or its representative at least once every, onths and ins documented per I5A NCAC 02T.0403(a)(5) or the permitec's individual System -Wide Collection. permit. FORM; FTA 04-16 Page 4 of 5 CF I4TIFICA"I IONS} 1. Does the submitted system comply with 041d f,.ODfy(t tt.... 1,41t.. 1.,,, and the t: s to Yes DNo If No, complete and submit the Variance/Alternative Design Request application (VA DC 10-14) and supporting documents for review, Ataproval of the request is re aired rior to submittal of the Fast Track A licat:ion and Professiona Appl icaticrrt d_ocume attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my .knowledge. 1 further attestthat to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers ('latest version), and the Minimum Design Criteria for the Fast -Track Perm,ittung of Pump Stations and Force Mains (latest version). Although other professionals may have developed. certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215,613, any person who knowingly makes any false statement,. representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may lnc lude a fine not to exceed $1.0,000, as well as civil penalties up to $25,000 per violation, North Carolina Professional Engineer's seal, signature, and date: Applicant's Certili per 15A NCAC 02T ,0106(h): Signatur Authority's narrte title from Application Item atte that this application for has been reviewed by the and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. l will make no claim against the Division of Water Resources should a condition of this permit be violated, 1 also understand that' if all required parts of this application package are not completed and that if all required supporting information and attachments arc not .included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes !al $ l , and E (7.2 II 5_6i3, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: -�j FORM: FTA 04-16 Page 5 of 5 Tuvia, Ori A From: Sent: To: Subject: Attachments: Charles S. King <cking@lincolncounty.org> Thursday, March 26, 2020 4:32 PM Tuvia, Ori A; Dan Brewer' RE: [External] RE: east Lincoln fire station FTSE-10-18_East Lincoln VFD.pdf ailuspicicumail Ori, Please see the up.dated page 1 that is attached. Please let me know if you need anything else. Thank You, Chuck King Engineering Associate Lincoln County Public Works 115 W. Main St. Lincolnton, NC 28092 Office: (704) 479-2065 Fax: (704) 736-8499 cking@lincolncounty.org From: Tuvia, Ori A [mailto:ori.tuvia@ncdenr.gov] Sent: Thursday, March 26, 2020 3:37 PM To: Charles S. King <cking@lincolncounty.org>; 'Dan Brewer' <dbrewer@espassociates.com> Subject: RE: [External] RE: east Lincoln fire station Chuck, I'm just looking to see somehow that the flow has been added to your allocated flows. Sincerely, Ori From: Charles S. King [mailto:clung@lincolncountv.org] Sent: Tuesday, March 24, 2020 2:56 PM To: 'Dan Brewer' <dbrewer@espassociates.com>; Tuvia, Ori A <ori.tuvia@ncdenr.gov> Subject: RE: [External] RE: east Lincoln fire station Extern l email D• no ;ciick links or open Ori, attachments unless j pu uspiciouaema►l as?an attadbment to 1 Division of Water Rcsource5 State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: East Lincoln Fire Department Project Name for which flow is being requested: East Lincoln Fire Department More than one FTSE maybe required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Killian Creek WWTP b. WWTP Facility Permit #: NC 0088722 c. WWTP facility's permitted flow All flows are in MGD 3.35 d. Estimated obligated flow not yet tributary to the WWTP 1.512010 e. WWTP facility's actual avg. flow 1.254 f. Total flow for this specific request 0.000250 g. Total actual and obligated flows to the facility 2.766 h. Percent of permitted flow used 82.57 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Station (Name or Number) Pump Station Permit No. 37 WQ0032852 Firm Capacity, * MGD 7.776 (A) Design Average Daily Flow** (Firm / pf), MGD 3.110 (B) (C) (D)=(B+C) (E)=(A-D) Approx. Current Avg. Daily Flow, MGD Obligated. Not Yet Tributary Daily Flow, MGD Total Current Flow Plus Obligated Available Flow Capacity*** 0.883 1.181541 2.064 1.0445459 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. Downstream Facility Name (Sewer): Lincoln County Sewer System Downstream Permit Number: WQCS00149 Page 1 of 6 FTSE 10-18 III. Certification Statement: I Donald V. Chamblee certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. c%9V1 Signing yyOfficial Signature �blce- -57 :f Title of Signing Official 3 (3 IQ -- Date Page 2 of 6 FTSE 10-18 PROPOSED SANITARY SEWER TO SERVE PROPOSED EAST LINCOLN FIRE DEPARTMENT PROJECT SITE EXIST, INGLESIDE FARM ROAD SUBDIVISION - PHASE 5 - 8" GRAVITY SSWR PIPE & MANHOLES EXIST. NGLESIDE FARM ROAD SUBDIVISION - PHASE 5 - 4" FORCEMAIN EXIST, INGLESIDE FAR ROAD SUBDIVISION - PHASE 5 - PUMP STATION f1 }Ii,IZON 200 II COUNTY OF LINCOLN, NORTH CAROLINA 1 1 5 WEST MAIN STREET, 24U FLOOR CITIZENS CENTER, LINCOLNTON, NORTH CAROLINA. 28092 DEPARTMENT OF PUBLIC WORKS PHONE (704) 736-8497 FAX (704) 736-8499 Vu1M1W.LNNCOL,NC©UNTY.ORG 3/1.2/2020 East Lincoln I irc [)epartnrent Attar: James Martin 406 S. Pilot Knob Rd, Stanley, NC 28164 R„ : East Lincoln Fire Department Mr. Martin, This letter is provided in response to your request, dated March 3, 2020, for flow a wastewater treatment infrastructure (the "System") for the Cast Lincoln Fire Department (the "P Lincoln County (the "County") has the actual average daily flow capacity at its Killian Creel. Wa.stew°at Treatment Plant to treat the domestic wastewater as requested, and does conditionaf/y grant approval for the Project, subject, however, to the terms and conditions 'below: WaROS mount of flow requested for the Project is for 1 lot with a total flow of Two Hundred and Fifty (250) gallons per day and 2, e .NCDEQ Permits, the receiving sewer treatment facilit Permit #NC 0'088722. The sewer collections fslcilit. #WQCS 00149; and Creek WWTP, he Lincoln County Sewer System, Permit 3. The County shall not he named as the Permittee on NCDEQ system appli make the application to NCDEQ in your own name m: and 4. Acceptance of the System and transferal of the Sys to the Co bjeet to the a. A complete final inspection and approval ol'the System by the County, and receipt of other applicable documentation request to by the County; and b. Approval of the System by NCDEQ, and proof provided to the County of a valid permit issued by NCDEQ with an.Authorization to Construct (Alt); and c. Initiating construction. of the Project within two years of the date of this conditional approval. You must notify the Lincoln County Public Works Department in wriiting when construction of the Project is initiated; and d. The County continuing to have actual average daily flow capacity to treat the domestic wastewater as requested at the time all other conditions precedent have been satisfied. This acceptance and the above. terms and conditions an with all of the above terms and cond of flow shall only be effective upon your compliance wwithl all of . ou.nty providing an acknowledgmentthatyou have complied Included in this mailing is the Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE — 04/16) with the County's portion completed. If you have any questions, please do not hesitate to call me at 704-736-8497. Sincerely, Chuck King Engineering Associate Cc: File ) ESP NCDEQ/DWR Water Quality Section — Wastewater Branch PERCS UNIT 1617 Mail Service Center Raleigh, NC 27699-1636 SUBJECT: East Lincoln Fire Department Application for Sewer Extension Lincoln County, NC Ladies and Gentlemen, January 8, 2020 ESP Associates has prepared the attached Fast -Track Application for Gravity Sewer and Force Main. Included in the application is listed below Fast -Track Sewer System Extension Application (FTA 04-16) with documentation A check for the application fee in the amount of $480 Flow Tracking/Acceptance for Sewer Extension Application (FTSE 10-1.8) Site Maps Insummary, the project involves proposed 8-inch gravity sanitary sewer to serve a proposed emergency services facility. The proposed sewer will discharge into the existing sewer stub on. Ingleside Farm Road Subdivision. — Phase 5, ultimately discharging into the existing pump station. 'The proposed flow for the project is 250 gpd. Please do not hesitate to contact me if you have any questions or comments. Sincerely, ESP Associates, Inc. r Dan Brewer, P.I. Senior Project Manager January 8, 2020 NCDEQ/DWR Water Quality Section — Wastewater Branch PERCS UNIT 1617 Mail Service Center Raleigh, NC 27699-1636 SUBJECT: East Lincoln Fire Department Application for Sewer Extension Lincoln County, NC Ladies and Gentlemen, ESP Associates has prepared the attached Fast -Track Application for Gravity Sewer and Force Main. Included in the application is listed below O Fast -Track Sewer System Extension Application (PTA 04-16) with documentation • A check for the application fee in the amount of $480 o FIow Tracking/Acceptance for Sewer Extension Application (FTSE 10-18) A Site Maps In summary, the project involves proposed 8-inch gravity sanitary sewer to serve a proposed emergency services facility. The proposed sewer will discharge into the existing sewer stub on Ingleside Farm Road Subdivision — Phase 5, ultimately discharging into the existing pump station. The proposed flow for the project is 250 gpd. Please do not hesitate to contact me if you have any questions or comments. Sincerely, ESP Associates, Inc. Dan Brewer, P.E. Senior Project Manager 20481 {'F irP rvl) f ;'11irr 13riro Suiiv 1) • C'trrzaliu,, \C 2ti(:1 i 1.R41).960.73 17 • 70-1.99{i =flvu • 1t < i i)d.58 1, 1130 wwv...espa XSt7i i 1r•S...1141i