Loading...
HomeMy WebLinkAboutWQ0032917_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality April 23, 2008 Mr. Rob Jackson, Construction Manager Iredell-Statesville Schools 549 Race Street Statesville, NC 28687 Subject: Permit No. WQ0032917 Elementary School Wastewater Collection System Extension Iredell County, North Carolina Dear Mr. Jackson, In accordance with your application received on April 9, 2008, we are forwarding herewith Permit No. WQ0032917, dated April 23, 2008, to the Iredell-Statesville Schools for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15ANCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 Paper N r hCarolina 7aturrr!!j Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 An Equal OppartunityJAttirmative Action Employer-50% Recycled/10% Post Consumer Mr. Smith Page 2 ApriI23, 2008 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 750 linear feet of 2.5 inch force main and the discharge of 868 gallons per day of domestic wastewater in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Town of Mooresville Rocky River WWTP (NPDES Permit No. NC0046728) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of the Town of Mooresville. Mooresville must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the collection system permit WQCS00043. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files Stuart Little, Timmons Group Erskin Smith, Town of Mooresville Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's • (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and: public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there_ is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass `directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall: file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 23rd day of April 2008. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032917 3• r'ast Track Engineering Certification Permit No. WQ0032927 April 23, 2008 OwneriWQCS Owner,WQCS/WWTP Rob Jackson, Construction Manager Erskine Smith, Interim Town Manager Iredell Statesville Schools Town of Mooresville 549 N. Race Street PO Box 878 Statesville, NC 28687 Mooresville, NC 28115 PE Stuart Little Timmons Group 1001 Boulders Parkway,Ste 300 Richmond, VA 23225 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • - Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete•nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ['full time) the construction of Elementary School, an Iredell County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner/Permittee: Iredell — Statesville Schools Full Legal Name (company, municipality, HOA, utility, etc) Application Number: (to be completed by DWG) • 1 b. Rob Jackson, Construction Manager µu _ Signing Official Name and Title Please review 15A NCAC 2T .01t'D6 (b) lc. The legal entity who will own this system is: Public School System ❑ Individual ❑ Federal ❑ Municipality ❑ State/County 0 Private Partnership 0 Corporation O l d, 549 N. Race Street LL. Mailing Address lf, North Carolina. State O 1 h. 704-924-2036 Telephone 0 LL. z Facsimile 2_ Project (Facility) Information: 2a. Elementary School Brief Project Name (permit will refer to this name) 3. Contact Person: 3a, Frank Slinsky / Civil Engineer Name and Affiiliation of Someone Who Can Answer Questions About this Application 3b, 919-866-4934 3cfrankslinks le. Statesville for authorized signing officials!) Other (specify). City 1g, 28687 Zip Code 1j. 'ackson iss.k12.nc.us E-mai 2b. Iredell County Where Project is Located Phone Number Project is b'u New edification (of an existing permit) 2. fawner is ❑ Public (skip to Item B(3)) Private 2a. If private, applicant will be: Retaining Ownership (i,e. store, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Selling units (lots, townhomes, etc - go to item B(2b)) E-mai edification, Permit No.: go to Item 2(a)) 2b, if sold, facilities owned by a (must choose one) Public Utility (Instruction C) ❑ Homeowner Assoc./Developer (Inetr +ction D) 3. Town of Mooresville__ Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a, Rocky River WWTP Name of WWTF 4b. NC0046728_ WWTF Permit No, 5a. Town of Mooresville 5b. 8° Gravity 5c. Owner of Downstream Sewer Receiving Sewer Size ❑ Force Main 6. The origin of this wastewater is (check all that apply): • Residential Subdivision Ej Apartments/Condominiums O Mobile Home Park. 0 School 0 Restaurant Office ❑ Retail (Stores, shopping 0 Institution Hospital ❑ Church Nursing Home Other (specify); Canoe_s Restrooms sion Stand/ Permit # of Downstream Sewer (Instruction E) centers) 100 % Domestic/Commercial 9/0 Industrial (attach description) (RO: contact your Regional Office Pretreatment staff) °l° Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project. 868 gallons per day *Do not include future Flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: O Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line O Flow has alreadybeen allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T ,0303 to determine if a permit is required) FTA 1.2/t17_v ' I9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 1,736 SF Concession Stand x 50 gpd/100 SF = 868 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main 2-1/2" 750 Force Main 0 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) W p .. Pump Station Location ID SEW 10 of PS (self chosen - as shown on planslmap for reference) Z Z O Design Flow (MGD) OperationalPoint GPM @TDH Power Reliability Option 1 - permanent generator wIATS; 2 - portable generator wlMTS Force Main Size Force Main Length V 0.043 30 gpm @ 30 TDH Single Line Feed; PS will not be in used Himinn nn+wPrfaniIrv. 2'1/2" 750 Z 0 Station Location ID (self chosen - as shown on planslmap for reference) QPump 2 Et LL Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generatorwlATS; 2 - portable generator w/MTS Force Main Size Force Main Length Z H cPump Station Location ID (self chosen - as shown on planslmap for reference) dDesign m Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; 2 - portable generator w1MTS Force Main Size Force Main Length 12. ■ Will Yes the 0 wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? No If Yes, permit number of 2nd treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does Mains applicable? ►� the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as Yes • No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA12/07_ver2 '14: Have the following permits/certifications been submitted for approval for the system or project to be served? Welland/Stream Crossings - General Permit or 401Certification? El Yes El No ,E1 N/A Sedimentation and Erosion Control Plan? I Yes LI No El NIA Stormwater? El Yes D No Ei N/A 45_ Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)) involve aerial lines, siphons, or interference manholes)? Theselines will be considered hioh- priority and must be checked once- eVel-iisix months .Checklf Yes: El and provide details i. OWner/Permittee's,Certification: (Signature &Signing Official and Project Name) -*"- ii9c1:44Wia attest that this application foiC•OA1-14.1.2icAi.t.e..- gegot, has been revre •by me and is accurate and complete fo the best of my knowledge. 1 Onderstand.that hall required parts of this application are not completed and that if all required supporting documentation and attiachipelifteiCtiOrinalgded, this application package h:60bject to being returned as inComplete. Note: fn 'accorrianciOtfookA40)30-0179p.4 Statutes 143-215.6A and 143-2166B, anyperson who knowingly makes any false staternegetVgeSet4affigli or certifiaatiOniii any applkation shall be guilt)i o f a Class 2 misdemeanor, which rnakincludike fine ncifteeiceed $10,000 as well as civil pertakes up 'tic) $25,000 per violation. Signing Official) :' griaflir#, - • . - • 'Date '.ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE 2F...$pAiRsiTHEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC B2T 0305 :0 .2. Professio I Engineer' ertification: ,(Signature of Design Eng ineer and. Prdiept Name) attest that this application for pArile.. OSO4, •5101 • hes been LL reviewed by end is accurate complete and consistent with the in orniation in the engineeringplarii,7deladlations, and all other4fr pditing:docamentation to the bed of My knowledge. further attest that to Vie best etmy knowledge the proposed design has been prepared ln accordance with the applicable.regulations, Gravity Sewer Minimum Design Criteria for Gravity.Sewert adopted February 12 1995; and the Minimum DesignCriterfalor forthe Fast -Track Permitting or Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification 111'de-ow:dance With.Diviaion guidance. Although other professionals mayhave developed certain portions of this submittal peckage,,inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NO General Statutes 143-216,6A and443-0.5.K any who knowingly makes any false Statement, representation, or certification in any application:shell be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up fo s25,000per vidatioq. !2a. Stuart Little Professional Engineer Name 2b. Tfmmons.Group - Engiraerrngfr nr-if ttttttt Ili ‘ ttt 1 f Nt' NA CAP? .. . ... 4., 440, .... ....... .. / . 0.,.. ' 1. .:.• (-5•-.•4 10 XI,. -:,. --- ' - .• - .. — ' - 2c.. 1001,Boulders Parkway, Suite.300 - • ▪ • • • 7:0 • ▪ S 2cI. Richmond VA 2f. 23225 „ e•.„. • • ..... • .„„..c‘," . . State "i1/41/11RT NC PE Seaf..„;ligtUr.:.,8,, Date -804,200,6508 8045.60-Stuartstuart.httle@tanmons.com .1018. TelePliOne. FEanille E-mail FTAI2/07 yer'2 4. Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No N/A Sedimentation and Erosion Control Plan? Yes ❑ No ❑ N/A Stormwater? ❑ Yes 0 No N/A 15. Does this project include any high priority lines, [see 15A, NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details Owner/Perrrsittee"s Certification: (Signature of Signing Official and Project Name) ' , attest that this application for CO 04 C'rte•C has been reviewc.dy by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation.. Date Signing Official fgrrature ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMI i IAL OF THIS APPLICATION, THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T .0305 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) f, attest that this application for ,., has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC Genera/ Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $ill, 000 as well as civil penalties up to $25, 000 per violation, 2a. Stuart Little Professional Engineer Name 2b. Timmons Group Engineering Firm 2c, 1001 Boulders Parkway, Suite 300 Mailing Address 2d. Richmond City 2e, VA 2f. 23225 State Zip 2g. 804 2©a-65O8 mn 2t1. f14-5S0-1016 2i, stuart.little er timmons.com Telephone Facsi ilIIe E-mail NC PE Seal, Signature FTA12/07 ver2 FIRST MARKET BANK • ••••• TIMMONS GROUP, INC. RICHMMO68-� D,'�V5 0 230 •• 1001, BOULDERS PARKWAY, SUITE 300 , RICHMOND, VA 23225 CHECK DATE TIMMONS GROUP (soa, Zoo-ssoo PAY Four Hundred Eighty and 00/100 Dollars TO NCDENR 1 61961 February 13, 2008 Mao on tack. 8 AMOUNT $480.00 NP 4 00611961v 1:05L0740301: 40LL2726?31I' 4A�F9 State of North Carolina QG Department of Environment and Natural Resources r Division of Water Quality -c Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE —10/07) Project Applicant Name: Town of Mooresville Project Name for which flow is being requested: j r,l l - Ccx3�}lc- reek- L)4r` ) More than one FTSE l0/07 may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Rocky River Wastewater Treatment Plant (Mooresville) b. WWTP Facility Permit #: NC0046728 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 5. ac)CD cD , afs> L1 . 4t9 q %„ II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. A- A rSo� 1-) v�cZ7a.rro> , cc_r-m car ) - List pump stations located between the project connection point and the WWTP rr1 eC� `r`'1' c-r--r-Kv-1-15 Pump Station Name Approx. Capacity, MGD Approx. Current Avg. °r-nov; .l- (Firm/Design) Daily Flow, MGD ��"```� q�r-c�., � w or 13 cT )rY p, r C`)t�[.}xrse 'L'cQ W:.TtP) III. Certification Statement: I, Fr ei /711- , certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local establish: • po 'cies and procedures using the best available data. This certification applies to those items listed .'•ve n Sections I ? d for . hick I am the responsible party. Signature of this form indicates accep ee % this Ater ' { ,f76e? Signing I facial Signatur I Date PTOWN OF MOORESVILLE PUNNING & ENGINEERING DEPARTMENT . • . •. ........... • . - • ........ 4.-,--,-.7' • A 47 . P.: ,,r,.: ,....1,--.. - March 5 2008 _., •"''. -!:...,.1-; 4. '-,:: #1' z- Mr. FranleSlinsky-/ Timmons GroAlp „..4-' .1,v 'I, .,, .,. e• 4. Vi; 'C.:$' „, •"4 . ..... .,- 1001/BouldiriParkway, Suite 300 ....... ., . ... ,.. •-• 1/4,_ , „, .,,..,:, • ,;„ , ,...., , Richmond -VA 23225 4-T rts,-. rl .5.,,9- ,,,, - p...,_ .... _ ,, v. . r , .4,-, ......i :,..,,'- V,:.... ,.. ..=.1 . Re: ,Plredelf-Sta tesville Schools ''''.."I''' -P.,,,,', -,-v :.) -r- —r- J...., --4.1. r•=7%..... g' 17 ".";...';''''' '1.7 .. . :t ci t..) -41 . 4C4 '- Coddle Creek Elementary Schoorind:CdrieeSSidif'Statid- ' .-.' .-2.1:',' ---.' r 7 -':, *:—..4-- . t* if. Flow Acceptance Letter ',•-, \Ay-. - 2 )) • "..1., kez?'--6' ..;,- .r.:,. ''t•";...' -'7'." 4) .11 § Mr. Timmons: „:„... 1 ...,., \ 7.:,...,,,i'.7.:1, ,,...,,;..4„.2,.,:7:_r,....;- er .,...- .3 ' ‘_., 4,1 ''..--,,z,::\ ',,,-"-,•>,,,',4e-k- .......'„'..'.'''' .V,.\ st .. , '--- t.1 • - . -- , - h. tr,i , . The Town of Mooresville agrees':tO_„--acaeptthe sewerllow frOrri the above referenced -.1. ,s . _.,,,-. .. -,-_,, 4... ..„_.-,. project Wastewater will be teate$1,,byithe Town of Modresville's Rocky River VVVVT,P,_ei 4 NPDES Perrnft No. NC064672-6,17hie- evelopment's expected input into the INWTRIS 4' t16,993 gpd based on the following: ' 1 i I ;1.', S, • :.. .:-4 c: \ 950 students + 125 faculty x 15 gpd/perSOtt46;125.gPd 15, 1,736 sf Concession Stand x 50 gpd/100:st .7186,..,.gpd ,,f,,i, jc,?.. Allison B. Kraft, PE Civil Engineer Town of Mooresville P. Q. Box 878 Mooresville, NC 28115 (704) 799-4066 Fax 662-7039 ( • el 4'5> t%.. in, .t.'• ' It isyour resp-oribibility, as the engineer of record, to:CertifyIP-the Town and tothe §tateithat consfiuctierOfis been completed in accordance l 'With the approved plans and iSPecifications. sz. ,,,- _.- ,, • vc.% ,4 .t -'........! ..'.' '2..i _. .. 4.-..,._' We look forward to working with you onthis project. oy ,07 •Vj Q26'.! 11: Sincerely, t .., , ,,.., .„, ...1,-. - Allison B. Kraft, PE, Civil Engineer 1 CC: Cliff Webb \ N5° 31 .t i 035' 32 BARNES www.cranepumps.com Series SGVF Performance Curve 2HP, 3450RPM, 60Hz, High -Flow TOTAL ' HEAD METERS FEET 30 — 100 25 — 80 20 — 60 • 15 — 40 :- 10- 20 .U.S.GALLONS PER MINUTE Submersible Grinder Pumps inches (min) 5,127 �O=1411 — u,ffa 600 00 (127 ' ra■■ 4.50 (114)lib _1111111M11112 l__ MIIIIE ■ —yaw_____C� � 4.00 (102)iliNiiiiallib. 'eb► Ii;;IuII.I.:l,u Iiiinats ItlinI.:!R♦pagl! ,I a►ll _ 3.50 (89) ��II �' r1l!1Mir �1 325 83 1PP 11 ■101����11f�► IAA1111111 Al IIP a6211.111310011 STANDARD IMPELLER SIZES 1 LITERS PER SECOND CRAN E. .6 Pump HP Impeller Dia. 2.0 5.13 (130) 10 20 30 40 V110614 50 60 1 1.5 2 2.5 3 3.5 Testing Is performed with water, specific gravity 1.04 68° F ® (20°C), other fluids may vary performance PUMPS & SYSTEMS ACaine .CO. Company USA: (937) 778-8947 • Canada: (905)-457-6223 • International: (937) 815-3598 1 SEC'flON 3B PAGE 5 DATE 11103 a 0 n Q T•O' OyyPgEPNe`��ie9it�elr.0e0imm1`momiCr CD'S "3 Pl"e o•O-m cIInmpf 9 aE MA0.e,-{0IA A Nrn } 0 O e? O OO O o 0 0 0 0 0 0 0 0 0 0 0 0 0 10 g e$ Q Jo a a C ppb �1tl!{� 999c,9999999999 t/� pp 01(f 1y�1 m 1{, .. NIV e7 Q in t0 CO i0 r•P. W CCe Co r,,, i O C C110m32fD4Y211mr{gmfefaqq.. mm,mmr.-.-- 04 reO-rNNNNOIe'Ie7QQRs h n01f1'pegpp {0y 1f11��; 01i 0Jeom �2eRy4 stD z 05 .Fv j0ooC ° m wCf ggto,,gg. e'S m 822232n°ovom4Zg24ggvorm CO ar 1NgNl tl� 82y 90V pp 412 O 1tL xvv.?v,vvvvavvVVv gaagqvvvva PIPE DIAMETER SP r .-.-up R .-mnn.- up r r rrr- r 01 t-r r:r r+rfri rafk a ►-x CO w mmmmmco003 oaommmmmmmmmmwCOaom 2 IL Fkl i 111 Qr CDu7q PI PIv V grf�o in 47 In D.D P.A in W CO m m°C..-�� 6u1 o en CD p 1. OOP OOC7e70Geaae70 CN4 - a 5p0 C7 p I± V NI o 1, olc 0 el m M wI o 01 e4 N ee.l1m m Cu .4e4 a ry O eden4vui41 CT Cll 0. PI w et en ui Z FCCOgoa.N-eo`! ei0 6O�0 Co ooa g0g2.51-m1P.2 Oaupupup 4- Cal N '22 C30400 . 24ieanmc3PV-'-'2 al e!f'O r Ti, 00 1 in PE s'q • el G ety Leo.- �.-.- F 10 ef2 - co ep P.-.-r ed co e0 co r.-rcit CI t[3 coup o co rrrin in upup co as In r to u7 r rrrrrrrrr co co eta {(; eft eo a 6 A ,ti C4 C4 C4 C4 N N C4 C4 C4 C4 N N or N C4 C4 CV C4 C4 C4 C4 C4 C4 C4i0.1�9 a�� CO 000000aooaaoa00000000000 0 O. Orr Cc'1N q Ne0 S7mCYu]eenCO pp qq}} Cp ��Cef P. A u�f77 123, eu�1 0)O7'��6� x e 2e2m11012421101110i1e4w10ml24127110 rg..s.4ri r r- k7-,NNNm22g82.00 A 47 e001r gq co zp�j Ftr) 'zoo 8nw382enN ceidasr'4 _�ca04C Mv Lel P. �g 'ad i 0. 8e8ie8ivai$vaie8i$Y7u]tQi47e4efJe(7YSef7uleAe(2e822''8 r-1.nM1r.nr- A P. 1. P. r` P. P. r. r P.1• r` le.r- r. 1•n i ��ii Wg i Ec 0. s p T„ Heelu74� CV C4 es eeleghen41en00l0en0u741e CY CV C4 C4 C4 C4 C4 C4 of eV e4 .4 re CV � eneAeq N C4 C4 CV 2.5 25 to CI QW to o t, oe7go.001 - 1-t- oeyaOOooaoo . ppNmu,rr HOO O 2 m 0 OAoomg W �r--�! ra PS Olt CONCESSION STAND 5w head loss due to friction - ft. of liquid equivalent length of pipe friction factor Row of liquid (gallons per minute) average inside diameter orPie - Inches 9O"Bend= 45'Bend= Flush Conn.= 1.59c1.5T= 1.5" PV= 1.5"CV= L:1201%23881-CODDLE CREEILES1CalclSanTump Station CODDLE CREEK ELEMENTARY SCHOOL PUMP STATION CALCULATIONS PS (a) CONCESSION STAND H. d WIiil Input Output hp L= GPM= d= 90'Bend= 45'Bend= Flush Conn.= 25¢"T 2"PV= 2'CV= rmu head loss due to Mellon -fL of liquid equivalent length oPlpe friction factor flow of liquid (gallons per minute) average Inside diameter of pipe - inches Total Length of pipe (ft� Total L 41 • =length ofpip$ from PS to 2.5M7u TOTAL= PS fah CONCESSION STAND 2.5" Hazen and William Formula Input Output L= GPM= d= 9o"eend= 45"Bend= Flush Conn.= 2.5' t.5'T= 2.6' PV= 2.5"CV= heed loss due to Met* - fL of Iigsid equivalent length of pipe friction factor flaw of llgidd (gallons per rntnute) average Inside diameter of Acre - Inches RWEIR Ntrzni Total Length of pipe (ft� Total L length ofptoo tram 2PM to Mil 0 Total Dynamic Heat hr0.002083 L((1001C)M.85)"((DPM"1.85y(d"4.8855)) Static Head= Velocity Head (ht)= TDH= ft) 2/1412008 Central Files: APS SWP 04/22/08 Permit Number WQ0032917 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 868 Facility Facility Name MajorlMinor Region Elementary School Minor Mooresville Location Address Owner County Iredell Facility Contact Affiliation Owner Name Owner Type City of Statesville Government - Municipal Owner Affiliation Robert Hites, Jr Dates/Events PO Box 1111 Statesville NC 286871111 Orig Issue App Received 04/23/08 04/09/08 Regulated Activities Draft Initiated Scheduled Issuance Public Notice Issue Effective 04/23/08 04/23/08 Reuestedleceive. E e t School Additional information requested Wastewater collection Additional information received Outfall NULL Expiration Waterbody Name Stream Index Number Current Class Subbasin