HomeMy WebLinkAboutWI0700459_Injection Event Record_20190509Permit Number WI0700459
Central Files: APS _ SVVP
5/9/2019
Permit Tracking Slip
Program Category
Ground Water
Permit Type
Injection In situ Groundwater Remediation Well
Primary Reviewer
shristi.shrestha
Coastal SWRule
Permitted Flow
Facility
Status
Active
Version
1.00
Project Type
New Project
Permit Classification
Individual
Permit Contact Affiliation
Facility Name
Former West Pharmaceutical Services Facility
Location Address
2525 Rouse Rd Extension
Kinston NC
Owner
28504
Major/Minor
Minor
Facility Contact Affiliation
Region
Washington
County
Lenoir
Owner Name
West Pharmaceutical
Dates/Events
Owner Type
Non -Government
Owner Affiliation
Steven Walton
530 Hermna O W Dr
Franklin Ctr
PA 19341
Orig Issue
9/14/2017
App Received
7/18/2017
Regulated Activities
Draft Initiated
Scheduled
Issuance
Groundwater remediation
Outfall
Public Notice Issue
9/14/2017
Requested /Received Events
Effective
9/14/2017
Expiration
8/31/2022
Additional information requested
Additional information received
RO staff report requested
RO staff report received
Additional information requested
Additional information received
8/22/17
9/6/17
7/20/17
8/9/17
9/11/17
9/12/17
Waterbody Name Streamlndex Number Current Class Subbasin
563-00 9-s9
Print Form
WELL CONSTRUCTION RECORD (GW-1)
1. Well Contractor Information:
SVAN
Well Contractor Name
q/6-6
NC Well Contractor Certification Number
Company Name
2. Well Construction Permit #:
Ool-postilr
List all applicable well constntction permits (i.e. U1C, County, State, Variance. etc)
3. Well Use (check well use):
Water Supply Well:
Agricultural
Geothermal (Heating/Cooling Supply)
D Industrial/Commercial
�Inigation
Non -Water Supply Well:
Monitoring
DMunicipallPublic
Residential Water Supply (single)
DResidential Water Supply (shared)
t._i Recovery
Injection Well:
Aquifer Recharge
EllAquifer Storage and Recovery
Aquifer Test
Experimental Technology
BGeothermal (Closed Loop)
Geothermal (Heating/Cooling Return)
4. Date Well(s) Completed:5 /6/
5a. Well Location:
,Groundwater Remediation
Salinity Barrier
0Stortnwater Drainage
[Subsidence Control
Tracer
Other (explain under #21 Remarks)
'1 'ffi
5/2s//&
Well LD# J-P/ 17/7"S6)
Facility/Owner Name Facility iD# (if applicable)
gts fit .. Erb 14As4mivc 28Scy
Physical Address, City, and Zip
Oi ✓
County Parcel identification No. (PIN)
5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees:
(if well field, one tat/long is sufficient)
3S• 9/gi5 N-�.6/3- 23 W
6. Is(are) the well(s)lPermanent or Wremporary
7. Is this a repair to an existing well: DYes or
If this is a repair. fill out known well construction information and expiate the nature of the
repair tender #21 remarks section or on the back of this (oxen.
8. For Geoprobe/DPT or Closed -Loop Geothermal Wells having the same
construction, only I t »' 1 is needed. indicate TOTAL NUMBER of wells
drilled: t, J
9. Total well depth below land surface: (ft.)
For multiple wells list all depths if different ee mntple- 3(tt 200' and 2 r@i 100')
10. Static water level below top of casing: (ft.)
If water level is above rasing. use "+
11. Borehole diameter:
If ✓ (in.)
12. Well construction method: 1,/ ee'-T N
(n.e. auger, rotary, cable, direct push, etc.)
FOR WATER SUPPLY WELLS ONLY:
13a. Yield (gpm) Method of test:
13b. Disinfection type: Amount:
For internal Use Only:
14. WATER ZONES _
FROM
TO
DESCRIPTION
ft.
ft.
ft.
ft.
15. OUTER CASING (for multi -cased wells) OR LINER (if ap licable)
FROM
TO
DIAMETER
THICKNESS
MATERIAL
ft.
ft.
in.
16. INNER CASING OR TUBING (geothermal closed -loop)
FROM
TO
DIAMETER
THICKNESS
MATERIAL
ft.
ft.
in.
ft
ft.
in.
17. SCREEN
FROM
TO
DIAMETER
SLOT SIZE
THICKNESS
MATERIAL
ft.
ft.
in.
ft.
ft.
in.
1S. GROUT
FROM
TO
MATERIAL
EMPLACEMENT METHOD & AMOUNT
ft.
ft.
ft.
ft.
ft.
ft.
19. SAND/GRAVEL PACK (if applicable)
FROM
TO
MATERIAL
EMPLACEMENT METHOD
ft.
ft.
ft.
ft.
20. DRILLING LOG (attach additional sheets If necessary)
FROM
TO
DESCRIPTION (color, hardness, soiUrock type, grain size, etc.)
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
21. REMARKS
(/, , j,,4
22. Certification:
Signature of Certified Well Contractor Date
By signing this form, I hereby cert that the well(s) was (were) constructed in accordance
with ISA NCAC 02C.0100 or ISA NCAC 02C.0200 Well Construction Standards and that a
copy of this record hos been provided to the well owner.
23. Site diagram or additional well details:
You may use the back of this page to provide additional well site details or well
construction details. You may also attach additional pages if necessary.
SUBMITTAL INSTRUCTIONS
24a. For All Wells: Submit this form within 30 days of completion of well
construction to the following:
Division of Water Resources, Information Processing Unit,
1617 Mail Service Center, Raleigh, NC 27699-1617
24b, For Infection Wells: In addition to sending the form to the address in 24a
above, also submit one copy of this form within 30 days of completion of well
construction to the following.
Division of Water Resources, Underground Injection Control Program,
1636 Mail Service Center, Raleigh, NC 27699-1636
24c. For Water Supply & Iniection Wells: In addition to sending the form to
the address(es) above, also submit one copy of this form within 30 days of
completion of well construction to the county health department of the county
where constructed.
Form GW-I Nonh Carolina Department of Environmental Quality - Division of Water Resources
Revised 2-22-2016
WELL ABANDONMENT RECORD
For Internal Use ONLY:
I. «'ell Contractor Information:
Well C ntractor Name (or well owner personally abandoning well on his/her property)
i4p1Q-C
1 !II'ti�i
\'C Yell Contractor Certification Number
LLc;.
IUN 2 2 /
Company Name Qua
W _
2. Well Construction Permit #: 100 -TO 045- 1'ermir
List all applicable well construction permits (i.e. UIC, County, State, Variance, etc) if known
3. Well use (check well use):
Water Supply Well:
❑Agricultural
OGeothermal (Heating/Cooling Supply)
❑lndustriallCommercial
❑Irrigation
Non -Water Supply Well:
❑Monitoring
❑Municipal/Public
❑Residential Water Supply (single)
❑Residential Water Supply (shared)
❑Recovery
Injection Well:
❑Aquifer Recharge
❑Aquifer Storage and Recovery
❑Aquifer Test
❑Experimental Technology
OGeothermal (Closed Loop)
OGeothermal (Heating/Cooling Return)
) roundwater Remediation
❑ Salinity Barrier
❑Stormwater Drainage
❑Subsidence Control
OTracer
❑Other (explain under 7g)
4. Date well(s) abandoned:
5a. Well location:
51i(It q 5M
,rater west Pfwa,,l4?4,41 I/i L S:k
Facility/Owner Name Facility ID# (if applicable)
WELL ABANDONMENT DETAILS
7a. For Geoprobe/DPT or Closed -Loop Geothermal Wells having the same
well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of
wells abandoned:
So
7b. Approximate volume of water remaining in well(s):
(gal.)
FOR WATER SUPPLY WELLS ONLY:
7c. Type of disinfectant used:
7d. Amount of disinfectant used:
7e. Sealing materials used (check all that apply):
)(Bentonite Chips or Pellets
❑ Dry Clay
❑ Drill Cuttings
❑ Gravel
O Other (explain under 7g)
❑ Neat Cement Grout
❑ Sand Cement Grout
❑ Concrete Grout
❑ Specialty Grout
0 Bentonite Slurry
7E For each material se cted above, provide amount of materials used:
40,i1 &A4 l mac 12cx7 r
or 264444E4.
7g. Provide a brief description of the abandonment rocedure:
Wu 6e� wig Oa /G 4,//I:,
t7. /1 leJt7lyv ilL si c C .
8. Certification
25< +we �2f k K4 ; n 51u^ IJG !'.85c3E1
Physical Address, City. and Zip
Coos(
County
Parcel Identification No. (PIN)
5b. Latitude and longitude in degrees/minutes/seconds or decimal d
(if well field, one lat/long is sufficient)
35r3179i5 N-77.64336a
W
CONSTRUCTION DETAILS OF WELLS) BEING ABANDONED
Attach well construction record(s) ifavailable. For multiple injection or non -water supply wells
ONLY with the same construction/abandonment. you can .submit one. form.
I�Q
6a. Well ID#: .+/rr `' ' lP-5O
6b. Total well depth:
/5
6c. Borehole diameter:
r/5
(ft.)
(in.)
6d. Water level below ground surface: i° (ft.)
6e. Outer casing length (if known): (ft.)
6f. inner casing/tubing length (if known): (ft.)
6g. Screen length (if known): (ft.)
Fort G W -30
Signature of
Owner Date
form, I hereby certify that the well(s) was (were) abandoned in
with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards
at a copy of this record has been provided to the well owner.
9. Site diagram or additional well details:
You may use the back of this page to provide additional well site details or well
abandonment details. You may also attach additional pages if necessary.
SUBMITTAL INSTRUCTIONS
10a. For All Wells: Submit this form within 30 days of completion of well
abandonment to the following:
Division of Water Resources, Information Processing Unit,
1617 Mail Service Center, Raleigh, NC 27699-1617
10b. For Injection Wells: Li addition to sending the form to the address in l0a
above, also submit one copy of this form within 30 days of completion of well
abandonment to the following:
Division of Water Resources, Underground Injection Control Program,
1636 Mail Service Center, Raleigh, NC 27699-1636
10c. For Water Supply & Injecton Wells: In addition to sending the form to the
address(es) above. also submit one copy of this form within 30 days of completion
of well abandonment to the county health department of the county where
abandoned.
North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Field Summary Report for the Former West Pharmaceutical Services Site ABC Injections
Kinston, NC
Prepared by Kyle Basely on June 8, 2018
Project Name
ERM — Kinston, NC
Start and End Date
May 14-25, 2018
City and State
Kinston, NC
Address
Former West Pharmaceutical
Services Site,
2525 Rouse Road Ext
Kinston, NC 28504
Contaminant of Concern
Chlorinated Solvents
Contaminated Media
Groundwater
Field Contractor
Redox Tech, LLC
Client
ERM
Ed Hollifield
Address
200 Quade Drive
Cary, NC
Address
Ballantyne One
15720 Brixham Hill Ave,
Suite 120
Charlotte, NC
Field Lead
Kyle Baseley
Oversight
Chris Means
Phone Number
919-395-9709
Phone Number
336-406-7625
Email
baseley(a redox-tech.com
Email
chris.means(a erm.com
Crew Members
Kyle Baseley, Jon Sawyer
Number of Points and
Depths
50 points, 15-6 ft bgs
Chemical
ABC
Mass or Volume
25,000 lbs
Concentration of
Chemical
85 gal solution per interval
125 lbs ABC per interval
0.125 liter DHC per interval
Volume of Solution or
Slurry
17,000 gallons
Page 1
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Brief Narrative
During the period from May 14-15, 2018 Redox Tech installed four (4) separate 2-inch monitoring wells designated MW-16, MW-17,
MW-18, and MW-19 at locations determined by ERM using 4.25 inch hollow stem augers driven by a 67 series Geoprobe track rig.
Each well was installed to a depth of 18 ft bgs and screened from 18-8 ft bgs. A 2 ft bentonite seal was placed above the gravel pack
from 7-5 ft and grouted from 5 ft to the surface using Portland cement. A protective casing was installed with a concrete pad and
identification tag. The wells were developed and sampled by ERM before injections began.
During the period from May 16-25, 2018 Redox Tech injected a total of 25,000 lbs of ABC, 3,400 lbs of Sodium Bicarbonate, 300 lbs
of Dipotassium Phosphate and 25 L of DHC in a total injectate volume of 17,000 gal across fifty (50) unique injection points
determined by ERM. Water used to make the solution was supplied from a nearby fire hydrant via 2.5 inch fire hose, stored in bladder
tanks, and deoxygenated using 1,700 lbs of sugar and 17 lbs of yeast. An attempt was made to allow the water to deoxygenate for at
least 24 hours before injecting. However, in instances where that was not possible, 0.1 lbs of sodium sulfite was added to each 340 gal
batch before the introduction of DHC to reduce the dissolved oxygen content. Injectate was mixed in fifty (50) separate 340 gal
batches consisting of 500 lbs of ABC, 68 lbs of Sodium Bicarbonate, 6 lbs of DKP, 0.5 L of DHC and approximately 270 gal of
deoxygenated water. Each batch of injectate was intended to be distributed evenly over four (4) depth intervals, 85 gal per interval, at
each unique injection point.
Page 2
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Redox Tech's crew consisted of Kyle Baseley and Jonathan Sawyer with oversight functions provided by ERM's Tom Naumann.
DPT rods were advanced by a Geoprobe 67 series track rig and the ABC solution was mixed in a 550 gal poly tank using a pneumatic
stand mixer. The solution was injected using a 2 inch Versamatic high pressure diaphragm pump.
The original work plan called for injections to take place at fifty (50) separate points in four (4) separate depth intervals of 15, 12, 9
and 6 ft bgs using a bottom up injection approach. Attempts were made to follow the work plan as closely as possible but due to
daylighting at the majority of points most injection attempts at shallower depth intervals failed. When it was not possible to complete
injections at one point the remaining injectate was introduced in the deeper intervals of the following point. Care and extra time were
taken in the field to distribute amendments as evenly as possible across the entire target area. Table 1 contains in depth notes and data
of all injection activities.
Table I. Injection Details
Date
Injection
Point
Depth (ft)
Mix
Number
Start Time
Stop Time
Injection
Pressure
(psi)
Volume
Injected
(gal)
Notes (flow change, etc.)
5/16/2018
IP-1
15
9:24
9:32
40
85
5/16/2018
1P-1
5/16/2018
1P-1 (2)
5/16/2018
1P-1 (4)
12
9
6
9:32
9:41
40
85
daylighted
9:52
10:00
20
85
10:10
10:22
10
0
daylighted
Page 3
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Table 1. Injection Details
Date
Injection
Point
Depth (ft)
Mix
Number
Start Time
Stop Time
Injection
Pressure
(psi)
Volume
Injected
(gal)
Notes (flow change, etc.)
5/16/2018
IP-2 (2)
15
1
10:35
10:45
10
85
daylighted
5/16/2018
IP-2 (3)
15
2
10:56
11:11
10
85
5/16/2018
IP-2 (3)
12
2
11:11
11:25
10
85
5/16/2018
IP-2 (3)
9
2
11:31
11:37
10
20
daylighted
5/16/2018
IP-2 (4)
9
2
11:43
11:53
10
40
daylighted
5/16/2018
IP-2 (5)
6
2
12:05
12:25
10
110
daylighted
5/16/2018
IP-15
15
3
14:00
14:16
10
85
5/16/2018
IP-15
12
3
14:16
14:33
10
65
daylighted
5/16/2018
IP-23
15
3
14:37
14:50
5
85
5/16/2018
IP-23
12
3
14:50
15:15
5
105
5/16/2018
IP-15 (2)
9
4
15:27
15:30
5
40
daylighted
5/16/2018
IP-23
9
4
15:31
15:34
5
0
daylighted
5/16/2018
IP-15 (3)
9
4
15:41
15:50
5
45
daylighted
5/16/2018
IP-23 (2)
9
4
15:55
15:57
5
0
daylighted
5/16/2018
IP-32
15
4
16:04
16:05
5
0
daylighted
Page 4
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Table 1. injection Details
Date
Injection
Point
Depth (It)
Mix
Number
Start Time
Stop Time
Injection
Pressure
(psi)
Volume
Injected
(gal)
Notes (flow change, etc.)
5/16/2018
IP-23 (3)
9
4
16:20
16:34
5
85
5/16/2018
IP-24
15
4
16:40
17:25
5
170
stopped pumping to mix new tank
5/16/2018
IP-24
15
5
17:30
18:10
5
170
5/16/2018
IP-32 (2)
15
5
18:15
18:18
5
0
daylighted
5/16/2018
IP-24
12
5
18:30
18:35
10
10
daylighted
5/16/2018
IP-24(2)
12
5
18:45
18:49
10
10
5/16/2018
IP-24(3)
12
5
18:55
19:30
10
150
5/17/2018
IP-25
15
6
8:12
8:34
5
85
5/17/2018
IP-25
12
6
8:40
8:53
5
85
5/17/2018
1P-25
9
6
8:58
9:05
5
85
5/17/2018
IP-25
6
6
9:10
9:11
5
0
daylighted
5/17/2018
IP-33
15
6
9:12
9:30
5
85
stopped pumping to mix new tank
5/17/2018
IP-33
15
7
9:34
9:54
5
85
5/17/2018
IP-33
12
7
9:54
10:06
5
40
daylighted
5/17/2018
IP-33 (2)
12
7
10:07
10:18
5
0
daylighted
Page 5
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Table 1. Injection Details
Date
Injection
Point
Depth (ft)
Mix
Number
Start Time
Stop Time
Injection
Pressure
(Psi)
Volume
Injected
(gal)
Notes (flow change, etc.)
5/17/2018
IP-34
15
7
10:22
11:38
5
215
stopped pumping to mix new tank
5/17/2018
1P-34
15
8
11:44
12:00
5
85
5/17/2018
IP-34
12
8
12:05
12:22
5
85
5/17/2018
IP-34
9
8
12:23
12:50
5
85
5/17/2018
IP-34
6
8
13:01
13:12
5
85
5/17/2018
IP-26
15
9
14:40
15:02
5
85
5/17/2018
IP-26
12
9
15:02
15:11
5
40
daylighted
5/17/2018
IP-27
15
9
15:15
16:14
5
215
Corrected value, notes indicated 300 gal
5/17/2018
IP-27
12
10
16:19
16:20
5
0
daylighted
5/17/2018
IP-19
15
10
16:24
16:40
5
40
daylighted
5/17/2018
IP-18
15
10,11
17:05
19:01
5
640
5/17/2018
IP-18
12
12
19:20
19:54
5
170
half tank left overnight
5/18/2018
IP-18
9
12
7:04
7:09
5
10
daylighted
5/18/2018
IP-11
15
12
7:12
7:53
5
160
stopped pumping to mix new tank
5/18/2018
1P-11
15
13
7:58
8:24
5
85
Page 6
REDOX TECH, LAC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Table 1. Injection Details
Date
Injection
Point
Depth (ft)
Miz
Number
Start Time
Stop Time
Injection
Pressure
(psi)
Volume
Injected
(gal)
Notes (flow change, etc.)
5/18/2018
1P- I 1
12
13
8:24
8:49
5
85
5/18/2018
IP-1l
9
13
8:52
8:58
5
40
daylighted
5/18/2018
1P-5
15
13
9:03
9:16
5
45
daylighted
5/18/2018
IP-I2
15
13,14
9:23
9:50
5
170
daylighted
5/18/2018
IP-6
15
14
9:58
10:06
5
40
daylighted
5/18/2018
IP-6 (2)
15
14
10:13
10:30
5
45
daylighted
5/18/2018
IP-6 (3)
15
14
10:40
10:49
5
20
daylighted
5/18/2018
IP-6 (4)
15
14
10:55
11:07
5
65
daylighted
5/18/2018
IP-6 (5)
15
14
11:12
11:58
5
85
Corrected value, notes indicated 170 gal
5/21/2018
1P-6 (5)
15
15
9:18
10:32
5
340
5/21/2018
IP-6 (5)
12
16
10:40
11:52
5
340
5/21/2018
IP-6 (5)
9
17
13:17
13:20
5
20
daylighted
5/21/2018
IP-10
15
17
13:20
13:27
5
20
daylighted
5/21/2018
IP-17
15
17
13:27
13:35
5
20
daylighted
5/21/2018
IP-4
15
17
13:37
13:45
5
25
daylighted
Page 7
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Table 1. Injection Details
Date
Injection
Point
Depth (ft)
Mix
Number
Start Time
Stop Time
Injection
Pressure
(psi)
Volume
Injected
(gal)
Notes (flow change, etc.)
5/21/2018
IP-4 (2)
15
17
13:49
13:55
5
45
daylighted
5/21/2018
IP-9
15
17
13:56
14:10
5
40
daylighted
5/21/2018
IP-3
15
17
14:19
14:30
5
85
daylighted
5/21/2018
IP-16
15
17
14:34
14:39
5
40
daylighted
5/21/2018
IP-9 (2)
15
17
14:40
14:45
5
45
stopped pumping to mix new tank
5/21/2018
IP-9 (2)
15
18
14:59
15:20
5
85
daylighted
5/21/2018
IP-8
15
18
15:20
16:15
5
255
stopped pumping to mix new tank
5/21/2018
IP-8
15
19
16:30
18:12
5
340
5/21/2018
IP-8
12
20
18:20
18:45
5
85
daylighted
5/21/2018
IP-16 (3)
15
20
18:46
19:30
5
255
5/22/2018
IP-31
15
21
9:22
10:38
5
340
5/22/2018
1P-31
12
22
10:46
11:30
5
255
daylighted
5/22/2018
IP-32 (3)
15
22
11:35
11:35
0
rods clogged
5/22/2018
IP-32 (4)
15
22
11:55
12:05
5
20
daylighted
5/22/2018
IP-40
15
22
12:08
12:30
5
65
Page 8
REDOX TECH, LLC
"Providing innovative In Situ Soil and Groundwater Treatment"
Table 1. Injection Details
Date
Injection
Point
Depth (ft)
Mix
Number
Start Time
Stop Time
Injection
Pressure
(Psi)
Volume
Injected
(gal)
Notes (flow change, etc.)
5/22/2018
IP-40
15
23
13:30
13:34
5
40
daylighted
5/22/2018
IP-41
15
23
13:42
13:45
5
45
daylighted
5/22/2018
IP-47
15
23
13:50
14:11
5
125
daylighted
5/22/2018
IP-48
15
23
14:15
14:47
5
130
stopped pumping to mix new tank
5/22/2018
1P-48
15
24
14:57
15:52
15
340
stopped pumping to mix new tank
5/22/2018
IP-48
15
25
15:57
16:51
15
340
5/22/2018
IP-48
12
26
16:58
17:15
15
85
daylighted. 0.1 lbs of sodium sulfite added to
batch 26
5/22/2018
1P-42
15
26
17:17
17:35
15
85
daylighted
5/22/2018
1P-49
15
26
17:40
18:27
15
170
stopped pumping to mix new tank
5/22/2018
IP-49
15
27
18:38
19:30
15
340
0.1 lbs of sodium sulfite added to batch 27
5/23/2018
IP-49
15
28
7:56
8:48
15
340
5/23/2018
IP-49
12
29
8:55
9:45
15
340
5/23/2018
IP-49
12
30
9:55
10:45
15
340
5/23/2018
IP-49
9
31
10:53
11:13
15
170
daylighted
5/23/2018
IP-35
15
31
11:20
11:50
15
170
stopped pumping to mix new tank
Page 9
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Table 1. Injection Details
Date
In;cction Point
I oint
Depth (i't)
Mix
Number
Start Time
Stop Time
Injection
Pressure
(psi)
Volume
Injected
(gal)
Notes (flow change, etc.)
5/23/2018
1P-35
15
32
13:15
13:30
15
85
5/23/2018
IP-35
12
32
13:31
13:44
15
85
5/23/2018
IP-35
9
32
13:45
14:00
15
85
5/23/2018
IP-35
6
32
14:02
14:05
15
5
daylighted
5/23/2018
IP-43
15
32
14:07
14:07
40
0
bad injection head
5/23/2018
IP-43 (2)
15
32
14:10
14:10
40
0
clogged rods
5/23/2018
IP-50
15
32
14:30
14:30
40
0
clogged rods
5/23/2018
IP-43(3)
15
32
14:45
15:06
40
80
5/23/2018
IP-43 (3)
15
33
15:17
15:30
40
85
5/23/2018
IP-43 (3)
12
33
15:31
15:54
40
170
5/23/2018
1P-43 (3)
9
33
15:55
16:07
40
85
5/23/2018
IP-50 (2)
15
34
16:12
16:24
40
85
5/23/2018
IP-50 (2)
12
34
16:25
16:49
40
170
daylighted
5/23/2018
IP-44
15
34
16:53
17:05
40
85
stopped pumping to mix new tank
5/23/2018
IP-44
15
35
17:08
17:19
40
85
Page 10
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Table 1. Injection Details
Date
Injection
point
Depth (ft)
M i x
Number
Start Time
Stop Time
Injection
Pressure
(psi)
Volume
Injected
(gal)
Notes (flow change, etc.)
5/23/2018
IP-44
12
35
17:21
17:41
40
170
5/23/2018
IP-44
9
35
17:43
17:51
40
85
5/23/2018
IP-45
15
36
18:00
18:14
40
85
5/23/2018
IP-45
12
36
18:16
18:45
40
170
5/23/2018
IP-45
9
36
18:45
19:00
40
85
5/24/2018
IP-37
15
37
8:30
8:45
40
85
5/24/2018
IP-37
12
37
8:45
9:10
40
170
5/24/2018
1P-37
9
37
9:11
9:25
40
85
5/24/2018
IP-36
15
38
9:35
9:52
40
85
5/24/2018
1P-36
12
38
9:53
10:19
40
170
5/24/2018
1P-36
9
38
10:20
10:35
40
85
5/24/2018
IP-28
15
39
10:40
10:53
40
85
5/24/2018
IP-28
12
39
10:53
11:04
40
170
5/24/2018
IP-28
9
39
11:05
11:23
40
85
5/24/2018
IP-20
15
40
11:45
11:50
40
45
daylighted
Page 11
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Table 1. Injection Details
Date
Injection
Point
Depth (ft)
Mix
Number
Start Time
Stop Time
Injection
Pressure
(psi)
Volume
Injected
(gal)
Notes (flow change, etc.)
5/24/2018
IP-29
15
40
11:53
12:37
40
295
5/24/2018
IP-29
15
41
14:05
14:15
40
85
5/24/2018
1P-29
12
41
14:16
14:39
40
170
5/24/2018
IP-29
9
41
14:40
14:45
40
45
daylighted
5/24/2018
IP-38
15
41
14:45
14:56
40
40
stopped pumping to mix new tank
5/24/2018
1P-38
15
42
15:03
15:18
40
85
5/24/2018
IP-38
12
42
15:18
15:45
40
170
5/24/2018
IP-38
9
42
15:45
16:00
40
85
5/24/2018
IP-I3
15
43
16:15
16:24
40
85
5/24/2018
IP-13
12
43
16:25
16:30
40
40
daylighted
5/24/2018
IP-21
15
43
16:30
17:10
40
215
stopped pumping to mix new tank
5/24/2018
IP-21
15
44
17:15
17:30
40
85
5/24/2018
IP-21
12
44
17:31
17:44
40
40
daylighted
5/24/2018
IP-30
15
44
17:45
18:18
40
215
stopped pumping to mix new tank
5/24/2018
1P-30
15
45
18:20
18:35
40
85
Page 12
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Table 1. Injection Details
Date
Injection
Point
Depth (ft)
Mix
Number
Start Time
Stop Time
Injection
Pr ssure
( si)
Volume
Injected
(gal)
Notes (flow change, etc.)
5/24/2018
IP-30
12
45
18:36
19:05
40
170
daylighted
5/24/2018
IP-22
15
45
19:05
19:20
40
85
daylighted
5/25/2018
IP-14
15
46
7:27
8:25
40
340
stopped pumping to mix new tank
5/25/2018
1P-14
15
47
8:36
8:51
40
85
5/25/2018
IP-14
12
47
8:52
9:17
40
170
5/25/2018
IP-14
9
47
9:18
9:26
40
85
daylighted
5/25/2018
IP-7
15
48
9:35
9:50
40
85
daylighted
5/25/2018
IP-39
15
48
10:11
10:40
40
255
5/25/2018
1P-39
15
49
10:45
11:30
40
340
5/25/2018
IP-46
15
50
11:40
11:46
40
40
daylighted
5/25/2018
IP-39
15
50
11:46
12:20
40
300
*Injection points followed by a (#) denote multiple attempts, for example IP-75 (3) would indicate injections occurred at the 3`d string of rods pushed for IP-75
Page 13
REDOX TECH, LLC
"Providing Innovative In Situ Soil and Groundwater Treatment"
Figure 1. Injection Location Map
r
Fest Area
- ----- -
Page 14