Loading...
HomeMy WebLinkAboutWQ0040155_Regional Office Historical File Pre 2018 (2)ROY COOPER MICHAEL S. REGAN Svvrear LINDA CULPEPPER October 2, 2018 Brian Mahoney, Manager Prestige Corporate Development, LLC 2100 Torrence Chapel Road Suite 100 Cornelius, NC 28031 Subject: Perm it No. WQ0040155 Prestige Corporate Development, LLC Rivercross Apartments Wastewater Collection System Extension 1,11 Lincoln County Dear Mr, Mahoney: In accordance with your application received July '13, 2018, and additional information received October 2, 2018„ we are forwarding herewith Permit No, WQ00401.55 dated October 2, 201.8 to Prestige Corporate Development, LLC (Permittee) for the construction and operation upon certification ofthe subject wastewater collection system extension. This permit shall he effective from .the date of issuance until rescinded and shall be subjectto the conditions and, limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §14,3-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina-licen.sed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatoty hearing upon kv r nen. request within 30 days .fol lowing receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and tiled with the Office of Administrative Hearings, 6714 Mail Service Center, Raleig.h., NC 27699-671.4, Unless such demands are made, this permit shall be final and binding. Su e or Noah iohn, rovironmental 2uII Wainr It nisi:nil-nes Water Quality Ringional (.3pol:ikons Nifooreiwillo Regional Office1610 East Center Avningn. Stine .301 Moninsnil le, 'North Canolina 281 I 5 704 663 li699 11,41,14, Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first. knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur, Part li of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control, [G.S. 143- 215,1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State, [I5A NC.AC 02T.0108(b)j 7. -Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form, A complete certification is one where the form is fully executed and the supporting documents are provid.ed as applicable. Any ‘vastewater .flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the .form is fully executed and the supporting documents are provided a.s applicable. Supporting. documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CI) or DVI) disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, 'pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump ,cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stationsstorage capacities and the rotation schedule of the portable power source or pump, include travel timefrannes, shall be provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form„ Prior to Certification (Final or Partial). 'Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 1.0% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the lvlinimurn Design Criteria will be reviewed on a ease -by -case basis and each on. its own merit, Please note that variances to the Minimum Design Criteria should be requested and. approved during the permitting process prior to construction. After -construction requests are Page 6 of 8 discouraged.by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested. from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity"Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes § 143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page 7 of 8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: PRESTIGE CORPORATE DEVELOPMENT, LLC PERMIT #: WQ0040155 PROJECT: RIVERCROSS APARTMENTS ISSUE DATE: OCTOBER 2, 2018 This project shall not be considered complete nor allowed to operate in accordance with standard Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Regional Supervisor, Water Quality Regional Operations Section at the address noted in the page footer. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received by the Division. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permit -tee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (El periodically, fl weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1. 2000, as applicable; and other supporting rnaterials. North Carolina Professional Engineer's Seal w/signature & date: El Final L Partial (include description) Certification Comments/Qualifiers (attach if necessary): NC DWR Water Quality Regional Operations Section 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Mooresville Regional Office Phone: (704) 663-1699 FAX: (704)-633-6040 STATE OF NORTH CAROLINA COUNTY OF L,4'(*GL Permit No. le)� D04-0 •S DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT' made pursuant to G.S. 143-215.1 (di) and entered into this day of ��y, ► �x ; fr`- j-;,._,:by and between the North Carolina Environmental Management Commission, an ti _cncy dike State of North Carolina, hereinafter known as the COMMISSION; and 47PF P S`{I, �'' S 1L- , a corporation/general partnership. rcgistcred/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSBTH: 1. The DEVELOPER which It is recltt as e-, " "u' -O is the owner of the certain lands Tying in "lil: County, upon nd ►will creel yellin [nits and outer improvements, said development to beknown LA) 'f 0 � U<ri `ro :!'�� ` (hereinafter the Development). 2, The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater Treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on sold lands. • 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, mauilain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing ofa Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General.Statutcs. 5. The DEVELOPER has caused to be formed or ill se t be forme at the time of filing of the Declaration, the (Unit-Ownrs A essociatlon��/'"e- D//.,frrA.t" !` (hereinafter Association), a non=profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide fiends for such operation, maintenance, re -construction anclrepair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the putties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: I. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, find the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER' successor. FORM: DEV 11-17 Page 1 of2 FOR -THE -ENVIRONMENTAL MANAGEMENT COMMISSiSQN ilfijitula Culpepi interim Director, Division of Water Resources 24171---Piegite (Date) 41. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be plpperly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority fot' expenditures by the Association except for Federal, State, and local taxes and insurance, 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of llte common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fiend shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fiord are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into saki governmental system, and seta[l convey or transfer as much of the Disposal System and such accessary casements as the governmental unit ntayrequirc as condition of accepting the Developments wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person corporation or other entity acceptable to and approved by the COMMISSION by the issuance of [permit. 9. • The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ics) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto out the day and year written as indicated h of the pnllies named below: gal0. v u. Nam 13 ( ignature) Print tune and Title FORM: DEV 11-17 Pngc 2 of -434 t''''',-116•00100T,,,,, DIvIslort of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources ISA NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: led by MR.) All Items must be completed or the application will be returned L APPLICANT INFORMATION: I. Applicant's name: Prestige Corporate Development LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: El Individual Ii Corporation El General Partnership El Privately -Owned Public Utility ate/County Li Municipal El Other El Federal 3. Signal. re uthority's name: per 15A NCAC 02.T .0106(b) Title: 4. Applicant's mailing address: 21000 Torrence Chapel Road: Suite 100 City: Cornelius Slate: NC Zip: 28031. 5. Applicant's contact information: Phone number: (704) 607-5059 Email Address: steve@pcdllc.net IL PROJECT INFORMATION: I. Project name: Rivercross \partmen 2. Application/Project status: 6a) RECEIVEDINCOS NR1DWR R MOO k ESVI L LE REGIONAL OFFICE posed (New Permit) Ei Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Lincoln 4. Approximate Coordinates (Decimal Degrees): Latitude: 34,467997Longitude: -130.995463' 5. Parcel ID (if applicable): 4603519 04 (or Parcel ID to closest downstream sewer) IIL CONSULTANT INFORMATION: I. Professional Engineer: F3arry Fay License Number: 33046 Firm: American Engineering Associates Mailing address: 8008 Corporate Center Drive; Suite 110 City: Charlotte State: NC Zip: 28226- Phone number: (704)375-2438 Email Address: bfav • axon) IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Killian Creek WWTP Permit Number: NC0088722 Owner Name: Lincoln County V. RECEIVING DOWNSTREAM SEWER INFORMATION (ir different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 8 inch S °stem Wide Collect n S "a licable WQCS00149 Owner Name(s): Lincoln County FORM: FTA 04-16. Page 1 of 5 VI. GENERAL REQUIREMENTS If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No N/A If the Applicant is a Developer of lots to be sold, has a'Developer's Operational Agreement (FO Ztt is DEV been attached? LI Yes ❑No iN/A If the Applicant is a Home/Property Owners' A.' ocaation, has an Operational A Teen nHOAj been attached? ® Yes ❑No ❑N/A 4. Origin of wastewater: (check all that Residential Owned Residential Leased ❑ School / preschool /day care ❑ Food and drink facilities ❑ Businesses / offices / factories Nature of waste a 10 pply): ❑ Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental 1 veterinary facilities ❑ Church Nursing Home Domestic/Commet % Commercial % Industrial (See 15A NCAC ii?"t' .0103(201) >1s there a Pretreatment Program in effect'? 6. Has a flow reduction been approved under 15A NCAC 02T .011 -`l? ❑ Yes Ifyes, provide a copy of flow reduction approval letter 7, Summarize wastewater generated by project: Establishment Type (see 02T.01 I4(f)) Apartment Building 1 or 2 bedrooms Apartment Building 3 bedroom Daily Design. Flow e.b 0 Car Wash Lj Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming PoolF'Filter Backwash Other (Explain in Attachment) Yes No No. of Units Flow 160 gal/day 189 30,240 GPD 240 gal/day 42. 10,080 GPD Amenity Center 400 gal/day gal/ 400 GPD GPD gal/ GPD gal/ Total GPD 40,720 GPD a See NCAC 02T .0114(h). (dl, (e){'1) and {c)(2.) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in (:.i.S. 42A-4), b Per 15:A. NCAC 02T .0114(c), design flow rates for establishments not identified [in table I A \i AC C)?i",01 I4] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, Wastewater generated by project: 40,720 GPD (per 15A NCAC 02T ,0114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Purnp Station or Gravity Sewer where flow will be per ❑ Flow has already been allocated in Permit Number: Rehabilitation or replacement of existing sewer with no new flow expected 0 Other (Explain): d other measured data, d in subsequent permits that connect to this line 40: FORM: FTA 04-1.6 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T..03I15 MDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) 8 1937 pvc Y Section 11 111 of the 1vIDC for Pennittitg of Gravity Sewers contains information related to design Section 111 contains information related to minimum slopes for gravity sewer(s) r Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII, PUMP STATION DESIGN CRITERIA (If Applicable)-- 02T .0305 & MDC (Purnn Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PRO ECT 1. Pump station number or name:: Approximate Coordinates (Decimal Degrees): Latitude: , �° Longitude:- 3, Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TM) 5. Summarize the force main to be permitted (for this Pump Station): 6. Power reliability in accordance with El Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(hl)(B)1 A Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day • Must be permanent to facility Or if the pump station has an average daily Clow less than 15,000 gallons per day: © Portable power source with manual activation, quick -connection receptacle and tletttetry 15A NCAC 02T .0305(h�)(I)(C) or O Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(L)(C) > It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. 'r If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timefrarnes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 X. SETBACKS & SEPARATIONS — (02B .0200 & ISA NCAC 02T .0305(0): 1. Does the project comply with all separations found in 15A NCAC 02T .o305m & (g) :',•• 15A NCAC 02T,0305 t) contains minimum separations that shall be provided for sewe Yes DNo Setback Parameter* Separatkrn Required Storm sewers and other utilities not listed below (vertical) Water mains (vertical -water over sewer including in benchedtrenches) Water mains (horizontal) Reclaimed water lines (vertical - reclaimed over sewer) Reclaimed water lines (horizontal - reclaimed over sewer) **Any private or public water supply source, including any wells, WS-I waters of Class 1 or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, IIQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation An basement Top slope of embankment or cuts of 2 feet o more v ight Drainage systems and interceptor drains An swimming • ools Final earth grade (vertical) 24 inches 18 inches 10 feet 18 inches 2 feet 5 feet 10 feet 10 feet 5 feet 10 feet 36 inches ",•. 15A NCAC 02T.0305(0 contains alternatives where separations in 0210305(n cannot be achieved. • **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage • If noncompliance with 02T.0305see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) Yes 0 No 0 N/A See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction 1- As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin ruleper l5A NCAC 02B ,0200"?. Yes 0 No El N/A This would include Trout Buffered Streams per .15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? ▪ Information can be obtained from the 401 & Buffer Permitting Branch Yes No 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? Yes El No Pcr 1,5A NCAC 02'.1.0;05(c)(6j, directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per I5A NCAC 02E0402, -high-priority sewer" means -any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. El Yes 4No N/A • If yes, include an attachment with details for each line, including type (aerial (ine, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02'1%0403(2)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I5A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations -tMndatetJ. and the Gravity Sewer Minimum Desieri Criteria (latest version) as applicable? Yes DNo TIN°, complete and submit the Variance/Alternative Design Request application (V A DC 10-14) arid supporting documents for review, Approval of the request is required prior to submittal of the Fast Track Application and supporting documents, 2. Professional Engineer's Certification: attest that this application for Prof on Item 111.1. has been reviewed by rne and is accurate, c:omplete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast-Trac.k Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE — in accordance with General Statutes 143-215.6A and I43-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guL of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per A NCAC 02T .0106(b): th rity's narie & titte from Application Item 1.3. nest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from This non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. 1 will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incornplete. NOTE — In accordance with General Statutes I43-215,6A and I 43-2I5.6B. any person who knowingly makes any false statement, reprcsentatiQnir certification in any application pack e shall be guilty of a Class 2 misdemeanor, which may include a fine not to Acepd $lO,Oj0as well as civil penalties up to S25,000 per viotation. Signature: Date: FORM: ETA 04-16 Page 5 of 5 ROY COOPER f 0, 01 ICY!' MICHAEI.. S. REGAN seocrwy S. JAY ZIMMERMAN i)u ,,P February 1, 2017 Chris Henderson Engineering Associate Lincoln County Public Works 115 West Main Street Lincolnton, NC 28092 Subject: Killian Creek WWTP, NPDES # NC0088722 Residential Flow Reduction Lincoln County Dear Mr. Henderson: On January 29, 2007 the Division of Water Quality (now Division of Water Resources) granted a flow reduction for residential flow to Middle Forney Creek WWTP (NC0074012). Middle Forney Creek has been decommissioned and the NPDES permit rescinded. The flow previously being treated at Middle Forney Creek WWTP is now being treated at Killian Creek WWTP. All areas currently served by Killian Creek WWTP and conveyed through pump stations # 15 and # 37 were included in the analysis done for the flow reduction granted in 2007. Based upon the data provided by the County for the 2007 flow reduction, the Division of Water Resources hereby approves the use of 80 GPD per residential bedroom, with a minimum of 160 gpd for one and two bedroom units in all applicable non -discharge permit applications to Killian Creek WWTP (NC0088722). Flow shall be incremented by 80 gpd for each bedroom above two.. Regardless of the adjusted design daily wastewater flow rate, at no time shall the wastewater flows exceed the effluent limits defined in the NPDES permit for the treatment facility of exceed the capacity of the sewers downstream of nay new sewer extensions or service connection(s). The granting of this flow reduction does not prohibit the Division from reopening, revoking, reissuing and /or modifying the flow reduction as allowed by the laws, rules, and regulation contained in 15A NCAC 02T, NCGS 143-215.1, or as needed to address changed in State and/or Federal regulations with respect to wastewater collection systems, protection of surface waters and/or wastewater treatment. Nr, hin : rnp.' res • . State or North Carolina 0 Environmental Quality 1617 Mail Service Center 1 Raleigh, North Carolina 27699-1617 919-707-9000 If you have any questions, please contact me at (91.9) 807-6383, or via email at deborah. ore ncdenrrgov. Sincerely, for S. Jay Zimmerman Director, Division of Water Resources by Deborah Gore, Supervisor Pretreatment, Emergency Response and Collection Systems Branch Cc: Mooresville Regional Office, Water Quality Regional Operations Central Files: NC0088722 PERCS (electronic copy) State of North Carolina Department of Environmental Quality Division of Water Resources Division of 4Yxter Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation; Prestige Corporate Development, LLC Project Name for which flow is being requested: Rivercross Apartments More than one FTSE may be required for a single project if the owner of the WWTP is no( responsible for ctll pump stations along the route of the proposed wastewater low, 1. Complete this section only if you are the owner of the w a. WWTP Facility Name: Killian Creek WWTP b. WWTP Facility Permit #: NC0088722 c. WWTP facility's permitted flow ater plant. Alt flows are in MGD 3.35 d. Estimated obligated flow not yet tributary to the WWTP 1.55 e. WWTP facility's actual avg, flow f, Total flow for this specific request. g. Total actual and obligated flows to the facility h. Percent of permitted flow used. 1.133 0,040 2.723 81.28% Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow, List pump stations located between the project con ne ction point and the WWTP: (A) (B) (C) (D)=(B+C) ()=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / p), Daily Flow, Daily Flow, Obligated. Available Number) MGD MGD MGD MGD Flow Capacity*** #15B L856 0.742 0.000 0.215 0.215 0..527 * The Firm Capacity of any pump station is defined as the maxirnun► pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pig not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < t}. Downstream Facility Name (Sewer): Lincoln County Sewer System Downstream. Permit Number: WQCS00149 Page 1 of 6 FTSE 04- l6 III. Certification Statement: I Donald V. Chamblee certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project. has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normalcircumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using, the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment adden.duins for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Vicki Signarure Dale Page 2 of6 FTSE 04-16 • • File an Annual Report/Amend an Annual Report • Upload a PDF Filing • Order a Document Online • Add Entity to My Email Notification List • View Filings • Print an Amended a Annual Report form • Print a Pre - Populated Annual Report form Limited Liability Company Legal Name Prestige Corporate Development, LLC Information Sosld: 1630481 Status: Current -Active Annual Report Status: Current Citizenship: Domestic Date Formed: 10/12/2017 Registered Agent: Mahoney, Brian Addresses Mailing Principal Office 21000 Torrence Chapel Rd Ste 100 21000 Torrence Chapel Rd Ste 100 Cornelius, NC 28031 Cornelius, NC 28031 Reg Office Reg Mailing 21000 Torrence Chapel Rd Ste 100 21000 Torrence Chapel Rd Ste 100 Cornelius, NC 28031 Cornelius, NC 28031 Company Officials All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. Secretary Managing Member Patti -Lee D'Ausilio 21000 Torrence Chapel Rd Ste 100 Cornelius NC 28031 Brian Mahoney 21000 Torrence Chapel Rd Ste 100 Cornelius NC 28031 COUNTY OF LINCOLN, NORTH CAROLINA 1 1 5 WEST MAIN STREET, 2ND FLOOR CITIZENS CENTER, LINCOLNTON, NORTH CAROLINA 28092 DEPARTMENT OF PUBLIC WORKS PHONE (704) 736-8497 FAX (704) 736-8499 WWW. LINCOLN COU NTY.ORG June 15, 2018 Prestige Corporate Development, LLC Attn: Brian Mahoney 21000 Torrence Chapel Road, Suite 100 Cornelius, NC 28031 RE: Rivercross Apartments Mr. Mahoney, This letter is provided in response to your request, dated May 21, 2018, for flow acceptance of the wastewater treatment infrastructure (the "System") for the Rivercross Apartments Development (the "Project"). LincoIn County (the "County") has the actual average daily flow capacity at its Killian Creek Wastewater Treatment Plant to treat the domestic wastewater as requested, and does conditionally grant approval for the Project, subject, however, to the terms and conditions below: 1. The amount of flow requested for the Project is for 228 Units with a total flow of 55,120 gallons per day of additional flow at the NCDENR approved reduced flow rate of 240 gallons per day per home into LS-15; and 2. For the NCDEQ Permits, the receiving sewer treatment facility is the Killian Creek WWTP, Permit #NC 0088722. The sewer collections facility is the East Lincoln County Water and Sewer District, Permit #WQCS 00149; and 3. The County shall not be named as the Permittee on NCDENQ system applications. You must make the application to NCDEQ in your own name for the System; and 4. Acceptance of the System and transferal of the System to the County is subject to the following: a. A complete final inspection and approval of the System by the County, and receipt of other applicable documentation requested by the County; and b. Approval of the System by NCDEQ, and proof provided to the County of a valid permit issued by NCDEQ with an Authorization to Construct (ATC); and c. Initiating construction of the Project within two years of the date of this conditional approval. You must notify the Lincoln County Public Works Department in writing when construction of the Project is initiated; and d. The County continuing to have actual average daily flow capacity to treat the domestic wastewater as requested at the time all other conditions precedent have been satisfied. e. A complete final inspection and approval by the County of the water and sewer system proposed by the Wildbrook Subdivision — Phases IA and IB, and receipt of other applicable documentation by the County. This acceptance and allocation of flow shall only be effective upon your compliance with all of the above terms and conditions and the County providing an acknowledgment that you have complied with all of the above terms and conditions. Included in this mailing is the Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE — 04/16) with the County's portion completed. If you have any questions, please do not hesitate to call me at 704-736-8497. Sincere' , .(31 Chuck King Engineering Associate Cc: File Imagery 2018 Google, Map data ©2018 Google 200 ft N LOCATION MAP NTS SITE Y. 13 up en In z TA m U z TOWNSEND DR WATER sLACKWOODS RD AKS DR HAGERS FERRY RD Ac(\\ AMERICAN Engineering American Engineering Associates -Southeast, PA, 8008 Corporate Center Drive, Suite 110 Charlotte, NC 28226 Office: 704,375,2438 www.american-ea.com Mailing Method: ❑ U.S. Postal Service Ej Certified/Registered Mail Other: ❑ Courierlland Delivery ❑ FedEx Priority Overnight ❑ FedEx 2-Day Delivery ❑ United Parcel Service (UPS) ® FedEx Standard Overnight 0 FedEx Economy Comments: Prestige Corporate Development, LLC intends to construct a new apartment complex in Lincoln County located near the intersection of Highway 16 and Triangle Circle. The parcel is part of an overall development known as Rivercross. The development of the proposed apartment complex will require the extension of a private sewer main from an existing manhole owned by Lincoln County. The new gravity sewer main and manholes will be instal'ed by Prestige Corporate Development and owned by the association ,,1 AMERICAN ■ Engineering Transm American Engineering Associates -Southeast, PA. 8008 Corporate Center Drive, Suite 110 Charlotte, NC 28226 e er Office: 704,375,2438 www.arnerican-ea.com To: Department of Environmental Quality — Division of Water Resources Mooresville Regional Office — Water Quality Section Attn: Barry Love 610 E. Center Avenue Mooresville„ North Carolina 28115 Telephone No: (704) 663-1699 From: American Engineering Tracey McCormick 8008 Corporate Center Dr. #110 Charlotte, NC 28226 704-375-2438 ext. 120 Subject: Rivercross Apartments — Fast Track Sewer System Extension Application We are sending you: Attached El Shop Drawings ❑ Prints Other, Date: July 12, 2018 RECF'IVEDINl D 'NRID R ❑ Under Separate Cover Via the Foliowing Items: ❑ Plans ❑ Specifications El Change Order ❑ Samples ❑ Copy of Letter ❑ Reports Rev. Description One original and one copy of the Fast Track Sewer System Extension Application and supporting documents $480.00 application fee (check #C111208) payable to NCDEQ Professional Engineer's Certification signed, sealed and dated Applicant's certification signed 1 NC Secretary of State LLC registration 6/15/18 Completed and executed FTSE 04-16 6/15/18 211.?17 oln County flow acceptance letter NCDEQ Residential Flow Reduction to Kullian Creek Wi°TP L'SOS and Vicinity Maps 5/2 Action* Approved Approved As Noted For Approval ❑ Other: Operational agreemen ❑ Correct and Resubmit ❑ File ❑ As Requested Resubmit Copies ❑ Return _ Copy/Copies ❑ Review and Comment