HomeMy WebLinkAboutSW6200102_Plan (Planting)_20200608ELEVATION=261.6'
P-02 BORE HOLE
INV.OUT=241.87' (S)
INV.IN=243.76' (E)
TOP=249.82'
18" RCP
1 8 " RCP
18" RCPELEVATION=257.1'
B-02 BORE HOLE
ELEVATION=255.5'
B-01 BORE HOLE
ELEVATION=259.8'
P-04 BORE HOLE
ELEVATION=256.0'
S-03 BORE HOLE
ELEVATION=253.3'
S-04 BORE HOLE
ELEVATION=252.1'
B-05 BORE HOLE
ELEVATION=259.2'
S-02 BORE HOLE
ELEVATION=258.5'
P-03 BORE HOLE
(NO ACCESS TO INVERTS)
TOP=256.76'
(NO ACCESS TO INVERTS)
TOP=256.80'
CONC
CONC
CI CI
CI
CI
72" CHLK
BOLLARDS (4)
CB
ELEVATION=260.8'
S-01 BORE HOLE
ELEVATION=259.7'
B-04 BORE HOLE
72" CHLK
(4)
BOLLARDS
ELEVATION=260.1'
P-01 BORE HOLE
ASPHALT
ASPHALT
ASPHALT
ASPHALT18" C&G 18" C&G
18" C&G18" C&G
18" C&G18" C&G18" C&G18" C&G18" C&G
(NO ACCESS TO INVERTS)
TOP=265.06'
CI
WW
WW
HW
HW
WW
WW
INV.=260.00'
INV.=260.97'
ASPHALT
INV.OUT=251.44' (W)
INV.IN=251.52' (E)
TOP=261.75'
TOP=262.48'
COMM MH
BOTTOM BOX=243.25'
TOP=252.87'
COMM MH
PVC PIPES
VERTICAL
UNKNOWN
6" CURB
6" CURB
6" CURB6" CURB
6" CURB6" CURB
6" CURB
6" CURB6" CURB(NO ACCESS TO INVERTS)
INV 251.25' (FROM ASBUILTS)
TOP=262.10'
(NO ACCESS TO INVERTS)
INV 250.68' (FROM ASBUILTS)
TOP=262.04'24" RCPPARKING LOT
EXISTING ASPHALT
PARKING LOT
EXISTING ASPHALT
WOODED AREA
WOODED AREA
WOODED AREA
WOODED AREA248249250250250
10" PVC10" PVC2
5
1
251
251251251251
2
5
2 252252252
2
5
2
2
5
2
252
2522522523861
252.13
HOLE B05
T
253
253
253253253253253253
2532532533815
253.30
HOLE S04
254
254
2
5
4
254254254254254254
254254254254P
EL*607
2
5
5255255255255
255255
255
255255255255255255255
255
3803
255.46
HOLE B01
2
5
6256256256256
256256256256256
2
5
6256256256256256256
256256
256
3752
256.04
HOLE S03
2
5
7257257257
2572572572572572572572572572572572572572572572572572573799
257.12
HOLE B02
BL*607
EL*607
258
258
25825825825825
8258258258258258
2
5
8258258258258258258258258
258
258
3692
258.53
HOLE P03
DILAPIDATED FENCEEAGLE TALON DRIVE EAGLE TALON DRIVE259
259259
259259259259
259259
259
259
259259259259259259259 259259259259
259BL*607
8" PVC
EL*607
3696
259.21
HOLE S02
2421
259.74
HOLE B-04
3715
259.80
HOLE P04
EL*607
BL*607
260
260
260
260
260
260
260
260260260260260260
260260
260
2602602602602602602
6
0
260260260260260 260
2602603352
260.13
HOLE P01
BL*607
18" RCP
EL*607
BL*607
3344
260.78
HOLE S01
261261
261261261
2612612612612
6
1 261
261
2612612612612612612612612612
6
1
261261261261261261261261
BL*607
BL*607
EL*607
2764
261.60
HOLE P02
EL*607
262
262
262262262262262
262
2
6
2 262262262262262262262262262262262262
262
EL*607
BL*607
T
EL*607
263
263263263263
2
6
3
263263263263
263
263263
2632632632638" PVC
INV.OUT=241.37' (S)
INV.IN=241.42' (N)
INV.IN=242.69' (W)
TOP=252.51'
EL JB #108689
EL JB #112804
INV.OUT=255.50' (W)
TOP=265.16'
INV.OUT=242.90' (S)
INV.IN=243.19' (N)
TOP=256.48'
8" PVC
10" PVC
INV.OUT=243.68' (S)
INV.IN=245.63' (W)
INV.IN=245.64' (E)
TOP=256.74'
(IN SECURED AREA)
OFF SITE
WV
WV
WV
WV
PIV
FHFH
WV
WV
WV
FH
WV
FH
WV
PPL
PPL
#79677 83696
PPL
PPL
#108680
EL JB
83648
#79679
PPL
#79677 83740
PPL
83786
#79678
PPL
TOP=254.09'
EL MH
8" PVC
264
264
264
264
264
265
265
265265
266
266
26
6266
267
267
GI-3
SDMH-4 SDMH-3 12"WWWRD
RD RD
CO
CB-1CB-2
SDMH-1HW-1
CO
COCO
COHW-3
GI-1
HW-2
CI-2CI-1
SDMH-2
HW-6
GI-2
CI-4
HW-4CI-3
15"6"6"10"12"6"15"6"12"15"10"6"10"6"6"6"6"6"6"12"6"15"6"6"15"6"6"6"6"6"12"6"6"
10"
12"
HW-5
12"x18"
1 5 "
18"
SANSAN SANFWCO
DS
DS DS DS DS DS DS DS DS DS
DS
DS DS DS
DS DS DS DS DS DS
DS
DS DS
DS
CO
4"
4"
4"
4"
4"
4"
4"
CO
4"
4"
4"
4"
4"
4"
4"
CO
CO
CO
CO
CO
CO
COSDMH-5
SDMH-6
18"12"CO
CO
CO
CO
6"6"15"15"15"15"15"WW
SANSAN
W
W
W
CO
CO
CO
CO
CO
6"
6"
6"
6"6"6"6"6"6"
CO
CO CO
CO
CO
CO
CO6"
6"
6"
6"
6"6"6"6"CO
256256
256
260
260260260260
260
260
260 260260260
261
261
261
261
261
BIO RETENTION AREA #2
263
BIO RETENTION AREA #1
264
U.S. ARMY CORPS OF ENGINEERSHPTC_LP101.dgnANSI DCHECKED BY:DRAWN BY:ISSUE DATE:SHEET ID FILENAME:B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
DESIGNED BY:1
A MARKSIZE:SUBMITTED BY:DATECONTRACT NO.:®of Engineers
US Army Corps
CATEGORY CODEDESCRIPTIONP:\Projects\017001\03 CAD_BIM\_Sheets\06_Lndscp\HPTC_LP101.dgn23-MAR-202014:53 171-20-13R. BOSTONW912PM-19-C-000769 DARLINGTON AVENUEWILMINGTON DISTRICTWILMINGTON, NORTH CAROLINAFORT BRAGG, NORTH CAROLINASOF HUMAN PERFORMANCE TRAINING CENTER (HPTC)FY18 PN 79443W912PM-18-R-0003SOLICITATION NO.:DECEMBER 201910'10'10'STAGING AREA
CONTRACTOR
(HPTC)
TRAINING CENTER
HUMAN PERFORMANCE
TURF FIELD
FF EL 263.75
10'10'
N
GEOGRAPHIC COORDINATE DATA
HORIZONTAL DATUM:
NORTH CAROLINA STATE PLANE, NAD83.
VERTICAL DATUM: NAVD88.
UNITS OF MEASURE: U.S. SURVEY FEET.
COORDINATES SHOWN IN FORMAT OF
EASTING, NORTHING AND ELEVATION.LP101S.HAGGARDGRAPHIC SCALE: 1"=40'-0"
120'80'40'020'40'
GENERAL NOTES
M.MEYERG.LYNNLANDSCAPE PLANPLANT LEGEND
LT
X
MT
X
FG
X
TREE - (Large: 30' to 100'
in Height at Maturity)
IDENTIFICATION NUMBER
QUANTITY
TREE - (Medium/Ornamental: 15' to 30'
in Height at Maturity)
IDENTIFICATION NUMBER
QUANTITY
PERENNIAL FLOWER / GRASS - (.5' to 4'
in Height at Maturity)
IDENTIFICATION NUMBER
QUANTITY
16' ANTI-TERRORISM / FORCE
PROTECTION (AT/FP) PLANT
VEGETATION SETBACK LIMITS
CONSTRUCTION LIMITS
AREA TO BE SODDED
SHEET NOTES
1
SHEET LP502.
PROVIDE METAL LANDSCAPE EDGING. REFER TO
RO
1
LP
4
SD
-
SD
-
SD
-
SD
-
SD
-
SD
-
SD
-
SD
-
SD
-
1
1
1
7.
6.
5.
4.
3.
2.
1.
LP501.
ALLOW FOR TRUNK MOVEMENT. REFER TO SHEET
TO THE MIDPOINT OF EACH STRAP. TIES SHOULD NOT
NOT INJURE THE ROOT BALL. TIE WHITE FLAGGING
TREE. DRIVE STAKES 2.5 FEET IN THE GROUND, DO
AND GUYS PER TREE OR 3 STAKES AND GUYS PER
STAKE AND GUY PLANTS USING 2 OPPOSING STAKES
LP601 FOR LANDSCAPE PLANT SCHEDULE.
LANDSCAPE DETAILS. REFER TO LANDSCAPE SHEET
REFER TO LANDSCAPE SHEET LP501 FOR
(FAYETTEVILLE) - PLANT HARDINESS ZONE 8.
THE NORTH CAROLINA STATE REGION
PLANT VEGETATION MUST BE ADAPTABLE TO
PERIMETER OF THE BUILDING.
LOCATED A MINIMUM OF 13 FEET AWAY FROM THE
TREES, SHRUBS AND PERENNIALS SHALL BE
ALL NEW LANDSCAPE PLANT MATERIAL, E.G.
PLANT TO CREATE A PLANTER BED LOOK.
TO ALSO RECEIVE MULCH SPREAD AROUND EACH
NEWLY PLANTED TREE AND SHRUB. PERENNIALS
OF SHREDDED HARDWOOD MULCH AROUND EACH
PROVIDE 3" DEPTH, 1'-6" RADIUS (3'-0" DIAMETER)
8 LATERAL FEET AWAY FROM BURIED UTILITY LINES.
TREES AND SHRUBS SHALL BE LOCATED AT LEAST
CURBS AND WALKS.
TREES SHALL NOT BE LOCATED WITHIN 4 FEET OF
CM
2
CM
2