Loading...
HomeMy WebLinkAboutWQ0034830_Complete File - Historical_20171231r NCDENR North Carolina Department of Environment and Natural Resources Division of -Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director • Secretary June 29, 2010 Mr.Darrell Gettys, Executive Director of Facilities Lincoln County Board of Education 200 Shoal Road Lincolnton, NC 28092 Subject: Permit No. WQ0034830 East Lincoln High School —Athletic Field Complex Wastewater Collection System Extension Lincoln County, North Carolina Dear Mr. Gettys, In accordance with your complete application received on June 28, 2010, we are forwarding herewith Permit No. WQ0034830 dated June 29, 2010 for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-16991 Fax: (704) 663-6040 1 Customer Service: 1-877-623-6748 Internet: www.ncwaterqualitv.orq NorthCaro]ina d1laturallif Mr. Gettys Page 2 June29, 2010 In accordance with the provisions cf Article 21 cf Chapter143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 660 linear feet cf 3-inch force main, a 108 gallonper minute pump stations (with duplex pumps, on -site audible and visual high water alarm, and a portable generator with manual transfer switch), and the discharge of 10,965 gallons per day of domestic wastewater in conformity with 15A NCAC 2T, the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated n the Lincoln County WWTP (NPDES Permit No. NC0088722) prior to being discharged into the receiving stream. Assessing subsequent irnpacts to the downstream collection system and treatment facility is the complete responsibility of Lincoln County. Lincoln County must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the collection system permit WQCS00149. If any parls, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714, Unless such demands are made, this permit shall be final and binding. f you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. icerely, tar Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. ' f. A generalobservation of the entire sewer system shall be conducted at least once per year. g. inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. • This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, cr there is a name change of the Permittee. a 'formal permit request shall be submitted to the Division accompanied by documentation from the parties involved. and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved, Construction cf the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow cr bypass discharge of wastewater to the surface waters of the State Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the formeA complete certification is one where the form is fully executed and the supporting documents are provided as applicable, 7. A copy of the construction record drawings shall be maintaineid on file by the Permittee for the life of the wastewater collection facilities, Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T. the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215,6A through §143-215,6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10, The issuance of this permit shall not exenipt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local; state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B ,0200, erosion and sedimentation control requirements in 15A NCAC Chu 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H ,0500. 11, Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the [Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day. following the occurrence or first knowledge of the occurrence of either of the following; a, Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b Any failure of a pumping station or sewer inc resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility, 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of 'the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 29th day of June, 2010. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0034830 Fast Track Engineering Certification Permit No. VVQ0034830 June 29, 2010 OwnerMIQCS Darrell Gettys,Ex. Dir. of Facilities Lincoln County Board of Education 260 Shoal Road Lincolnton, NC 28092 \NWTP/WQCS PE Barry McKinnon David Lutz Lincoln County CES Group Inc. 115 West Main Street, 2nd Floor 274 N. Hwy 16, Suite 300 Lincclntcn_ NC 28092 Denver, NO 28037 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting In non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ] weekly, ❑ full time) the construction of East Lincoln High School — Athletic Field Grinder Pump, a Lincoln County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction. was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineers seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking alb partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) Owner/Permittee: la. Lincoln Co t Board of Ed Z O k " O Id.260 Shoal Road LL. Mailing Address lf. NC Z State O 1h. 704-736-9689 11, Telephone 2. Project (Facility) Information: 2a. ELincoln Hi h School — Athletic field Grinder P Brief Project Name (permit will er to this name) 3. Contact Person: ei 3a. David Lutz — Civil En inee Name and Affiliation of Someone Who Can Answeruestions About this Application Full Lega n1e (comp y, municip ty4OA, utility, etc.) Signi 9 icial Name and Title lease Executive Director of Facilities view I5A NCAC 2T .0106 (b) for authorized signing o icia s. The legal entity who will own this system is: Ej Individual 0 Federal 0 Municipality E3 State/County 0 Private Partnership D Corporation Other specify): BOE le. Lincolnton City lg. 28092 Zip Code id E-maU 2b. Lincoln County Where Project is Located ai Facsimile 3b. 704-489-1500 3c. dlutz@ces-group.net Phone Number E-mail 1. Project is i4 New 0 Modification (of an existing permit) If Modification, Permit No.: 2. Owner is Public (skip to Item B(3)) 0 Private (go to Item 2(a)) 2a, If private, applicant will be. 2b. If sold, facilities owned by a (must choose one) 0 Retaining Ownership (i.e. store, church, single office, etc.) or O Leasing units (lots, townhomes, etc. - skip to Item B(3)) O Selling units (lots, townhomes, etc. - go to Item B(2b)) 0 Public Utility (Instruction C) 0 Homeowner Assoc./Developer (Instruction D) 3, Lincoln County Owner of Wastewater Treatment Facility (WVVTF) Treating Wastewater From This Project 4a, Killian Creek 4b. NC 0088722 Name of VVWTF VWVTF Permit No. 5a. Lincoln 5b. 8" Gravity 5c. Owner of Downstream Sewer Receiving Sewer Size 0 Force Main Permit # of Downstream Sewer (Instruction E) 6. The origin of this wastewater is (check all that apply): E] Residential Subdivision 0 Apartments/Condominiums O Mobile Home Park El School 0 Restaurant 0 Office O Retail (Stores, shopping centers) Ej Institution 0 Hospital O Church El Nursing Home 0 Other (specify): % Domestic/Commercial % Industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) % Other (specify): 7, Volume of wastewat r to be allocated or permitted for this particular project: 10,965 gallons per day *Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: O Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line O Flow has already been allocated in Permit No. O Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA12/07 ►-. �9. 1 j Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in 1 ;Seats 1 Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). served on home side of football field: 2,193 WSFU = 90 = 90 gpm Wastewater: 5 gal/seat Due to anticipated full use of all fixtures at halftime, it is 2,193 * 5 = 10,965 gpd = 7.6 gpm anticipated the duplex grinder pump will receive approx. 90 gpm. 1 10. Summary of Sewer Lines to be Permitted (attach Size (inches) additional sheets if necessary) Length (feet) i New Gravity or Additional Force Main 3" 660 , Force W M 11. Summary of PumpStations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID Duplex Grinder Pump (self chosen - as shown on plans/map for reference) Z Z 0 r i Design Flow I Operational Point E (MGD) I GPM ©TM I i — Power Reliability Option 1 - permanent generator wIATS; 2 - portable generator will/ITS Force Main Size Force Main Length 0 r 0.01 108@34 2 3" 660' Z 0 1- Pump Station Location ID (self chosen - as shown on plans/map for reference) INFORMA Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; 2 - portable generator wIMTS Force Main Size Force Main Length cPump Station Location ID (self chosen - as shown on plans/map for reference) O. Design Flow I (MGD) m I Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; 2 - portable generator w/MTS Force Main Size Force Main Length JJ� 12. ■ Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? Yes Z No If Yes, permit number of 2nd treatment facility (RO — if "yes" to 8,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (Latest version) and 15A NCAC Chapter 2T as applicable? Z Yes ■ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA12/07 4. Have the following permits/certifications been submitted for approval for the system or project to be served? • Wetland/Stream Crossings - General Permit or 401Certification? Sedimentation and Erosion Control Plan? Stormwater? ❑ Yes ❑ No ® Yes ❑ No ® N/A ❑ NIA ❑ Yes ❑ No ® NIA 15. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: Eland provide details cn Z 0 1— Q U_ LL l-- W U U OwnerlPermittee's Certification: (Signature of Signing Official and Project Name) 1, _Darrell Gettys , attest that this application for East Lincoln High School -- Athletic Field Grinder Pump has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well afivil penalties r9p to $25,000 per violation. Signing Official Signature ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, David Lutz , attest that this application for East Lincoln High School — Athletic Field Grinder Pump has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my • knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Perrnitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. INpV I7 ]-L.rvL Professional Engineer Name 2b. CES Group Inc Engineering Firm 2c. 274 N. Hwy 16, Suite 300 Mailing Address 2d. Denver City 2g. 704-489-1500 12h. 704-489-6500 Telephone Facsimile 2e. NC 2f. 28037 State i Zip --1 2i. dlutz@ces-group.net E-mail CARri aQ` • �� S S%0 * . s • •a SEAL 9r; •:�Gli�E��� ;1111111110 NC PE Seal, Signature & Date FTA12107 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FT SI—10/07) Project Applicant Name: Lincoln County Board of Ed Project. Name for which flow is being requested: East Lincoln 11. S....._ R.estroom Replacement More than one !r 7 Sf;- l ll.='07 ,mcn be required fbr a single project if the owner o„ the H W77' is not responsible Jar all pump stations along the route of"the proposed -wastewater: w. Iv Complete this section only if you are the owner of the wastewater treat meat pla a WWTP Facility Name: Killian Creek. b, WWTP Facility Permit 11: NC 0088722 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the W e. WWTP facility's actual avg_ flow f Total flow for this specific request g. Total actual and obligated Flows to the facility IL Percent of permitted flow used All flows are in MGD 1.68 _.. __.._.0.00168 0.0�_�,.._...�._ 0,001 0,002168_ 0.. 1 2%Q IT, Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station. Name Forney Creek Relief PS Killian Creek WWTP PS A'pprox, Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD 1000 1.68 0.00 0.00 Ill. Certification Statement. 1 Barry L. McKinnon_.__._.._.., , certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data, This certification applies to those items listed above in Sections 1 and II for which t ani the responsible party. Signature of this form indicates acceptance of „ . e water flow. r,% civil engineering environmental science landscape architecture land planning 274 N. HWY16 SUITE 300 DENVER„ NC 28037 I 704..489.1500 F .704489.6500 denver nc charlotte, nc bloomington il June 2, 2010 State of North Carolina Department of Environment and Natural Resources Division of Water Quality 919 N Main Street Mooresville, NC 28115 Attn: Dee Browder Re: Engineer's Report Ms. Browder, The following report is for the new sewer line proposed at East Lincoln High School, in Lincoln County. The concessionirestroom building for the football field is being replaced and the existing septic tank is proposed to be abandoned: A 6" gravity sewer from the new structure will tie into a new duplex grinder pump system near the softball field: At this time, a new structure at the softball field is an alteranate, therefore it may not be constructed at this time. Waste will be pumped from the new grinder pump, approximately 660 LF to an existing manhole, located on the Catawba Elementary School property. From this point, the sewage will gravity flow. Please find the application, fee, plans and specifications attached. Please feel free to contact me with any comments or questions. Sincerely, David Lutz, P.E. Cc: Lincoln County Public Works, Barry McKinnon File \\\00111/0/ • 0 ‘-'1..^ : Q. SEAL F.; 032866 • " 1,2„) is \ S Group, kic Permit Number WQ0034830 Central Files: APS SWP 06/29/10 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 individual Extensions Primary Reviewer dee.browder Coastal SW Rule Permitted Flow 10965 Facility Permit Contact Affiliation Facility Name Major/Minor Region East Lincoln High School -Athletic field grinder Minor Mooresville pump Location Address County Lincoln Owner Facility Contact Affiliation Owner Name Lincoln County Board of Education Dates/Events Orig Issue 06/28/10 App Received Draft Initiated 06/17/10 Scheduled Issuance Owner Type Government - County Owner Affiliation Darrell Gettys Public Notice Issue 06/28/10 Effective 06/28/10 Regulated Activities Resuested/Received Events School Additional information requested Wastewater collection Outfall NULL Additional infarmation.received Expiration 06/17/10 06/28/10 Waterbody Name Stream Index Number Current Class Subbasin RECEIVED DIVISION OF WATER QUALITY 0 2i)) Fast Track Engineerino Certification Permit No, WQ0034830 June 29, 2010 Owner/WQCS Darrell Gettys,Ex. Dir. of Facilities Lincoln County Board of Education 260 Shoal Road Lincolnton, NC 28092 MOO S P SECTION tt LE REGIONAL OFFICE WWfPAWQCS PE Barry McKinnon David Lutz Lincoln County CES Group Inc. 115 West Main Street, 2nd Floor 274 N. Hwy 16, Suite 300 Lincolnton, NC 28092 Denver, NC 28037 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division,. ENGINEERS CERTIFICATION 0 Partial Final , as a duly re•istered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically„ weekly, 0 full time) the construction of East Lincoln High School— Athletic Field Grinder Pump, a Lincoln County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T, the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. S i. ri3 r k State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE—10/07) Project Applicant Name: _Lincoln County Board of Ed Project Name for which flow is being requested: East Lincoln H. S. — Restroom Replacement More than one F1'SE--10/07 may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Killian Creek b. WWTP Facility Permit #: NC 0088722 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow £ Total flow for this specific request • g. Total actual and obligated flows to the facility h. Percent of permitted flow used MI flows are in MGD 1.68 0.00168 0.0 0.001 0.002168 0.12% H. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD Forney Creek Relief PS LOO 0.00 Killian Creek WWTP PS 1.68^ 0.00 III. Certification Statement: I, Barry L. McKinnon , certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II for which I am the responsible party. Signature of this form indicates acceptance of water flow. I _ ��f idr F7 Si trig Official Signature Date WHR& ; - WHR2O.' 2" Solids Handling Sewage Pumps and Effluent Pumps Single Seal /54( MEMBER el° rr HE WHR5H WHR2OH SERIES PUMPS ARE DESIGNED FOR USE IN LIGHT COMMERCIAL AND RESIDENTIAL RAW SEWAGE AND EFFLUENT APPLICATIONS. They deliver higher heads than standard sewage pumps and will pass 2 inch solids. Recessed vortex impeller provides an unobstructed passage in the volute case, allowing the pump to handle stringy trash without plugging the impeller. For more information, call your Myers distributor, or the Myers Ohio sales office at 419-289-6898. ADVANTAGES BY DESIGN DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE. ■ O11-filled motor for maximum heat dissipation and constant bearing lubrication. • Recessed vortex impeller reduces radial bearing loads, increases bearing life. • Single phase PSC motors have no starting switch. NON -CLOG OPERATION ■ Recessed vortex impeller passes 2" solids. • Impeller operates completely out of volute passage ■ Passes stringy trash and other solids which conven- tional semi -open impellers can't. PRODUCT CAPABILITIES Capacities To 2I5 GPM 814 LPM Heads To 70 ft. 20.9 m Solids Handling Capacity 2 in. ' 50.6 mm Liquids Handling raw and effluent sewage Intermittent Liquid Temp, up to 140° F up to 60° C Winding Insulation Temp, (Class B) 266°F 130°C Motor Electrical Data 1/2, 1, 11, 2 HP 3450 RPM 115, 208/230V,, 10, 60 Hz PSC 200/230/460/575V, 30, 60 Hz Third Party Approvals CSA Acceptable pH Range 6 - 9 , Specific Gravity .9 - 1.I Discharge, NPT (optional) 2 in, 3 in. 50.8 mm 76,2 mm Min. Sump Diameter Simplex Duplex 24 in. 30 [n. 61,0 cm 91.4 cm Note: Consult factory for appliaatfons outside of these recommendations. Construction Materials Motor Housing cast iron Volute Case cast iron Impeller ductile iron Power Cord single seal 10, 20' SJOOW/SJOOW--A 30, 20' SOOW Mechanical Seal single, type 21, carbon and ceramic Pump Shaft and Motor Shaft 416 SST WHERE INNOVATION MEETS TRADITION Myers' Pentair Water POWER CORD Jacket sealed with compression fittings. Individual wires potted with epoxy to prevent wicking in case of cord MOTOR HOUSING damage. Cast iron for efficient heat transfer and corrosion resistance. IMPELLER Recessed vortex impeller operates completely out of volute passage. BEARINGS Upper and lower ball support rotor. Take radial and thrust loads, MOTOR 1/2, 1 1-1/2 and 2 HP single or three phase, 60 Hz, 3450 RPM. Single phase PSC motors have built-in on winding overload protection, oil -cooled and lubricated. CAST IRON VOLUTE Corrosion resistant. Passes 2° spherical solids. 2° NPT discharge, Optional 3° flange, DIMENSIONS (Dimensions in MM) 193/4" (502) 21/8" (54) 215/1s (75) 2" NPT Flanged Discharge, 3" NPT Optional WHR15H-01 WHR15H-21 ' WHR15H-03 WHR15H-23 WHR15H- 3 WHR15H-53 WHR1 OH-01 WHR1 OH•21 WHR10H-03 WHR1OH-23 WHR1OH-43 WHR1OH-53 1 V N I V 1 V N N N N N N N N i Motor Electrical Data a1rno. c 0000000gmcnOoo cnoo,,m (noa cnoon ff CO CO CO Co" G.)Ca CO GI -+ CO CO CO CO-. -. CO CO CO CO -, -. .o d 8$888 S'S'oo'S'o o'0000S) o888'$'00 Hertz Co8 A W W A O O O in FV TA 00 W m C O C O A i0 N FnOOf2il E O O O in O o coal8g888 -`-A N N N N A Start Amps m ACO 88Ea Co in O A O Wca V CO W " in V in _.. m NW V VNA Coin O :V CD is -+N 4cn 0 A4 8 b Co 1,1 h+ 6 6 ip g a p f!) Cil CO CO ca Cv 66.1 Ea Ca Co NN CO CO CoCa Coin Co Co Ca Ea NN NN CO CO it in cninOO A!CA AA V l[D Co min CDa L]is +ih " " t ;o�Co in ininm ^FW "" 0"a"PP. inioinmCaoo mmmvmui F..'4] oO era:tAm Start KVA CoCoCoCoCo CoCo o) Cn V caW W cacaW LA 1 A CN caW WcaNN OOOO CA m i0 Era in i➢ C/1m Co M nX y G)GIG)G)m G)0G)'nC)0 TSTTc- mCD CD COm375xi= emuivJ lad suojieo 0 0 O O O O O 1. 0 0) 0 CO O N O N 0 .D 0 0 0 0 Total Head in Feet 0 0 0 rn O IP cn O cn Total Head in Meters 0 W O O O O 01 O O 0) 0 0 CO O O CO 0 0 e nulw lad SJe;rl irgloedeo • Company: Preferred Sources Name: Limccln Park Date: 5/4/2010 Pum. Data Sheet - M ers Myers Pump: Search Criteria: Size: WHRSH-20H Flow: 108 US gpm Head: 34 ft Type: Non -dog Speed: 3450 rpm Fluid: Synch speed: 3600 rpm Line: WHR15H, 1.5HP Curve: Impeller.Water. Temperature: 60 °F Density: 62.37 lb/ft' Vapor pressure: 0.2563 psi a Specific Speeds: Ns: — Viscosity: 1.105 cP Atm pressure: 14.7 psi a Nss: — Dimensions: Suction: -- Discharge: — Motor Pump Limits: Temperature: — Pressure: — Sphere size: -- - Data Point -�- Flow: 108 US gpm Head: 34.8 ft Eff: --- % Power. 1.5 hp NPSHr: ' --- Design Curve Shutoff head: 59.3 ft Shutoff dP: 25.7 psi Min flow: — BEP: -- NOL power. 1.5 hp @ 10 US gpm Max Curve :- Max power. 2hp@10USgpm Power: -- Eye area: -- WHR2OH, 2HP 70 60 WHR15H, 1.5HP 50 WHR10H, 1HP 40 0 T 30 20 10 0 1.5 WHRSH, .5HP 20 40 60 NPSHa: --- Size: 1.5 hp Standard: NEMA Speed: 3600 Enclosure: TEFC Frame: 143T Sizing criteria: Max Power on Design Curve 80 100 1 hp 120 0.5 hp 0.75 hp 140 160 180 • 1.5 hp 200 220 20 40 60 80 100 120 140 160 180 200 220 US gpm Performance Evaluatiori: Flow Speed Head Efficiency Power NPSHr US gpm rpm ft % hp ft 130 3450 27.9 — 1.5 108 3450 34.8 --- 1.5 86.4 3450 40.9 — 1.5 — 64.8 3450 46.4 --- 1.5 — 43.2 3450 51.1 — 1.5 2 hp Myers MAPS 6 6 Selected from catalog: Myers 60Hz Vers: Nov 2009 Y Wet Well Floor Elevation Off Float Elevation On Float Elevation Lag Float Elevation High Water Float Elevation Volume of a round wet well Tank Diameter in feet (rxr)3.14 / 231 = gallon/inch Raduis 4 24 24 3.14 231 7.83 Design Flow Rate of the Pump Comment: 90 90 90 7.83 11.49 inches per minute (ipm) 11.49 2 22.99 inches minimum between OFF float & ON Boat Cycles per Hour based upon incoming flow rates of #ofHomes xgpdxPF/1440=gpm 1 Number of pumps Gallons between the Off & On float Minutes to activate the ON float Minutes of pump run time Total Cycle Time Total Cycles per hour per pump 129600 90.00 1 1440 90.00 2 180 2.00 2 4.00 7.50 Minimum Submergence required for Myers WHR15H Series pui Inches Feet 1.6 1.33 Distance from wet well floor to weight located on the float in feet 0 1.33 3.25 4.25 4.75 • 1-action Loss per Total 100' of length of GPM Static Head pipe pipe/100 TDH 0 15 0 7.15 15 0 15 0 7.15 15 108 23 1.53 7.15 33.9395 0 15 0 7.15 15 0 15 0 7.15 15 Feet of Pipe Pipe Type ID 715 SDR 21 3.166 GPM Head Loss Per 100' 90 1.53 Total Head Loss 10.9395 Static Elevation Change High Point 803 Low Point 780 Total Static Elevation Change 23 Total Dynamic Head (TDH) Total Static Elevation Change 23 Total Head Loss 10.9395 TDH in Feet 33.9395