HomeMy WebLinkAboutSWA000098_Plan (Cover)_20210405C - SERIES DRAWING ABBREVIATIONS:
ADV-ADVANCE
AFG - ABOVE FINISHED GRADE
APPR LOC. - APPROXIMATE LOCATION
ASS'Y - ASSEMBLY
B/C - BACK OF CURB.
B/L - BASE LINE
B/W - BOTTOM OF WALL
CBR - CALIFORNIA BEARING RATIO
CG - CURB AND GUTTER
C/L - CENTERLINE
CL - CLASS
CMP - CORRUGATED METAL PIPE
CO - CLEAN OUT
CONIC - CONCRETE
CONN- CONNECTION
CP - CORRUGATED PLASTIC
CY - CUBIC YARD
DI - DROP INLET
DIP - DUCTILE IRON PIPE
DR - DRIVE
DS - DOWNSPOUT
E - ELECTRIC
EA -EACH
E BOX - ELECTRICAL BOX
ELEC - ELECTRIC
E/P - EDGE OF PAVEMENT
E/S - EDGE OF SHOULDER
EX - EXISTING
F/C - FACE OF CURB
FDC - FIRE DEPARTMENT CONNECTION
FF - FINISHED FLOOR
FH - FIRE HYDRANT
F/L - FLOW LINE
FL - FIRE LANE
G - GAS
GND-GROUND
GTS - GAS TEST STATION
GV - GAS VALVE
HDPE - HIGH DENSITY POLYETHYLENE
HORIZ - HORIZONTAL
INV - INVERT
LF - LINEAR FEET
MECH - MECHANICAL
MH - MANHOLE
MIN - MINIMUM
MIN S - MINIMUM SLOPE
MJ - MECHANICAL JOINT
NIC - NOT IN CONTRACT
LEGEND
SEWER
OHE - OVERHEAD ELECTRIC
OHP- OVERHEAD POWER
OHT - OVERHEAD TELEPHONE
PB - PLAT BOOK
PC - POINT OF CURVATURE
PED - PEDESTAL
PG - PAGE
PH -PHASE
PI - POINT OF INTERSECTION
PKG - PARKING
P/L - PROPERTY LINE
PT - POINT OF TANGENT
PP - POWER POLE
PVC - POLYVINYL CHLORIDE
PVMT- PAVEMENT
PWR-POWER
RD - ROOF DRAIN
RJ - RESTRAINED JOINT
R/W - RIGHT-OF-WAY
REQ'D - REQUIRED
RCP - REINFORCED CONCRETE PIPE
S - SLOPE
SAN - SANITARY SEWER
SDWK - SIDEWALK
SF - SILT FENCE
SPT - SPOT GRADE
SS - SANITARY SEWER CONNECTION
STA - STATION
STD - STANDARD
STM - STORM
STMH - STORM SEWER MANHOLE
T- TELEPHONE
TCM - TELECOMMUNICATIONS MANHOLE
T/C - TOP OF CURB
TEL - TELEPHONE
UGE - UNDERGROUND ELECTRIC
UNK-UNKNOWN
UP - UTILITY POLE
VAR - VARIABLE
VERT - VERTICAL
W/ - WITH
W/L - WATER LINE
W - WATER
WUS - WATERS OF THE US
X-ING - CROSSING
0 - DIAMETER
' ,'5AN --lllW�� --
.... EXISTING SANITARY SEWER
8"SAN
SANITARY SEWER
N 7605.80
SANITARY MANHOLE NUMBER
1
E 9378.25
W/ COORDINATE LOCATION
EX SANITARY MANHOLE
OS
SANITARY MANHOLE
6'J)
EXISTING CLEAN OUT
®
CLEAN OUT
WATER
811 V V ....
EXISTING WATERLINE
WATER LINE
8"W
EXISTING WATER VALVE
®
WATER VALVE
®
POST INDICATOR VALVE
EXISTING WATER METER
•
WATER METER
EXISTING FIRE HYDRANT
FIRE HYDRANT
1
WATER LINE REDUCER
8 VV ....
..... EX WATER LINE PLUG
WATER LINE PLUG
WATER LINE CROSS
i T i
WATER LINE TEE
'�
FIRE DEPT CONNECTION
o'
WATER SPIGOT
EXISTING WELL CASING
NATURAL GAS
EXISTING GAS METER
EXISTING GAS VALVE
EXISTING GAS LINE
GAS LINE
MISCELLANEOUS UTILITIES
WESLEY CHAPEL VOLUNTEER
FIRE STATION NO. 44
WEDDINGTON, NORTH CAROLINA
EXISTING LIGHT POLE
EXISTING YARD LIGHT
EXISTING GROUND LIGHT
❑- •-❑
LIGHT POLES
EXISTING UTILITY POLE
UTILITY POLE
EXISTING GUY WIRE
'?
EXISTING ELECTRIC METER
0", /P ...
EXISTING OVERHEAD ELECTRIC
OVERHEAD ELECTRIC
OHP
U(3/1" --
-- .... EX UNDERGROUND ELECT LINE
UNDERGROUND ELECTRIC LINE
UGP
LC`l
EXISTING TELEPHONE PEDESTAL
'
EXISTING TELEPHONE MANHOLE
0",'../ . ...
EX OVERHEAD TELEPHONE LINE
OHT
OVERHEAD TELEPHONE LINE
- - U(31
EX UNDERGROUND TELEPHONE LINE
UGT
UNDERGROUND TELEPHONE LINE
Oj:0. ........................
EX OVERHEAD FIBER OPTIC LINE
OFO
OVERHEAD FIBER OPTIC LINE
LU10
EX UNDERGROUND FIBER OPTIC LINE
UFO
UNDERGROUND FIBER OPTIC LINE
la
EX CABLE TV PEDESTAL
11 .... . ................... ...
............. - EX OVERHEAD CABLE TV LINE
OCATV
OVERHEAD CABLE TV LINE
l„MCA / .... ,.................
EX UNDERGROUND CABLE TV
UCATV
UNDERGROUND CABLE TV LINE
— UG P/C
COMBINED POWER/CATV
— UG P/T/C
COMBINED POWER TELE CATV
— UG P/T
COMBINED POWER, TELEPHONE
— UG T/C
COMBINED TELEPHONE, CATV
VICINITY MAP
NOT TO SCALE
SITE
STORM SEWER
• `J
EX DROP INLET
DROP INLET & STRUCTURE NUMBER
EXISTING STORM SEWER MANHOLE
STORM SEWER MANHOLE
09
EXISTING ROOF DRAIN DOWNSPOUT
®
ROOF DRAIN DOWNSPOUT
EXISTING CURB
CURB
EXISTING CURB & GUTTER
CURB & CUTTER
— —
PROPERTY LINE
DESCRIPTION
ELEVATION
BENCH MARK
APPROX BORING LOCATION
LIMITS OF CONSTRUCTION
.....,
EXISTING TREE LINE
CLEARING LIMITS
EXISTING SHRUB
EXISTING TREE
................. ..... >t..... .....
EXISTING FENCE
X
FENCE
G"(;k) ................... ............. ...................
EXISTING CONTOUR
200
CONTOUR
T/C E/P SWL
—95 .32 2
SPOT ELEVATION
C/LSWALE
EXISTING SIGN
—o—
SIGN
0
BOLLARD
EXISTING FLAG POLE
PROPERTY MARKER FOUND / ROD FOUND
PIPE FOUND
GENERAL NOTES:
1. SITE ADDRESS:
306 REID DAIRY ROAD, WEDDINGTON, NC 28173
2. ZONING: CONDITIONAL DISTRICT - WESLEY CHAPEL VOLUNTEER
FIRE DEPARTMENT
3. TOTAL SITE AREA: 1.718 ACRES
4. DISTURBED ACREAGE: 3.1 ACRES (INCLUDED SEWER
EXTENSION)
5. NEW BUILT UPON AREA: 32734 SF (0.75 AC)
6. USE: EMERGENCY SERVICE FACILITATORS (FIRE STATION)
7. PIN NUMBER: 06177015B
8. WATERSHED OVERLAY DISTRICT: NONE
9. FIRM: PANEL 371044660K DATED 3/2/2009
PARCEL IS LOCATED IN ZONE 'X' OF THE FEMA FLOOD
ZONE AND THE COMMUNITY FLOOD ZONE.
10. PARKING PROVIDED:
REGULAR = 20 SPACES
HANDICAP = 1 SPACES
TOTAL = 21 SPACES
PROPOSED USE
EMERGENCY SERVICE - FIRE STATION
REQUESTED METERS:
DOMESTIC WATER: 1 1/2" METER, 3/4" METER
IRRIGATION 3/4" METER
REQUESTED FLOW:
SUMMARY OF WATER MAINS AND FIRE HYDRANTS
PUBLIC WATERLINE MATERIALS
PRIVATE WATERLINE
MATERIALS
WATER MAIN
VALVES
REDUCERS
WATER MAIN
VALVES
SIZE
TYPE
LENGTH
SIZE
AMOUNT
SIZE
AMOUNT
SIZE
TYPE
LENGTH
SIZE
AMOUNT
6"
DIP
22 LF
6"
2
6" X 2"
1
6"
PVC
210 LF
1 1/2"
1
2
BRASS
5 LF
1 2"
1
1 6" X 3/4"
1
1 1/2"
PVC
152 LF
3/4"
BRASS
14
1 3/4"
2
3/4"
PVC
460
TOTAL NO. HYDRANTS: 1
DAILY FLOW REQUIREMENTS: FI RESTATION- 50 GAL/PERSON/SHIFT X 6 PERSON X 1 SHIFT = 50 X 6 X 1= 300 GAL/DAY
HOUSE- 400 GAL/DAY
IRRIGATION FLOW: 10,000 SF x 1/2" PER CYCLE x (1"/12') x 2 DAYS PER WEEK = 833 CF/WEEK x X 7.481GAL/CF X 1 WEEK/7 DAYS = 890.59 GPD
SUMMARY OF SEWER MAINS AND MANHOLES
SIZE
TYPE
LENGTH
8"
PVC
654 LF
8"
SDR-26
1026 LF
CLEANOUTS
TYPE
LENGTH
6" - 4
PVC
294 LF
4"-6
PVC
180 LF
TOTAL NO. MANHOLES: 7
TOTAL NO. LOTS SERVED: 2
DAILY FLOW REQUIREMENTS (RESIDENTIAL): 190 GAL/RESIDENCE = 1 RES =190 GAL/DAY
DAILY FLOW REQUIREMENTS (FIRE STATION): 50 GAL/PERSON/SHIFT = 6 PERSON X 50X 1SHIFT = 3000AL/DAY
DAILY FLOW REQUIREMENTS (TOTAL): 490 GAL/DAY
DRAWING INDEX
TITLE DRAWING
CIVIL COVER SHEET
C000
EXISTING CONDITIONS AND DEMOLITION PLAN
C100
SITE LAYOUT
C200
SIGHT DISTANCES - NORTH DRIVE
C201
SIGHT DISTANCES - SOUTH DRIVE
C202
VEHICLE TURNING MOVEMENTS
C203
OVERALL UTILITY PLAN
C204
UTILITY PLAN
C205
SANITARY SEWER PLAN PROFILE (STA 00+00 - 12+00)
C206
SANITARY SEWER PLAN AND PROFILE (STA 12+00 - 17+00)
C207
PHASE I EROSION CONTROL PLAN
C300
PHASE I EROSION CONTROL PLAN
C301
PHASE II EROSION CONTROL PLAN
C302
PHASE II EROSION CONTROL PLAN
C303
EROSION CONTROL NOTES AND DETAILS
C304
EROSION CONTROL NOTES AND DETAILS
C305
NCDEQ GROUND STABILIZATION & MATERIALS HANDLING
C306
NCDEQ SELF -INSPECTION, RECORDKEEPING, & REPORTING
C307
GRADING PLAN
C400
DRAINAGE AREA MAP
C401
STORM PROFILES
C402
PRE DEVELOPMENT DRAINAGE AREA MAP
C403
POST DEVELOPMENT DRAINAGE AREA MAP
C404
SITE NOTES AND DETAILS
C500
SITE NOTES AND DETAILS
C501
WATER AND SEWER NOTES AND DETAILS
C502
WATER AND SEWER NOTES AND DETAILS
C503
BMP NOTES AND MAINTENANCE PLAN
C504
LANDSCAPING PLAN
L100
LANDSCPAING NOTES AND DETAILS
L101
TOTAL DRAWINGS = 30
ARCHITECT
STEWART - COOPER - NEWELL ARCHITECTS
719 EAST SECOND AVE
GASTONIA, NORTH CAROLINA 28054
PHONE: (704) 865-6311
scn-architects.com
CIVIL/LANDSCAPE
TIMMONS GROUP
610 EAST MOREHEAD STREET, SUITE 250
CHARLOTTE, NORTH CAROLINA 28202
CONTACT: BRIAN CRUTCHFIELD
PHONE: (704) 376-1073
EMAIL: brian.crutchfield@timmons.com
OWNER
WESLEY CHAPEL VOLUNTEER FIRE DEPARTMENT, INC.
315 WAXHAW INDIAN TRAIL RD.
WAXHAW, NORTH CAROLINA 28173
CONTACT: STEVEN MCLENDON
PHONE: (704) 843-3367
EMAIL: smclendon@wesleychapelvfd.org
r
Know. w as'sel
Call 1 et om y
lign
I
II114'� Hi , io'�
GENERAL NOTES
ALL NOTES APPLY TO ALL DRAWINGS AND ALL TRADES. IT IS THE RESPONSIBILITY OF ALL CONTRACTORS AND TRADES
TO COORDINATE THE INSTALLATION OF THEIR WORK WITH THE INSTALLATION OF WORK BY ALL OTHER CONTRACTORS AND
TRADES. THE REQUIREMENTS OF THE DRAWINGS, GENERAL REQUIREMENTS AND ALL ITEMS OF THE CONTRACT DOCUMENTS
ARE EQUALLY BINDING ON ALL CONTRACTORS AND TRADES. EACH CONTRACTOR IS REQUIRED TO MAINTAIN FULL SETS
OF THE CONTRACT DOCUMENTS FOR HIS EMPLOYEES USE ON THE PROJECT TO ASSURE THAT ALL WORK IS PROPERLY
COORDINATED AND INSTALLED WITH THE WORK OF OTHER CONTRACTORS AND TRADES.
WHENEVER THERE ARE DISCREPANCIES BETWEEN DRAWINGS, OR BETWEEN THE DRAWINGS AND SPECIFICATIONS, OR
CONFLICTS WITHIN THE SPECIFICATIONS AND/OR DRAWINGS, AND SUCH DISCREPANCY IS NOT CALLED TO THE
ARCHITECT'S ATTENTION IN TIME TO PERMIT CLARIFICATION BY ADDENDUM, THE CONTRACTOR SHALL BASE HIS BID UPON
PROVIDING THE BETTER QUALITY OR GREATER OF WORK OR MATERIAL CALLED FOR, SHALL SUBMIT A WRITTEN STATEMENT
WITH HIS PROPOSAL NOTING SUCH DISCREPANCIES, AND SHALL SO FURNISH AND INSTALL SUCH BETTER QUALITY OR
GREATER QUANTITY UNLESS OTHERWISE ORDERED IN WRITING.
Project No.
1619
Date: 11.12.2020
Drawn by: JH
Checked by: BVC
Revisions:0
TIMMONS GROUP
YOUR VISION ACHIEVED THROUGH OURS.
610 East Morehead Street- Suite 2501Cha lotte, NC 28203
TEL 704.376. 10731 FAX 704.376.1076
NC License No. C-1652
Q STEWART-COOP ER- NEWELL
ARCHITECTS, P.A.
THIS DRAWING IS THE PROPERTY OF
STEWART—COOPER—NEWELL ARCHITECTS, PA.
AND IS SUBJECT TO FEDERAL COPYRIGHT
LAWS. THIS DRAWING MAY NOT BE
REPRODUCED, PUBLISHED OR USED IN ANY
WAY WITHOUT THE WRITTEN PERMISSION OF
STEWART—COOPER—NEWELL ARCHITECTS, PA.
SEAL
3 g =
��'Y•�NCINE�'•;���
�CRv3
0 00 (q o
a LO Lo
70 Cq (0c °O
ao U CD 0
z ti ti
U)
.6
co E
LL,
�fD
(6ca
U IL LL
N
O
_O
ti
�Ilp N c0
O
00
gIIIIIIl11111JJ)J))JJJJJJJJJJJ����%//D
E
0
II� )iiiii111%%1��//////
��11111111�`
(D
ca
U
O
z
z
Lw
O
w
w ~ z
(f)
= c) z0
v
�
I—
LiJ
CD
w L1 J =
>O
J � p
U
LLJ o
LLJ
LL-i
U
z
O
Sheet Number
C000
L-