Loading...
HomeMy WebLinkAboutWQ0033714_Regional Office Historical File Pre 2018ATA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee -Freeman Governor Director Secretary February 11, 2009 Mr. Rob Neill, Manager Primax Properties 1065 East Morehead Street Thomas J. Roberts, President Charlotte, NC 28204 Subject: Permit No. WQ0033733 Rite Aid: Brawley School Road Wastewater Collection System Extension Iredell County, North Carolina Dear Mr. Neill, In accordance with your application received on February 2, 2009, we are fonNarding herewith Permit No. WQ0033733 dated February 11, 2009, to Primax Properties for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division. of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer .in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office Location:.610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-16991 Fax: (704) 663-60401 Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.orq An Equal Opportunity 1 Affirmative Action Employer — 50% Recycledll0% Post Consumer paper Na rthCarolina Naturally Mr. Neill Page 2 February 11, 2009 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of, approximately 176 linear feet of 1.5-inch force main, a 22 gallon per minute pump stations (with duplex pumps, on -site audible and visual high water alarm, and a permanent on -site generatorwith automatic transfer switch)and the discharge of 11,180 gallons per day of domestic wastewater into the Town of Mooresville existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Town of Mooresville WWTP (NPDES Permit No. NC0046728) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of the Town of Mooresville. Mooresville must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the collection system permit WQCS00043. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files Michael Newman, PM Engineering, Inc. Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 11th day of February, 2009. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0033733 3 Fast Track Engineering Certification Permit No. WQ0033733 February 11, 2009 OwnerANQCS WVVT'P/WQCS Rob Neill, Manager Steven Hussman, Town Manager Primax Properties Town of Mooresville 1065 East Morehead Street 413 N. Main Street Charlotte, NC 28204 Mooresville, NC 28115 PE Michael Newman PM Engineering, Inc. 4601 Charlotte Park Dr, Suite 160 Charlotte, NC 28217 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Rite Aid: Brawley School Road, an Iredell County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 0 ILL USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner/Permittee: la. Primax Properties Application Number: (to be completed by DWQ) Full Legal Name (company, municipality, HOA, utility, etc.) b. Rob Neill, Project Manager Signing Official Name and Title (Please review '15A NCAC 2T .01t (b) for authorized signing officials!) The legal entity who will own this system is'. ❑ Individual ❑ Federal ❑ Municipality ❑ State/County ❑ Private Partnership ld. 1065 East Morehead Street Mailing Address If. North Carolina State 0 z 3b. 704-521-9973 Phone Number 1 h, 704- 954-7215 Telephone 704-905-3952 Facsimile 2. Project (Facility) Information: 2a. Rite Aid: Brawley School Rd of Project Name (permit will refer to this name Contact Person: Michael Newman, PM Engineering, Inc e, Charlotte City g, 28204 orporation ❑ Othe Zip Code robneill@a primaxprope E-mail 2b. Iredell _ County Where Proje Name and Affiliation of Someone Who Can Answer Questions About this Application mnewman e@pmchariotte.co E-mail _ Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No,: es.com is Located 2. Owner is ❑ Public (skip to Item B(3)) 2a, If private, applicant will be: ® Priva go to Item 2(a)) 2b. If sold„ faci E Retaining Ownership (i.e. store, church, single office, etc,) or ❑ Leasing units (lots, townhomes, etc. - skip to item B(3)) Selling units (lots, townhomes, etc. - go to item B(2b)) Town of Mooresville Owner of Wastewater Treatment Fac 4a. Name of WWTF 5a. Town of Mooresville 5b. Same as current Owner of Downstream Sewer ;;Receiving Sewer Size B. The origin of this wastewater is (check all that apply): El Residential Subdivision ❑ Apartments/Condominiums ❑ Mobile Home Park ❑ School ❑ Restaurant ❑ Office ting Waste ties owned by a spec' ust choose one) ❑ Public Utility (Instruction C) ® Homeowner Assoc./Developer (Instruction D) ler F 4b, of This Pr IZ Retail (Stores, shopping centers) ❑ Institution ❑ Hospital ❑ Church ❑ Nursing Home Other (specify): 100 % Domestic/Commercial % Industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) % Other (specify): Volume of wastewater to be allocated or permitted for this particular project: 1118 GPD *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: ❑ Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No, ❑ Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA 121 7 vcr2 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). Used 100 gal/1,000 SF for "stores and shopping centers without food service." Building is 11,180 SF. 11180 x .1=1,118 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 1.5 E Length (feet) New Gravity or Additional Force Main 176 Force Main i L. ❑ 11. Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) 111 Pump Station Location ID #1 (self chosen - as shown on plans/map for reference) Z I- Z 0 V__.-..._: Design Flow MGD (MGD) I Operational Point!1...,,.. _. _._.___._.__._.. — __„� Power Reliability Option GPM @TDH i - permanent generator MATS; Force Main Size , 2 - portable generator w/MTS , _.............__._._._m..._.. _..........__..... - ...... Force Main Length `-' .00111E 22 GPM @ 15 TDH; 1 1.5" { 176 RMIT INFORMATION Pump Station Location 1D (self chosen - as shown on plans/map for reference) Design Flow (MGD) Operational Point', Power Reliability Option i GPM TDH 1 - permanent generator w1ATS; I Force Main Size 1 e2 - portable generator w/MTS 1 Force Main Length k k Pump Station Location ID (self chosen - as shown on plans/map for reference) W CO2 Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option • 1 - permanent generator w!ATS; Force Main Size i - portable generator w/MTS j L Force Main Length 12. ■ Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? Yes ® No If Yes, permit number of 2nd treatment facility 113. (RO - if "yes" to 6,12 please contact the Central Office PERCS Unit) Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? �) Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 12/07_ver2 14. Have the following pemnits/certifications been submitted for approval for the system or project to be served? Wetland/Stream. Crossings - General Permit or 401 Certification? ❑ Yes 0 No ® N/A Sedimentation and Erosion Control Plan? ® Yes 0 No ❑ N/A Stomiwater? 0 Yes ❑ No ® N/A . Does this project include any high priority lines, [see 15A NCAC 02T 0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once everer six months heck if Yes: ❑ and provide details OwneriPermittee's Certification: (Signature of Signing Official and Project Name) Ve-1 , attest that this application for Rite Aid Sewer Extension has been reviewed by me and is accurate and complete to the best of my knowledge. i understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, ning Official Signa ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY y TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 Date Professional Engineers Certification: (Signature of Design Engineer and Project Name) !, Michael Newman , attest that this application has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance.. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this materia! and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation, a. Michael D. Newman Professional Engineer Name PM Engineering, Inc Engineering Finn c. 4601 Charlotte Park Dr, Suite 160 Mailing Address d. Charlotte City g. 704-521-9973 2h. 704-521- Telephone Facsimile 2e. NC j2f. 28217 I Zip State io mnewman@pmcharlotte,com E-mail NC PE Seal, Signature& Date FTA 12/07_ver2 oc. WAr�gpG - G3 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE —10/07) Project Applicant Name: Town of Mooresville Project Name for which flow is being requested: RI‘AI., Ptti%d ' -8rctu y Savo' 0.0184 More than one FTSE-10/07 may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Rocky River Wastewater Treatment Plant (Mooresville) b. WWTP Facility Permit #: NC0046728 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD S.,:a014 0 0 i . s g0143 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD (Firm/Design) motri. n )1(ifyk-Ck0r �. SS pmcis Cry 'ap tgS Approx. Current Avg. Daily Flow, MGD b. bL9 III. Certification Statement: I, 54esvul C, H-t m 041 f1 , certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the routeto the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the hest available data. This certification applies to those items listed above in Sections I and II for which I am the responsible party. Signature of this form indicates acceptancgof this wastew- - r ow. Signing Official Signature Date =i� u4t't c.I4tkN• ---(3 rir' lti �, c� l-eS, hoL .. e t\1 C, � `-i, -/4YL ¶ Ob (\1P+f 1 Dear Mr./Mg. kfe i (1 : Michael F. Easley, Governor William G. Ross Jr., Secretary Nonh Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality trYtab, a /a'2008 ec Subject: Fast Track,Applic:t on ' et o Pro'tName: 1 1ciaQLt r��.kr Z-4• J2tLr ,IL County, North Carolina The Divi ion of Water Quality, Mooresville 1 application on 11 11,41n. During an initial review of be incomplete. Therefore, your application is being rl your resubmittal). For a listing of the correct forms http://h2o.enr.state.nc.us/peres/CollectionSYstems/Cot Post -its Fax Note 7671 Date NA,.NA,.s� To �y r.�_ From 47 � b i CoJDept. Co. iy• Id e Phone # Phone # Fax # D ul ^ 5D j c .-14ax # Please complete/correct the following deficiencies: ❑ Application submitted on wrong or outdated forms. Form(s): Application was submitted without a processing fee or with an incorrect processing fee. Application did not contain a Flow Tracking Form (FTSE 10/07). . Application did not contain the Developer's/Homeowner's Operational. Agreement. Application did not contain the correct number of copies. • ❑ Application failed to include project map. ❑ Application (line A.lb) was not signed by an authorized representative in accordance with 15A NCAC 2T .0106(b). (see http:/1h2o_enr.state.nc.us/adminlruleslcodes statutes.htni) Following submission of a complete application, the Mooresville Regional Office will begin a technical review of your application. If your application is technically deficient additional information may be required or the package may be returned again. Sincerely, hryli &_7 • Robert B. Krebs Supervisor, Mooresville Regional Office Enclosure: Fast Track Sewer Extension Application cc: RO File S:\shelldoc\Fast Track Retum 3_08 610 East Center Ave. Suite 300 Mooresville, NC 28115 704-663-1699 (Telephone) _ North Carolina Secretary of State Page 1 of I North Carolina Elaine F. Marshal! DEPARTMENT OF THE Secretary SECRETARY OF STATE PO Box 29622 Raleigh, NC 27626-9622 (919j807-2000 CORPORATIONS Corporations Home Search By Corporate Name Search For New Corporation Search By Registered Agent Important Notice Corporations FAQ Homeowners' Association FAQ Tobacco Manufacturers Unincorporated Non -Profits Dissolution Reports Non -Profit Reports Verify Certification Online Annual Reports LINKS & LEGISLATION KBBE 82B Annual Reports SOSID Number Correction 2001 Bill Summaries 1999 Senate Bills Annual Reports 1997 Corporations 1997 Register for E-Procurement Dept. of Revenue ONLINE ORDERS Start An Order New Payment Procedures CONTACT US Corporations Division TOOLS Secretary of State Home Secretary of State Site Map Printable Page Date: 1/9/2009 Click here to: View Document Filings I Sign Up for E-Notiflcations I %Print apre-populated Annual Report Form I Annual Report Count I File an Annual Report I Corporation Names Name Name Type NC PRIMAX PROPERTIES, Legal LLC Limited Liability Company Information SOSID: Status: Date Formed: Citizenship: State of Inc.: Duration: Registered Agent 0382061 Current -Active 11/15/1995 Domestic NC DEC 2045 Agent Name: Seymour,. William G Registered Office Address: 1065 East Morehead Street, 4th Floor Charlotte NC 28204-2812 Registered Mailing 1065 East Morehead Street, 4th Floor Address: Charlotte NC 28204-2812 Principal Office Address: 1065 East Morehead Street, 4th Floor Charlotte NC 28204-2812 Principal Mailing Address: 1065 East Morehead Street, 4th Floor Charlotte NC 28204-2812 http://www.secretary.state.nc.us/corporations/Corp. aspx?PitemId=49613 59 1/9/2009 I Central Files: APS SWP_ 02/10/09 Permit Number WQ0033733 Permit Tracking Slip Program Category Non -discharge Status Project Type in review New Project Permit Type Fast Track Version Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Extensions Primary Reviewer dee.browder Permitted Flow 1118 Facility Facility Name Rite Aid Brawley School Road Location Address Owner Permit Classification individual Permit Contact Affiliation Major/Minor Region Minor Mooresville County iredell Facility Contact Affiliation Owner Name Owner Type Primax Properties Non -Government Owner Affiliation Robert Neill, Jr, Director Project 1115 E Morehead St Charlotte NC 28204 Dates/Events Scheduled orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 02/11/09 01/08/09 02/11/09 02/11/09 Regulated Activities Re ues ed/R c ived Events Retail Additional information requested 02/02/09 Wastewater collection Additional information received 02/02/09 Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin