Loading...
HomeMy WebLinkAboutSW6200102_Plan (Planting)_20200608ELEVATION=261.6' P-02 BORE HOLE INV.OUT=241.87' (S) INV.IN=243.76' (E) TOP=249.82' 18" RCP 1 8 " RCP 18" RCPELEVATION=257.1' B-02 BORE HOLE ELEVATION=255.5' B-01 BORE HOLE ELEVATION=259.8' P-04 BORE HOLE ELEVATION=256.0' S-03 BORE HOLE ELEVATION=253.3' S-04 BORE HOLE ELEVATION=252.1' B-05 BORE HOLE ELEVATION=259.2' S-02 BORE HOLE ELEVATION=258.5' P-03 BORE HOLE (NO ACCESS TO INVERTS) TOP=256.76' (NO ACCESS TO INVERTS) TOP=256.80' CONC CONC CI CI CI CI 72" CHLK BOLLARDS (4) CB ELEVATION=260.8' S-01 BORE HOLE ELEVATION=259.7' B-04 BORE HOLE 72" CHLK (4) BOLLARDS ELEVATION=260.1' P-01 BORE HOLE ASPHALT ASPHALT ASPHALT ASPHALT18" C&G 18" C&G 18" C&G18" C&G 18" C&G18" C&G18" C&G18" C&G18" C&G (NO ACCESS TO INVERTS) TOP=265.06' CI WW WW HW HW WW WW INV.=260.00' INV.=260.97' ASPHALT INV.OUT=251.44' (W) INV.IN=251.52' (E) TOP=261.75' TOP=262.48' COMM MH BOTTOM BOX=243.25' TOP=252.87' COMM MH PVC PIPES VERTICAL UNKNOWN 6" CURB 6" CURB 6" CURB6" CURB 6" CURB6" CURB 6" CURB 6" CURB6" CURB(NO ACCESS TO INVERTS) INV 251.25' (FROM ASBUILTS) TOP=262.10' (NO ACCESS TO INVERTS) INV 250.68' (FROM ASBUILTS) TOP=262.04'24" RCPPARKING LOT EXISTING ASPHALT PARKING LOT EXISTING ASPHALT WOODED AREA WOODED AREA WOODED AREA WOODED AREA248249250250250 10" PVC10" PVC2 5 1 251 251251251251 2 5 2 252252252 2 5 2 2 5 2 252 2522522523861 252.13 HOLE B05 T 253 253 253253253253253253 2532532533815 253.30 HOLE S04 254 254 2 5 4 254254254254254254 254254254254P EL*607 2 5 5255255255255 255255 255 255255255255255255255 255 3803 255.46 HOLE B01 2 5 6256256256256 256256256256256 2 5 6256256256256256256 256256 256 3752 256.04 HOLE S03 2 5 7257257257 2572572572572572572572572572572572572572572572572572573799 257.12 HOLE B02 BL*607 EL*607 258 258 25825825825825 8258258258258258 2 5 8258258258258258258258258 258 258 3692 258.53 HOLE P03 DILAPIDATED FENCEEAGLE TALON DRIVE EAGLE TALON DRIVE259 259259 259259259259 259259 259 259 259259259259259259259 259259259259 259BL*607 8" PVC EL*607 3696 259.21 HOLE S02 2421 259.74 HOLE B-04 3715 259.80 HOLE P04 EL*607 BL*607 260 260 260 260 260 260 260 260260260260260260 260260 260 2602602602602602602 6 0 260260260260260 260 2602603352 260.13 HOLE P01 BL*607 18" RCP EL*607 BL*607 3344 260.78 HOLE S01 261261 261261261 2612612612612 6 1 261 261 2612612612612612612612612612 6 1 261261261261261261261261 BL*607 BL*607 EL*607 2764 261.60 HOLE P02 EL*607 262 262 262262262262262 262 2 6 2 262262262262262262262262262262262262 262 EL*607 BL*607 T EL*607 263 263263263263 2 6 3 263263263263 263 263263 2632632632638" PVC INV.OUT=241.37' (S) INV.IN=241.42' (N) INV.IN=242.69' (W) TOP=252.51' EL JB #108689 EL JB #112804 INV.OUT=255.50' (W) TOP=265.16' INV.OUT=242.90' (S) INV.IN=243.19' (N) TOP=256.48' 8" PVC 10" PVC INV.OUT=243.68' (S) INV.IN=245.63' (W) INV.IN=245.64' (E) TOP=256.74' (IN SECURED AREA) OFF SITE WV WV WV WV PIV FHFH WV WV WV FH WV FH WV PPL PPL #79677 83696 PPL PPL #108680 EL JB 83648 #79679 PPL #79677 83740 PPL 83786 #79678 PPL TOP=254.09' EL MH 8" PVC 264 264 264 264 264 265 265 265265 266 266 26 6266 267 267 GI-3 SDMH-4 SDMH-3 12"WWWRD RD RD CO CB-1CB-2 SDMH-1HW-1 CO COCO COHW-3 GI-1 HW-2 CI-2CI-1 SDMH-2 HW-6 GI-2 CI-4 HW-4CI-3 15"6"6"10"12"6"15"6"12"15"10"6"10"6"6"6"6"6"6"12"6"15"6"6"15"6"6"6"6"6"12"6"6" 10" 12" HW-5 12"x18" 1 5 " 18" SANSAN SANFWCO DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS CO 4" 4" 4" 4" 4" 4" 4" CO 4" 4" 4" 4" 4" 4" 4" CO CO CO CO CO CO COSDMH-5 SDMH-6 18"12"CO CO CO CO 6"6"15"15"15"15"15"WW SANSAN W W W CO CO CO CO CO 6" 6" 6" 6"6"6"6"6"6" CO CO CO CO CO CO CO6" 6" 6" 6" 6"6"6"6"CO 256256 256 260 260260260260 260 260 260 260260260 261 261 261 261 261 BIO RETENTION AREA #2 263 BIO RETENTION AREA #1 264 U.S. ARMY CORPS OF ENGINEERSHPTC_LP101.dgnANSI DCHECKED BY:DRAWN BY:ISSUE DATE:SHEET ID FILENAME:B C D E F G 2 3 4 5 6 7 8 9 10 DESIGNED BY:1 A MARKSIZE:SUBMITTED BY:DATECONTRACT NO.:®of Engineers US Army Corps CATEGORY CODEDESCRIPTIONP:\Projects\017001\03 CAD_BIM\_Sheets\06_Lndscp\HPTC_LP101.dgn23-MAR-202014:53 171-20-13R. BOSTONW912PM-19-C-000769 DARLINGTON AVENUEWILMINGTON DISTRICTWILMINGTON, NORTH CAROLINAFORT BRAGG, NORTH CAROLINASOF HUMAN PERFORMANCE TRAINING CENTER (HPTC)FY18 PN 79443W912PM-18-R-0003SOLICITATION NO.:DECEMBER 201910'10'10'STAGING AREA CONTRACTOR (HPTC) TRAINING CENTER HUMAN PERFORMANCE TURF FIELD FF EL 263.75 10'10' N GEOGRAPHIC COORDINATE DATA HORIZONTAL DATUM: NORTH CAROLINA STATE PLANE, NAD83. VERTICAL DATUM: NAVD88. UNITS OF MEASURE: U.S. SURVEY FEET. COORDINATES SHOWN IN FORMAT OF EASTING, NORTHING AND ELEVATION.LP101S.HAGGARDGRAPHIC SCALE: 1"=40'-0" 120'80'40'020'40' GENERAL NOTES M.MEYERG.LYNNLANDSCAPE PLANPLANT LEGEND LT X MT X FG X TREE - (Large: 30' to 100' in Height at Maturity) IDENTIFICATION NUMBER QUANTITY TREE - (Medium/Ornamental: 15' to 30' in Height at Maturity) IDENTIFICATION NUMBER QUANTITY PERENNIAL FLOWER / GRASS - (.5' to 4' in Height at Maturity) IDENTIFICATION NUMBER QUANTITY 16' ANTI-TERRORISM / FORCE PROTECTION (AT/FP) PLANT VEGETATION SETBACK LIMITS CONSTRUCTION LIMITS AREA TO BE SODDED SHEET NOTES 1 SHEET LP502. PROVIDE METAL LANDSCAPE EDGING. REFER TO RO 1 LP 4 SD - SD - SD - SD - SD - SD - SD - SD - SD - 1 1 1 7. 6. 5. 4. 3. 2. 1. LP501. ALLOW FOR TRUNK MOVEMENT. REFER TO SHEET TO THE MIDPOINT OF EACH STRAP. TIES SHOULD NOT NOT INJURE THE ROOT BALL. TIE WHITE FLAGGING TREE. DRIVE STAKES 2.5 FEET IN THE GROUND, DO AND GUYS PER TREE OR 3 STAKES AND GUYS PER STAKE AND GUY PLANTS USING 2 OPPOSING STAKES LP601 FOR LANDSCAPE PLANT SCHEDULE. LANDSCAPE DETAILS. REFER TO LANDSCAPE SHEET REFER TO LANDSCAPE SHEET LP501 FOR (FAYETTEVILLE) - PLANT HARDINESS ZONE 8. THE NORTH CAROLINA STATE REGION PLANT VEGETATION MUST BE ADAPTABLE TO PERIMETER OF THE BUILDING. LOCATED A MINIMUM OF 13 FEET AWAY FROM THE TREES, SHRUBS AND PERENNIALS SHALL BE ALL NEW LANDSCAPE PLANT MATERIAL, E.G. PLANT TO CREATE A PLANTER BED LOOK. TO ALSO RECEIVE MULCH SPREAD AROUND EACH NEWLY PLANTED TREE AND SHRUB. PERENNIALS OF SHREDDED HARDWOOD MULCH AROUND EACH PROVIDE 3" DEPTH, 1'-6" RADIUS (3'-0" DIAMETER) 8 LATERAL FEET AWAY FROM BURIED UTILITY LINES. TREES AND SHRUBS SHALL BE LOCATED AT LEAST CURBS AND WALKS. TREES SHALL NOT BE LOCATED WITHIN 4 FEET OF CM 2 CM 2