Loading...
HomeMy WebLinkAboutWQ0032995_Regional Office Historical File Pre 2018Michael 1°. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural. Resources Coleen tt. Sullins, Director Division of Water Quality October 17, 2008 Mr. Mick W. Berry, City 1" Tanager City of Hickory P.O. Box 398 Hickory, North Carolina 28603 SUBJECT: Permit No. WQ0032995 City of Hickory River Oaks at Lake Norman lredell. County Low Pressure Sewer System Dear Mr. Berry: In accordance with your permit application received. April 24, 2008, and additional information received by the Division of Water Quality (Division), we are forwarding herewith Permit No. WQ0032995 dated October 17, 2008, to the City of Hickory for the construction and operation of the subject wastewater collection system. This Permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the approved plans and specifications. Mail the Certification to the Construction Grants & Loans Section, 1633 Mail. Service Center, Raleigh, North Carolina 27699-1633. (Engineer's Certification Form is attached.) One set of approved plans and specifications is being forwarded to you. NorihC'ardina ,Naturally North Carolina. Division of Water Quality 1617 Mail Service Center Raleigh„ NC 27699-1617 Phone (919) 733-7015 Custotner Service Irate• tel: wv .nc at etgrsaiity.orq, 512 N, Salisbury St. Raleigh, NC 27604 FAX (919) 733-2496 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 50% Recyciedll0% Post Consumer Paper Mr. Mick W. Berry, City Manager October 17, 2008 Page 2 If you need additional information concerning this matter, please contact Steve Coffey, P.E., State Review Engineer, at (919) 715-6222 or Seth Robertson, P.E. at (919) 715-6206. swclsr cc: Sincerely, Coleen H. Su: ins Cecil Clark, P.E., Clark & Associates, Inc., P.O. Box 2945, Hickory, NC 28603 Iredell County Health Department Mooresville Regional Office, Surface Water Protection (NC0025542) Seth Robertson, P.E. Daniel M. Blaisdell, P.E. Steve Coffey, P.E. Permit Application File WQ0032995 I NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO City of Hickory Iredell County FOR THE construction and operation of a pressure sewer collection system consisting of: approximately 3,052 linear feet of 2-inch pressure sewer pipe; approximately 2,441 linear feet of 2.5-inch pressure sewer pipe; approximately 2,683 linear feet of 3-inch pressure sewer pipe; 133 simplex grinder pump stations with on -site audible and visual high water alarms, to serve 133 single family residential homes as a part of the River Oaks at Lake Norman Subdivision; and the discharge of 47,880 GPD of collected wastewater into the City of Hickory WWTP (NC0025542) sewerage system pursuant to the application received on April 24, 2008, and subsequent additional information received by the Division, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0400. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0400: City of Hickory October 17, 2008 Permit No. WQ0032995 Page 2 (a) The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. (b) A map of the sewer system shall be developed and actively maintained. (c) An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response shall be developed and implemented. (d) Pump stations that are not connected to a telemetry system (i.e., remote alarm system) shall be inspected by the permittee or its representative every day (Le., 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. (e) High -priority sewers shall be inspected by the permittee or its representative at least once every six -months and inspections are documented. (1) A general. observation by the permittee or its representative of the entire sewer system shall be conducted at leastonce per year. (g) Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 02B .0506(a)„ and public notice shall be provided as required by G.S. 143-215.1.C. A Grease Control Program shall be established as follows: (i) For publicly owned collection systems, the Grease Control Program shall include at least bi-annual distribution of educational materials for both ,commercial and residential users and the legal means to require grease interceptors for new construction and retrofit, if necessary, of grease interceptors at existing establishments, The plan shaft also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. For privately owned collection systems, the Grease Control. Program shall include at least bi-annual distribution of grease education .materials to users of the collection system by the permittee or its representative, (iii) Grease education materials shall he distributed more often than required in Parts (i) and (ii) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. (i) Right-of-ways and easements shall he maintained in the full easement width for personnel and equipment accessibility. (j) 'Documentation shall be kept for Subparagraphs (a) through (i) for a minimum of .three years with exception of the map, which shall be maintained for the life of the system. 4. The sewage and wastewater collected by this system shall be treated in the City of Hickory WWTF (NC0025542) sewerage discharged into the receiving stream. r 5. 6. Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. Mail the Certification to the Construction Grants & Loans Section, 1633 Mail Service Center, Raleigh, North Carolina 27699-1633. (Engineer's Certification Form is attached.) 9. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 10. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (i.e., local, state, and federal) having jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, soil erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. The Permittee shall provide for the pump station and force main the foliowing items: (a) Pump Station Reliability: (i) Pump stations, except when exempted by Subparagraph (j)(2) of 15A NCAC 02T.0305, shall be designed with multiple pumps such that peak flow can be pumped with the largest pump out of service. (ii) A standby power source or pump is required at all pump stations except for those pump stations subject to Subparagraph (j)(2) of 15A NCAC 02T.0305. Controls shall be provided to automatically activate the standby source and signal an alarm condition. City of Hickory October 1.7, 2008 Permit No. WQ0032995 Page 4 (iii) As an alternative to Part (ii) for pump stations with an average daily design flow less than 15,000 gallons per day as calculated using 1.5A NCAC 02T.011.4„ a portable power source or pumping capability may be utilized. It shall be demonstrated to the Division that the portable source is owned or contracted by the permittee and is compatible with the station. If the portable power source or pump is d.edicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timefra.mes, shall be provided in the case of a multiple station power outage. (iv) As an alternative to Part (11) for pump or vacuum stations connecting a single building to an alternative sewer system, wet well storage requirements shall be documented to provide 24-hours worth of wastewater storage or, exceed the greatest power outage over the last three years or the documented response time to replace a failed pump, whichever is greater. .Documentation shall be required pursuant to the permit application. (v) All pump stations designed for two pumps or more shall have a telemetry system to provide remote notification of a problem condition to include power failure and high water alarm. (vi) High water audio and visual alarm. (b) Pump stations shall have a permanent weatherproof sign stating the pump station. identifier, 24-hour emergency number and instructions to callin case of emergency. Simplex pump or vacuum stations serving a single-family residence shall have a placard or sticker placed inside the control panel with a 24-hour emergency contact number. (c) Screened vents for all wet wells. (d) The public shall be restricted access to the site and equipment (e) Air relief valves shall be provided at all high points along force mains where the vertical distance exceeds ten feet. 12. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those that may be required. by this Division, such as theconstruction of additional or replacementwastewater collection facilities. 13. The facilities shall be constructed in accordance with the .requirements ofthe North Car Sedimentation Pollution Control Act. 14. if applicable, the Operational Agreement between the Permittee .and the Environmental Management Commission is incorporated herein by reference and is made a condition of this Permit. Noncompliance with the terms of the Operational Agreement may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. A copy of the Articles of Incorporation, Declarations, and Bylaws that have been properly 'filed shall be submitted with the engineer's certification prior to operation. r 15 16. Noncompliance Notification: The Permittee shall verbally report to a water quality staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of either of the following: ' (a) Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater transport such as mechanical or electrical failures of pumps, line blockage or breakage, etc. (b) Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858- 0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Per Condition I(2), Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 17. The Permittee shall maintain on hand for immediate installation a supply of spare, fully operational pump units of each type used in the pressure sewer system. The number of pumps on hand shall not be less than 10 percent of the number of installed units or one unit, whichever is greater. 18. No flow shall be made tributary from the subject sewer system permitted herein until the receiving downstream sewer (WQ0032152) has been constructed and the engineer's certification has been received by the Division of Water Quality. Permit issued this the 17th Day of October 2008 NO CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION � M. /5 trAl— Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit No. WQ0032995 City of Hickory Permit No. WQ0032995 River Oaks at Lake Norman Issued October 17, 2008 ENGINEER'S CERTIFICATION as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the low pressure sewer collection system serving the River Oaks at Lake Norman Subdivision, located in Iredell County, hereby state that to the best of my abilities, due care and diligence was used in the observation of the following: construction and operation of a pressure sewer collection system consisting of: approximately 3,052 linear feet of 2-inch pressure sewer pipe; approximately 2,441 linear feet of 2.5-inch pressure sewer pipe; approximately 2,683 linear feet of 3-inch pressure sewer pipe; 133 simplex grinder pump stations with on -site audible and visual high water alarms, to•serve 133 single family residential homes as a part of the River Oaks at Lake Norman Subdivision, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. I certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and specifications. Signature Registration No. Date Mail this Certification to: DENR/DWQ Construction Grants & Loans Section 1633 Mail Service Center Raleigh, North Carolina 27699-1633. SEAL Note: If the wastewater collection permit was issued to a private entity under an Operational Agreement with the Environmental Management Commission, then a copy of the Articles of Incorporation, Declarations, and Bylaws that have been properly filed with the applicable County's Register of Deeds shall be submitted with this certification. Nort July I, 2008 Mr. Mick W. Berry, City Manager City of Hickory P.O. Box 398 Hickory, North Carolina 28603 Michael F, Easley, Governor Uliant G,Ross Jr., Secretary NC DENR MRO DWQ-Surface Wafer Prof tlan SUBJECT: Request for Additional inforn°tation Permit No, WWQ0032995 Gravity and Low Pressure Sewer System River Oaks at Lake Norman Iredell County Dear Mr. Berry: A review of the plans and specifications in support of the petit application package has been completed by the Construction Grants and Loans Section (CG&L). The comments resulting from this review are being transmitted directly to your engineer' for clarification and resolution; a copy is attached for your reference. Our goal is to issue the Wastewater Collection Permit as soon as possible. If a complete response is not received within 30 days, the application and supporting information will be returned. Upon receipt of satisfactory responses from your engineer to our comments, the review of the plan documents will be completed. If you have any questions concerning this matter, please do not hesitate to contact Steve Coffey, P.E., State Project Review Engineer, at (919) '715-6222. Sincerely, Ken Pohlig, P.B., Acting Supervisor Construction Grants and Loans Section Design Management Unit sc/d:r Attachment to all cc: G. Cecil Clark, P.E. — Clark & Ass( ci rtes, Inc.., P.O. Box 2945, Hickory, NC 28603 Mooresville Regional Office (Permit NC{){.125542) Daniel Blaisdell, P.F. Steve Coffey, P.C. Permit Application File No: WQ01)32995 Construction Grants and Loans Section 1633 Mail Service Center Raleigh NC 27699-1633 Phone: 919-733-69001 FAX: 919-715-6229 / Internet: www,nccgt,net One North Caro la Vatura/4i An Equal Ooportunity/Affirmative Action Ern lover -- 50% Recvcled/10% Post Consumer Paper Construction Grants & Loans Section Design Management Unit Town of Hickory River Oaks at Lake Norman Permit No. WQ0032995 Request for Additional Information General Comments 1. Please reference the subject modified Permit Application No. WQ0032995 when providing the requested information. 2. Provide two copies of all revised plans, specifications, and/or additional documentation. Specific Comments 1. Provide a legend on the plans for sheet 1. Show gravity sewers on page 1. 2. On the plans include a table showing each lot, top of wet well elevation, pump elevation, TDH, pump model and impeller used. 3. Include plan and profile drawings and project details for Bluewater Drive and Pier Drive. Provide a copy of the permit for the I5-inch gravity sewer main. Show in the plans and details the connection(s) to the 15-inch gravity sewer main. 4. A large number of lots on the West side of the development will be totally submerged by the 100-year flood. AIso veryify that a minimum of two feet protection from a 100-year flood shall be provided unless there is a water -tight seal on all station hatches and manholes with vents and electrical control panels extending 2 feet above the 100-year flood elevation (15A NCAC 02t .0305). Show on the plans details of wet well venting for lots in the 100-year floodplain. If the wet well elevations are 2 feet above the 100- year flood elevation, it is recommended that pumps be vented from a punch -out on the side of the pump tank and not the lateral to the dwelling. 5. For Perch Court and Starboard Lane, reconcile the difference in total number of pumps between the summary and the listing by lot. The summary table shows 15 pumps and the listing by lot shows 13 pumps. 6. All sewers and pumps must be placed a minimum of 50 feet from wetlands and surface waters. Provide proper certification for stream crossings. 7. Show water mains on plans and be sure to maintain required separation as required in 15A NCAC 02T .0305. 8. Provide gravity segments and manholes to be included in the project in table form. 9. Provide details for pipe bedding in plans and specifications. 10. Provide drop manhole details on plans where the difference in elevation in gravity sewers is greater than 2.5 feet.. Show reducers on plan and profile drawings. 11. Provide air release valves at high points in force mains where elevation changes exceed 10 feet.. 1.2. Specify the pump and pump model to be used and show these on the plans and specifications. Plot the low and high head scenarios for each pump curve. 13. Provide a complete line diagram from this project to the WWTP to include downstream sewers and verify both system capacity and pressure compatibility. 14. Your application documented three years of electrical power reliability statistics with a single power outage event. 'How long was the power out for the single event? Provide this in a letter from the power company. 15. Please provide an electrical schematic for pump controls. 16. When the permit is issued, the owner of the permit must demonstrate 10% spare parts on site or 14 pumps (135 x 0.1 = 13.5 round up to 14). 17. Show hook and chain or pump motor harness detail for pump removal on the plans. 18. Show an electrical schematic and audible pump alarms on the electrical plan detail.