Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0029339_Regional Office Historical File Pre 2018 (2)
rc4 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality October 3, 2005 Mr. Dwight Sherrill, Manager The Denver Group, LLC PO Box 713. Denver, North Carolina 28037 Subject: Permit No. WQ0029339 The Villages at Cowans Ford, Phase 2 Wastewater Collection System Extension the Denver.GFoup, LLC Lincoln County,.North Carolina Dear Mr. Sherrill: In accordance with your application received on September 8, 2005, we are forwarding herewith Permit'No. WQ0029339, dated October 3, 2005, to The Denver Group, LLC for the construction only of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be•subjectto the conditions and limitations -as specified therein. This cover ietter-shall'be considered a part ofthis permit and is therefore incorporated therein by reference. .Please .pay .particular .attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted ,June 1, 2000, as applicable, unless specifically ;mentioned herein. Division approval is based on acceptance of .the certification provided "by a -North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in .accordance with North Carolina General Statute §143-215.6A 'through §143215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the Iicensing board. Mooresville Regional Office 610 East Censer Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet h2o.enr.state.nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50°% Recycledll0°% Post Consumer Paper It�o�tCarolina ,Naturally Mr. Sherrill Page 2 October 3, 2005 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to The Denver Group, LLC for the construction of approximately 3,294 linear feet of 8-inch gravity sewer as part of The Villages at Cowans Ford IV, Phase 2 project, and the discharge of 0 gallons of wastewater into the'Lincoln County existing sewerage system, pursuant to the application received September 8, 2005, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and .Force .Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewageand wastewater collected by this system shall be treated in the Lincoln County WWTP (Forney Creek NPDES No. NC0074012) prior to being discharged into the receiving stream. If any parts, -requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Lincoln County Health Department Mooresville Regional Office, Surface Water Protection (WWTP Permit No. NC0074012) Mitchell Latham, Latham -Walters Engineering, Inc. Surface Water Protection Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall.be effective from the date of issuance until rescinded and shall'be subject to the following specified conditions and limitations: 1. This ,permit !shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions •of.this permit; 15A NCAC .2H .0200; the .Division of Water Quality's (Division) •.Gravity Sewer Minimum Design Criteria adopted February 12, 1996,.as •applicable; the Division's 'Minimum 'Design .Criteria for the Fast -Track Permitting of Pump .Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Pemmiftee shall maintain .compliance with an individual system -wide collection system permit for the operation and maintenance .of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as ,provided in 15A NCAC 2H .0227: a. The sewer system shall -be effectively maintained :and operated at al! times to prevent discharge to land or surface waters, and any contravention of the groundwater. standards .in 15A.NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. Amap of the sewer system shall be developed and shall be actively•maintained. c. An operation and -maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period •of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a 'period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B ..0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formai permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed 'Engineering Certification form attached to this permit shall be submitted with the required supporting documents tothe address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track .Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through .§143 215.6C. 9. In the event that the wastewater collection facilities fail to perform 'satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those .as may be required by this Division, such as .the construction of additional or replacement facilities. 10. The issuance of this .permit shall not exempt the Permittee from complying with any and all statutes, 'rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General 'Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the -following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved foram) can also be completed to show that the SSO was beyond control. Permit issued this the 3rd day of October, 2005. NORTH CAROLINA ENVIRONMENTAL'MANAGEMENT COMMISSION for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0029339 3 • • Fast Track Engineering Certification Permit No. WQ0029339 October 3, 2005 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changesto the project should be clearly identified on the record drawings or in written summary form. Permit modificationsare required for anv,changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all -required supporting documentation have been received by the Division. Therefore, it is'highly recommended that this certificationbe sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final as a.duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of The Villages at Cowans Ford IV, Phase 2, Lincoln County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used.in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200;.the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Pen-nittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. TE OF NORTH CAROLINA COUNTY OF Lincoln Permit No. DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (d.l) and entered into this 2 day of May, 2005, by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and The Denver Grou LLC , a corporation/general partnership registeredllicensed to do business in the State of North. Carolina, hereinafter.. known as the DEVELOPER. WU NESSETH: The DEVELOPER is the owner of the certain lands lying in a 5 _Liras upon which it is erecting and will erect dwelling units and other improvemen known as The Villages at Cowans Ford IV- Phase 2 Development), n said devel p County, ent to be (hereinafter the The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, andlor disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands, The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal. System. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the ti. Declaration, the The Villages at Cowans Ford IV - Phase .2 of filing of the (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: . The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law, The DEVELOPER shall not: transfer ownership andlor control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Quality has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association, The FORM: DEV 02/03 Pace 1 of 2 t include a copy of the Association Bylaws and Declaration. DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments t cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. Ha wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewate of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaw5. that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. f WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the rties hereto on the day and year written as indicated by each of the parties named below: )R THE ENVIRONMENTAL ANAGEMENT COMMISSION D e� Stan W. Klime P.E., Dir for ivision of Water Quality ►ate) The Denver Group, LLC Name of DEVELOPER Dwight Sherill, Manager Print Name and Title May 2, 2005 (Date) SACK APPLICATION for GRAViTt SE4 iERS, PUMP STATIONS, AND FORCE AINS PAGE 3 USE THE TAB KEY TO '"uOrE FROM FIELD P 0 FIEL 1. Owner: 1 a. The Denver Group, t_LC Application Number r , � (to be completed by DWQ) l Full Legal Name (company, municipality, HOA, utility, etc.) z lb. Dwight Sherrill, Manager O Signing Official Name and Ti Please review 15A NCAC 2H :02 (b) for authorized signing offic Q lc. The legal entity who will own this system is. 0 Individual El Federal 0 Municipality 0 State/County © Private Partnership X Corporation 0 Other (specify): ld. P.O. Box 713 O Street Address LL 1 f_ North Caroli+r Zr State Q 1 h_ 828--244 -2t134 0 H li. 704-895-8485 Telephone 2. Project (Facility) in rrnations Facsimile 1e. Denver City lg. 28037 Zip Code E-mail 2a. The Villages at Cowans Ford iV, Phase 2 2b Lincoln Brief Project Narne (permit will refer to this name) County Where. Project is Located 3. Contact Person Dwight Sherrill 3a_ Mitch S Latham, PE, Latham -Walters Engineering, Inc_ Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-895-8484 Phone Number 1. Project is x New © Modificat rsrt (of an ex perms ) 3c. m51we99©bellsouth.net E-mail If Modification, PeitNo.: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing fine size/iength, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is Public0 (skip to Item 8(3)) X Private (go to Item 2(a)) 2a. If private, applicant will be. 0l Retaining Ownership (i.e. store, church, single office, etc.) or 0 Leasing units (lots, townhornes, etc. - skip to Item 8(3)) X. Selling units (lots, townhomes, etc. - go to Item B(2b)) Lincoln County ... Owner of Wastewater Treatrdtent Facili 4a. Forney Creek VVWTP 2b. If sold, facilities owned by a (must choose one) 0 Public Utility (Instruction III) X Homeowner Assoc./Developer (instruction IV) astewater From This Project 4b, NC0074012 Name of WWVTF WWTF Permit No.. 5a. Linen Count! 5b. $7 wit Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstre $. The origin of this wastewater is (check all that apply): X Residential Subdivision DApartments/Condom norms O Mobile Home Park 0 School O Restaurant 0 Office 0 Car Wash O Institution Hospital 0 Church O Nursing Horne 0 Other (specify): _ 7. Volume of wastewater to be permitted in this project: 26,64© gallons per day % Domestic/Commercial % Industrial % Other (specify): 8. If thepermitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. O Rehabilitation or replacement of existing sewer with no new flow expected Fi- CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS 9- i PAGE4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .02190)(3). 74 Single Family Residential Lots Flow = 74 Lots x 360 gpd/lot 26,640 gpd ' 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 r. C 6 iW —1 Length (feet) 3294 I-- - _ - -- + - - - Z z O ENTER TOTAL LINE LENGTH IN MILES - 0.624 - -Q 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) - --- J Location ID - � -------^----�-------------- ;--_ - ---LL. Power Reliability Option re (self chosen - as shown on ' Design Flow! Operational Point ' (1- dual line feed; 2- permanent generator w1ATS; 3- O plans for cross-reference) — (MGD) —4_ GPM @ TDH _ portable generator wltelemetry; 4 wet well storage) Gravity or Force Main (use the pull down menu) Gravity - -- -+ - rg , i iW ' 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force ai1 Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? x Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION :13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No x N/A Sedimentation and Erosion Control Plan? x Yes ❑ No ❑ N/A Stormwater? 11 Yes ❑ No x N/A CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on map for cross-reference) Name of Waterbody County River Basin Waterbody Stream Index Waterbody Classification A UT to Catawba River Lincoln Catawba 11-(112) Ws-IV,CA 1 Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! la. Applicant's Certification: 1, Dwight Sherrill, attest that this application for The Villages at Cowans Ford IV, Phase 2 has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143 215 6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to $25, o0q per violation. Signing Signatu Professional Engineers Certification: 1 attest that this application for The Villages at Cowans Ford 1V, Phase 2 has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all othersupporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. 2a. Mitch S. Latham, P.E. Professional Engineer Name 2b. Latham -Walters Engineering, Inc. Engineering Firm 2c. 16507-A Northcross Drive Address 2d. Huntersville City 2g. 704-895-8484 12h. 704-895-8485 1 Telephone j Facsimile �2e. NC in28078 State I Zip i2i. mslwe99@belIsoulh.net E-mail Seal, Signature & Date COUNTY OF LINCOLN, NORTH CAROLINA 115 WEST MAIN STREET, 2NE, FLOOR CITIZENS CENTER, LINCOLNTON, NORTH CAROLINA 28092 DEPARTMENT OF PUBLIC WORKS PHONE (704) 736-8495 FAX (704) 736-8499 September 1, 2005 Latham — Walters Engineering 16507-A Northcross Drive HuntersvilIe, NC 28078 Subject: Sewer Availability in The Villages of Cowans Ford IV, Phase 2 Dear Mitch, We, have reviewed the plans for The Villages of Cowans Ford IV, Phase 2. At this time there is capacity in our sewer plant to accept the flows for these 74 additional homes. However, Pump Station #10, which will receive these flows, is not adequate to handle them and will require an upgrade. This problem with Pump Station #10 was originally noted when back in 2002. The estimated cost for the upgrade at this time is $177,500. This includes new pumps, new controls and a new generator. It will upgrade Pump Station 410 from 180 gpm to 400 gpm, a 220 gpm increase. The projected sewer flows from The Villages of Cowans Ford 1V, Phases 1 & 2, Somerset, and the proposed retail area in the plan add up to 111,960 gpd. This translates to 195 gpm peak flow. This flow will use up 88% of the new capacity at Pump Station #10. We, therefore, expect the Denver Group and their associates to cover 88% of the cost of the improvements on Pump Station #10. This equates to $156,000. Once we receive the payment, or work out some agreement, we will begin the process of making the needed improvements to Pump Station #10. We would agree to allow the sewer infrastructure construction to begin on Cowans Ford 1V, Phase 2 once these details are worked out. However, the flows from this subdivision will not be accepted until the improvements to Pump Station #10 are completed. Please feel free to call if you have any questions or would like to discuss this further. c. Steve Gilbert File Copy Permit Number WQ0029339 Central Files: APS� SWP__� 10103/05 Permit Tracking Slip Program Category Non -discharge Status Project Type In review New Project Permit Type Version Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Extensions Primary Reviewer dee.browder Permitted Flow 0 Facility Permit Classification Individual Permit Contact Affiliation Facility Name The Villages at Cowans Ford IV, Phase 2 Location Address Owner MajorlMinor Region Minor 'Mooresville County Lincoln Facility Contact Affiliation Owner Name Owner Type The Denver Group LLC Non-Govemment Dates/Events Scheduled Orig Issue App Received Draft Initiated Issuance 09/08/05 Owner Affiliation Dwight Sherrill PO Box 713 Denver NC 28037 Public Notice Issue Effective Expiration Regulated Activities Requested/Received Events Subdivision Additional information requested Wastewater collection Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class 5ubbasin JAN•H.Ifl051138W663nn"Is1,4 V9V8-S6s (VOU :sNOErd `u ui -s IiatimiN 3ai'[uM W 1l I 'Xiaaaauis -pafoid sc gipa aougsisse ioj •uogetuaoJtn ieuotitppe Cue annbai so suotjsanb duu ansq nod JI i8ti8-S68 (toL) W atu Id •ienoxddd oil s aoj pa nugns Afityloadsal si ieuaTetu sits, loafoad paouaaalaz anogs NT 011.108 03 pug aannas pasodoad atp ioj 00'0017$1o3 Apollo aaj uoieogdde pre luaumaitie iuuoguaado madoianap atp jo sardoo onu pus ieuiZuo auo 14unop uiooutj mg lanai aousjdaooe mog aquo saidoo one ¶oafoid aq; jo sdeui oigthu odo3 sosfl ioioo once `()Cdoo auo pus ivatuo auo) uuoj uotJeogdde papiduroo atp jo slas oral motile pug maid :suistlitlhf, 's]A araG 9 $.' •ui(oae3 t oN '�unop uiooun NOUNS�'�� 1 �]I ti AZ qd AI plod suemo3 IR saen!A aqs IT uogeagddy Jamas 3a1.I. e3 :parqns {;OOZ 8 0 dg$ PLIJO 1 c' — ; s:AS3HDGG 63311nOsp,)i iy fliVN Old' S i 18Z 'ON `aii?Asaaoop\I PallS UNHQWN opal() Ieuopla21 aiitnsaroow •suregitm Epos •sw 500Z `9 aaguia3das 9LO8Z VNriOHV3 1-11xON 63TIAs2i3.I.NfH RAMC! SSOIOHJ2T[ON V-LOS9 L 5NR133NI N3 SaaL1vM VWHLV1 ffii4 3 COUNTY OF LINCOLN, NORTH CAROLINA 1 1 5 WEST MAIN STREET. 2NE FLOOR CITIZENS CENTER, LWCOLNTON. NORTH CAROLINA 28092 DEPARTMENT OF PUBLIC WORKS PHONE (704) 736-8495 FAX (704) 736-8499 September 1, 2005 Latham — Walters Engineering 16507-A Northcross Drive Huntersville, NC 28078 Subject: Sewer Availability in The Villages of Cowans Ford IV, Phase 2 Dear Mitch, We, have reviewed the plans for The Villages of Cowans Ford IV, Phase 2. At this time there is capacity in our sewer plant to accept the flows for these 74 additional homes. However, Pump Station # 10, which will receive these flows, is not adequate to handle them and will require an upgrade. This problem with Pump Station #10 was originally noted when back in 2002. The estimated cost for the upgrade at this time is $177,500. This includes new pumps, new controls and a new generator. It will upgrade Pump Station #10 from 180 gpm to 400 gpm, a 220 gpm. increase. The projected sewer flows from The Villages of Cowans Ford IV, Phases 1 & 2, Somerset, and the proposed retail area in the plan add up to 111,960 gpd. This translates to 195 gpm peak flow. This flow will use up 88% of the new capacity at Pump Station #10. We, therefore, expect the Denver Group and their associates to cover 88% of the cost of the improvements on Pump Station #10. This equates to $156,000. Once we receive the payment, or work out some agreement, we will begin the process of making the needed improvements to Pump Station 1110. We would agree to allow the sewer infrastructure construction to begin on Cowans Ford IV, Phase 2 once these details are worked out. However, the flows from this subdivision will not be accepted until the improvements to Pump Station #10 are completed. Please feel free to call if you have any questions or would like to discuss this further. c. Steve Gilbert File Copy