Loading...
HomeMy WebLinkAboutWQ0005603_Engineering Report_20210506Apri129, 2021 Mr. S. Daniel Smith Director Division of Water Resources NCDEQ Dear Mr. Smith, a s Ps Fm, Civil & Environmental Consultants, Inc. Subject: Engineering Report for Permit Conditions related to Permit No. WQ0005603 Coats North America — Sevier Plant Marion, North Carolina CEC Project 304-826 Attached is the one (1) engineering report addressing permit conditions I.2-I.6 for permit #WQ0005603 for the coal combustion residual basin evaluation for your review. As a summary of what is included in the attached report: • Condition L2 — Install temporary seal on all stormwater piping in both cells. o Coats has performed this temporary seal. • Condition I.3 — Submit plan to permanently seal all stormwater piping in both cells. o Engineering drawings from Appendix B include plan to permanently seal. • Condition I.4 — Alternatives considered to eliminate risk of breach or overflow of basins. o Two options discussed: • Emergency weir; and • Raising berm height to create more freeboard. • Condition L5 — Structural Integrity and Berm Stability Analysis. o Geotechnical investigation summarized in report; and o Full Geotechnical Investigation included as Appendix A. • Condition I.6 — Installation of Gauge to Monitor Waste Levels. o Coats has installed a gauge to monitor waste levels. If you have any comments or questions regarding this work directive, please contact Andre Lennon at 980-260-2045 or at alennon@cecinc.com. Sincerely, CIVIL & ENVIRONMENTAL CONSULTANTS, INC. Matthew Vranjes, P.E. Assistant Project Manager Andre Lennon, P.E. Senior Project Manager 3701 Arco Corporate Drive, Suite 400 I Charlotte, NC 28273 I p: 980-237-0373 f: 980-237-0372 I www.cecinc.com ENGINEERING REPORT COATS AMERICAN — SEVIER FACILITY OTHER NON -DISCHARGE WASTEWATER SYSTEM EVALUATION PREPARED FOR: COATS NORTH AMERICA — SEVIER PLANT MARION, NORTH CAROLINA PREPARED BY: CIVIL & ENVIRONMENTAL CONSULTANTS, INC. CHARLOTTE, NC CEC PROJECT 304-826 APRIL 2021 Ot% CA O; R 4 SEAL 6 ter; I Fr Civil & Environmental Consultants, Inc. Charlotte 3701 Arco Corporate Drive, Suite 400 1 Charlotte, NC 28273 I p: 980-237-0373 f: 980-237-0372 I www.cecinc.com Appendix A Appendix B Appendix C APPENDICES Geotechnical Engineering Report & Recommendations Engineering Drawings Site Photos Civil & Environmental Consultants, Inc. i Engineering Report April 2021 1.0 INTRODUCTION Coats North America operates a textile manufacturing facility located at 630 American Thread Road, Marion, McDowell County, North Carolina. Coats formerly operated coal-fired boilers resulting in Coal Combustion Residuals (CCR) that were wet -sluiced to CCR basins present at the facility. The CCR basins have not received CCR since the early 2000's. Coats previously received "closed -loop recycling system" permit authorizing wastewater treatment and disposal was not readopted by the Division of Water Resources of the Department of Environmental Quality (DWR) for the December 2019 renewal application. Coats North America filed a petition for a contested case in this matter relating to the issuance of the permit. Coats North America and DWR have agreed to terms of settlement based on the letter from DWR dated October 14, 2020. Civil & Environmental Consultants, Inc. 2 Engineering Report April 2021 2.0 CONDITIONS EVALUATION OF PERMIT OF PERMIT WQ0005603 2.1 CONDITION I.2 Condition I.2. — Immediately upon permit issuance, the Permittee shall install a temporary seal on all storm water piping present in both cells of the 4.7 acre unlined non -utility coal combustion ash storage basin to ensure that there is no point source discharge to surface water. Coats American, Inc. has installed temporary caps on piping that is exiting the cells of the basin to stop the point discharge of wastewater to surface waters. Photos of the capped outlet pipes are provided in Appendix C. 2.2 CONDITION I.3 Condition 1.3. — The Permittee shall submit to the Division a plan to permanently seal in place all storm water piping present in both cells of the 4.7 acre unlined non -utility coal combustion ash storage basin to ensure that there is no point source discharge to surface water. The plan shall include sufficiently specific design details for the basins and all piping and valves, including the construction materials and structural integrity of the basins and berms. This plan shall also include a proposed implementation schedule for the sealing of the piping. This plan shall be submitted to the Division for review and approval no later than April 30, 2021. Appendix B includes Engineering Drawings to show the plan to permanently seal in place all stormwater piping present in both cells of the basin to ensure that there is no point source discharge to surface waters. The piping will be filled with flowable fill and be capped at both ends. This will improve the structural integrity of the basins and berms by filling of the pipe voids. An implementation schedule is discussed below in section 2.3. Civil & Environmental Consultants, Inc. 3 Engineering Report April 2021 2.3 CONDITION I.4 Condition 1.4. — The Permittee shall examine alternative options for storage of the non -utility coal combustion ash deposits in the basin that would eliminate the risk of a breach or overflow. The Permittee shall investigate design alternatives and present an analysis of all options considered, along with proposed engineering plans and specifications, as well as proposed implementation schedules. This report shall be submitted to the Division for review and approval no later than April30, 2021. The following sections discuss the alternatives considered to eliminate risk of breach or overflow along with the recommended plan. Option 1: To mitigate the risk of a catastrophic overtopping of the existing basin CEC evaluated providing an emergency overflow weir at an elevation to safely discharge during a back to back 100 year 24 — hour storm event. This would allow a safe and controlled flow from the basin across a wide weir which acts as a level spreader. The weir and outer slope of the basin would be reinforced with matting to keep the soil stable. They both would also be reinforced with riprap for additional stability, and to act as a velocity disipator. Based on verbal direction received from NCDEQ, this option has been eliminated. Option 2: As an alternative to construction an emergency weir, CEC evaluated raising the height of the berm such that back to back 100 year 24-hour storm events are stored in the existing basin with freeboard. CEC's evaluation for the available storage is based on the as -built survey as provided by CEC of the existing basins with approximately 161,000 cubic feet of storage from bottom of basin to the top of berm. Based on the structural integrity evaluation of the existing slopes of the basin CEC recommends importing fill as discussed in Section 2.4 and maintaining the existing berm height. At this elevation the basin has the available capacity to store back to back 100 year 24-hour storm events with approxiamtely 1.4 ft of freeboard. Once word is received from DWR regarding an approved design direction, construction is anticipated to begin within one year. Civil & Environmental Consultants, Inc. 4 Engineering Report April 2021 2.4 CONDITION I.5 Condition I.S. — No later than two years of the date on this permit, the Permittee shall submit to the Division an Engineering Certification from a North Carolina licensed Professional Engineer on the structural integrity and berm stability of both cells of the 4.7 acre unlined non -utility coal combustion ash storage basin. An engineering evaluation of the structural integrity of the basins is provded in the Appendix A and is summarized below. Option 1: Extending the piping of the existing stormwater discharge and overbuilding slopes. This option increases the long term stability of the existing slopes. It would be proposed to overbuild all existing slopes to a minimum inclination of 3:1 (H:V). Fill soils would be brought to site to overbuild the slopes and be compacted as recommended in Appendix A. This option is minimally invasive and will not require major disturbance of the in -place coal ash. This option will however would require the installation of a piping system along the south side of the existing basin. Permitting of the extension of the stormwater outfall will be recommended to be performed in accordance with NCDEQ guidelines. Option 2: Excavating site slopes to decrease inclination. This option would be to lay existing slopes back to a minimum inclination of 3:1 (H:V). By decreasing the inclination of the slopes, the stability of those slopes would greatly increase promoting positive long-term performance. This option would however require extensive disturbance of the in -place coal ash as the slopes of the berm are layed back. Option 3: Installation of an earth retention system. This option would be to install an earth retention system to stabilize the existing slopes. The earth retention system would be designed so the slopes have a minimum factor of safety of 1.50. Option 3 has been eliminated as an option due to environmental and health concerns. Civil & Environmental Consultants, Inc. 5 Engineering Report April 2021 2.5 CONDITION I.6 Condition 1.6. — A gauge to monitor waste levels in the small/temporary storage cell of the inactive 4.7 acre unlined coal combustion ash storage basin shall be installed within 60 days of permit issuance. Coats American, Inc. has installed a gauge to monitor waste levels in the cells of the basin. Civil & Environmental Consultants, Inc. 6 Engineering Report April 2021 APPENDIX A GEOTECHNICAL ENGINEERING REPORT & RECOMMENDATIONS GEOTECHNICAL ENGINEERING REPORT American Thread — Slope Stability Analysis 630 American Thread Road Marion, North Carolina CVET Project No. 20-623 February 1, 2021 PREPARED FOR: Civil & Environmental Consultants 1900 Center Park Road, Ste A Charlotte, North Carolina 28217 PREPARED BY: CATAWBA VALLEY ENGINEERING AND TESTING, P.C. HICKORY, NORTH CAROLINA // GEOTECHNICAL • CONSTRUCTION MATERIALS • ENVIRONMENTAL <'• CATAWBA VALLEY ENGINEERING & TESTING PO Box 747 Hickory, NC 28603 308 15th St. SE Suite 2 Hickory, NC 28602 828 578 9972 0 828 322 1801 F NC Firm No. C-3833 SC Firm No. 5201 Geotechnical Engineering Environmental Services CMT/Special Inspections February 1, 2021 Mr. Matt Vranjes, PE Assistant Project Manager 3701 Arco Corporate Drive, Suite 400 Charlotte, North Carolina mvranjes@cecinc.com Re: Geotechnical Engineering Report American Thread - Slope Stability Analysis 630 American Thread Road Marion, McDowell County, North Carolina CVET Project No.: 20-623 Dear Mr. Vranjes: Catawba Valley Engineering and Testing (CVET) is pleased to submit to you our Geotechnical Engineering Report for the American Thread Slope Stability project located at 630 American Thread Road in Marion, North Carolina. This study was authorized on December 8, 2020. This report presents the findings of our subsurface exploration and provides geotechnical recommendations for remedial repairs and maintenance for the project. CVET appreciates the opportunity to provide our geotechnical engineering services for this project. If you have any questions regarding the contents of this report, or if we can provide additional services for the project such as construction materials testing and/or special inspections, please do not hesitate to contact us. Sincerely, CATAWBA VALLEY ENGINEERING AND TESTI Cody B. Dobbins, E.I. Project Manager ice' 041419 ; '' tt4 ` David Prin .al Engineer NC 041419 ., P.E. Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 TABLE OF CONTENTS 1.0 PURPOSE AND SCOPE OF WORK 1 2.0 PROJECT INFORMATION 1 3.0 EXPLORATION PROCEDURES 1 3.1 Field Exploration 2 3.2 Laboratory Testing 3 4.0 SUBSURFACE CONDITIONS 3 4.1 Site Geology 3 4.2 Soils 4 4.3 Partially Weathered Bedrock and Auger Refusal 4 4.4 Groundwater 5 5.0 RECOMMENDATIONS FOR REMEDIAL DESIGN AND MAINTENANCE 5 5.1 Undocumented Fill and Associated Risks 6 5.2 Slope Stability Analysis 6 6.0 LIMITATIONS 8 APPENDIX A — PROJECT FIGURES APPENDIX B — BORING LOGS iv APPENDIX C — LABORATORY TEST RESULTS v APPENDIX D — SLOPE STABILITY PROFILES vi ii Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 1.0 PURPOSE AND SCOPE OF WORK The purpose of the subsurface exploration and geotechnical engineering evaluation was to explore the subsurface conditions at the site, collect representative samples of soil for examination and testing in our laboratory, evaluate the slope stability of the subject area, and provide conclusions and recommendations for remedial repairs and maintenance of the associated slopes at the site in Marion, North Carolina. CVET's scope of work included the following: • Drilling of seven (7) SPT soil test borings at the site; • Pushing of three (3) CPT test sounding at the site; o And two (2) offset borings; • Installation of three (3) temporary piezometers; • Collection of three (3) Shelby Tubes; • Collection of three (3) Bulk Samples; • Collection of representative samples of soil from the soil test borings; • Classification of collected soil samples; • Laboratory testing of collected soil samples; • Preparation of boring logs, boring location plan, and general subsurface profile; • Evaluation of the encountered subsurface conditions at the site; and • Preparation of this geotechnical report. 2.0 PROJECT INFORMATION This project consists of the evaluation of the current stability of several existing slopes at the subject site in Marion, North Carolina. The area of evaluation extends approximately 1,080 linear feet along the man-made dams of a previously abandoned coal ash basin. No compaction records of the subject fill slopes are available at the time of this report; therefore, we consider this slope to be constructed of undocumented fill soils. Topographic information, provided by Civil Environmental Consultants, reveals that the subject slopes have current inclinations ranging from approximately 1.07:1 to 2.75:1 (H:V) and have vertical relief ranging from approximately 7 to 15 feet. 3.0 EXPLORATION PROCEDURES Exploration procedures for this project included drilling and pushing test borings at the site, laboratory testing of representative soil samples at our laboratory in Hickory, North Carolina, and laboratory testing of representative soil samples at T.E.S.T Laboratory in Tucker, Georgia. 1 Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 3.1 Field Exploration The subsurface conditions at the site were explored by drilling seven (7) Standard Penetration Test (SPT) soil borings (denoted B-1, B-3, B-10, B-12, B-15, B-17 and B-18), pushing three (3) Cone Penetration Test (CPT) sounding (denoted B-2, B-11, and B-16) and two (2) offset CPT borings (denoted B-11A and B-16A) at the locations indicated on Figure 2 — Boring Location Plan in Appendix A. The borings were performed on December 22, 2020 through December 29, 2020. Boring depths ranged from approximately 20.0 to 53.9 feet below existing site grades. The boring locations were selected and located in the field by CVET using existing site features as a reference. Ground elevations at the boring locations and other points of interest were estimated from the topographical information provided by CEC. The boring locations shown on Figure 2 and 3; plus the boring logs should be considered approximate. SPT drilling was performed with a Geoprobe 7822DT atv-mounted drill rig using continuous -flight hollow stem augers (HSA). Soil samples were obtained by means of the split -barrel sampling procedures, performed in general accordance with ASTM D1586. A 2-inch O.D., split -barrel sampler was driven into the soil a distance of 18 inches by means of an automatic hammer. The number of blows required to drive the sampler through the final 12-inch interval is termed the Standard Penetration Test (SPT) "N" value and is indicated for each sample on the boring logs. Representative portions of each SPT sample were sealed in airtight containers and returned to our laboratory for classification, testing, and storage. See the individual soil test boring logs in Appendix B for more details. Note that the soil samples will be discarded after 60 day from this report date, unless otherwise directed by CEC. CPT soundings were performed with a Geoprobe 7822DT atv-mounted drill rig anchored to the ground surface. The CPT soundings were performed in general accordance with ASTM D5778. The cone used in the sounding has a tip area of 10cm2 and a sleeve area of 150 cm2. The CPT soundings recorded tip resistance, sleeve friction, and pore water pressure measurements to assist in estimating index and engineering properties of the site soils and the depth to subsurface water at the sounding location. The ratio of the sleeve friction to tip resistance is then used to aid in assessing the soil types through which the tip is advanced. A total of three (3) thin -walled Shelby Tube were advanced in borings B-2, B-11 and B-16 to depths ranging from approximately 8.0 to 22.5 feet below existing site grades. The direct push specimen is collected in an acetate tube inside a thin -walled tube sampler, sealed, and returned to the laboratory for strength parameter testing. A total of three (3) bulk soil samples were obtained from borings B-5, B-11 and B-16 at depths ranging from approximately 0.0 to 3.0 feet, 10.0 to 15.0 feet, and 20.0 to 25.0 feet 2 Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 below existing site grades, respectively. The bulk soil specimens were collected in 5-gallon buckets, sealed, and returned to the laboratory for strength parameter testing. 3.2 Laboratory Testing Upon completion of the field exploration the SPT samples, undisturbed Shelby Tube specimen, and bulk samples were transported to CVET's laboratory in Hickory, North Carolina where they were examined and classified by a geotechnical engineer. The soil samples were visually classified in general accordance with the Unified Soil Classification System (USCS) per ASTM D2487. Laboratory testing for this portion of the study consisted of Soil Moisture Content (ASTM D2216), Grain Size Distribution (ASTM D422), Atterberg limits for plasticity (ASTM D4318), and Specific Gravity testing (ASTM D854). Moisture -density relationship testing was also performed in accordance with ASTM D698 to determine maximum dry density and optimum moisture content of the bulk soil samples. Unconfined Compressive Strength (ASDM D2166) testing was performed on representative portions of the bulk samples remolded to 95 percent of the standard Proctor maximum dry density. Consolidated-Undrained Triaxial compression testing was performed on representative portions of the Shelby Tube specimens in general accordance with ASTM D4767. UCS and Consolidated-Undrained Triaxial compression testing was performed by T.E.S.T. Laboratories in Tucker, GA. Results are presented and discussed in Section 6.2 Slope Stability Analysis. Laboratory results are included in Appendix c. 4.0 SUBSURFACE CONDITIONS The subsurface conditions at the site are described in the following paragraphs. 4.1 Site Geology The site is located in the Blue Ridge Physiographic Province of North Carolina. Located in the western portion of the state, this province is a deeply dissected mountainous area with numerous steep mountain ridges, intermountain basins, and trench valleys that intersect at various angles. The Blue Ridge consists primarily of complexly folded and faulted igneous and metamorphic rocks, which date to the Precambrian and Paleozoic eras and represent parts of the basement rock of the North American continent. Due to the continued chemical and physical weathering of igneous and metamorphic rock, the Blue Ridge Province is typically covered with a mantle of soil that was weathered in place from parent bedrock. These soils vary in thickness and are referred to as residuum or residual soils. The boundary between soil and rock is typically not sharply defined. "Partially weathered rock" (PWR) is the transitional zone found overlying bedrock. PWR 3 Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 is defined for engineering purposes as residual material with SPT values (N-values) exceeding 100 blows per foot (bpf). Groundwater in the Blue Ridge Province is typically fracture flow within the bedrock and under water table conditions in the soil overburden. Based on the 1985 North Carolina Geologic map, the site appears to be underlain by Muscovite, Biotite Gneiss. 4.2 Soils A subsurface profile has been prepared for the project — Figure 3 Subsurface Diagram which is included in Appendix A. Individual SPT and CPT logs are included in Appendix B. All soil test borings encountered existing, undocumented fill soils, including coal ash, to depths ranging from approximately 8.0 to 26.0 feet below existing site grades. The undocumented fill soils consist of sandy fat clay (CH), sandy elastic silt (MH) and sandy silt (ML) with inclusions of organic materials, and rock fragments. SPT N-values within the undocumented fill soils ranges from 0 to 10 blows per foot (bpf), indicating very soft to stiff. CPT soundings indicate tip pressure within the undocumented fill soils to range from 1.97 to exceeding 100.0 tons per square foot (tsf). Alluvial soils were encountered in soil test boring B-12 at the existing ground surface and boring B-15.0 at a depth of approximately 6.0 feet below existing site grades. The alluvium mainly consists of wet sandy elastic silt (MH) and sandy fat clay (CH). SPT-N values within the alluvium range from 0 to 8 bpf, indicating very soft to medium stiff. Residual soils were encountered in all soil test borings underlying the existing undocumented fill soils and the alluvium. The residuum mainly consists of wet, sandy silt (ML) and sandy elastic silt (MH). SPT N-values within the residuum ranges from 0 to 50 bpf indicating very soft to very hard soil consistencies. CPT soundings indicate tip pressure within the undocumented fill soils to range from 10.0 to exceeding 100.0 tons per square foot (tsf). 4.3 Partially Weathered Bedrock and Auger Refusal Partially weathered bedrock (PWR) was encountered in borings B-1, B-15, and B-18 at depths ranging from approximately 48.5 to 53.5 feet below existing site grades. Refusal conditions were encountered in the same soil test borings at depths ranging from approximately 48.75 to 53.9 feet below existing site grades. 4 Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 4.4 Groundwater Groundwater was encountered in all test borings performed as a part of this exploration at depths ranging from approximately 4.3 feet to 17.0 feet below existing site grades at either the time of drilling (ATD), end of drilling operations (EOD), or after drilling operations. The table below details the depths at which groundwater was encountered in each boring. Boring Number Water Depth EOD (ft.) Water Elevation Measured 1/22/21 (ft.) Cave Depth (ft.) B-1 9.0 --- 9.0 B-2* --- 6.5 --- B-3 5.5 --- 13.9 B-10 15.0 --- 37.0 B-11 * --- 15.5 --- B-12 7.7 --- 18.6 B-15 8.5 --- 34.7 B-16* --- 17.0 --- B-17 10.9 --- 28.8 B-18 4.3 --- 33.0 *Monitoring Wells Installed in these borings Note that boreholes were left open for only a short period of time during the drilling operation, so the detection of groundwater during this brief period is difficult. Also note that soil moisture and groundwater conditions vary depending on conditions such as temperature, precipitation and season. Therefore, soil moisture and groundwater location at other times of the year may vary from those observed at the time of this subsurface exploration and as described in this report. Temporary piezometers were installed in borings B-2, B-11 and B-16. The borehole cave-in depths ranged from 9.0 to 37.0 feet below existing site grade. The borehole cave-in depths are listed on the boring logs. In this geology, the cave-in depth of a boring is sometimes an indication of the stabilized water level, although the water level may be a few feet below the cave-in depth and therefore cannot be directly observed. 5.0 RECOMMENDATIONS FOR REMEDIAL DESIGN AND MAINTENANCE The following recommendations and conclusions are provided for the American Thread Slope Stability project located at 630 American Thread Road in Marion, North Carolina. The recommendations stated herein shall not be applied to any other project, or used in conjunction with any other recommendation, and shall be used explicitly for this project. 5 Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 5.1 Undocumented Fill and Associated Risks The soil test borings extended for this subsurface exploration encountered undocumented fill and/or alluvial soils to depths ranging from approximately 20.0 to 32.0 feet below existing site grades. Uncontrolled fill and alluvial soils encountered during a geotechnical engineering exploration present unique challenges unlike issues associated with residual soil deposits. Soft clay, peat, loose sand, and hard highly plastic clay can all be characterized reasonably well by proper exploration and testing techniques, knowledge of geologic conditions, and local experience. However, by definition, uncontrolled fills can range from compacted engineered fills where no construction records exist, to a heterogeneous mix of soil types, organics, cobbles, boulders, construction debris, building rubble, trash, industrial waste, and contaminants. In some limited cases, properly engineered fills can be sampled and tested and their shear strength and compressibility determined for design purposes. However, no practical amount of exploration and testing can be attempted to try to characterize the shear strength and compressibility for the wide range of deleterious materials found in most uncontrolled fill soils. As a result, in order to mitigate the risk of a slope failure, geotechnical engineers typically recommend that these unacceptable fill soils be not be included within mass fill sections. The magnitude of settlement or subsidence of undocumented fill soil with the inclusions of organic materials cannot be accurately predicted and is a function of time rate of decomposition of the organic material. Undocumented fill/alluvial soil poses an unquantifiable degree of risk associated with potential for settlement related distress and/or slope failure. As a result of the extent of the unsuitable undocumented fill soils, we conclude that the risks from these materials could lead to slope failure if remedial repairs are not implemented. 5.2 Slope Stability Analysis Topographic information, provided by Civil Environmental Consultants, reveals that the subject slopes have current inclinations ranging from approximately 1.07:1 to 2.75:1 (H:V) and have vertical relief ranging from approximately 7 to 15 feet. Based upon the inclination and vertical relief indicated on the topographic plan, CVET generated three (3) representative cross sections for slope stability analyses of the subject embankments. Scenario 1 was performed along the array of borings including B-1, B-2, and B-3; Scenario 2 was performed along the array of borings including B-10, B-11, and B-18; and Scenario 3 was performed along the array of borings including B-15, B-16, and B-17. The various scenarios account for the changes in slope inclination, the water table, and depth to residual site soils. 6 Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 Soil strength parameters for the existing coal ash material was developed through interpretation of the Consolidated-Undrained Triaxial compression testing (ASTM D4767) performed on the undisturbed Shelby tube soil specimen obtained from boring B-2 (sample from 8.0 to 10.5 feet), the remolded specimen obtained from the bulk sample at boring B-5 (sample from 0.0 to 3.0 feet), and the Unconfined Compression Strength (ASTM D2166) testing performed on the same specimens from B-2 and B-5. The soil strength parameters for the existing fill soils was developed through interpretation of the Consolidated-Undrained Triaxial compression testing (ASTM D4767) performed on the undisturbed Shelby tube soil specimen obtained from boring B-11 (sample from 15.0 to 17.5 feet) and the remolded specimen obtained from the bulk sample at boring B-11 (10.0 to 15.0 feet), and the Unconfined Compression Strength (ASTM D2166) testing performed on the same specimens from B-2 and B-5. Residual Site Soils and Partially Weathered Bedrock strength parameters were estimated from the SPT and CPT data collected at the site. The strength parameters were input in both total and effective strength conditions, depending on the level of the water table determined during our exploration. We conclude that the scenarios noted above provide a clear depiction of the current conditions at the site. Note that factors of safety provide a quantitative indication of slope stability. A value of FS = 1.0 indicates that a slope is on the boundary between stability and instability. Criterion obtained from the U.S. Army Corps of Engineers' Slope Stability Manual indicates required factors of safety of 1.3 (end of construction) to 1.5 (long-term) are acceptable for reliably predicting the behavior of the slope under assumed soil parameters, slope dimensions, and anticipated loading conditions. The following table summarizes the parameters used for the slope stability analyses. Coal Ash Material — Black Stratum Wet Density (pcf) 91.7 Dry Density (pcf) 67.7 Total Stress Friction Angle (degrees) 15.0 Effective Stress Friction Angle (degrees) 15.0 Total Stress Cohesion (psf) 0 Effective Stress Cohesion (psf) 0 Specific Gravity 1.50 Unconfined Compression Strength (psi) 5.4 Existing Fill Soil — Green Stratum Wet Density (pcf) 120.5 Dry Density (pcf) 92.3 Total Stress Friction Angle (degrees) 14.0 Effective Stress Friction Angle (degrees) 18.0 Total Stress Cohesion (psf) 0 Effective Stress Cohesion (psf) 0 7 Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 Specific Gravity 2.6 Unconfined Compression Strength (psi) 6.0 Alluvial Site Soil — Gray Stratum Wet Density (pcf) 121.9 Dry Density (pcf) 102.0 Total Stress Friction Angle (degrees) 15.5 Effective Stress Friction Angle (degrees) 27.3 Total Stress Cohesion (psf) 0 Total Stress Cohesion (psf) 0 Specific Gravity 2.7 Unconfined Compression Strength (psi) - Residual Site Soil — Peach Stratum Wet Density (pcf) 125.0 Dry Density (pcf) 110.0 Total Stress Friction Angle (degrees) 28 Effective Stress Friction Angle (degrees) 30 Total Stress Cohesion (psf) 0 Effective Stress Cohesion (psf) 0 Specific Gravity 2.75 Based upon the results of our slope stability analyses, we conclude that the existing slopes have an in place factor of safety ranging from approximately 0.2 to 1.43 assuming that no changes in stress states occur. Based upon the observations and the results of our analysis we recommend that an allowance for yearly inspections and stability analyses be incorporated into the maintenance budget. We also recommend that an allowance for surficial slope repairs be incorporated in the maintenance budget so that the risks associated with significant slope failure is minimized. One of the biggest threats to adequate slope stability is poor control of surface water, especially if it is allowed to flow over the slope. We recommend diverting surface water away from permanent site slopes. Temporary excavation support shall be performed in accordance with OSHA 1926 Subpart P. CVET should be allowed to review the final layout for the development and make revisions or additional recommendations for temporary shoring, if necessary. Based upon visual classification, we recommend that OSHA soil classification Type C is recommended during sloping and benching configurations for this project. 6.0 LIMITATIONS This report has been prepared for the exclusive use of the CEC and their agents for specific application to the referenced property, in accordance with generally accepted soils and foundation engineering practices. No warranties, express or implied, are 8 Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 intended or made. The conclusions and recommendations presented in this report are based on the specific test borings and laboratory testing performed as part of our scope of work, and do not reflect variations in subsurface conditions that may exist between test boring locations or in unexplored portions of the site. Note that the soil data presented in this report is for the specific time of this subsurface exploration. While the type of material encountered in the test borings will not likely change significantly over time, the properties of the materials can and will change over time, including soil moisture content, density, consistency, SPT"N" values, etc. Fluctuations in the groundwater level can have a significant impact on the material properties, as can seasonal changes. Site safety, excavation support related to OSHA requirements, and construction dewatering requirements are the responsibility of others, not CVET. In the event changes are made to the proposed construction plans, design or location of the project as described within this report, the conclusions and recommendations provided in this report shall not be considered valid unless CVET is given the opportunity to review the changes, and either verifies or modifies the conclusions and recommendations contained in this report in writing. 9 Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 APPENDIX A - PROJECT FIGURES iii PROJECT AREA z_ z 8 jimekHnCteek— - s z 1111 SCHEMATIC 0 Csi z M W � G N 0. a 0 LW LJ— z U_ 630 AMERICAN THREAD ROAD MARION, NORTH CAROLINA N PROJECT NO. z x w 0 630 AMERICAN THREAD ROAD MARION, NORTH CAROLINA Oci o SUBSURFACE DIAGRAM O) N H oS a) N N -O • 0) C > 0) m N r W c c co • co E N W N O • z C o J Q U 4) UC°2H PROJECT NAME American Thread CLIENT Civil & Environmental Consultants PROJECT NUMBER 00 co N 0 0 rn M O M 0 r M 0 M o 0 M COLCD CO co • • • • • • • • LO • • • • m O m m 0 0 0 rn CO O r co CO (u) uo!leA013 O m o CO CO Lo O M CO co 00 co 10 V M N O Distance Along Baseline (ft) fdee-idS 0V321HI NVOI 0V EZ9-0Z\S1O3f021d\-101NI9\A311N38\S1N3Wf1000\011811d\S213S11\ O - L9.51 lZ/l/Z -10`0 8V1 Sfl OlS 1NlO - 3ZIS V - MO 9 AHdVHDI1V2IIS Catawba Valley Engineering & Testing KEY TO SYMBOLS 161 Lenoir -Rhyne Blvd. SE Hickory NC 28602 E"G'"`ER'"G s TES""° Telephone: 828 578 9972 CLIENT Civil & Environmental Consultants PROJECT NAME American Thread PROJECT NUMBER 20-623 PROJECT LOCATION Marion, North Carolina LITHOLOGIC SYMBOLS (Unified Soil Classification System) SAMPLER SYMBOLS Split Spoon BEDROCK: Bedrock jCH: USCS High Plasticity Clay jCL: USCS Low Plasticity Clay ; I FILL: Fill (made ground) ttGW: USCS Well -graded Gravel ML: USCS Silt SC: USCS Clayey Sand WELL CONSTRUCTION SYMBOLS SM: USCS Silty Sand ',A iq:. ;T;.; . TOPSOIL: Topsoil ABBREVIATIONS LL - LIQUID LIMIT (%) TV - TORVANE PI - PLASTIC INDEX (%) PID - PHOTOIONIZATION DETECTOR W - MOISTURE CONTENT (%) UC - UNCONFINED COMPRESSION DD - DRY DENSITY (PCF) ppm - PARTS PER MILLION NP - NON PLASTIC Water Level at Time -200 - PERCENT PASSING NO. 200 SIEVE Drilling, or as Shown PP - POCKET PENETROMETER (TSF) w Water Level at End of - Drilling, or as Shown Water Level After 24 - Hours, or as Shown Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 APPENDIX B - BORING LOGS iv Catawba Valley Engineering & Testing 161 Lenoir -Rhyne Blvd. SE Hickory NC 28602 Telephone: 828 578 9972 CLIENT Civil & Environmental Consultants PROJECT NAME American Thread BORING NUMBER B1 PAGE 1 OF 1 PROJECT NUMBER 20-623 PROJECT LOCATION Marion, North Carolina DATE STARTED 12/23/20 COMPLETED 12/23/20 GROUND ELEVATION 1384 ft MSL HOLE SIZE 2.25 inches DRILLING CONTRACTOR CVET GROUND WATER LEVELS: DRILLING METHOD 2.25 Hollow Stem Auger AT TIME OF DRILLING --- LOGGED BY TS CHECKED BY DML 1 AT END OF DRILLING 9.00 ft / Elev 1375.00 ft Cave at 9.5 ft. NOTES AFTER DRILLING --- MATERIAL DESCRIPTION 0 >- >0 o w A SPT N VALUE A 20 40 60 80 PL MC LL 20 40 60 80 ❑ FINES CONTENT (%) ❑ 20 40 60 80 0 a- 0) W— aa z 0 z a uJ w 2 M co U w 0 d TOPSOIL (4 Feet) '/r SS 100 2-3-2 1 ,— (5) (ML) POSSIBLE RESIDUAL: Fine Sandy SILT with Trace Mica, Orangish Tan to Grey, Wet, Very Loose SS 100 1-0-1 2 (1) SS 100 1-2-2 3 ,— (4) SS 100 2-1-1 4 (2) 20 w m_ z w 2 0 0 0 J 7 a 0) UJ w U N 0 m J 0 0 0, 0 J a x m x U w 0 0 30 40 (SM) RESIDUAL: Silty Fine to Coarse SAND with Trace Angular Rock Fragments, Micaceous, Grey to Tan -Brown, Wet, Very Loose to Medium Dense SS 100 10-7-12 5 ,— (19) SS 100 4-4-2 6 (6) SS 100 2-0-1 7 (1) (SM) RESIDUAL: Silty Fine SAND, Tan -Brown with White, Wet, Very Loose to Loose SS 100 1-0-0 8 (0) ASS 100 3-3-5 9 (8) SS 100 0-0-0 10 �� (0) SS 100 0-0-0 11 �� (0) (ML) PARTIALLY WEATHERED BEDROCK: SILT STONE Refusal at 48.8 feet. Bottom of borehole at 48.8 feet. Y SS 100 50/3 I12 Catawba Valley Engineering & Testing BORING NUMBER B3 161 Lenoir -Rhyne Blvd. SE PAGE 1 OF 1 Hickory NC 28602 ENGINEERING ° .E°""° Telephone: 828 578 9972 CLIENT Civil & Environmental Consultants PROJECT NAME American Thread PROJECT NUMBER 20-623 PROJECT LOCATION Marion, North Carolina DATE STARTED 12/28/20 COMPLETED 12/28/20 GROUND ELEVATION 1383 ft MSL HOLE SIZE 2.25 inches DRILLING CONTRACTOR CVET GROUND WATER LEVELS: DRILLING METHOD 2.25 Hollow Stem Auger AT TIME OF DRILLING 5.50 ft / Elev 1377.50 ft Cave at 14.0 ft. LOGGED BY TS CHECKED BY DML AT END OF DRILLING --- NOTES AFTER DRILLING --- o DEPTH (ft) GRAPHIC LOG MATERIAL DESCRIPTION SAMPLE TYPE NUMBER RECOVERY (RQD) BLOW COUNTS (N VALUE) POCKET PEN. (tsf) DRY UNIT WT. (pcf) A SPT N VALUE A 20 40 60 80 MC PL�L 20 40 60 80 ❑ FINES CONTENT (%) ❑ 20 40 60 80 _ 5 (CH) FILL: Sandy CLAY with Inclusions of Coal Ash and Fine Mica, Trace Root Fragments, Grey, Black, Brown, Moist to Wet, Very Soft 2 A A , , \/ n SS 1 100 1-0-0 (0) SS 2 100 0-0-0 (0) 10 X3S 100 0-00-0 / (CL) RESIDUAL: Sandy CLAY with Angular Rock Fragments, Brown, Grey, Wet, Very Stiff \ / X 4S 100 1(00j0 X S5 100 1 (20) 8 115 - 20 (SC) RESIDUAL: Clayey SAND with Small Angular Rock Fragments, Brown, Grey, Wet, Loose to Medium Dense x SS 6 100 968 (14) - 25 X SS 7 100 1-2-5 (7) - - - 30 (ML) RESIDUAL: Fine Sandy SILT, with Angular Rock Fragments, Brown, Grey, Tan, Moist, Medium Stiff to Very Hard X SS 8 100 3-3-3 (6) 35 SS 9 100 6-23-32 (55) 40 SS 10 100 25-49-29 (78) Bottom of borehole at 40.0 feet. Catawba Valley Engineering & Testing 161 Lenoir -Rhyne Blvd. SE Hickory NC 28602 Telephone: 828 578 9972 CLIENT Civil & Environmental Consultants PROJECT NAME American Thread BORING NUMBER B10 PAGE 1 OF 1 PROJECT NUMBER 20-623 PROJECT LOCATION Marion, North Carolina DATE STARTED 12/29/20 COMPLETED 12/29/20 DRILLING CONTRACTOR CVET DRILLING METHOD 2.25 Hollow Stem Auger LOGGED BY TS CHECKED BY DML NOTES GROUND ELEVATION 1390 ft MSL HOLE SIZE 2.25 inches GROUND WATER LEVELS: AT TIME OF DRILLING --- AT END OF DRILLING 15.00 ft / Elev 1375.00 ft Cave at 37.0 ft. AFTER DRILLING --- a 0 0 =c� a0 � J cD MATERIAL DESCRIPTION c �w W^ wm wa an 0>2 < w CO A SPT N VALUE A w 20 40 60 80 o_ PL MC LL w w Z U } 20 40 60 80 O 0 ❑ FINES CONTENT (%) ❑ 20 40 60 80 0 a- 0) 0 W- cc z 10 z a uJ w 2 M co 0 w 0 g z w 2 0 0 0 0 J 7 a 0) uJ w 0 N 0 m J 0 0 0) 0 J a x m x 0 w 0 w 0 20 30 A 40 50 1 (CL) FILL: Coal Ash with Inclusions of Sandy CLAY, Small Rock Fragments, Black, Brown, Wet, Very Soft (CL) RESIDUAL: Sandy CLAY with Small Angular Rock Fragments, Micaceous, Dark Grey, Black, Brown, Wet, Very Soft to Medium Stiff (ML) RESIDUAL: Sandy SILT with Angular Rock Fragments, Brown to Grey, Wet, Very Stiff to Hard Bottom of borehole at 50.0 feet. SS 100 0-0-0 1 (0) SS 100 0-0-0 2 (0) SS 100 2-1-1 3 (2) SS 100 1-0-0 4 (0) SS 100 0-0-0 5 (0) SS 100 3-1-1 6 (2) SS 100 3-3-3 7 (6) SS 100 3-3-1 8 (4) SS 100 2-1-1 sk 9 (2) SS 100 22-10-17 10 ,- (27) YI SS 100 17-12-7 11 ,- (19) S2 100 ` 25-15-25 (40) , A A A Catawba Valley Engineering & Testing 161 Lenoir -Rhyne Blvd. SE Hickory NC 28602 Telephone: 828 578 9972 CLIENT Civil & Environmental Consultants PROJECT NAME American Thread BORING NUMBER B12 PAGE 1 OF 1 PROJECT NUMBER 20-623 PROJECT LOCATION Marion, North Carolina DATE STARTED 12/29/20 COMPLETED 12/29/20 DRILLING CONTRACTOR CVET DRILLING METHOD 2.25 Hollow Stem Auger LOGGED BY TS CHECKED BY DML GROUND ELEVATION 1388 ft MSL HOLE SIZE 2.25 inches GROUND WATER LEVELS: AT TIME OF DRILLING --- AT END OF DRILLING 7.70 ft / Elev 1380.30 ft Cave at 18.7 ft. NOTES AFTER DRILLING --- U a0 � J cD MATERIAL DESCRIPTION A SPT N VALUE A w 20 40 60 80 o_ PL MC LL w w Z a U } 20 40 60 80 O o ❑ FINES CONTENT (%) ❑ 20 40 60 80 0 a 0) 0 W- cc z 10 z 0 U w 2 M 0 U w 0 d z >- w J z w 2 0 0 0 0 J 7 a 0) uJ w U N 0 m J 0 U 0) 0 J a x m x U w 0 w 0 20 (CH) ALLUVIAL: Sandy Fat CLAY with Trace of Mica, Brown, Grey, Black, Wet, Very Soft 1 j 30 40 50 (CL) RESIDUAL: Sandy CLAY with Small Angular Rock Fragments, Grey, Dark Grey, Wet, Medium Stiff to Hard (ML) RESIDUAL: Sandy SILT with Angular Rock Fragments, Brown, Wet, Very Soft to Hard Bottom of borehole at 50.0 feet. SS 100 0-0-0 1 _ (0) SS 100 0-0-0 2 (0) SS 100 0-0-0 3 (0) SS 100 0-0-0 4 (0) • SS 100 14-12-25 5 ,- (37) SS 100 4-4-2 6 (6) SS 100 2-1-1 7 (2) SS 100 1-2-2 8 p; (4) ASS 100 0-0-0 9 (0) SS 100 1-4-1 10 ,- (5) SS 100 8-4-2 11 ,- (6) S2 100 ` 25-11-34 (45) A A A Catawba Valley Engineering & Testing 161 Lenoir -Rhyne Blvd. SE Hickory NC 28602 Telephone: 828 578 9972 CLIENT Civil & Environmental Consultants PROJECT NAME American Thread BORING NUMBER B15 PAGE 1 OF 1 PROJECT NUMBER 20-623 PROJECT LOCATION Marion, North Carolina DATE STARTED 12/29/20 COMPLETED 12/29/20 GROUND ELEVATION 1392 ft MSL HOLE SIZE 2.25 inches DRILLING CONTRACTOR CVET GROUND WATER LEVELS: DRILLING METHOD 2.25 Hollow Stem Auger AT TIME OF DRILLING --- LOGGED BY TS CHECKED BY DML NOTES 1 AT END OF DRILLING 8.50 ft / Elev 1383.50 ft Cave at 34.7 ft. AFTER DRILLING --- MATERIAL DESCRIPTION w �w m _1g a Qz >— w >0 o— w A SPT N VALUE A w 20 40 60 80 PL MC LL w w z a U } 20 40 60 80 a o ❑ FINES CONTENT (%) ❑ 20 40 60 80 0 a w cc w 2 M 0 w 0 cc g z>- J w m z w 0 0 0 — 0_ a (/)- 0 11) 0 0 J 0 z z 0, 0 J co x 0 0 w 0 NO RECOVERY (Appeared to be Saturated Coal Ash) SS 100 0-0-0 1 , (0) — SS 100 0-0-0 (0) (MH) FILL: Sandy Elastic SILT with Fine Mica and Rock Fragments, Orange -Brown, Grey, black, Wet, Very Soft to Medium Stiff (GW) ALLUVIAL: Sandy Gravel, Grey, Wet, Loose X SS 100 3 0-0-0 (0) X SS 100 0-0-0 /\ 4 , (0) XSS 100 2-1-1 5 , (2) SS 100 2-1-2 6 /—\ (3) X SS 100 7-6-2 /\ 7 ,— (8) (ML) RESIDUAL: Sandy SILT with Angular Rock Ragments, Brown, Grey, Tan, Wet, Soft to Very Stiff 40 50 X SS 100 7-6-4 /\ 8 /—\ (10) /X SS 100 1-2-6 \ 9 ,— (8) • SS 100 3-2-2 10 ,— (4) SS 100 0-0-3 11 ,— (3) SS 100 12 , 16-14-8 (22) Bottom of borehole at 53.9 feet. SS 100 50/5" 13 A A A Catawba Valley Engineering & Testing BORING NUMBER B-16 161 Lenoir -Rhyne Blvd. SE PAGE 1 OF 1 Hickory NC 28602 ENGINEERING ° .E°""° Telephone: 828 578 9972 CLIENT Civil & Environmental Consultants PROJECT NAME American Thread PROJECT NUMBER 20-623 PROJECT LOCATION Marion, North Carolina DATE STARTED 12/28/20 COMPLETED 12/28/20 GROUND ELEVATION 1396 ft MSL HOLE SIZE 2.25 inches DRILLING CONTRACTOR CVET GROUND WATER LEVELS: DRILLING METHOD 2.25 Hollow Stem Auger AT TIME OF DRILLING --- LOGGED BY TS CHECKED BY DML AT END OF DRILLING --- NOTES AFTER DRILLING --- o DEPTH (ft) GRAPHIC LOG MATERIAL DESCRIPTION SAMPLE TYPE NUMBER RECOVERY (RQD) BLOW COUNTS (N VALUE) POCKET PEN. (tsf) DRY UNIT WT. (pcf) A SPT N VALUE A 20 40 60 80 PL�L MC 20 40 60 80 ❑ FINES CONTENT (%) ❑ 20 40 60 80 11501 ♦i♦i♦i♦ ♦iii♦ O♦00 %i ItJ♦i♦i♦i♦ • • FILL: Coal Ash, with Traces of Sandy Fat CLAy, Rock Fragments, Black with White Inclusions, Dark Red -Brown, Dry to Moist, Very Loose to Loose 100 SS 2 100 6-5-3 (8) _ X SS 3 100 5-2-1 (3) SS 4 100 2-2-2 (4) 15 (MH) POSSIBLE FILL: Sandy Elastic SILT with Trace Rock Fragments, Dark Red -Brown, Wet, Very Loose XSS 5 100 0-0-0 (0) 20 )(SS 6 100 0-0-0 (0) Bottom of borehole at 20.0 feet. Catawba Valley Engineering & Testing 161 Lenoir -Rhyne Blvd. SE Hickory NC 28602 Telephone: 828 578 9972 CLIENT Civil & Environmental Consultants PROJECT NAME American Thread BORING NUMBER B17 PAGE 1 OF 1 PROJECT NUMBER 20-623 PROJECT LOCATION Marion, North Carolina DATE STARTED 12/23/20 COMPLETED 12/23/20 GROUND ELEVATION 1389 ft MSL HOLE SIZE 2.25 inches DRILLING CONTRACTOR CVET GROUND WATER LEVELS: DRILLING METHOD 2.25 Hollow Stem Auger AT TIME OF DRILLING --- LOGGED BY TS CHECKED BY DML NOTES 1 AT END OF DRILLING 10.90 ft / Elev 1378.10 ft Cave at 20.9 ft. AFTER DRILLING --- MATERIAL DESCRIPTION cD A SPT N VALUE A 20 40 60 80 PL MC LL 20 40 60 80 ❑ FINES CONTENT (%) ❑ 20 40 60 80 (MH) FILL: Sandy Elastic SILT, Red -Brown, Moist to Wet, Very Soft to Medium Stiff 0 a 0) W- cc z 10 z a w 2 M 0 U w 0 d z w 2 0 0 0 J 7 a 0) uJ w U N 0 0 J 0 (ML) RESIDUAL: Sandy SILT, Brown, Grey, Wet, Very Soft to Very Stiff 20 30 40 50 Bottom of borehole at 50.0 feet. SS 100 2-2-3 1 ,- (5) SS 100 2-2-1 2 ,- (3) SS 100 1-0-1 3 (1) SS 100 1-1-1 4 (2) SS 100 0-0-0 5 (0) SS 100 1-2-3 6 ,- (5) SS 100 1-1-2 7 ,- (3) SS 100 3-3-2 8 (5) 9S 100 3-1-1 (2) SS 100 2-0-1 10 (1) SS 100 4-3-4 11 ,- (7) S2 100 4-7-10 (17) Catawba Valley Engineering & Testing 161 Lenoir -Rhyne Blvd. SE Hickory NC 28602 Telephone: 828 578 9972 CLIENT Civil & Environmental Consultants PROJECT NUMBER 20-623 DATE STARTED 12/22/20 COMPLETED 12/22/20 DRILLING CONTRACTOR CVET DRILLING METHOD 2.25 Hollow Stem Auger LOGGED BY TS CHECKED BY DML NOTES BORING NUMBER B18 PAGE 1 OF 1 PROJECT NAME American Thread PROJECT LOCATION Marion, North Carolina GROUND ELEVATION 1380 ft MSL HOLE SIZE 2.25 inches GROUND WATER LEVELS: AT TIME OF DRILLING --- AT END OF DRILLING 4.25 ft / Elev 1375.75 ft Cave at 33.0 ft. AFTER DRILLING --- o_ 0 5 - 10 15 20 - 25 30 35 40 - 45 0 0 0-0 < cD MATERIAL DESCRIPTION (MH) FILL: Sandy Elastic SILT, Red -Brown, Moist to Wet, Very Soft to Soft (ML) RESIDUAL: Sandy SILT with Small Angular Rock Fragments, Brown, Grey, Tan, Wet, Very Soft to Very Hard w o-� �w m _1g o_ Qz co 0 >- >0 00 w SS 100 0-0-2 1 (2) SS 100 0-0-2 2 (2) SS 100 0-0-1 3 (1) SS 100 2-3-1 4 (4) SS 100 2-1-2 5 (3) SS 0 0-0-0 6 (0) SS 100 0-0-0 7 (0) SS 0 0-0-0 8 (0) SS 0 0-0-0 9 (0) SS 0 0-0-0 10 (0) SS 100 27-30-22 11 (52) z w 0_ w 0 0 o_ H w Z U a >- 0 A SPT N VALUE A 20 40 60 80 PL MC LL 20 40 60 80 ❑ FINES CONTENT (%) ❑ 20 40 60 80 A A A Bottom of borehole at 45.0 feet. 1 co Cone Penetration Test l4 U i az° U cN DO0 • o L E -c c O z L�.o �a O E Q N co Q O C L � Q QO C L 0. co a, 'a • V 4 R C E 9 9S 9 w 0 N c 0 U J 2 O O O O O O 0)0)C c c O co d O Z W dw W Equivalent N60 Pore Pressure L 0 O O O O 00 O CO O I 0 Clays -Clay to Silty Clay E -15 - 1 ' 1 ' ' 1 ' N N M 1 . 1 . . 1 . 0 0 0 0 cr 0 I — v 0 N N 1 co Electronic File Name: B-2.cpt O 1.Z/8Z4 100'8V1 Sll 012 d0 rdo'1dO OV32lHl NVON3INV EZ9-0Z bV 02lVONV.S - ld0 1 Ca Cone Penetration Test O O O Ea O Q . N � N • Q O C Q QO pp L 0. co Tfa H'a • V +; 63 C E S 0w v CI a)a)C C C • O co G) G) O Z W CO U i a- z° V C -0 0 9 •C L E 'a 7 C O Z L re O N w Equivalent N60 Pore Pressure CO O Clays -Clay to Silty Clay [ • • • • O LO LO ON N 0 O ao 0 1 Ca Electronic File Name: B-11.cpt 1.Z/8Z4 iaa'8V1 Sll O.S dO rdo'1dO OV32lHl NVON3INV EZ9-0Z bV 02lVONV.S -121Od321_WO ' B-11 offset Cone Penetration Test N O O O a)a)C C C O W GG)) Z W l4 U t i a- z° V C -0 0 9 EL) •c3 o E 'a 7 c 03 O z L r ,O O 13.) Equivalent N60 Pore Pressure C0 (7 N O O I.0 0 1.0 OMM - - CD I i I . . 1 , I . m C U d) F FT) o .a 0' 0 CZ n m 0 0 c ( Lco N N OM M V O 1.Z/8Z4 iaa'8V1 Sll O.S dO rdo'1dD OV32lHl NVON3INV EZ9-0Z bV 02lVONV.S -121Od3211dO Cone Penetration Test 9- ti co N t to G) .Cl) 0 'C G) C0 0 0 to C E d H J to 2 O O O O O O 0)0)C C C O W GG)) Z W to U t r az° V C N -0 0 `9 d •� L I E c 't3 7 03 0 z L 0 re O O E �a O Q _ N co 'i C L QO 12 oC m L 0. co 0) lz V C E 9 9itomo S 0 w v dw W Equivalent N60 Pore Pressure U) L cu O CO N c O 0 v co m co c 0 U— -0 co r O I0 0 O N N O O W 1 Ca Electronic File Name: B-16.cpt 1.Z/8Z4 iaa'8V1 Sll O.S dO rdo'ldO OV32lHl NVON3INV EZ9-0Z bV 02lVONV.S - ldO B-16 offset Cone Penetration Test U t i a- z° V C N -0 0 9 •C L I E 'a 7 C O z 1 O O re c\1 N d C 0 C.) O O O Pore Pressure 0 O 0 CD d (7 O O m ) N (1)- 2 0 o 0) Organic Soils, Pests Clays -Clay to Silty Clay O ▪ N N ▪ co it) V V O O CO O 1.Z/8Z4 laa vi Sll O1S dO rdo'1do OV32lHl NVON3INV EZ9-0Z bV 02lVONV.S -121Od321_WO Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 APPENDIX C - LABORATORY TEST RESULTS v TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 '1;1,+..T: Phone: 770-938-8233 rLAir Tested By EB/KP .11 Fax: 770-923-8973 Date 01/12/21 Web: www.test-11c.com Checked By ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # 2160-03-1 Pr. Name American Thread Sample Type Remold Sample ID 36975/B-11 Depth/Elevation 10-15' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION (initial) (final) Height, in 6.000 5.970 Mass of Wet Sample and Tare, g 315.40 1508.30 Diameter, in 2.875 2.842 Mass of Dry Sample and Tare, g 269.80 1234.25 Height -to -Diameter Ratio 2.1 2.1 Mass of Tare, g 81.20 298.90 Area, in` 6.49 6.34 Moisture, % 24.18 29.30 Volume, cm' 638.29 620.63 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 1161.50 1209.70 Mass of Dry Sample, g 935.35 935.58 Machine Speed, in / min 0.0100 Wet Density, pcf 113.6 121.7 Strain Rate, %/ min 0.17 Dry Density, pcf 91.5 94.1 Chamber Pressure, psi 83.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure,psi 80.0 Volume of Solids, cm' 346.43 346.51 Eff. Consol. Stress,(Minor pr. stress, a3),psi 3.0 Volume of Voids, cm' 291.86 274.12 Change in Height, in 0.030 Void Ratio 0.84 0.79 "B" Value 0.95 % Saturation 77.5 100.0 SHEAR DATA Elapsed Time (min) Deformation (inch) Axial Load (lb) Pore -Water Pressure,psi p Total Strain (%) Corrected Area (inz) Dev.Stress A =a -a ( 1 s) (psi) Major Principal Stress,psi p Eff.Stress Ratio a,/a 3 P' (a'1+a 3)/2 (psi) Q 7 [(a1-a3)/2] (psi) Eff. Minor Pr. Stress a'3 (psi) Total,U Change,4U Total a1 Eff. a'1 0.0 0.000 19 80.0 0.0 0.00 6.34 0.0 3.0 3.0 1.00 3.0 0.0 3.0 1.0 0.010 59.4 80.4 0.4 0.17 6.35 6.4 9.4 9.0 3.41 5.8 3.2 2.6 2.0 0.020 72.3 80.1 0.1 0.34 6.37 8.4 11.4 11.2 3.93 7.0 4.2 2.9 3.1 0.031 83.1 79.9 -0.1 0.51 6.38 10.0 13.0 13.2 4.22 8.1 5.0 3.1 4.1 0.041 92.0 79.6 -0.4 0.68 6.39 11.4 14.4 14.8 4.40 9.1 5.7 3.4 5.1 0.051 99.7 79.4 -0.6 0.85 6.40 12.6 15.6 16.2 4.50 9.9 6.3 3.6 7.1 0.071 110.5 79.0 -1.0 1.19 6.42 14.2 17.2 18.3 4.54 11.2 7.1 4.0 10.2 0.102 120.2 78.6 -1.4 1.71 6.45 15.7 18.7 20.1 4.54 12.3 7.8 4.4 12.2 0.122 124.0 78.4 -1.6 2.05 6.48 16.2 19.2 20.9 4.50 12.7 8.1 4.6 15.3 0.153 127.8 78.2 -1.8 2.56 6.51 16.7 19.7 21.5 4.49 13.2 8.4 4.8 17.3 0.173 129.8 78.1 -1.9 2.90 6.53 17.0 20.0 21.8 4.46 13.4 8.5 4.9 20.4 0.204 132.2 78.0 -2.0 3.41 6.57 17.2 20.2 22.2 4.46 13.6 8.6 5.0 24.5 0.245 135.0 77.9 -2.1 4.10 6.61 17.5 20.5 22.6 4.44 13.9 8.8 5.1 29.6 0.296 138.0 77.8 -2.2 4.95 6.67 17.8 20.8 23.1 4.40 14.2 8.9 5.2 35.7 0.357 141.7 77.6 -2.4 5.97 6.75 18.2 21.2 23.6 4.34 14.5 9.1 5.4 40.8 0.408 144.0 77.4 -2.6 6.83 6.81 18.4 21.4 23.9 4.30 14.7 9.2 5.6 45.9 0.459 146.0 77.3 -2.7 7.68 6.87 18.5 21.5 24.1 4.26 14.9 9.2 5.7 49.9 0.499 147.6 77.3 -2.7 8.36 6.92 18.6 21.6 24.3 4.24 15.0 9.3 5.7 60.1 0.601 151.5 77.1 -2.9 10.07 7.05 18.8 21.8 24.7 4.17 15.3 9.4 5.9 70.3 0.703 155.0 76.9 -3.1 11.78 7.19 18.9 21.9 25.0 4.11 15.5 9.5 6.1 80.5 0.805 158.5 76.8 -3.2 13.49 7.33 19.0 22.0 25.3 4.05 15.8 9.5 6.2 85.6 0.856 160.0 76.7 -3.3 14.34 7.41 19.0 22.0 25.4 4.02 15.8 9.5 6.3 89.9 0.899 161.9 76.6 -3.4 15.06 7.47 19.1 22.1 25.5 4.00 15.9 9.6 6.4 Values @ Failure -1.4 1.71 6.45 15.7 18.7 20.1 4.54 12.3 7.8 4.4 Failure criteria used* 3 'Note:"1"=Max Deviator Stress;"2"=Deviator Stress @ 15% Strain;"3"=Max Eff.Stress Ratio(a'i/a'3) Pnno 1 of 7 Triaxial CU.xls [AJ, REV. 1; 10-10-05 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 � re: S.I; Phone: 770-938-8233 I Tested By EB/KP IF Fax: 770-923-8973 Date 01/12/21 Web: www.test-Ilc.com ., ' 5 HT Checked By ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # 2160-03-1 Pr. Name American Thread Sample Type Remold Sample ID 36975/B-11 Depth/Elevation 10-15' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION initial) (final) Height, in 6.000 5.938 Mass of Wet Sample and Tare, g 315.40 1520.40 Diameter, in 2.875 2.852 Mass of Dry Sample and Tare, g 269.80 1245.74 Height -to -Diameter Ratio 2.1 2.1 Mass of Tare, g 81.20 309.50 Area, in 6.49 6.39 Moisture, % 24.18 29.34 Volume, cm' 638.29 621.47 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 1162.60 1211.00 Mass of Dry Sample, g 936.24 936.31 Machine Speed, in / min 0.0100 Wet Density, pcf 113.7 121.6 Strain Rate, % / min 0.17 Dry Density, pcf 91.6 94.1 Chamber Pressure, psi 86.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure,psi 80.0 Volume of Solids, cm' 346.75 346.78 Eff. Consol. Stress,(Minor pr. stress, a3),psi 6.0 Volume of Voids, cm' 291.54 274.69 Change in Height, in 0.062 Void Ratio 0.84 0.79 "B" Value 0.95 % Saturation 77.6 100.0 SHEAR DATA Elapsed Time (min) Deformation (inch) Axial Load (lb) Pore -Water Pressure,psi Total Strain (%) Corrected Area Ore) Dev.Stress (Da=a -as)Stress, (psi) Major Principal psi Eff.Stress Ratio a',/a'3 P (a 1+a'3)/2 (psi) Q [(a-a3)l2] (psi) Eff. Minor Pr. Stress a'3 (psi) Total,U Change,4U Total al Eff. a', 0.0 0.000 21.0 80.0 0.0 0.00 6.39 0.0 6.0 6.0 1.00 6.0 0.0 6.0 1.0 0.010 69.8 81.6 1.6 0.17 6.40 7.6 13.6 12.1 2.71 8.3 3.8 4.4 2.0 0.020 85.8 81.7 1.7 0.34 6.41 10.1 16.1 14.4 3.36 9.3 5.1 4.3 3.1 0.031 98.5 81.7 1.7 0.51 6.42 12.1 18.1 16.4 3.79 10.4 6.0 4.3 4.1 0.041 109.1 81.6 1.6 0.69 6.43 13.7 19.7 18.1 4.08 11.3 6.8 4.4 5.1 0.051 117.5 81.4 1.4 0.86 6.44 15.0 21.0 19.6 4.26 12.1 7.5 4.6 7.1 0.071 128.3 81.2 1.2 1.20 6.46 16.6 22.6 21.4 4.44 13.1 8.3 4.8 10.2 0.102 136.1 80.9 0.9 1.72 6.50 17.7 23.7 22.8 4.50 13.9 8.9 5.1 12.2 0.122 138.6 80.9 0.9 2.06 6.52 18.0 24.0 23.2 4.51 14.1 9.0 5.1 15.3 0.153 141.1 80.8 0.8 2.57 6.56 18.3 24.3 23.6 4.50 14.4 9.2 5.2 17.3 0.173 142.4 80.7 0.7 2.92 6.58 18.5 24.5 23.7 4.50 14.5 9.2 5.3 20.4 0.204 144.3 80.6 0.6 3.43 6.61 18.6 24.6 24.0 4.48 14.7 9.3 5.4 24.5 0.245 146.7 80.5 0.5 4.12 6.66 18.9 24.9 24.3 4.46 14.9 9.4 5.5 29.6 0.296 149.8 80.4 0.4 4.98 6.72 19.2 25.2 24.7 4.44 15.2 9.6 5.6 35.7 0.357 153.7 80.3 0.3 6.01 6.79 19.5 25.5 25.3 4.40 15.5 9.8 5.7 40.8 0.408 156.4 80.1 0.1 6.86 6.86 19.7 25.7 25.6 4.36 15.8 9.9 5.9 45.9 0.459 159.7 80.0 0.0 7.72 6.92 20.0 26.0 26.1 4.32 16.1 10.0 6.0 49.9 0.499 162.1 79.8 -0.2 8.41 6.97 20.2 26.2 26.4 4.28 16.3 10.1 6.2 60.1 0.601 167.7 79.6 -0.4 10.13 7.11 20.6 26.6 27.1 4.20 16.8 10.3 6.4 70.3 0.703 173.4 79.3 -0.7 11.84 7.24 21.0 27.0 27.7 4.16 17.2 10.5 6.7 80.5 0.805 178.3 79.1 -0.9 13.56 7.39 21.3 27.3 28.2 4.10 17.5 10.6 6.9 85.6 0.856 180.2 79.0 -1.0 14.42 7.46 21.3 27.3 28.3 4.06 17.6 10.7 7.0 90.0 0.900 182.1 79.0 -1.0 15.15 7.53 21.4 27.4 28.4 4.04 17.7 10.7 7.0 Values @ Failure 0.9 2.06 6.52 18.0 24.0 23.2 4.51 14.1 9.0 5.1 Failure criteria used* 3 `Note:"1"=Max Deviator Stress;"2"=Deviator Stress @ 15% Strain;"3"=Max Eff.Stress Ratio(a',/a'3) Page 2 of 7 TriaxialICU xls [B], REV 1; 10-10-05 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 � re: S.I; Phone: 770-938-8233 I Tested By EB/KP IF Fax: 770-923-8973 Date 01/12/21 Web: vvvvw.test-Ilc.com H di s c , 7 o Checked By ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # 2160-03-1 Pr. Name American Thread Sample Type Remold Sample ID 36975/B-11 Depth/Elevation 10-15' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION initial) (final) Height, in 6.000 5.935 Mass of Wet Sample and Tare, g 315.40 1507.50 Diameter, in 2.875 2.838 Mass of Dry Sample and Tare, g 269.80 1239.09 Height -to -Diameter Ratio 2.1 2.1 Mass of Tare, g 81.20 303.10 Area, in 6.49 6.33 Moisture, % 24.18 28.68 Volume, cm' 638.29 615.38 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 1162.30 1205.00 Mass of Dry Sample, g 935.99 936.46 Machine Speed, in / min 0.0100 Wet Density, pcf 113.7 122.2 Strain Rate, % / min 0.17 Dry Density, pcf 91.5 95.0 Chamber Pressure, psi 92.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure,psi 80.0 Volume of Solids, cm' 346.66 346.84 Eff. Consol. Stress,(Minor pr. stress, a3),psi 12.0 Volume of Voids, cm' 291.63 268.54 Change in Height, in 0.065 Void Ratio 0.84 0.77 "B" Value 0.95 % Saturation 77.6 100.0 SHEAR DATA Elapsed Time (min) Deformation (inch) Axial Load (lb) Pore -Water Pressure,psi Total Strain (%) Corrected Area Ore) Dev.Stress (Da=a -a3)Stress, (psi) Major Principal psi Eff.Stress Ratio a',/a'3 P' (a 1+a'3)/2 (psi) Q [(a-a3)l2] (psi) Eff. Minor Pr. Stress a'3 (psi) Total,U Change,4U Total al Eff. a', 0.0 0.000 23.5 80.0 0.0 0.00 6.33 0.0 12.0 12.0 1.00 12.0 0.0 12.0 1.0 0.010 81.4 83.1 3.1 0.17 6.34 9.1 21.1 18.0 2.03 13.5 4.6 8.9 2.0 0.020 99.4 84.1 4.1 0.34 6.35 12.0 24.0 19.8 2.52 13.9 6.0 7.9 3.1 0.031 112.5 84.6 4.6 0.52 6.36 14.0 26.0 21.4 2.89 14.4 7.0 7.4 4.1 0.041 122.8 84.8 4.8 0.69 6.37 15.6 27.6 22.7 3.18 15.0 7.8 7.2 5.1 0.051 130.5 85.0 5.0 0.86 6.38 J 16.8 28.8 23.8 3.38 15.4 8.4 7.0 7.1 0.071 141.9 85.0 5.0 1.20 6.40 18.5 30.5 25.4 3.66 16.2 9.2 7.0 10.2 0.102 153.3 85.0 5.0 1.72 6.44 20.2 32.2 27.2 3.87 17.1 10.1 7.0 12.2 0.122 157.6 84.9 4.9 2.06 6.46 20.8 32.8 27.9 3.91 17.5 10.4 7.1 15.3 0.153 161.8 84.9 4.9 2.58 6.49 21.3 33.3 28.4 3.98 17.8 10.6 7.1 17.3 0.173 163.6 84.8 4.8 2.92 6.52 21.5 33.5 28.7 3.99 17.9 10.7 7.2 20.4 0.204 165.7 84.7 4.7 3.43 6.55 21.7 33.7 29.0 3.99 18.1 10.8 7.3 24.5 0.245 167.8 84.6 4.6 4.12 6.60 21.9 33.9 29.2 3.97 18.3 10.9 7.4 29.6 0.296 169.7 84.6 4.6 4.98 6.66 22.0 34.0 29.4 3.96 18.4 11.0 7.4 35.7 0.357 172.0 84.5 4.5 6.01 6.73 22.1 34.1 29.5 3.95 18.5 11.0 7.5 40.8 0.408 174.3 84.5 4.5 6.87 6.79 22.2 34.2 29.7 3.95 18.6 11.1 7.5 45.9 0.459 176.4 84.4 4.4 7.73 6.86 22.3 34.3 29.9 3.95 18.7 11.2 7.6 49.9 0.499 177.8 84.4 4.4 8.41 6.91 22.3 34.3 29.9 3.94 18.8 11.2 7.6 60.1 0.601 182.3 84.4 4.4 10.13 7.04 22.6 34.6 30.2 3.96 18.9 11.3 7.6 70.3 0.703 186.5 84.3 4.3 11.85 7.18 22.7 34.7 30.4 J 3.95 19.1 11.4 7.7 80.5 0.805 190.7 84.2 4.2 13.57 7.32 22.8 34.8 30.7 3.91 19.3 11.4 7.8 85.6 0.856 193.3 84.1 4.1 14.42 7.39 23.0 35.0 30.9 3.90 19.4 11.5 7.9 90.0 0.900 195.0 84.0 4.0 15.16 7.46 23.0 35.0 31.0 3.88 19.5 11.5 8.0 Values @ Failure 4.8 2.92 6.52 21.5 33.5 28.7 3.99 17.9 10.7 7.2 Failure criteria used* 3 `Note:"1"=Max Deviator Stress;"2"=Deviator Stress @ 15% Strain;"3"=Max Eff.Stress Ratio(a',/a'3) Page 3 of 7 Triaxial CU.xls [CJ, REV 1; 10-10-05 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com dcAii A SHIEI 2•e c a r o I r c o Tested By Date Check EB/KP 01/12/21 ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Project # Project Name Sample ID Location 20-623 American Thread 36975/B-11 Laboratory Project # Sample Type Depth/Elevation Additional Info 2160-03-1 Remold 10-15' Shear Stress, psi 40 30 20 10 0 Total and Effective Mohr's Circles y = 0.5825x + 1.997 C y = 0.2585x + 5.3229 0 Specimen Effective Consolidation Stress, psi Deviator Stress at Failure, psi Effective Minor Principal Stress at Failure, psi Effective Major Principal Stress at Failure, psi Axial Strain at Failure, % i 10 20 Normal Stress, psi A B 3.0 6.0 12.0 15.7 18.0 21.5 4.4 5.1 7.2 20.1 23.2 28.7 1.71 2.06 2.92 30 40 STRENGTH PARAMETERS* Total Effective (I)° 14.5 (I)'° 30.2 C, psi 5.3 C', psi 2.0 *Valid only for Received Material at Reported Densities and Moisture Contents. Please see remarks on page 6 of this report Triaxial CUxls [Mohr's Circles], REV. 1; 10-10-05 Page 4 of 7 TcT TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com AASHI0 R C C R E a ITC 0 Tested By EB/KP ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # Pr. Name American Thread Sample Type Sample ID 36975/B-11 Depth/Elevation Location - Additional Info Date 01/12/21 Check 41459 2160-03-1 Remold 10-15' P' - Q Graph 0 2 4 -0 50( R2- 2x i 1.7172-- 0.9933 1 10 12 P', psi 14 16 18 20 22 22 20 18 16 14 8 6 4 2 0 FAILURE SKETCH A B REMOLDING PROPERTIES A B % Compaction of Max Dry Density % Difference from Optimum M.C. 95.0 95.1 C 95.1 3.2 Page 5 of 7 3.2 3.2 a, psi a, degree 1.7 26.8 Triaxial CUxls [P'-Q GRAPHJ, REV. 1; 10-10-05 TIMELY ENGINEERING SoIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com A A S H I O ADMRICOJTED Tested By EB/KP Date 01/12/21 Check Client Pr. # Pr. Name Sample ID Location ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Laboratory Project # Sample Type Depth/Elevation Additional Info 20-623 American Thread 36975/B-11 2160-03-1 Remold 10-15' Deviator Stress, Au, psi 24 20 16 12 Stress - Strain Graph ♦ • 8 i 0 r" 0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Axial Strain, Balance ID Number Oven ID Number Deformation Indicator ID # Digital Caliper ID # Load Cell ID # Apparatus ID # REMARKS DESCRIPTION 563/700 496/610 178/349/689 370/458 347/692/815 293/693/814 Samples (Material passing #4 Sieve) were remolded to specified % compaction and moisture content of Standard Proctor values Dark Brown Sandy Silt NOTES: 1. Method for Saturation 2. Method for determination of cross -sectional after consolidation 3. Initial specimen moisture content obtained from cuttings 4. Final specimen moisture content obtained from entire sample WET B LL PL PI Gs USCS (ASTM D2487: D2488) ML Triaxial CU.xls [Stress -Strain GRAPH], REV. 1; 10-10-05 Pagr 6 of 7 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Tested By EB/KP Date Check 01/12/21 �— ..A. A. SH ID Web: www.test-llc.com r ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # 2160-03-1 Pr. Name American Thread Sample Type Remold Sample ID 36975/B-11 Depth/Elevation 10-15' Location - Additional Info - Pore Pressure - Strain Graph Pore Pressure, psi N O N A c _C I I � A i E i 0 2 3 4 5 6 7 8 9 10 11 12 13 14 Axial Strain, % 15 16 5.00 Effective Stress Ratio -Strain Graph A — 1- B t U-U 4.00 r— S- 0 ii--• ♦ ♦ ♦ ♦ r w co 3.00 N N o 2.00 al LEJ 1.00n 0.00 0 2 4 6 8 10 12 14 16 Axial Strain,% Triaxial CU.xls [Stress Ratio & Pore Water Pr. -Strain GRAPH], REV. 1; 10-10-05 Page 7 of 7 TIMELY ENGINEERING SoIL. TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com AASHI❑ hG G RCG IT CO Tested By TH Date 01/09/21 Checked By Client Pr. # Pr. Name Sample ID Location 20-623 American Thread 36975/B-11 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 Bulk 10-15' ASTM D 4318/AASHTO T 88, T 89 Standard Test Method for Liquid Limit, Plastic Limit, and Plasticity Index of Soils (Atterberg Limits) Number of Blows Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % MOISTURE CONTENT °/ 37 36 35 34 33 32 31 LIQUID LIMIT 32 22 15 36.82 38.51 38.29 34.55 34.12 34.72 27.61 21.26 24.68 32.71 34.14 35.56 Oven ID # Balance ID # Liquid Limit Device ID # 10 Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % DESCRIPTION 20 25 30 40 NUMBER OF BLOWS PLASTIC LIMIT 37.12 39.20 34.66 36.30 25.18 25.04 25.95 25.75 NATURAL MOISTURE 653.40 554.20 302.80 39.46 Dark Brown Sandy Silt 15/496/610 139/563 451/569 100 NOTE: MATERIAL PASSING NO. 40 SIEVE WAS USED FOR TEST LIQUID LIMIT (LL) PLASTIC LIMIT (PL) PLASTICITY INDEX (PI) LIQUIDITY INDEX (LI) USCS (ASTM D2487; D2488) ML AASHTO (M 145) 34 26 8 1.68 NA TIMELY ENGINEERINGPhone: SOIL TEST'S, LLC 1874 Forge Street Tucker, GA 770-938-8233 Fax: 770-923-8973 Web: www.test-11c.com 30084 Tested By Date Checked By n T.E. A S.T. IH 01/07/21 A A G G R C O T co Ale Client Pr. # Pr. Name Sample ID Location 20-623 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 American Thread Bulk 36975/B-11 10-15' - - ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311; Particle Size Analysis (Split Sieve) MOISTURE CONTENT of TOTAL Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % SAMPLE MOISTURE CONTENT of FINE MATERIAL Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % 653.4 426.40 554.2 405.40 302.8 85.30 39.5 6.6 TOTAL Mass of wet sample before splitting & tare, g Mass of Tare, g TOTAL Mass of dry sample, g Mass of Wet Fine Material & Tare, g Mass of Tare, g Mass of Dry Fine Material, g % of Total Sample Passing Split Sieve 22700.0 185.00 0.0 0.00 16277.2 173.61 100.0 SIEVE ANALYSIS* Mass of Tare, Sieve Size 12" 3" 2.5" 2" 1.5" 1" .75" 5" .375" COARSE g MATERIAL % RETAINED % PASSING Mass of Tare, g Sieve Size #4 #10 #20 #40 #60 #100 #200 * - ASTM Defini ** - AASHTO Definitions FINE MATERIAL % PASSING (of Total) 0.0 0.00 Sample & Tare, g Cumulative Mass retained, g COBBLES 0.0 100.0 COARSE GRAVEL 0.0 100.0 COARSE SAND 1.10 99.4 0.0 100.0 MEDIUM SAND 6.95 96.0 0.0 100.0 14.66 91.6 0.0 100.0 FINE SAND 22.51 87.0 0.0 100.0 30.15 82.6 FINE GRAVEL 0.0 100.0 42.20 75.7 0.0 100.0 FINES 68.20 60.7 0.0 0.0 100.0 ions of Classification of Classification NOTE: Sieve 3/8" (9.5 mm) Sieve used for splitting sample on fine and coarse material PARTICLE -SIZE ANALYSIS' Oven ID # Balance ID# Shaker ID # REMARKS 15/496/610 % COBBLES % COARSE Gravel % FINE Gravel % COARSE Sand 0.0 % MEDIUM Sand % FINE Sand % FINES % TOTAL SAMPLE 9.0 139/142/700 0.0 26.3 555 0.6 60.7 3.4 100.0 PARTICLE -SIZE ANALYSIS"" COBBLES % COARSE Gravel (Stone) % MEDIUM Gravel (Stone) % FINE Gravel (Stone) 0.0 % COARSE Sand % FINE Sand % FINES (Silt -Clay) % TOTAL SAMPLE 9.0 0.0 26.3 0.0 60.7 4.0 100.0 DESCRIPTION USCS (ASTM D2487; Dark Brown Sandy Silt D2488) AASHTO (M 145) Page 1 of 2 ML NA TIMELY 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 '1".. S.T. ENGINEERING Tested By IH SOIL Date 01/07/21 Web: WWW.test-Ilc.com .4 SH CI G Checked By Ale TESTS, LLC Client Pr. # Pr. Name Sample ID Location 20-623 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 American Thread Bulk 10-15' 36975/B-11 - - ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311 Standard Test Method for Particle -Size Analysis of Soils and Aggregates (Split Sieve) Particle -Size Analysis _ VV o m o 0 V 0V 0 0 0 0 0 , M N ,, .-. N ik K ik ik 5 5 5 E a 8 8 100 90 •• • • • ♦ • . •• • • • •• • • • 80 70 P 60 A S 50 S I N 40 G 30 20 10 0 1000 100 10 1 0 1 0.01 0.001 Grain size in millimeters Coarse Fine Coarse Medium Fine Silt or Clay Boulders Cobbles Gravel Sand Fines Dto NA mm D30 NA mm D60 NA mm Cu NA Cc NA Project's Specific % Passing NA Page 2 of 2 Project's Specific Particle Size, mm NA TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com AA5H1❑ A99 RCQI TC6 Tested By Date IH 01/09/21 Checked By seer Client Pr. # Pr. Name Sample ID Location 20-623 American Thread 36975/B-11 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 Bulk 10-15' ASTM D 698 Standard Test Method for Laboratory Compaction Characteristics of Soil Using Standard Effort (12,400 ft-Ibf/ft3 (600kN-m/m3)) Mass of Soil before sieving, g Mass of Mat. Retained on No. 4 sieve, g Mass of Mat. Retained on 3/8" sieve, g Mass of Mat. Retained on 3/4" sieve, g Material Retained on No. 4 Sieve, Material Retained on 3/8" Sieve, % Material Retained on 3/4" Sieve, % Total, % (oversized) Points Mass of Mold and Soil, g Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, Wet Density, pcf Dry Density, pcf DETERMINATION OF TEST PROCEDURE wet dry 22700.0 16277.2 0.0 TEST DATA MOISTURE CONTENT Coarse + Fine Coarse Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, 1 2 3 4 5 5940.5 5984.5 6008.0 6024.5 506.0 506.0 525.9 524.4 449.7 444.8 467.2 461.4 130.7 130.0 184.0 176.1 17.6 19.4 20.7 22.1 Procedure B Mold ID Number Mass of Mold, g Volume of Mold, ft3 Hammer ID Number Number of Blows per layer Number of Layers Mechanical Compactor ID Number 798 4252.4 0.0333 318 25 3 317 111.8 114.7 116.2 117.3 95.0 96.0 96.3 96.1 Method A: Material retained on No. 4 Sieve<25% Method B: Material retained on 3/8" Sieve <25% Method C: Material retained on 3/4" Sieve <30% Dry Density, pcf 103.0 101.0 99.0 97.0 • . 95.0 93.0 17.0 Moisture vs. Dry Density 4 100% Saturation Curves: Gs=2.6); (Gs=2.7 ; (Gs=2.8) 18.0 19.0 20.0 21.0 22.0 23.0 24.0 Moisture Content, % 25.0 26.0 27.0 REMARKS DESCRIPTION Dark Brown Sandy Silt Maximum Dry Density, pcf Optimum Moisture Content, % 96.3 21.0 USCS (ASTM D2487; D2488) Corrected Maximum Dry Density, pcf Corrected Optimum Moisture Content, % ML AASHTO M145 NA NA NA TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233Al% Fax: 770-923-8973 rlig it t. Tested By EB/KP Date 01/07/21 'n"cb` 8 I -I a Web: www.test-Ilc.com T Checked By ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # 20-623 Laboratory Project # 2160-03-1 Project Name American Thread Sample Type UD Sample ID 36976/B-11 Depth/Elev. 15-17.5' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION (initial) (final) Height, in 5.718 5.698 Mass of Wet Sample and Tare, g 801.10 1143.20 Diameter, in 2.862 2.819 Mass of Dry Sample and Tare, g 697.20 890.09 Height -to -Diameter Ratio 2.0 2.0 Mass of Tare, g 358.70 0.00 Area, in2 6.43 6.24 Moisture, % 30.69 28.44 Volume, cm3 602.80 582.77 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 1163.30 1143.20 Volume change (Consolidation), ml -20.1 Mass of Dry Sample, g 890.09 890.09 Machine Speed, in / min 0.0050 Wet Density, pcf 120.5 122.5 Strain Rate, % / min 0.09 Dry Density, pcf 92.2 95.3 Chamber Pressure, psi 87.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure, psi 80.0 Volume of Solids, cm3 329.66 329.66 Eff. Consol. Stress,(Minor pr. stress, (53),psi 7.0 Volume of Voids, cm3 273.14 253.11 Change in Height, in 0.020 Void Ratio 0.83 0.77 "B" Value 0.95 % Saturation 100.0 100.0 SHEAR DATA Elapsed Time (min) Deformation Stage 1 (inch) Axial Load (lb) Pore -Water Pressure, psi P Total Strain Stage 1 (%) Corrected p Area (in) Dev.Stress 4a a ( 3) Major Principal Stress,psi Eff.Stress Ratio p' (61+a 3)/2 (psi) Q (ara3)/2 (psi) Eff. Minor Pr. Stress Total, U Change,4U (psi) Total al Eff. a'1 a',/ '3 63 (psi) 0.0 0.000 21.9 80.00 0.0 0.00 6.24 0.0 7.0 7.0 1.00 7.0 0.0 7.0 1.0 0.005 38.1 81.19 1.2 0.09 6.25 2.6 9.6 8.4 1.45 7.1 1.3 5.8 2.0 0.010 48.4 81.90 1.9 0.18 6.25 4.2 11.2 9.3 1.83 7.2 2.1 5.1 3.0 0.015 55.9 82.54 2.5 0.26 6.26 5.4 12.4 9.9 2.22 7.2 2.7 4.5 4.0 0.020 60.3 82.82 2.8 0.35 6.26 6.1 13.1 10.3 2.47 7.2 3.1 4.2 5.0 0.025 65.0 83.04 3.0 0.44 6.27 6.9 13.9 10.8 2.74 7.4 3.4 4.0 6.0 0.030 69.8 83.21 3.2 0.53 6.27 7.6 14.6 11.4 3.01 7.6 3.8 3.8 7.0 0.035 75.5 83.30 3.3 0.61 6.28 8.5 15.5 12.2 3.31 8.0 4.3 3.7 8.0 0.040 78.3 83.37 3.4 0.70 6.29 9.0 16.0 12.6 3.47 8.1 4.5 3.6 10.0 0.050 85.8 83.41 3.4 0.88 6.30 10.1 17.1 13.7 3.83 8.7 5.1 3.6 12.0 0.060 93.0 83.41 3.4 1.05 6.31 11.3 18.3 14.9 4.14 9.2 5.6 3.6 14.0 0.070 99.4 83.39 3.4 1.23 6.32 12.3 19.3 15.9 4.40 9.7 6.1 3.6 16.0 0.080 105.8 83.31 3.3 1.40 6.33 13.3 20.3 16.9 4.59 10.3 6.6 3.7 18.0 0.090 111.7 83.21 3.2 1.58 6.34 14.2 21.2 18.0 4.74 10.9 7.1 3.8 20.0 0.100 117.2 83.10 3.1 1.76 6.35 15.0 22.0 18.9 4.85 11.4 7.5 3.9 22.0 0.110 122.1 82.98 3.0 1.93 6.36 15.7 22.7 19.8 4.92 11.9 7.9 4.0 24.0 0.120 127.3 82.86 2.9 2.11 6.38 16.5 23.5 20.7 4.99 12.4 8.3 4.1 26.0 0.130 131.8 82.74 2.7 2.28 6.39 17.2 24.2 21.5 5.04 12.9 8.6 4.3 28.0 0.140 136.6 82.60 2.6 2.46 6.40 17.9 24.9 22.3 5.07 13.4 9.0 4.4 30.0 0.150 140.8 82.46 2.5 2.63 6.41 18.5 25.5 23.1 5.09 13.8 9.3 4.5 32.0 0.160 144.6 82.32 2.3 2.81 6.42 19.1 26.1 23.8 5.08 14.2 9.6 4.7 33.0 0.165 146.4 82.24 2.2 2.90 6.43 19.4 26.4 24.1 5.07 14.4 9.7 4.8 Values @ Failure 2.5 2.63 6.41 18.5 25.5 23.1 5.09 13.8 9.3 4.5 Failure criteria used* 3 *Note: "1" = Max Deviator Stress; "2" = Deviator Stress @ 15% Strain; "3" = Max Eff.Stress Ratio(d1/d3) Page 1 of 7 TIMELY ENGINEERING .SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 liL Fax:770-923-8973 Li Tested By EB/KP Date 01/09/21 Checked By Alv A s H Cll Web: www.test-Ilc.com T ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # 20-623 Laboratory Project # 2160-03-1 Project Name American Thread Sample Type UD Sample ID 36976/B-11 Depth/Elev. 15-17.5' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION (initial) (final) Height, in 5.533 5.578 Mass of Wet Sample and Tare, g 1143.20 1137.80 Diameter, in 2.861 2.836 Mass of Dry Sample and Tare, g 890.09 890.09 Height -to -Diameter Ratio 1.9 2.0 Mass of Tare, g 0.00 0.00 Area, in2 6.43 6.32 Moisture, % 28.44 27.83 Volume, cm3 582.77 577.37 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 1143.20 1137.80 Volume change (Consolidation), ml -5.4 Mass of Dry Sample, g 890.09 890.09 Machine Speed, in / min 0.0050 Wet Density, pcf 122.5 123.0 Strain Rate, % / min 0.09 Dry Density, pcf 95.3 96.2 Chamber Pressure, psi 94.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure, psi 80.0 Volume of Solids, cm3 329.66 329.66 Eff. Consol. Stress,(Minor pr. stress, a3),psi 14.0 Volume of Voids, cm3 253.11 247.71 Change in Height, in -0.045 Void Ratio 0.77 0.75 "B" Value 0.95 % Saturation 100.0 100.0 SHEAR DATA Deformation Stage 2 (inch) Total Deformation ST.1 + ST.2 (inch) Axial Load (lb) Pore -Water Pressure, psi P Strain Stage 2 / Corrected 2 Area (in) Dev.Stress 06 6 ( s) (psi)Total Major Principal Stress,psi Effective Stress Ratio rs' /al 3 P' (a i+a 3)/2 (psi) Q (ai o3)/2 (psi) Eff. Minor Pr. Stress a3 (psi) ' Total Strain ST.1 + ST.2 Total, U Chan e,DU 9 a Eff' . a 0.000 0.120 23.4 80.00 0.0 0.00 6.32 0.0 14.0 14.0 1.00 14.0 0.0 14.0 2.11 0.005 0.125 61.5 82.38 2.4 0.09 6.32 6.0 20.0 17.6 1.52 14.6 3.0 11.6 2.19 0.010 0.130 80.0 83.71 3.7 0.18 6.33 8.9 22.9 19.2 1.87 14.8 4.5 10.3 2.28 0.015 0.135 93.9 84.50 4.5 0.27 6.33 11.1 25.1 20.6 2.17 15.1 5.6 9.5 2.37 0.020 0.140 103.9 84.88 4.9 0.36 6.34 12.7 26.7 21.8 2.39 15.5 6.3 9.1 2.46 0.025 0.145 112.8 85.16 5.2 0.45 6.34 14.1 28.1 22.9 2.59 15.9 7.0 8.8 2.54 0.030 0.150 121.0 85.32 5.3 0.54 6.35 15.4 29.4 24.0 2.77 16.4 7.7 8.7 2.63 0.035 0.155 128.6 85.44 5.4 0.63 6.36 16.6 30.6 25.1 2.93 16.8 8.3 8.6 2.72 0.040 0.160 135.9 85.52 5.5 0.72 6.36 17.7 31.7 26.2 3.09 17.3 8.8 8.5 2.81 0.050 0.170 148.7 85.63 5.6 0.90 6.37 19.7 33.7 28.0 3.35 18.2 9.8 8.4 2.98 0.060 0.180 160.3 85.69 5.7 1.08 6.39 21.4 35.4 29.8 3.58 19.0 10.7 8.3 3.16 0.070 0.190 169.5 85.70 5.7 1.25 6.40 22.8 36.8 31.1 3.75 19.7 11.4 8.3 3.33 0.080 0.200 177.7 85.71 5.7 1.43 6.41 24.1 38.1 32.4 3.90 20.3 12.0 8.3 3.51 0.090 0.210 184.2 85.67 5.7 1.61 6.42 25.0 39.0 33.4 4.01 20.9 12.5 8.3 3.69 0.100 0.220 190.0 85.60 5.6 1.79 6.43 25.9 39.9 34.3 4.08 21.4 13.0 8.4 3.86 0.110 0.230 195.2 85.52 5.5 1.97 6.44 26.7 40.7 35.1 4.14 21.8 13.3 8.5 4.04 0.120 0.240 200.0 85.42 5.4 2.15 6.46 27.4 41.4 35.9 4.19 22.3 13.7 8.6 4.21 0.130 0.250 204.2 85.30 5.3 2.33 6.47 28.0 42.0 36.7 4.21 22.7 14.0 8.7 4.39 0.140 0.260 208.4 85.18 5.2 2.51 6.48 28.6 42.6 37.4 4.24 23.1 14.3 8.8 4.56 0.145 0.265 210.4 85.10 5.1 2.60 6.49 28.8 42.8 37.7 4.24 23.3 14.4 8.9 4.65 0.150 0.270 212.0 85.04 5.0 2.69 6.49 29.1 43.1 38.0 4.24 23.5 14.5 9.0 4.74 0.155 0.275 213.8 84.98 5.0 2.78 6.50 29.3 43.3 38.3 4.25 23.7 14.7 9.0 4.83 Values @ Failure 5.0 2.78 6.50 29.3 43.3 38.3 4.25 23.7 14.7 9.0 4.83 Failure criteria used* 3 'Note: "1" = Max Deviator Stress; "2" = Deviator Stress @ 15% Strain; "3" = Max Eff.Stress Ratio(dl/d3) ayc c VI 0 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 sltik Fax:770-923-8973 'l; Tested By FB/KP Date 01/10/21 Checked By Age ,... 5 H O Web: www.test-Ilacom T ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # 20-623 Laboratory Project # 2160-03-1 Project Name American Thread Sample Type UD Sample ID 36976/B-11 Depth/Elev. 15-17.5' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION (initial) (final) Height, in 5.423 5.482 Mass of Wet Sample and Tare, g 1137.80 1431.10 Diameter, in 2.876 2.854 Mass of Dry Sample and Tare, g 890.09 1183.90 Height -to -Diameter Ratio 1.9 1.9 Mass of Tare, g 0.00 299.80 Area, in2 6.50 6.40 Moisture, % 27.83 27.96 Volume, cm3 577.37 574.70 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 1137.80 1131.40 Volume change (Consolidation), ml -6.4 Mass of Dry Sample, g 890.09 884.18 Machine Speed, in / min 0.00500 Wet Density, pcf 123.0 122.9 Strain Rate, % / min 0.09 Dry Density, pcf 96.2 96.0 Chamber Pressure, psi 108.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure, psi 80.0 Volume of Solids, cm3 329.66 327.47 Eff. Consol. Stress,(Minor pr. stress, a3),psi 28.0 Volume of Voids, cm3 247.71 247.22 Change in Height, in -0.059 Void Ratio 0.75 0.75 "B" Value 0.95 % Saturation 100.0 100.0 SHEAR DATA Deformation Stage 3 (inch) Total Deformation ST.1 + ST.2 + ST.3 (inch) Axial Load (lb) Pore -Water Pressure, psi Strain Stage 3 Corrected Area (in2) Deviator Stress (Aa-aa3) r (psi) Major Principal Stress, psi Effective Stress Ratio a',/6'3 P' (6 +a'3)/2 (psi) Q (ai a3)/2 (psi) Eff. Minor Pr. Stress% 63 (psi) Total Strain ST.1 + ST.2 + ST.3, Total, U Change,DU Total al Eff. di 0.000 0.216 27.8 80.00 0.0 0.00 6.40 0.0 28.0 28.0 1.00 28.0 0.0 28.0 3.79 0.005 0.221 92.4 83.90 3.9 0.09 6.40 10.1 38.1 34.2 1.42 29.1 5.0 24.1 3.88 0.010 0.226 125.1 87.27 7.3 0.17 6.41 15.2 43.2 35.9 1.73 28.3 7.6 20.7 3.96 0.014 0.230 147.7 88.27 8.3 0.26 6.41 18.7 46.7 38.4 1.95 29.1 9.3 19.7 4.04 0.019 0.235 164.0 89.88 9.9 0.35 6.42 21.2 49.2 39.3 2.17 28.7 10.6 18.1 4.12 0.024 0.240 178.3 90.56 10.6 0.44 6.43 23.4 51.4 40.9 2.34 29.2 11.7 17.4 4.21 0.034 0.250 202.1 91.09 11.1 0.62 6.44 27.1 55.1 44.0 2.60 30.4 13.5 16.9 4.39 0.049 0.265 230.6 91.50 11.5 0.89 6.45 31.4 59.4 47.9 2.90 32.2 15.7 16.5 4.65 0.069 0.285 256.3 93.01 13.0 1.25 6.48 35.3 63.3 50.3 3.35 32.6 17.6 15.0 4.99 0.099 0.315 282.7 93.36 13.4 1.80 6.51 39.1 67.1 53.8 3.67 34.2 19.6 14.6 5.52 0.119 0.335 294.5 93.41 13.4 2.16 6.54 40.8 68.8 55.4 3.80 35.0 20.4 14.6 5.87 0.148 0.364 308.0 93.30 13.3 2.70 6.58 42.6 70.6 57.3 3.90 36.0 21.3 14.7 6.39 0.178 0.394 319.9 93.04 13.0 3.25 6.61 44.2 72.2 59.1 3.95 37.0 22.1 15.0 6.91 0.208 0.424 330.1 92.76 12.8 3.79 6.65 45.5 73.5 60.7 3.98 38.0 22.7 15.2 7.43 0.228 0.444 336.3 92.52 12.5 4.15 6.67 46.2 74.2 61.7 3.99 38.6 23.1 15.5 7.79 0.258 0.474 345.6 92.20 12.2 4.70 6.71 47.3 75.3 63.1 4.00 39.5 23.7 15.8 8.32 0.308 0.524 359.4 91.60 11.6 5.63 6.78 48.9 76.9 65.3 3.98 40.9 24.5 16.4 9.20 0.358 0.574 371.6 91.11 11.1 6.53 6.84 50.2 78.2 67.1 3.97 42.0 25.1 16.9 10.07 0.418 0.634 385.5 90.43 10.4 7.62 6.92 51.7 79.7 69.2 3.94 43.4 25.8 17.6 11.12 0.468 0.684 396.7 89.93 9.9 8.53 6.99 52.7 80.7 70.8 3.92 44.4 26.4 18.1 12.00 0.558 0.774 412.4 88.93 8.9 10.17 7.12 54.0 82.0 73.1 3.83 46.1 27.0 19.1 13.58 0.617 0.833 422.2 88.47 8.5 11.26 7.21 54.7 82.7 74.2 3.80 46.9 27.4 19.5 14.62 0.642 0.858 425.5 88.26 8.3 11.71 7.25 54.9 82.9 74.6 3.78 47.2 27.4 19.7 15.05 Values @ Failure 12.2 4.70 6.71 47.3 75.3 63.1 4.00 39.5 23.7 15.8 8.32 Failure criteria used` 3 'Note: "1" = Max Deviator Stress; "2" = Deviator Stress @ 15% Strain; "3" = Max Eff.Stress Ratio(a'1/a'3) Page 3of7 TIMELY ENGINEERING SoIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com AASHIO A C C A C I} ITC 6 Tested By EB/KP Date 01/10/21 Check ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # Project Name Sample ID Location 20-623 American Thread 36976/B-11 Laboratory Project # 2160-03-1 Sample Type UD Depth/Elev. 15-17.5' Additional Info E E Shear Stress, psi 80 70 60 50 40 30 20 10 0 Total and Effective Mohr's Circles Y= 0.681 R2 = x+1.7 1.000 0 10 20 30 40 50 Normal Stress, psi 60 Effective Consolidation Stress, psi Deviator Stress at Failure, psi ffective Minor Principal Stress at Failure, psi ffective Major Principal Stress at Failure, psi Axial Strain at Failure, % ST. 1 ST. 2 ST. 3 7.0 14.0 28.0 18.5 29.3 47.3 4.5 9.0 15.8 23.1 38.3 63.1 2.63 2.78 4.70 0.453x + 2. '5 R2 = 0.998 70 80 STRENGTH PARAMETERS* Total Effective ° 24.4 ' ° 34.2 C, psi 2.7 C', psi 1.8 *Valid only for Received Material at Reported Densities and Moisture Contents. Please see remarks on page 6 of this report Page 4 of 7 Jam. TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com !\ A 5 l- fi n Tech EB/KP Date 01/10/21 Check ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # Project Name Sample ID Location 20-623 American Thread 36976/B-11 Laboratory Project # Sample Type Depth/Elev. Additional Info 2160-03-1 UD 15-17.5' .t 0 50 40 30 20 10 P'- Q GRAPH pippin! 111 dm pm% 10 20 P', psi 30 40 50 FAILURE SKETCH Ss a, psi a, degree 1.4 29.3 Page 5 of 7 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com cslk AASHIO Tested By EB/KP Date 01/10/21 Check Ffr ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # Project Name Sample ID Location 20-623 American Thread 36976/B-11 Laboratory Project # Sample Type Depth/Elev. Additional Info 2160-03-1 UD 15-17.5' Deviator Stress, AG, psi 60 50 40 30 20 10 Deviator Stress - Strain Graph 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Balance ID Number Oven ID Number Deformation Indicator ID # Digital Caliper ID # Load Cell ID # Apparatus ID # Total Axial Strain, REMARKS 563/700 Material from shelby tube was not homogeneous and/or not 496/610 long enough to select 3 uniform specimens 6" long each. 178/349/689 Most representative portion of sample (5" above the bottom 370/458 of shelby tube) was selected for multi -stage triaxial testing 11/347/692 (per ASTM STP 883). 10/293/693 NOTES: 1. Method for Saturation 2. Method for determination of cross -sectional area after consol. 3. Final moisture content (Stage 3) obtained from entire sample DESCRIPTION Brown Sandy Silt WET B LL PL PI Gs USCS (ASTM D2487: D2488) ML Page 6 of 7 ki TIMELY ENGINEERING SoIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com A.ASHIO n.. w s o I Y! 6 Tested By EB/KP Date 01/10/21 Check doter ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # Project Name Sample ID Location 20-623 American Thread 36976/B-11 Laboratory Project # Sample Type Depth/Elev. Additional Info 2160-03-1 UD 15-17.5' L 0 a 14 12 10 4 2 0 Pore Pressure - Strain Graph MI Mil MI MI II NI I II IN FM MEM 0 111111111111111111111 111111111111111111111 111111111111111111111 2 3 4 5 6 7 8 9 10 Total Axial Strain, % 11 12 13 14 15 16 Effective Stress Ratio -Strain Graph 00 6.00 5.50 5.00 c 4.50 Y ix 4.00 • • • y 3.50 a) 3.00 2.50 W 2.00 1.50 1.00 0.00 2.00 4.00 6.00 Total 8.00 Axial Strain, % 10 00 12 00 14 00 16 Page 7 of 7 riE; TIMELY ENGINEERING SoIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-IIc.com AASH Tested By EB Date 01/07/21 Checked By Fie Client Pr. # Pr. Name Sample ID Location 20-623 American Thread 36976/B-11 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 UD 15-17.5' ASTM D 4318/AASHTO T 88, T 89 Standard Test Method for Liquid Limit, Plastic Limit, and Plasticity Index of Soils (Atterberg Limits) Number of Blows Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % MOISTURE CONTENT 31 30 29 28 27 26 25 LIQUID LIMIT 35 27 15 46.08 41.31 42.53 42.00 37.32 38.43 26.77 23.02 24.75 26.79 27.90 29.97 Oven ID # Balance ID # Liquid Limit Device ID # 10 Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % DESCRIPTION 20 25 30 40 NUMBER OF BLOWS PLASTIC LIMIT 35.26 38.07 33.20 35.65 24.38 25.34 23.36 23.47 NATURAL MOISTURE 801.10 697.20 358.70 30.69 Brown Sandy Silt 100 15/496/610 139/563 451/569 NOTE: MATERIAL PASSING NO. 40 SIEVE WAS USED FOR TEST LIQUID LIMIT (LL) PLASTIC LIMIT (PL) PLASTICITY INDEX (PI) LIQUIDITY INDEX (LI) USCS (ASTM D2487; D2488) ML AASHTO (M 145) 28 23 5 1.54 NA TIMELY ENGINEERING SOIL TESTS, LLC 11874 Forge Street Tucker, GA Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com 30084 Tested By Date Checked By T,I, ,� IH 111, 01/07/21 A A S Hr n ale Client Pr. # Pr. Name Sample ID Location 20-623 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 American Thread UD 36976/B-11 15-17.5' - - ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311; Particle Size Analysis (Split Sieve) MOISTURE CONTENT of TOTAL Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % SAMPLE MOISTURE CONTENT of FINE MATERIAL Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % 801.1 302.80 697.2 294.90 358.7 99.50 30.7 4.0 TOTAL Mass of wet sample before splitting & tare, g Mass of Tare, g TOTAL Mass of dry sample, g Mass of Wet Fine Material & Tare, g Mass of Tare, g Mass of Dry Fine Material, g % of Total Sample Passing Split Sieve 818.0 150.60 0.0 0.00 625.9 144.75 96.3 SIEVE ANALYSIS* Mass of Tare, Sieve Size 12" 3" 2.5" 2" 1.5" 1" 75" .5" .375" #4 COARSE g MATERIAL % RETAINED % PASSING Mass of Tare, g Sieve Size #10 #20 #40 #60 #1oo #20o * - ASTM Defini ** - AASHTO Definitions FINE MATERIAL % PASSING (of Total) 0.0 0.00 Sample & Tare, g Cumulative Mass retained, g COBBLES 0.0 100.0 COARSE GRAVEL 0.0 100.0 0.0 100.0 MEDIUM SAND 1.57 95.3 0.0 100.0 3.18 94.2 0.0 100.0 FINE SAND 5.62 92.6 0.0 100.0 9.72 89.9 FINE GRAVEL 0.0 0.0 100.0 22.38 81.4 14.6 2.3 97.7 FINES 62.11 55.0 18.1 2.9 97.1 ions of Classification of Classification COARSE SAND 22.9 3.7 96.3 NOTE: Sieve # 4 (4.75 mm) Sieve used for splitting sample on fine and coarse material PARTICLE -SIZE ANALYSIS* Oven ID # Balance ID# Shaker ID # REMARKS 15/496/610 % COBBLES % COARSE Gravel % FINE Gravel % COARSE Sand 0.0 % MEDIUM Sand % FINE Sand % FINES % TOTAL SAMPLE 2.7 139/142/700 0.0 37.6 555 3.7 55.0 1.0 100.0 PARTICLE -SIZE ANALYSIS** % COBBLES % COARSE Gravel (Stone) % MEDIUM Gravel (Stone) % FINE Gravel (Stone) 0.0 % COARSE Sand % FINE Sand % FINES (Silt -Clay) % TOTAL SAMPLE 2.7 0.0 37.6 2.9 55.0 1.8 100.0 DESCRIPTION USCS (ASTM D2487; Brown Sandy Silt D2488) AASHTO (M 145) Page 1 of 2 ML NA TIMELY 1874 Forge Street Tucker, GA 30084 f . T.E. Tested By IH IF L. ENGINEERING SOIL Phone: 770-938-8233 A Fax: 770-923-8973 Date 01/07/21 AA H M Checked By TESTS, LLC Web: www.test-Ilc.com - - Client Pr. # Pr. Name Sample ID Location 20-623 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 American Thread UD 36976/B-11 15-17.5' - - ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311 Standard Test Method for Particle -Size Analysis of Soils and Aggregates (Split Sieve) Particle -Size Analysis _ VV o m 0, 0 0 o m o 0 .�. �p M N N .-. ^' N x ik ik 3k ik 100 - ♦♦♦ . " - 90 80 70 P 60 A S S 50 I N 40 G 30 20 10 0 1000 100 10 0 1 0.01 0.001 Grain size in millimeters Coarse Fine Coarse I Medium Fine Silt or Clay Boulders Cobbles Gravel Sand Fines Dia NA mm Dso NA mm D60 NA mm Cu NA Cc NA Project's Specific % Passing NA Page 2 of 2 Project's Specific Particle Size, mm NA TIMELY 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Tested By Date Checked ByAle i - < ENGINEERING SOIL TESTS, LLC IH 01/06/21 Web: www.test-Ilc.com ; '�` S H� o Client Pr. # 20-623 Lab. PR. # 2160-03-1 Pr. Name American Thread S. Type UD Sample ID 36976/B-11 Depth/Elev. 15-17.5' Location - Add. Info - ASTM D 2166; Standard Test Method for Unconfined Compressive Strength of Soils SAMPLE DATA STRESS -STRAIN GRAPH Initial Height, in 5.722 ,,,,, Stress, psi A o o O O Initial Diameter, in 2.852 Height -to -Diameter Ratio 2.01 Initial Area, in2 6.39 Initial Volume, ini 36.55 Mass of Sample, g 1158.30 Wet Density, 120.71 pcf Dry Density, pcf 92.32 10 20 30 40 50 60 70 Machine Speed, in/min 0.025 Stra n, % Strain Rate, % / min 0.44 WATER CONTENT DETERMINATION Note: Water content was obtained after shear from partial sample. Mass of Wet Sample and Tare, g 801.10 TEST DATA Mass of Dry Sample and Tare, g 697.20 Mass of Tare, g 358.70 Load Cell ID # 11 Digital Caliper ID # 16 Moisture, % 30.7 Apparatus ID # 10 Deformation Indicator ID # 9/93 REMARKS Elapsed Time (min) Deformation (inch) Axial Load (lb) Total Strain (%) Corrected Area (in2) Compressive Stress (psi) Portion of sample used for above the bottom of the shelby UCS test was tube. located 12" 0.0 0.000 4 0.0 6.39 0.0 0.4 0.010 5 0.2 6.40 0.2 0.8 0.020 6 0.3 6.41 0.3 1.2 0.030 9 0.5 6.42 0.8 Failure Code 4 2.0 0.050 12 0.9 6.44 1.2 3.0 0.075 16 1.3 6.47 1.9 Failure Sketch 4.0 0.100 21 1.7 6.50 2.6 5.0 0.125 26 2.2 6.53 3.4 6.0 0.150 31 2.6 6.56 4.1 7.0 0.175 34 3.1 6.59 4.6 8.0 0.200 38 3.5 6.62 5.1 9.0 0.225 41 3.9 6.65 5.6 10.0 0.250 44 4.4 6.68 6.0 Failure Type: Shear 12.0 0.300 41 5.2 6.74 5.5 14.0 0.350 33 6.1 6.80 4.3 DESCRIPTION Brown Sandy Silt USCS (ASTM D2487: D2488) UNCONFINED COMPRESSIVE STRENGTH AT FAILURE, q, (psi) 6.0 ML UNCONFINED SHEAR STRENGTH AT FAILURE, s„ (psi) 3.0 Balance ID Number 1/7 STRAIN AT FAILURE, % 4.4 Oven ID Number 12/13/14 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233Al% Fax: 770-923-8973 rlig it t. Tested By EB/KP Date 01/07/21 'n"cb` 8 I -I a Web: www.test-Ilc.com T Checked By ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # 20-623 Laboratory Project # 2160-03-1 Project Name American Thread Sample Type UD Sample ID 36977/B-2 Depth/Elev. 8-10.5' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION (initial) (final) Height, in 5.702 5.682 Mass of Wet Sample and Tare, g 771.50 967.30 Diameter, in 2.860 2.766 Mass of Dry Sample and Tare, g 662.80 647.84 Height -to -Diameter Ratio 2.0 2.1 Mass of Tare, g 361.30 0.00 Area, in2 6.42 6.01 Moisture, % 36.05 49.31 Volume, cm3 600.28 559.40 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 881.40 967.30 Volume change (Consolidation), ml 85.9 Mass of Dry Sample, g 647.84 647.84 Machine Speed, in / min 0.0100 Wet Density, pcf 91.7 107.9 Strain Rate, % / min 0.18 Dry Density, pcf 67.4 72.3 Chamber Pressure, psi 84.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure, psi 80.0 Volume of Solids, cm3 239.94 239.94 Eff. Consol. Stress,(Minor pr. stress, (53),psi 4.0 Volume of Voids, cm3 360.34 319.46 Change in Height, in 0.020 Void Ratio 1.50 1.33 "B" Value 0.95 % Saturation 64.8 100.0 SHEAR DATA Elapsed Time (min) Deformation Stage 1 (inch) Axial Load (lb) Pore -Water Pressure, psi P Total Strain Stage 1 (%) Corrected p Area (in) Dev.Stress 4a a ( 3) Major Principal Stress,psi Eff.Stress Ratio p' (61+a 3)/2 (psi) Q (ara3)/2 (psi) Eff. Minor Pr. Stress Total, U Change,4U (psi) Total al Eff. a'1 d1/e'3 63 (psi) 0.0 0.000 19.4 80.00 0.0 0.00 6.01 0.0 4.0 4.0 1.00 4.0 0.0 4.0 0.5 0.005 38.3 80.55 0.5 0.09 6.01 3.1 7.1 6.6 1.91 5.0 1.6 3.5 1.0 0.010 49.4 80.70 0.7 0.18 6.02 5.0 9.0 8.3 2.51 5.8 2.5 3.3 1.5 0.015 58.0 80.75 0.8 0.26 6.02 6.4 10.4 9.7 2.97 6.5 3.2 3.3 2.0 0.020 66.0 80.78 0.8 0.35 6.03 7.7 11.7 10.9 3.40 7.1 3.9 3.2 2.5 0.025 73.3 80.76 0.8 0.44 6.03 8.9 12.9 12.2 3.76 7.7 4.5 3.2 3.0 0.030 80.9 80.73 0.7 0.53 6.04 10.2 14.2 13.5 4.11 8.4 5.1 3.3 3.5 0.035 88.3 80.69 0.7 0.62 6.05 11.4 15.4 14.7 4.44 9.0 5.7 3.3 4.0 0.040 95.4 80.64 0.6 0.70 6.05 12.6 16.6 15.9 4.74 9.6 6.3 3.4 5.0 0.050 109.3 80.55 0.5 0.88 6.06 14.8 18.8 18.3 5.30 10.9 7.4 3.5 6.0 0.060 123.5 80.34 0.3 1.06 6.07 17.1 21.1 20.8 5.68 12.2 8.6 3.7 7.0 0.070 135.8 80.24 0.2 1.23 6.08 19.1 23.1 22.9 6.09 13.3 9.6 3.8 8.0 0.080 147.3 80.05 0.0 1.41 6.09 21.0 25.0 24.9 6.31 14.4 10.5 4.0 9.0 0.090 160.2 79.77 -0.2 1.58 6.10 23.1 27.1 27.3 6.45 15.8 11.5 4.2 10.0 0.100 170.7 79.54 -0.5 1.76 6.12 24.7 28.7 29.2 6.55 16.8 12.4 4.5 11.0 0.110 180.6 79.25 -0.8 1.94 6.13 26.3 30.3 31.1 6.54 17.9 13.2 4.8 12.0 0.120 188.2 79.02 -1.0 2.11 6.14 27.5 31.5 32.5 6.52 18.7 13.8 5.0 Values @ Failure -0.5 1.76 6.12 24.7 28.7 29.2 6.55 16.8 12.4 4.5 Failure criteria used* 3 *Note: "1" = Max Deviator Stress; "2" = Deviator Stress @ 15% Strain; "3" = Max Eff.Stress Ratio(d1/d3) Page 1 of 7 TIMELY ENGINEERING .SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 liL Fax:770-923-8973 Li Tested By EB/KP Date 01/07/21 Checked By AST A s H Cll Web: www.test-Ilc.com T ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # 20-623 Laboratory Project # 2160-03-1 Project Name American Thread Sample Type UD Sample ID 36977/B-2 Depth/Elev. 8-10.5' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION (initial) (final) Height, in 5.562 5.610 Mass of Wet Sample and Tare, g 967.30 961.30 Diameter, in 2.795 2.768 Mass of Dry Sample and Tare, g 647.84 647.84 Height -to -Diameter Ratio 2.0 2.0 Mass of Tare, g 0.00 0.00 Area, in2 6.14 6.02 Moisture, % 49.31 48.39 Volume, cm3 559.40 553.40 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 967.30 961.30 Volume change (Consolidation), ml -6.0 Mass of Dry Sample, g 647.84 647.84 Machine Speed, in / min 0.0100 Wet Density, pcf 107.9 108.4 Strain Rate, % / min 0.18 Dry Density, pcf 72.3 73.1 Chamber Pressure, psi 88.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure, psi 80.0 Volume of Solids, cm3 239.94 239.94 Eff. Consol. Stress,(Minor pr. stress, a3),psi 8.0 Volume of Voids, cm3 319.46 313.46 Change in Height, in -0.048 Void Ratio 1.33 1.31 "B" Value 0.95 % Saturation 100.0 100.0 SHEAR DATA Deformation Stage 2 (inch) Total Deformation ST.1 + ST.2 (inch) Axial Load (lb) Pore -Water Pressure, psi P Strain Stage 2 / Corrected 2 Area (in) Dev.Stress 06 6 ( s) (psi)Total Major Principal Stress,psi Effective Stress Ratio d /rs' 3 P' (a i+a 3)/2 (psi) Q (ai o3)/2 (psi) Eff. Minor Pr. Stress a3 (psi) ' Total Strain ST.1 + ST.2 Total, U Chan e,DU 9 a . a Eff' 0.000 0.072 24.7 80.00 0.0 0.00 6.02 0.0 8.0 8.0 1.00 8.0 0.0 8.0 1.27 0.005 0.077 48.3 80.60 0.6 0.09 6.03 3.9 11.9 11.3 1.53 9.4 2.0 7.4 1.36 0.010 0.082 63.2 80.93 0.9 0.18 6.03 6.4 14.4 13.5 1.90 10.3 3.2 7.1 1.44 0.015 0.087 77.0 81.09 1.1 0.27 6.04 8.7 16.7 15.6 2.25 11.2 4.3 6.9 1.53 0.020 0.092 90.8 81.12 1.1 0.36 6.04 10.9 18.9 17.8 2.59 12.4 5.5 6.9 1.62 0.025 0.097 105.3 81.08 1.1 0.45 6.05 13.3 21.3 20.2 2.93 13.6 6.7 6.9 1.71 0.030 0.102 120.4 81.00 1.0 0.53 6.05 15.8 23.8 22.8 3.26 14.9 7.9 7.0 1.80 0.035 0.107 137.4 80.85 0.8 0.62 6.06 18.6 26.6 25.8 3.60 16.5 9.3 7.2 1.88 0.040 0.112 152.7 80.72 0.7 0.71 6.06 21.1 29.1 28.4 3.90 17.8 10.6 7.3 1.97 0.050 0.122 182.4 80.50 0.5 0.89 6.07 26.0 34.0 33.5 4.46 20.5 13.0 7.5 2.15 0.060 0.132 207.9 80.30 0.3 1.07 6.08 30.1 38.1 37.8 4.91 22.8 15.1 7.7 2.32 0.070 0.142 225.1 80.10 0.1 1.25 6.10 32.9 40.9 40.8 5.16 24.3 16.4 7.9 2.50 0.080 0.152 237.3 79.96 0.0 1.43 6.11 34.8 42.8 42.9 5.33 25.4 17.4 8.0 2.68 0.090 0.162 248.1 79.77 -0.2 1.60 6.12 36.5 44.5 44.7 5.44 26.5 18.3 8.2 2.85 0.100 0.172 259.3 79.53 -0.5 1.78 6.13 38.3 46.3 46.7 5.52 27.6 19.1 8.5 3.03 0.110 0.182 265.3 79.40 -0.6 1.96 6.14 39.2 47.2 47.8 5.56 28.2 19.6 8.6 3.20 0.120 0.192 271.9 79.22 -0.8 2.14 6.15 40.2 48.2 49.0 5.58 28.9 20.1 8.8 3.38 0.130 0.202 277.7 79.07 -0.9 2.32 6.16 41.1 49.1 50.0 5.60 29.5 20.5 8.9 3.56 0.140 0.212 282.9 78.90 -1.1 2.50 6.17 41.8 49.8 50.9 5.60 30.0 20.9 9.1 3.73 0.150 0.222 288.1 78.72 -1.3 2.67 6.19 42.6 50.6 51.9 5.59 30.6 21.3 9.3 3.91 Values @ Failure -0.9 2.32 6.16 41.1 49.1 50.0 5.60 29.5 20.5 8.9 3.56 Failure criteria used* 3 'Note: "1" = Max Deviator Stress; "2" = Deviator Stress @ 15% Strain; "3" = Max Eff.Stress Ratio(dl/d3) ayc c VI 0 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 sltik Fax:770-923-8973 'l; Tested By FBiKP Date 01/08/21 Checked By ,... 5 H O Web: www.test-Ilacom T ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # 20-623 Laboratory Project # 2160-03-1 Project Name American Thread Sample Type UD Sample ID 36977/B-2 Depth/Elev. 8-10.5' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION (initial) (final) Height, in 5.460 5.518 Mass of Wet Sample and Tare, g 961.30 1235.70 Diameter, in 2.806 2.748 Mass of Dry Sample and Tare, g 647.84 950.64 Height -to -Diameter Ratio 1.9 2.0 Mass of Tare, g 0.00 302.80 Area, in2 6.19 5.93 Moisture, % 48.39 44.00 Volume, cm3 553.40 536.43 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 961.30 953.20 Volume change (Consolidation), ml -8.1 Mass of Dry Sample, g 647.84 661.93 Machine Speed, in / min 0.01000 Wet Density, pcf 108.4 110.9 Strain Rate, % / min 0.18 Dry Density, pcf 73.1 77.0 Chamber Pressure, psi 96.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure, psi 80.0 Volume of Solids, cm3 239.94 245.16 Eff. Consol. Stress,(Minor pr. stress, a3),psi 16.0 Volume of Voids, cm3 313.46 291.27 Change in Height, in -0.058 Void Ratio 1.31 1.19 "B" Value 0.95 % Saturation 100.0 100.0 SHEAR DATA Deformation Stage 3 (inch) Total Deformation ST.1 + ST.2 + ST.3 (inch) Axial Load (lb) Pore -Water Pressure, psi Strain Stage 3 Corrected Area (in2) Deviator Stress (Aa-aa3) r (psi) Major Principal Stress, psi Effective Stress Ratio a'l/a'3 P' (6 +a'3)/2 (psi) Q (ai a3)/2 (psi) Eff. Minor Pr. Stress% 63 (psi) Total Strain ST.1 + ST.2 + ST.3, Total, U Change,DU Total al Eff. di 0.000 0.164 26.3 80.00 0.0 0.00 5.93 0.0 16.0 16.0 1.00 16.0 0.0 16.0 2.89 0.010 0.174 97.1 82.27 2.3 0.18 5.94 11.9 27.9 25.6 1.87 19.7 6.0 13.7 3.06 0.020 0.184 137.3 82.93 2.9 0.36 5.95 18.6 34.6 31.7 2.43 22.4 9.3 13.1 3.24 0.030 0.194 174.6 82.95 2.9 0.54 5.96 24.9 40.9 37.9 2.90 25.5 12.4 13.1 3.41 0.040 0.204 214.5 82.73 2.7 0.73 5.98 31.5 47.5 44.8 3.37 29.0 15.7 13.3 3.59 0.050 0.214 254.9 82.47 2.5 0.91 5.99 38.2 54.2 51.7 3.82 32.6 19.1 13.5 3.77 0.070 0.234 322.3 82.12 2.1 1.27 6.01 49.3 65.3 63.1 4.55 38.5 24.6 13.9 4.12 0.100 0.264 381.2 81.75 1.8 1.81 6.04 58.7 74.7 73.0 5.12 43.6 29.4 14.2 4.65 0.120 0.284 406.2 81.42 1.4 2.18 6.06 62.6 78.6 77.2 5.30 45.9 31.3 14.6 5.00 0.150 0.314 435.8 80.83 0.8 2.72 6.10 67.2 83.2 82.3 5.43 48.7 33.6 15.2 5.53 0.170 0.334 451.1 80.44 0.4 3.08 6.12 69.4 85.4 85.0 5.46 50.3 34.7 15.6 5.88 0.200 0.364 472.3 79.83 -0.2 3.63 6.16 72.5 88.5 88.6 5.48 52.4 36.2 16.2 6.41 0.230 0.394 490.8 79.25 -0.8 4.17 6.19 75.0 91.0 91.8 5.48 54.3 37.5 16.8 6.93 0.260 0.424 507.3 78.66 -1.3 4.71 6.23 77.3 93.3 94.6 5.45 56.0 38.6 17.3 7.46 0.280 0.444 515.7 78.30 -1.7 5.07 6.25 78.3 94.3 96.0 5.42 56.9 39.2 17.7 7.81 0.310 0.474 530.0 77.72 -2.3 5.62 6.29 80.1 96.1 98.4 5.38 58.3 40.1 18.3 8.34 0.360 0.524 553.6 76.79 -3.2 6.52 6.35 83.1 99.1 102.3 5.32 60.8 41.5 19.2 9.22 0.410 0.574 575.2 75.89 -4.1 7.43 6.41 85.7 101.7 105.8 5.26 62.9 42.8 20.1 10.10 0.470 0.634 596.7 74.92 -5.1 8.52 6.48 88.0 104.0 109.0 5.17 65.1 44.0 21.1 11.16 0.520 0.684 616.5 74.11 -5.9 9.42 6.55 90.1 106.1 112.0 5.12 66.9 45.1 21.9 12.04 0.610 0.774 645.3 72.71 -7.3 11.06 6.67 92.8 108.8 116.1 4.99 69.7 46.4 23.3 13.62 0.670 0.834 664.1 71.76 -8.2 12.14 6.75 94.5 110.5 118.7 4.90 71.5 47.2 24.2 14.68 0.695 0.859 672.3 71.33 -8.7 12.60 6.79 95.2 111.2 119.8 4.86 72.3 47.6 24.7 15.12 Values @ Failure -0.2 3.63 6.16 72.5 88.5 88.6 5.48 52.4 36.2 16.2 6.41 Failure criteria used` 3 'Note: "1" = Max Deviator Stress; "2" = Deviator Stress @ 15% Strain; "3" = Max Eff.Stress Ratio(a'1/a'3) Page 3of7 Ttht TIMELY ENGINEERING SoIL TESTS, LLC Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com 1874 Forge Street Tucker, GA 30084 IC/=t AASHIO A C= F i E a ITC 6 Tested By EB/KP Date 01/08/21 Check affe ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # Project Name Sample ID Location 20-623 American Thread 36977/B-2 Laboratory Project # 2160-03-1 Sample Type UD Depth/Elev. 8-10.5' Additional Info Shear Stress, psi 90 80 70 60 50 40 30 20 10 0 Total and Effective Mohr's Circles y - 0.90 5x + R2= 1 365 0.99 9 0 10 20 30 40 50 60 Normal Stress, psi y=0 70 874x R2=1. + 2.2 000 80 13 90 Effective Consolidation Stress, psi Deviator Stress at Failure, psi Effective Minor Principal Stress at Failure, psi Effective Major Principal Stress at Failure, psi Axial Strain at Failure, % ST. 1 ST. 2 ST. 3 4.0 8.0 16.0 24.7 41.1 72.5 4.5 8.9 16.2 29.2 50.0 88.6 1.76 2.32 3.63 STRENGTH PARAMETERS* Total Effective 4° 41.2 1iO 42.2 C, psi 2.2 C', psi 1.4 *Valid only for Received Material at Reported Densities and Moisture Contents. Please see remarks on page 6 of this report Page 4 of 7 Jam. TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com ALAS.1-1 Tech EB/KP Date 01/08/21 Check ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # Project Name Sample ID Location 20-623 American Thread 36977/B-2 Laboratory Project # Sample Type Depth/Elev. Additional Info 2160-03-1 UD 8-10.5' 80 70 60 50 Q 40 0 30 20 10 0 P'- Q GRAPH 116111111111111111161 •u•u•urnu 0 10 20 30 40 P', psi 50 60 70 80 FAILURE SKETCH Ss a, psi a, degree 0.9 33.9 Page 5 of 7 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com cslk AASHIO Tested By EB/KP Date 01/08/21 Check Ffr ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # Project Name Sample ID Location 20-623 American Thread 36977/B-2 Laboratory Project # Sample Type Depth/Elev. Additional Info 2160-03-1 UD 8-10.5' Deviator Stress, AG, psi 100 90 80 70 60 50 40 30 20 10 0 Deviator Stress - Strain Graph opormommum idm • din idlighdbm rid 1 2 3 4 5 6 7 8 9 10 Balance ID Number Oven ID Number Deformation Indicator ID # Digital Caliper ID # Load Cell ID # Apparatus ID # NOTES: 1. Method for Saturation 2. Method for determination of cross -sectional area after consol. 3. Final moisture content (Stage 3) obtained from entire sample Total Axial Strain, % 11 12 13 14 15 16 REMARKS 563/700 Material from shelby tube was not homogeneous and/or not 496/610 long enough to select 3 uniform specimens 6" long each. 178/349/689 Most representative portion of sample (3" above the bottom 370/458 of shelby tube) was selected for multi -stage triaxial testing 11/347/692 (per ASTM STP 883). Application of safety factors to 10/293/693 results of this report is recommended due to not uniformity of material on site, oversize particles (>#4 sieve) which were observed and soil testing method was used for man-made material. DESCRIPTION Black Silty Sand WET B LL PL PI Gs USCS (ASTM D2487: D2488) SM Page 6 of 7 ki TIMELY ENGINEERING SoIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com A.ASHIO n.. w s o I Y! 6 Tested By EB/KP Date 01/08/21 Check doter ASTM D 4767/AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils (Multistage per ASTM STP 883) Client Project # Project Name Sample ID Location 20-623 American Thread 36977/B-2 Laboratory Project # Sample Type Depth/Elev. Additional Info 2160-03-1 UD 8-10.5' 5 3 1 5 7 9 0 Pore Pressure - Strain Graph 2 3 4 5 6 7 8 9 10 Total Axial Strain, 11 12 13 14 15 16 Effective Stress Ratio -Strain Graph 7.00 00 6.00 A 1-- A - — k " k — A — A — -A—A. +r 5.00 R vi 4.00 7 w N 3.00 fil • w w 2.00 1.00 0.00 2.00 4.00 6.00 Total 8.00 Axial Strain, % 10 00 12 00 14 00 16 Page 7 of 7 TIMELY 1874 Forge Street Tucker, GA 30084 ENGINEERING SOIL TESTS, LLC Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com AASHI❑ RGGRe OITC6 Tested By Date EB 01/07/21 Checked By igeer Client Pr. # Pr. Name Sample ID Location 20-623 American Thread 36977/B-2 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 UD 8-10.5' ASTM D 4318 Standard Test Method for Liquid Limit, Plastic Limit, and Plasticity Index of Soils (Atterberg Limits) Number of Blows Weight of Wet Sample & Tare, g Weight of Dry Soil & Tare, g Weight of Tare, g Moisture Content, % MOISTURE CONTENT 58 57 56 55 54 53 52 51 50 LIQUID LIMIT 9 9 39.60 38.21 34.85 34.78 25.10 27.70 48.72 48.45 Liquid Limit Device ID # NOTES: 1. Material appears to be Nonplastic. (Liquid Limit or Plastic Limit test could not be performed.) 2. Material passing No. 40 sieve was used for test. NONPLASTIC 10 Weight of Wet Soil & Tare, g Weight of Dry Soil & Tare, g Weight of Tare, g Moisture Content, % Weight of Wet Soil & Tare, g Weight of Dry Soil & Tare, g Weight of Tare, g Moisture Content, % DESCRIPTION USCS (ASTM D2487;2488) 20 30 40 NUMBER OF BLOWS PLASTIC LIMIT 40.58 44.79 35.58 38.33 25.35 25.06 48.88 48.68 NATURAL MOISTURE 771.50 662.80 361.30 36.05 Black Silty Sand SM Oven ID Number Balance ID Number LIQUID LIMIT (LL) PLASTIC LIMIT (PL) PLASTICITY INDEX (PI) LIQUIDITY INDEX (LI) AASHTO (M 145) 100 56 15/496/610 139/563 NP NP NP NA TIMELY ENGINEERING SOIL TEST'S, LLC 11874 Forge Street Tucker, GA Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com 30084 Tested By Date Checked By n T.E. n S.T. IH 01/07/21 AASH 0 hG G Rel]ITCO Ale Client Pr. # Pr. Name Sample ID Location 20-623 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 American Thread UD 36977/B-2 8-10.5' - - ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311; Particle Size Analysis (Split Sieve) MOISTURE CONTENT of TOTAL Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % SAMPLE MOISTURE CONTENT of FINE MATERIAL Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % 771.5 307.90 662.8 292.20 361.3 89.20 36.1 7.7 TOTAL Mass of wet sample before splitting & tare, g Mass of Tare, g TOTAL Mass of dry sample, g Mass of Wet Fine Material & Tare, g Mass of Tare, g Mass of Dry Fine Material, g % of Total Sample Passing Split Sieve 874.0 158.20 0.0 0.00 642.4 146.84 85.0 SIEVE ANALYSIS* Mass of Tare, Sieve Size 12" 3" 2.5" 2" 1.5" 1" .75" 5" .375" #4 COARSE g MATERIAL % RETAINED % PASSING Mass of Tare, g Sieve Size #10 #20 #40 #60 #100 #200 * - ASTM Defini " - AASHTO Definitions FINE MATERIAL % PASSING (of Total) 0.0 0.00 Sample & Tare, g Cumulative Mass retained, g COBBLES 0.0 100.0 COARSE GRAVEL 0.0 100.0 0.0 100.0 MEDIUM SAND 40.91 61.3 0.0 100.0 67.84 45.7 0.0 100.0 FINE SAND 85.02 35.8 0.0 100.0 95.99 29.4 FINE GRAVEL 0.0 0.0 100.0 106.94 23.1 13.0 2.0 98.0 FINES 119.59 15.8 22.5 3.5 96.5 ions of Classification of Classification COARSE SAND 96.2 15.0 85.0 NOTE: Sieve # 4 (4.75 mm) Sieve used for splitting sample on fine and coarse material PARTICLE -SIZE ANALYSIS' Oven ID # Balance ID# Shaker ID # REMARKS 15/496/610 % COBBLES % COARSE Gravel % FINE Gravel % COARSE Sand 0.0 % MEDIUM Sand % FINE Sand % FINES % TOTAL SAMPLE 25.5 139/142/700 0.0 20.0 555 15.0 15.8 23.7 100.0 PARTICLE -SIZE ANALYSIS"" COBBLES % COARSE Gravel (Stone) % MEDIUM Gravel (Stone) % FINE Gravel (Stone) 0.0 % COARSE Sand % FINE Sand % FINES (Silt -Clay) % TOTAL SAMPLE 25.5 0.0 20.0 3.5 15.8 35.2 100.0 DESCRIPTION USCS (ASTM D2487; Black Silty Sand D2488) AASHTO (M 145) Page 1 of 2 SM NA TIMELY 11874 Forge Street Tucker, GA 30084 '1".. S.T. ENGINEERING Tested By IH SOIL Phone: 770-938-8233 Fax: 770-923-8973 Date 01/07/21 AAA Checked By TESTS, LLC Web: www.test-Ilc.com A G G R r O I r e G Client Pr. # Pr. Name Sample ID Location 20-623 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 American Thread UD 8-10.5' 36977/B-2 - - ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311 Standard Test Method for Particle -Size Analysis of Soils and Aggregates (Split Sieve) Particle -Size Analysis , s M cJ �. '^ � N O imk G G VC C 8ik 8ik O 100 90 • • • . • • • • • • •• • •• • 80 70 P 60 A S 50 S I N 40 G 30 20 10 0 1000 100 10 1 0 1 0.01 0.001 Grain size in millimeters Coarse Fine Coarse Medium Fine Silt or Clay Boulders Cobbles Gravel Sand Fines Dto NA mm D30 NA mm D60 NA mm Cu NA Cc NA Project's Specific % Passing NA Page 2 of 2 Project's Specific Particle Size, mm NA 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Tested By Date Checked By TIMELY T.E. S.T. ENGINEERING IH SOIL TESTS, LLC 01/06/21 Ale Web: www.test-Ilc.com A+� ACCREDITED Client Pr. # 20-623 Lab. PR. # 2160-03-1 Pr. Name American Thread S. Type UD Sample ID 36977/B-2 Depth/Elev. 8-10.5' Location - Add. Info - ASTM D 2166; Standard Test Method for Unconfined Compressive Strength of Soils SAMPLE DATA STRESS GRAPH `" -STRAIN Initial Height, in 5.702 Stress, psi Initial Diameter, in 2.860 Height -to -Diameter Ratio 1.99 Initial Area, in2 ---•- 6.42 Initial Volume, in3 36.63 Mass of Sample, g 825.90 Wet Density, pcf 85.89 Dry Density, pcf 63.10 10 20 30 Machine Speed, in/min 0.025 Strain, Strain Rate, % / min 0.44 WATER CONTENT DETERMINATION Note: Water content was obtained after shear f om partial sample. Mass of Wet Sample and Tare, g 771.50 TEST DATA Mass of Dry Sample and Tare, g 662.80 Mass of Tare, g 361.30 Load Cell ID # 11 Digital Caliper ID # 16 Moisture, % 36.1 Apparatus ID # 10 Deformation Indicator ID # 9/93 REMARKS Elapsed Time (min) Deformation (inch) Axial Load (lb) Total Strain (%) Corrected Area (in2) Compressive Stress (psi) Portion of sample used for UCS test was above the bottom of the shelby tube. located 12" 0.0 0.000 4 0.0 6.42 0.0 0.4 0.010 5 0.2 6.44 0.2 0.8 0.020 9 0.4 6.45 0.8 1.2 0.030 12 0.5 6.46 1.2 Failure Code 3 2.0 0.050 18 0.9 6.48 2.2 3.0 0.075 22 1.3 6.51 2.8 Failure Sketch 4.0 0.100 18 1.8 6.54 2.1 5.0 0.125 15 2.2 6.57 1.7 Failure Type: Shear DESCRIPTION Black Silty Sand USCS (ASTM D2487: D2488) UNCONFINED COMPRESSIVE STRENGTH AT FAILURE, q (psi) 2.8 SM UNCONFINED SHEAR STRENGTH AT FAILURE, si, (psi) 1.4 Balance ID Number 1/7 STRAIN AT FAILURE, % 1.3 Oven ID Number 12/13/14 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 '1;1,+..T: Phone: 770-938-8233 rLAir Tested By EB/KP .11 Fax: 770-923-8973 Date 01/09/21 Web: www.test-11c.com Checked By ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # 2160-03-1 Pr. Name American Thread Sample Type Remold Sample ID 36978/B-5 Depth/Elevation 0-3' Location Black Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION (initial) (final) Height, in 6.000 5.977 Mass of Wet Sample and Tare, g 282.30 1302.40 Diameter, in 2.875 3.040 Mass of Dry Sample and Tare, g 229.00 975.25 Height -to -Diameter Ratio 2.1 2.0 Mass of Tare, g 94.90 303.10 Area, in 6.49 7.26 Moisture, % 39.75 48.67 Volume, cm' 638.29 710.88 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 939.30 998.80 Mass of Dry Sample, g 672.15 671.81 Machine Speed, in / min 0.0100 Wet Density, pcf 91.9 87.7 Strain Rate, %/ min 0.17 Dry Density, pcf 65.7 59.0 Chamber Pressure, psi 83.0 Specific Gravity (assumed) 1.750 1.750 Back Pressure,psi 80.0 Volume of Solids, cm' 384.08 383.89 Eff. Consol. Stress,(Minor pr. stress, a3),psi 3.0 Volume of Voids, cm' 254.21 326.99 Change in Height, in 0.023 Void Ratio 0.66 0.85 "B" Value 0.95 % Saturation 105.1 100.0 SHEAR DATA Elapsed Time (min) Deformation (inch) Axial Load (lb) Pore Pressure,psi -Water p Total Strain (%) Corrected Area (in) Dev.Stress A =a -a ( 1 s) (psi) Major Principal Stress,psi p Eff.Stress Ratio a,/a 3 P' (a'1+a 3)/2 (psi) Q 7 [(a1-a3)/2] (psi) Eff. Minor Pr. Stress a'3 (psi) Total,U Change,4U Total a1 Eff. a'1 0.0 0.000 13.5 80.0 0.0 0.00 7.26 0.0 3.0 3.0 1.00 3.0 0.0 3.0 1.0 0.010 35.0 80.4 0.4 0.17 7.27 3.0 6.0 5.5 2.14 4.1 1.5 2.6 2.0 0.020 51.5 80.4 0.4 0.33 7.28 5.2 8.2 7.9 2.98 5.3 2.6 2.6 3.0 0.030 66.6 80.2 0.2 0.50 7.29 7.3 10.3 10.1 3.57 6.5 3.6 2.8 4.0 0.040 85.7 79.9 -0.1 0.67 7.31 9.9 12.9 13.0 4.16 8.1 4.9 3.1 5.0 0.050 107.6 79.5 -0.5 0.84 7.32 12.9 15.9 16.3 4.71 9.9 6.4 3.5 7.0 0.070 163.1 78.6 -1.4 1.17 7.34 20.4 23.4 24.8 5.60 14.6 10.2 4.4 10.0 0.100 257.9 76.5 -3.5 1.67 7.38 33.1 36.1 39.6 6.09 23.1 16.6 6.5 12.0 0.120 316.1 74.9 -5.1 2.01 7.41 40.9 43.9 49.0 6.03 28.6 20.4 8.1 15.0 0.150 384.1 72.5 -7.5 2.51 7.44 49.8 52.8 60.3 5.74 35.4 24.9 10.5 17.0 0.170 421.1 71.1 -8.9 2.84 7.47 54.6 57.6 66.5 5.58 39.2 27.3 11.9 20.0 0.200 465.7 69.2 -10.8 3.35 7.51 60.2 63.2 74.0 5.38 43.9 30.1 13.8 24.0 0.240 509.0 67.3 -12.7 4.02 7.56 65.5 68.5 81.3 5.16 48.5 32.8 15.7 29.0 0.290 547.7 65.3 -14.7 4.85 7.63 70.0 73.0 87.7 4.96 52.7 35.0 17.7 35.0 0.350 581.2 63.5 -16.5 5.86 7.71 73.6 76.6 93.1 4.78 56.3 36.8 19.5 40.0 0.400 600.4 62.4 -17.6 6.69 7.78 75.4 78.4 96.0 4.67 58.3 37.7 20.6 45.0 0.450 615.1 61.5 -18.5 7.53 7.85 76.7 79.7 98.1 4.57 59.8 38.3 21.5 49.0 0.490 625.7 61.0 -19.0 8.20 7.91 77.4 80.4 99.4 4.52 60.7 38.7 22.0 59.0 0.590 642.4 60.0 -20.0 9.87 8.05 78.1 81.1 101.1 4.39 62.1 39.0 23.0 23.8-1 24.1 69.0 0.690 650.3 59.2 -20.8 11.54 8.21 77.6 80.6 101.4 4.27 62.6 38.8 79.0 0.790 656.3 58.9 -21.1 13.22 8.36 76.9 79.9 101.0 4.18 62.6 38.4 84.0 0.840 657.5 58.8 -21.2 14.05 8.44 76.3 79.3 100.5 4.15 62.4 38.1 24.2 90.0 0.900 660.1 58.8 -21.2 15.06 8.54 75.7 78.7 99.9 4.12 62.1 37.8 24.2 Values @ Failure -3.5 1.67 7.38 33.1 36.1 39.6 6.09 23.1 16.6 6.5 Failure criteria used' I 3 'Note:"1"=Max Deviator Stress;"2"=Deviator Stress @ 15% Strain;"3"=Max Eff.Stress Ratio(a'i/a'3) Pnno 1 of 7 Triaxial CU.xls [AJ, REV. 1; 10-10-05 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com Tested By EB/KP Date 01/10/21 ~ Checked By Client Pr. # Pr. Name Sample ID Location ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils 20-623 American Thread 36978/B-5 Black Laboratory Project # Sample Type Depth/Elevation Additional Info 2160-03-1 Remold 0-3' SPECIMEN PROPERTIES Height, in Diameter, in Height -to -Diameter Ratio Area, in` Volume, cm' Mass of Wet Sample, g Mass of Dry Sample, g Wet Density, pcf Dry Density, pcf Specific Gravity Volume of Solids, cm' Volume of Voids, cm' Void Ratio % Saturation (assumed) (initial) (after consol.) 6.000 5.967 2.875 3.030 2.1 2.0 6.49 7.21 638.29 704.98 938.90 992.40 671.86 670.64 91.8 87.9 65.7 59.4 1.750 1.750 383.92 383.22 254.37 321.76 0.66 0.84 105.0 100.0 WATER CONTENT DETERMINATION initial) Mass of Wet Sample and Tare, g Mass of Dry Sample and Tare, g Mass of Tare, g Moisture, % (final) 282.30 1298.40 229.00 976.06 94.90 304.20 39.75 47.98 TEST DATA PRIOR TO LOADING Machine Speed, in / min Strain Rate, % / min Chamber Pressure, psi Back Pressure,psi Eff. Consol. Stress,(Minor pr. stress, a3),psi Change in Height, in "B" Value SHEAR DATA 0.0100 0.17 86.0 80.0 6.0 0.033 0.95 Elapsed Time (min) Deformation (inch) Axial Load (lb) Pore -Water Pressure,psi Total,U Change,4U Total Strain (%) Corrected Area (in2) Dev.Stress (06=61-63) (psi) Major Principal Stress,psi Total al Eff. a'1 Eff.Stress Ratio 6'J/63 P' ((31+6'3)/2 (psi) Eff. Minor Pr. Stress a'3 (psi) 0.0 0.000 21.2 80.0 0.0 0.00 7.21 0.0 6.0 6.0 1.00 6.0 0.0 6.0 1.0 0.010 52.1 81.3 1.3 0.17 7.22 4.3 10.3 9.0 1.90 6.9 2.1 4.7 2.0 0.020 70.4 81.7 1.7 0.34 7.23 6.8 12.8 2.60 7.7 3.4 4.3 3.0 0.030 90.1 81.9 1.9 0.50 7.25 9.5 15.5 13.6 3.30 8.9 4.8 4.1 4.0 0.040 114.2 81.8 1.8 0.67 7.26 12.8 18.8 17.0 4.04 10.6 6.4 4.2 5.0 0.050 142.9 81.4 1.4 0.84 7.27 16.7 22.7 21.3 4.66 12.9 8.4 4.6 7.0 0.070 212.0 80.3 0.3 1.18 7.30 26.1 32.1 31.9 5.55 18.8 13.1 5.7 10.0 0.100 309.3 77.8 - 2.2 1.68 7.33 39.3 45.3 47.5 5.78 27.9 19.6 8.2 12.0 0.120 360.2 76.1 -3.9 2.01 7.36 46.1 52.1 56.0 5.67 32.9 23.0 9.9 15.0 0.150 420.2 73.9 - 6.1 2.52 7.40 53.9 59.9 66.0 5.48 39.0 27.0 12.1 17.0 0.170 450.7 72.7 -7.3 2.85 7.42 57.9 63.9 71.1 5.36 42.2 28.9 13.3 20.0 0.200 487.4 71.2 - 8.8 3.35 7.46 62.5 68.5 77.3 5.22 46.1 31.2 14.8 24.0 0.240 522.7 69.5 -10.5 4.02 7.51 66.8 72.8 83.2 5.05 49.8 33.4 16.5 29.0 0.290 556.0 68.0 - 12.0 4.86 7.58 70.6 76.6 88.6 4.91 53.3 35.3 18.0 35.0 0.350 583.2 66.5 -13.5 5.87 7.66 73.4 79.4 92.9 4.76 56.2 36.7 19.5 40.0 0.400 599.7 65.6 - 14.4 6.71 7.73 74.9 80.9 95.2 4.67 57.8 37.4 20.4 45.0 0.450 614.4 65.0 -15.0 7.54 7.80 76.1 82.1 97.0 4.63 59.0 38.0 21.0 49.0 0.490 622.6 64.4 - 15.6 8.21 7.85 76.6 82.6 98.1 4.55 59.8 38.3 21.6 59.0 0.590 637.6 63.4 -16.6 9.89 8.00 77.0 83.0 99.7 4.40 61.2 38.5 22.6 69.0 0.690 650.1 62.6 - 17.4 11.57 8.15 77.1 83.1 100.5 4.30 62.0 38.6 23.4 79.0 0.790 659.6 62.1 -17.9 13.24 8.31 76.8 82.8 100.7 4.22 62.3 38.4 23.9 84.0 0.840 665.2 62.2 - 17.8 14.08 8.39 76.8 82.8 100.5 4.23 62.1 38.4 23.8 90.0 0.900 669.7 62.0 -18.0 15.08 8.49 76.4 82.4 100.4 4.18 62.2 38.2 24.0 Values @ Failure Failure criteria used* HI3 I`Note:"1"=Max Deviator Stress;"2"=Deviator Stress @ 15% Strain;"3"=Max Eff.Stress Ratio(6',/a'3) 27.9 19.6 8.2 5.78 39.3 45.3 47.5 -2.2 7.33 1.68 Page 2 of 7 Triaxial CUxls [B], REV 1; 10-10-05 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 rt A: Phone: 770-938-8233 I Tested By EB/KP IF Fax: 770-923-8973 Date 01/10/21 Web: wvuw.test-Ilc.com A S H d A C C R C 8 1 T C 6 Checked By Aief ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # 2160-03-1 Pr. Name American Thread Sample Type Remold Sample ID 36978/B-5 Depth/Elevation 0-3' Location Black Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION initial) (final) Height, in 6.000 5.948 Mass of Wet Sample and Tare, g 282.30 1289.40 Diameter, in 2.875 3.033 Mass of Dry Sample and Tare, g 229.00 969.42 Height -to -Diameter Ratio 2.1 2.0 Mass of Tare, g 94.90 297.20 Area, in` 6.49 7.22 Moisture, % 39.75 47.60 Volume, cm' 638.29 704.11 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 939.40 992.20 Mass of Dry Sample, g 672.22 672.22 Machine Speed, in / min 0.0100 Wet Density, pcf 91.9 88.0 Strain Rate, % / min 0.17 Dry Density, pcf 65.7 59.6 Chamber Pressure, psi 92.0 Specific Gravity (assumed) 1.750 1.750 Back Pressure,psi 80.0 Volume of Solids, cm' 384.12 384.12 Eff. Consol. Stress,(Minor pr. stress, 63),psi 12.0 Volume of Voids, cm' 254.17 319.98 Change in Height, in 0.052 Void Ratio 0.66 0.83 "B" Value 0.95 % Saturation 105.1 100.0 SHEAR DATA Elapsed Time (min)(inch)(lb) Deformation Axial Load ( ) Pore -Water Pressure,psi p Total Strain (%) Corrected Area (in) Dev.Stress 46=6 6 ( 3) (psi) Major Principal Stress, psi p Eff.Stress Ratio 6'%/6'3 P' (61+6'3)/2 (psi) Q [(6,-63)l2] (psi) Eff. Minor Pr. Stress 63 (psi) Total,U Change,4U Total al Eff.6'i 0.0 0.000 25.6 80.0 0.0 0.00 7.22 0.0 12.0 12.0 1.00 12.0 0.0 12.0 1.0 0.010 73.9 82.2 2.2 0.17 7.24 6.7 18.7 16.4 1.68 13.1 3.3 9.8 2.0 0.020 104.5 83.4 3.4 0.33 7.25 10.9 22.9 19.5 2.26 14.1 5.4 8.6 3.0 0.030 135.9 83.8 3.8 0.50 7.26 15.2 27.2 23.4 2.85 15.8 7.6 8.2 4.0 0.040 173.4 83.8 3.8 0.67 7.27 20.3 32.3 28.5 3.48 18.3 10.2 8.2 5.0 0.050 215.3 83.5 3.5 0.84 7.28 26.0 38.0 34.5 4.06 21.5 13.0 8.5 7.0 0.070 296.6 82.2 2.2 1.17 7.31 37.1 49.1 46.9 4.78 28.3 18.5 9.8 10.0 0.100 393.8 79.9 -0.1 1.68 7.35 50.1 62.1 62.2 5.16 37.1 25.1 12.1 12.0 0.120 441.8 78.6 -1.4 2.02 7.37 56.5 68.5 69.9 5.21 41.6 28.2 13.4 15.0 0.150 495.9 76.6 -3.4 2.52 7.41 63.5 75.5 78.9 5.11 47.2 31.7 15.4 17.0 0.170 524.4 75.5 -4.5 2.86 7.44 67.1 79.1 83.6 5.05 50.1 33.5 16.5 20.0 0.200 558.9 74.0 -6.0 3.36 7.48 71.3 83.3 89.3 4.97 53.6 35.7 18.0 24.0 0.240 595.5 72.4 -7.6 4.03 7.53 75.7 87.7 95.3 4.87 57.4 37.9 19.6 29.0 0.290 627.6 70.9 -9.1 4.87 7.59 79.3 91.3 100.4 4.75 60.8 39.6 21.1 35.0 0.350 656.6 69.3 -10.7 5.88 7.68 82.2 94.2 104.9 4.63 63.8 41.1 22.7 40.0 0.400 674.6 68.3 -11.7 6.72 7.74 83.8 95.8 107.5 4.54 65.6 41.9 23.7 45.0 0.450 689.3 67.5 -12.5 7.56 7.81 84.9 96.9 109.4 4.47 67.0 42.5 24.5 49.0 0.490 698.9 67.3 -12.7 8.24 7.87 85.5 97.5 110.3 4.46 67.5 42.8 24.7 59.0 0.590 717.1 66.2 -13.8 9.92 8.02 86.2 98.2 112.0 4.35 68.9 43.1 25.8 69.0 0.690 730.2 65.4 -14.6 11.60 8.17 86.2 98.2 112.8 4.25 69.7 43.1 26.6 79.0 0.790 739.9 64.9 -15.1 13.28 8.33 85.8 97.8 112.9 4.16 70.0 42.9 27.1 84.0 0.840 744.4 64.7 -15.3 14.12 8.41 85.5 97.5 112.8 4.13 70.1 42.7 27.3 90.0 0.900 751.7 64.7 -15.3 15.13 8.51 85.3 97.3 112.6 4.13 69.9 42.7 27.3 Values @ Failure -1.4 2.02 7.37 56.5 68.5 69.9 5.21 41.6 28.2 13.4 Failure criteria used* 3 "Note:"1 "=Max Deviator Stress;"2"=Deviator Stress @ 15% Strain;"3"=Max Eff.Stress Ratio(6'1/63) Page 3 of 7 Triaxial CU.xls [C], REV. 1; 10-10-05 Client Project # Project Name Sample ID Location T.E... S.T. TIMELY ENGINEERING SoIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com ,.SHIP] A 0 C R 4 Ll I Y L G Tested By Date Check EB/KP 01/10/21 ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Laboratory Project # Sample Type Depth/Elevation Additional Info 20-623 American Thread 36978/B-5 Black 2160-03-1 Remold 0-3' Shear Stress, psi Total and Effective Mohr's Circles y = 0.6881x + 6.4171 y = .7982x + : i 09 , 20 30 40 Normal Stress, psi B pecimen Effective Consolidation Stress, psi Deviator Stress at Failure, psi Effective Minor Principal Stress at Failure, psi Effective Major Principal Stress at Failure, psi Axial Strain at Failure, % c 3.0 6.0 12.0 33.1 39.3 56.5 6.5 8.2 13.4 39.6 47.5 69.9 1.67 1.68 2.02 50 60 70 STRENGTH PARAMETERS* Total Effective 4) ° 34.5 4)' ° 38.6 C, psi 6.4 C', psi 2.5 *Valid only for Received Material at Reported Densities and Moisture Contents. Please see remarks on page 6 of this report Triaxial CU.xls [Mohr's Circles], REV. 1; 10-10-05 Page 4 of 7 Phone: 770-938-8233 Fox 770'823'8873 Web: www.test-llc.com 1874 Forge Street Tucker, GA 30084 4;�:A AASHN0 Aa C P a �'��0 Tested By EB/KP ASrmm*767/AA8uTVTzv7 Standard Test Method for Consolidated u"un`in,uTnxxial Compression Test for Cohesive Soils Client Ft# 20-623 Laboratory Project # Pr. Name American Thread Sample Type Sample ID 30978/B'5 Depth/Elevation Location Black Additional Info Date 01/10/21 Check -450 210U-031 Remold O 10 20 P" ~ Q Graph 30 40 P', psi 50 60 0 80 0 60 50 30 20 10 O 80 A REMOLDING PROPERTIES A m mCompaction mMax Dry Density mDifference from Optimum m.c 94.9 3.1 31 FAILURE SKETCH B a, psi a, degree 21 32.1 TIMELY ENGINEERING SoIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com A A S H I O ADMRICOJTED Tested By EB/KP Date 01/10/21 Check 457 Client Pr. # Pr. Name Sample ID Location ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Laboratory Project # Sample Type Depth/Elevation Additional Info 20-623 American Thread 36978/B-5 Black 2160-03-1 Remold 0-3' Deviator Stress, Au, psi 90 80 - 70 - 60 50 40 30 - Stress - Strain Graph 20 JY■� 411111111111111111111101 10 0r 0 1 2 3 4 5 6 7 8 Axial Strain, 9 10 11 12 13 14 15 16 Balance ID Number Oven ID Number Deformation Indicator ID # Digital Caliper ID # Load Cell ID # Apparatus ID # REMARKS DESCRIPTION 563/700 496/610 178/349/689 370/458 347/692/815 293/693/814 Samples (Material passing #4 Sieve) were remolded to specified % compaction and moisture content of Standard Proctor values. Application of safety factors to results of this report is recommended due to not uniformity of material on site and soil testing method was used for man-made material. Black Silty Sand with Gravel NOTES: 1. Method for Saturation 2. Method for determination of cross -sectional after consolidation 3. Initial specimen moisture content obtained from cuttings 4. Final specimen moisture content obtained from entire sample WET B LL PL PI Gs USCS (ASTM D2487: D2488) SM Triaxial CU.xls [Stress -Strain GRAPH], REV. 1; 10-10-05 Pagr 6 of 7 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Tested By EB/KP Date Check 01/10/21 _ ..A. A. SH ID Web: www.test-Ilc.com r ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # 2160-03-1 Pr. Name American Thread Sample Type Remold Sample ID 36978/B-5 Depth/Elevation 0-3' Location Black Additional Info - Pore Pressure - Strain Graph A Pore Pressure, psi 4> A N O CO A N O N i its, Sin ■■■■■■ ■■■■■■ • Era 11•••••••• • MEEVA 6,-MME • El • ME M .■■■MIEE!IM■ IliiiiiiC■E:L!!!■ IILhh1flii.i..il -20 0 ..17... -22 0 2 3 4 5 6 7 8 9 10 11 12 13 14 Axial Strain, % 15 16 Effective Stress Ratio -Strain Graph 7.00 A 6.00 o 5.00 i ea C i — . cn 4.00 N R N 3.00 to 7 2.00 • w 1.00 0.00 0 2 4 6 8 10 12 14 16 Axial Strain,% Triaxial CU.xls [Stress Ratio & Pore Water Pr. -Strain GRAPH], REV. 1; 10-10-05 Page 7 of 7 TIMELY 1874 Forge Street Tucker, GA 30084 ENGINEERING SOIL TESTS, LLC Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com AASHI❑ RGGRe OITC6 Tested By Date EB 01/07/21 Checked By igeer Client Pr. # Pr. Name Sample ID Location 20-623 American Thread 36978/B-5 Black Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 Bulk 0-3' ASTM D 4318 Standard Test Method for Liquid Limit, Plastic Limit, and Plasticity Index of Soils (Atterberg Limits) Number of Blows Weight of Wet Sample & Tare, g Weight of Dry Soil & Tare, g Weight of Tare, g Moisture Content, % MOISTURE CONTENT 58 57 56 55 54 53 52 51 50 LIQUID LIMIT 6 6 42.02 35.41 37.53 30.79 28.24 21.30 48.33 48.68 Liquid Limit Device ID # NOTES: 1. Material appears to be Nonplastic. (Liquid Limit or Plastic Limit test could not be performed.) 2. Material passing No. 40 sieve was used for test. NONPLASTIC 10 Weight of Wet Soil & Tare, g Weight of Dry Soil & Tare, g Weight of Tare, g Moisture Content, % Weight of Wet Soil & Tare, g Weight of Dry Soil & Tare, g Weight of Tare, g Moisture Content, % DESCRIPTION USCS (ASTM D2487;2488) 20 30 40 NUMBER OF BLOWS PLASTIC LIMIT 36.63 37.56 33.65 34.75 27.51 28.99 48.53 48.78 NATURAL MOISTURE 813.70 718.00 306.50 23.26 Black Silty Sand with Gravel SM Oven ID Number Balance ID Number LIQUID LIMIT (LL) PLASTIC LIMIT (PL) PLASTICITY INDEX (PI) LIQUIDITY INDEX (LI) AASHTO (M 145) 100 56 15/496/610 139/563 NP NP NP NA TIMELY ENGINEERINGPhone: SOIL TEST'S, LLC 1874 Forge Street Tucker, GA 770-938-8233 Fax: 770-923-8973 Web: www.test-11c.com 30084 Tested By Date Checked By n T.E. A S.T. IH 01/06/21 A A G G R C O T co Ale Client Pr. # Pr. Name Sample ID Location 20-623 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 American Thread Bulk 36978/B-5 0-3' Black - ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311; Particle Size Analysis (Split Sieve) MOISTURE CONTENT of TOTAL Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % SAMPLE MOISTURE CONTENT of FINE MATERIAL Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % 813.7 341.90 718.0 280.60 306.5 93.90 23.3 32.8 TOTAL Mass of wet sample before splitting & tare, g Mass of Tare, g TOTAL Mass of dry sample, g Mass of Wet Fine Material & Tare, g Mass of Tare, g Mass of Dry Fine Material, g % of Total Sample Passing Split Sieve 18540.0 194.40 0.0 0.00 15041.8 146.35 84.5 SIEVE ANALYSIS* Mass of Tare, Sieve Size 12" 3" 2.5" 2" 1.5" 1" .75" 5" .375" COARSE g MATERIAL % RETAINED % PASSING Mass of Tare, g Sieve Size #4 #10 #20 #40 #60 #100 #200 * - ASTM Defini " - AASHTO Definitions FINE MATERIAL % PASSING (of Total) 0.0 0.00 Sample & Tare, g Cumulative Mass retained, g COBBLES 0.0 100.0 COARSE GRAVEL 0.0 100.0 COARSE SAND 15.94 75.3 0.0 100.0 MEDIUM SAND 49.40 56.0 0.0 0.0 100.0 72.68 42.5 154.0 1.0 99.0 FINE SAND 87.85 33.8 375.0 2.5 97.5 97.01 28.5 FINE GRAVEL 798.0 5.3 94.7 105.61 23.5 1755.0 11.7 88.3 FINES 116.95 17.0 2329.0 15.5 84.5 ions of Classification of Classification NOTE: Sieve 3/8" (9.5 mm) Sieve used for splitting sample on fine and coarse material PARTICLE -SIZE ANALYSIS' Oven ID # Balance ID# Shaker ID # REMARKS 15/496/610 % COBBLES % COARSE Gravel % FINE Gravel % COARSE Sand 0.0 % MEDIUM Sand % FINE Sand % FINES % TOTAL SAMPLE 22.2 139/142/700 5.3 16.8 555 19.4 17.0 19.3 100.0 PARTICLE -SIZE ANALYSIS"" COBBLES % COARSE Gravel (Stone) % MEDIUM Gravel (Stone) % FINE Gravel (Stone) 0.0 % COARSE Sand % FINE Sand % FINES (Silt -Clay) % TOTAL SAMPLE 22.2 2.5 16.8 13.0 17.0 28.5 100.0 DESCRIPTION USCS (ASTM D2487; Black Silty Sand with Gravel D2488) AASHTO (M 145) Page 1 of 2 SM NA TIMELY 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 '1".. S.T. ENGINEERING Tested By IH SOIL Date 01/06/21 Web: www.test-Ilc.com SH CI A' Checked By Ale TESTS, LLC Client Pr. # Pr. Name Sample ID Location 20-623 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 American Thread Bulk 0-3' 36978/B-5 Black - ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311 Standard Test Method for Particle -Size Analysis of Soils and Aggregates (Split Sieve) Particle -Size Analysis , s M cJ �. � '^ � N 4.O imk G G VC C 8 8 O ik ik � 100 90 • • • • • • • ♦ • ♦ • • • ♦ • • • • ♦ • 80 70 P 60 A S so S I N 40 G 30 20 10 0 1000 100 10 1 0 1 0.01 0.001 Grain size in millimeters Coarse Fine Coarse Medium Fine Silt or Clay Boulders Cobbles Gravel Sand Fines D10 NA mm D30 NA mm D60 NA mm Cu NA Cc NA Project's Specific % Passing NA Page 2 of 2 Project's Specific Particle Size, mm NA TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com AASHI❑ AO G REG ITCD Tested By IH Date 01/07/21 Checked By Client Pr. # Pr. Name Sample ID Location 20-623 American Thread 36978/B-5 Black Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 Bulk 0-3' ASTM D 698; Standard Test Method for Laboratory Compaction Characteristics of Soil Using Standard Effort (12,400 ft-Ibf/ft3 (600kN-m/m3)) Mass of Soil before sieving, g Mass of Mat. Retained on No. 4 sieve, g Mass of Mat. Retained on 3/8" sieve, g Mass of Mat. Retained on 3/4" sieve, g Material Retained on No. 4 Sieve, % Material Retained on 3/8" Sieve, % Material Retained on 3/4" Sieve, % Total, % (oversized) Procedure Points Mass of Mold and Soil, g Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % Wet Density, pcf Dry Density, pcf USCS (ASTM D2487; D2488) AASHTO M145 DETERMINATION OF TEST PROCEDURE wet dry 18540.0 15041.8 2329.0 2329.0 15.5 15.5 TEST DATA MOISTURE CONTENT Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % Mold ID Number Mass of Mold, g Volume of Mold, ft3 Hammer ID Number Number of Blows per layer Number of Layers 1 2 3 4 5 6 5571.0 5639.0 5684.0 5668.0 465.1 437.7 407.4 443.8 395.6 357.4 335.3 353.3 178.8 126.4 139.3 116.7 32.1 34.8 36.8 38.3 87.3 91.8 94.8 93.7 66.1 68.1 69.3 67.8 SM NA Method A: Material retained on No. 4 Sieve< 25% Method B: Material retained on 3/8" Sieve < 25% Method C: Material retained on 3/4" Sieve < 30% Page 1 of 2 DESCRIPTION Coarse + Fine Fraction Coarse Fraction 813.7 2329.0 718.0 2329.0 306.5 0.0 23.3 0.0 798 4252.4 0.0333 318 3 25 Black Silty Sand with Gravel TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com AASHI❑ no°acoi7ev Tested By Date Checked By IH 01/07/21 Client Pr. # Pr. Name Sample ID Location 20-623 American Thread 36978/B-5 Black Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 Bulk 0-3' ASTM D 698; Standard Test Method for Laboratory Compaction Characteristics of Soil Using Standard Effort (12,400 ft-Ibf/ft3 (600kN-m/m3)) Dry Density, pcf Moisture vs. Dry Density 75 73 — 71 — 69 -- 67 -- 65 .... ... • 31 32 33 34 35 36 37 38 39 40 41 Moisture Content, % Maximum Dry Density, pcf Optimum Moisture Content, °A, 69.3 36.6 Corrected Maximum Dry Density, pcf Corrected Optimum Moisture Content, °A, Oversize Correction Data Mass of Saturated -Surface -Dry Specimen + Tare, g B Mass of Saturated Specimen in Water, g C Mass of Oven Dry Specimen + Tare, g A Mass of Tare, g Absorption of Oversize Particles, % Bulk Specific Gravity Average Absorption, Average Bulk Specific Gravity 72.2 30.9 1831.2 598.5 1629.1 436.9 17.0 1.50 17.0 1.50 LL PL PI MC Page 2 of 2 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Tested By Date Checked By TIMELY T.E. S.T. ENGINEERING IH SOIL TESTS, LLC 01/09/21 Ale Web: www.test-Ilc.com A+� ACCREDITED Client Pr. # 20-623 Lab. PR. # 2160-03-1 Pr. Name American Thread S. Type Bulk Sample ID 36978/B-5 Depth/Elev. 0-3' Location Black Add. Info - ASTM D 2166; Standard Test Method for Unconfined Compressive Strength of Soils SAMPLE DATA STRESS GRAPH "° -STRAIN Initial Height, in 6.000 Stress, psi Initial Diameter, in 2.875 Height -to -Diameter Ratio 2.09 Initial Area, in2 6.49 Initial Volume, in3 38.95 Mass of Sample, g 941.30 Wet Density, 92.06 pcf Dry Density, pcf 65.85 05 10 15 2.0 25 30 35 Machine Speed, in/min 0.025 Strain, Strain Rate, % / min 0.42 WATER CONTENT DETERMINATION Note: Water content was obtained after shear f om partial sample. Mass of Wet Sample and Tare, g 282.30 TEST DATA Mass of Dry Sample and Tare, g 229.00 Mass of Tare, g 94.90 Load Cell ID # 11 Digital Caliper ID # 16 Moisture, % 39.7 Apparatus ID # 10 Deformation Indicator ID # 9/93 REMARKS Elapsed Time (min) Deformation (inch) Axial Load (lb) Total Strain (%) Corrected Area (in2) Compressive Stress (psi) Material passed #4 sieve used for testing. remolded to 95.1 % of maximum dry density proctor) at 3.1% above optimum moisture Material was (standard content. 0.0 0.000 2 0.0 6.49 0.0 0.4 0.010 6 0.2 6.50 0.6 0.8 0.020 8 0.3 6.51 0.9 1.2 0.030 9 0.5 6.52 1.1 Failure Code 3 2.0 0.050 10 0.8 6.55 1.2 3.0 0.075 15 1.3 6.57 2.0 Failure Sketch 4.0 0.100 22 1.7 6.60 3.0 5.0 0.125 31 2.1 6.63 4.4 6.0 0.150 48 2.5 6.66 6.9 7.0 0.175 56 2.9 6.69 8.1 8.0 0.200 35 3.3 6.72 4.9 Failure Type: Cone and Shear DESCRIPTION Black Silty Sand with Gravel USCS (ASTM D2487: D2488) UNCONFINED COMPRESSIVE STRENGTH AT FAILURE, q (psi) 8.1 SM UNCONFINED SHEAR STRENGTH AT FAILURE, si, (psi) 4.0 Balance ID Number 1/7 STRAIN AT FAILURE, % 2.9 Oven ID Number 12/13/14 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 '1' Phone: 770-938-8233 Tested By CL74 EB/KP Fax:770-923-8973 Date AA5�1. 01/12/21 o Web: www.test-Ilc.com Checked By arier ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # 2160-03-1 Pr. Name American Thread Sample Type Remold Sample ID 36979/B-16 Depth/Elevation 20-25.0' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION (initial) (final) Height, in 6.000 5.984 Mass of Wet Sample and Tare, g 342.10 1578.80 Diameter, in 2.875 2.836 Mass of Dry Sample and Tare, g 298.30 1347.35 Height -to -Diameter Ratio 2.1 2.1 Mass of Tare, g 67.00 299.40 Area, in 6.49 6.32 Moisture, % 18.94 22.09 Volume, cm' 638.29 619.63 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 1246.40 1279.50 Mass of Dry Sample, g 1047.95 1048.04 Machine Speed, in / min 0.0100 Wet Density, pcf 121.9 128.9 Strain Rate, % / min 0.17 Dry Density, pcf 102.5 105.6 Chamber Pressure, psi 83.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure,psi 80.0 Volume of Solids, cm' 388.13 388.16 Eff. Consol. Stress,(Minor pr. stress, a3),psi 3.0 Volume of Voids, cm' 250.16 231.46 Change in Height, in 0.016 Void Ratio 0.64 0.60 "B" Value 0.95 % Saturation 79.3 100.0 SHEAR DATA Elapsed Time (min) Deformation (inch) Axial Load (lb) Pore Pressure,psi -Water Total Strain (%) Corrected Area (in2) Dev.Stress (4a=a -a 3) (psi) Major Principal Stress,psi , psi Eff.Stress Ratio a;/a3 P' (a',+a 3)/2 (psi) Q [(a,-a3)l2] (psi) Eff. Minor Pr. Stress a3 (psi) Total,U Change,4U Total al Eff. a', 0.0 0.000 13.6 80.0 0.0 0.00 6.32 0.0 3.0 3.0 1.00 3.0 0.0 3.0 1.0 0.010 52.9 80.8 0.8 0.17 6.33 6.2 9.2 8.4 3.80 5.3 3.1 2.2 2.0 0.020 60.1 81.2 1.2 0.34 6.34 7.3 10.3 9.1 5.14 5.4 3.7 1.8 3.1 0.031 64.3 81.5 1.5 0.51 6.35 8.0 11.0 9.4 6.44 5.5 4.0 1.5 4.1 0.041 67.4 81.8 1.8 0.68 6.36 8.4 11.4 9.7 7.78 5.5 4.2 1.2 5.1 0.051 69.6 81.9 1.9 0.85 6.37 8.8 11.8 9.9 9.10 5.5 4.4 1.1 7.1 0.071 73.1 81.9 1.9 1.19 6.40 9.3 12.3 10.4 9.57 5.7 4.6 1.1 10.2 0.102 76.4 81.8 1.8 1.70 6.43 9.8 12.8 11.0 9.10 6.1 4.9 1.2 12.2 0.122 78.5 81.7 1.7 2.04 6.45 10.1 13.1 11.4 8.59 6.4 5.0 1.3 15.3 0.153 81.5 81.5 1.5 2.55 6.48 10.5 13.5 12.0 7.94 6.7 5.2 1.5 17.3 0.173 83.3 81.4 1.4 2.90 6.51 10.7 13.7 12.3 7.58 7.0 5.4 1.6 20.4 0.204 85.8 81.2 1.2 3.41 6.54 11.0 14.0 12.8 7.10 7.3 5.5 1.8 24.5 0.245 89.0 80.9 0.9 4.09 6.59 11.5 14.5 13.5 6.58 7.8 5.7 2.1 29.6 0.296 92.3 80.6 0.6 4.94 6.65 11.8 14.8 14.2 6.03 8.3 5.9 2.4 35.7 0.357 95.3 80.3 0.3 5.96 6.72 12.2 15.2 14.8 5.54 8.8 6.1 2.7 40.8 0.408 97.6 80.3 0.3 6.81 6.78 12.4 15.4 15.1 5.59 8.9 6.2 2.7 45.9 0.459 99.7 80.2 0.2 7.66 6.84 12.6 15.6 15.3 5.56 9.0 6.3 2.8 49.9 0.499 101.4 80.1 0.1 8.34 6.89 12.7 15.7 15.7 5.36 9.3 6.4 2.9 60.1 0.601 105.7 79.8 -0.2 10.05 7.02 13.1 16.1 16.3 5.15 9.7 6.6 3.2 70.3 0.703 109.7 79.7 -0.3 11.75 7.16 13.4 16.4 16.7 5.12 10.0 6.7 3.3 80.5 0.805 113.7 79.6 -0.4 13.45 7.30 13.7 16.7 17.1 5.03 10.3 6.9 3.4 85.6 0.856 115.4 79.5 -0.5 14.31 7.37 13.8 16.8 17.3 4.95 10.4 6.9 3.5 90.0 0.900 117.2 79.5 -0.5 15.04 7.44 13.9 16.9 17.4 4.98 10.5 7.0 3.5 Values @ Failure 1.9 1.19 6.40 9.3 12.3 10.4 9.57 5.7 4.6 1.1 Failure criteria used* I 3 "Note:"1"=Max Deviator Stress;"2"=Deviator Stress @ 15% Strain;"3"=Max Eff.Stress Ratio(a',/a'3) Dnnc 1 of 7 Triaxial CU.xls [Al REV 1; 10-10-05 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 � re:.�; Phone: 770-938-8233 I Tested By EB/KP IF Fax: 770-923-8973 Date 01/14/21 Web: www.test-Ilc.com ., ' 5 HT Checked By ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # 2160-03-1 Pr. Name American Thread Sample Type Remold Sample ID 36979/B-16 Depth/Elevation 20-25.0' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION initial) (final) Height, in 6.000 5.967 Mass of Wet Sample and Tare, g 342.10 1584.90 Diameter, in 2.875 2.840 Mass of Dry Sample and Tare, g 298.30 1353.82 Height -to -Diameter Ratio 2.1 2.1 Mass of Tare, g 67.00 305.70 Area, in 6.49 6.33 Moisture, % 18.94 22.05 Volume, cm' 638.29 619.37 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 1246.60 1279.40 Mass of Dry Sample, g 1048.12 1048.29 Machine Speed, in / min 0.0100 Wet Density, pcf 121.9 129.0 Strain Rate, % / min 0.17 Dry Density, pcf 102.5 105.7 Chamber Pressure, psi 86.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure,psi 80.0 Volume of Solids, cm' 388.19 388.25 Eff. Consol. Stress,(Minor pr. stress, a3),psi 6.0 Volume of Voids, cm' 250.10 231.11 Change in Height, in 0.033 Void Ratio 0.64 0.60 "B" Value 0.95 % Saturation 79.4 100.0 SHEAR DATA Elapsed Time (min) Deformation (inch) Axial Load (lb) Pore -Water Pressure,psi Total Strain (%) Corrected Area Ore) Dev.Stress (Da=a -as)Stress, (psi) Major Principal psi Eff.Stress Ratio a',/a'3 P (a 1+a'3)/2 (psi) Q [(a-a3)l2] (psi) Eff. Minor Pr. Stress a'3 (psi) Total,U Change,4U Total al Eff. a', 0.0 0.000 22.0 80.0 0.0 0.00 6.33 0.0 6.0 6.0 1.00 6.0 0.0 6.0 1.0 0.010 64.5 81.4 1.4 0.17 6.35 6.7 12.7 11.3 2.46 8.0 3.4 4.6 2.0 0.020 69.7 82.6 2.6 0.34 6.36 7.5 13.5 10.9 3.23 7.1 3.8 3.4 3.1 0.031 72.0 83.3 3.3 0.51 6.37 7.9 13.9 10.5 3.92 6.6 3.9 2.7 4.1 0.041 73.8 83.7 3.7 0.68 6.38 8.1 14.1 10.4 4.53 6.4 4.1 2.3 5.1 0.051 75.5 83.9 3.9 0.85 6.39 8.4 14.4 10.4 5.06 6.2 4.2 2.1 7.1 0.071 78.1 84.1 4.1 1.20 6.41 8.8 14.8 10.6 5.66 6.3 4.4 1.9 10.2 0.102 80.8 84.1 4.1 1.71 6.44 9.1 15.1 11.0 5.80 6.5 4.6 1.9 12.2 0.122 83.1 84.0 4.0 2.05 6.47 9.4 15.4 11.5 5.68 6.7 4.7 2.0 15.3 0.153 85.5 83.8 3.8 2.56 6.50 9.8 15.8 11.9 5.52 7.0 4.9 2.2 17.3 0.173 87.3 83.8 3.8 2.90 6.52 10.0 16.0 12.2 5.63 7.2 5.0 2.2 20.4 0.204 90.4 83.8 3.8 3.42 6.56 10.4 16.4 12.6 5.74 7.4 5.2 2.2 24.5 0.245 94.1 83.8 3.8 4.10 6.60 10.9 16.9 13.2 5.87 7.7 5.5 2.2 29.6 0.296 99.3 83.7 3.7 4.95 6.66 11.6 17.6 13.9 5.95 8.1 5.8 2.3 35.7 0.357 104.7 83.5 3.5 5.98 6.74 12.3 18.3 14.8 5.86 8.7 6.1 2.5 40.8 0.408 108.3 83.3 3.3 6.83 6.80 12.7 18.7 15.4 5.73 9.0 6.3 2.7 45.9 0.459 112.8 83.1 3.1 7.69 6.86 13.2 19.2 16.1 5.55 9.5 6.6 2.9 49.9 0.499 115.8 82.9 2.9 8.37 6.91 13.6 19.6 16.6 5.42 9.9 6.8 3.1 60.1 0.601 122.7 82.5 2.5 10.08 7.04 14.3 20.3 17.8 5.09 10.6 7.1 3.5 70.3 0.703 128.5 82.1 2.1 11.78 7.18 14.8 20.8 18.8 4.77 11.4 7.4 3.9 80.5 0.805 133.4 81.7 1.7 13.49 7.32 15.2 21.2 19.6 4.51 11.9 7.6 4.3 85.6 0.856 136.0 81.5 1.5 14.35 7.40 15.4 21.4 19.9 4.43 12.2 7.7 4.5 90.0 0.900 138.1 81.4 1.4 15.09 7.46 15.6 21.6 20.2 4.38 12.4 7.8 4.6 Values @ Failure 3.7 4.95 6.66 11.6 17.6 13.9 5.95 8.1 5.8 2.3 Failure criteria used* 3 `Note:"1"=Max Deviator Stress;"2"=Deviator Stress @ 15% Strain;"3"=Max Eff.Stress Ratio(a',/a'3) Page 2 of 7 TriaxialICU xls [B], REV 1; 10-10-05 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 � re:.�; Phone: 770-938-8233 I Tested By EB/KP IF Fax: 770-923-8973 Date 01/12/21 Web: vvvvw.test-Ilc.com H .5 c c , T o Checked By ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # 2160-03-1 Pr. Name American Thread Sample Type Remold Sample ID 36979/B-16 Depth/Elevation 20-25.0' Location - Additional Info - SPECIMEN PROPERTIES (initial) (after consol.) WATER CONTENT DETERMINATION initial) (final) Height, in 6.000 5.947 Mass of Wet Sample and Tare, g 342.10 1569.70 Diameter, in 2.875 2.825 Mass of Dry Sample and Tare, g 298.30 1346.49 Height -to -Diameter Ratio 2.1 2.1 Mass of Tare, g 67.00 299.80 Area, in 6.49 6.27 Moisture, % 18.94 21.32 Volume, cm' 638.29 611.02 TEST DATA PRIOR TO LOADING Mass of Wet Sample, g 1244.90 1270.20 Mass of Dry Sample, g 1046.69 1046.94 Machine Speed, in / min 0.0100 Wet Density, pcf 121.8 129.8 Strain Rate, % / min 0.17 Dry Density, pcf 102.4 107.0 Chamber Pressure, psi 92.0 Specific Gravity (assumed) 2.700 2.700 Back Pressure,psi 80.0 Volume of Solids, cm' 387.66 387.76 Eff. Consol. Stress,(Minor pr. stress, a3),psi 12.0 Volume of Voids, cm' 250.63 223.26 Change in Height, in 0.053 Void Ratio 0.65 0.58 "B" Value 0.95 % Saturation 79.1 100.0 SHEAR DATA Elapsed Time (min) Deformation (inch) Axial Load (lb) Pore -Water Pressure,psi Total Strain (%) Corrected Area Ore) Dev.Stress (Da=a -a3)Stress, (psi) Major Principal psi Eff.Stress Ratio a',/a'3 P' (a 1+a'3)/2 (psi) Q [(a-a3)l2] (psi) Eff. Minor Pr. Stress a'3 (psi) Total,U Change,4U Total al Eff. a', 0.0 0.000 28.0 80.0 0.0 0.00 6.27 0.0 12.0 12.0 1.00 12.0 0.0 12.0 1.0 0.010 87.1 83.8 3.8 0.17 6.28 9.4 21.4 17.6 2.14 12.9 4.7 8.2 2.0 0.020 98.6 84.8 4.8 0.34 6.29 11.2 23.2 18.4 2.57 12.8 5.6 7.2 3.1 0.031 105.2 85.4 5.4 0.51 6.30 12.2 24.2 18.8 2.86 12.7 6.1 6.6 4.1 0.041 108.6 85.8 5.8 0.69 6.31 12.8 24.8 19.0 3.06 12.6 6.4 6.2 5.1 0.051 109.7 86.1 6.1 0.86 6.32 12.9 24.9 18.8 3.19 12.4 6.5 5.9 7.1 0.071 109.6 86.6 6.6 1.20 6.35 24.9 18.3 3.37 11.9 6.4 5.4 10.2 0.102 109.8 87.0 7.0 1.71 __I12.9 6.38 12.8 24.8 17.8 3.58 11.4 6.4 5.0 12.2 0.122 110.4 87.2 7.2 2.06 6.40 12.9 24.9 17.7 3.69 11.2 6.4 4.8 15.3 0.153 111.6 87.3 7.3 2.57 6.44 13.0 25.0 17.7 3.76 11.2 6.5 4.7 17.3 0.173 112.5 87.3 7.3 2.91 6.46 13.1 25.1 17.8 3.81 11.2 6.5 4.7 20.4 0.204 114.2 87.4 7.4 3.43 6.49 13.3 25.3 17.9 3.86 11.3 6.6 4.6 24.5 0.245 116.7 87.4 7.4 4.11 6.54 13.6 25.6 18.2 3.92 11.4 6.8 4.6 29.6 0.296 119.8 87.3 7.3 4.97 6.60 13.9 25.9 18.6 3.97 11.6 7.0 4.7 35.7 0.357 123.3 87.3 7.3 6.00 6.67 14.3 26.3 19.0 4.01 11.9 7.1 4.7 40.8 0.408 126.4 87.2 7.2 6.85 6.73 14.6 26.6 19.4 4.07 12.1 7.3 4.8 45.9 0.459 128.8 87.2 7.2 7.71 6.79 14.8 26.8 19.7 4.08 12.2 7.4 4.8 49.9 0.499 131.2 87.1 7.1 8.40 6.84 15.1 27.1 19.9 4.10 12.4 7.5 4.9 60.1 0.601 136.4 87.0 7.0 10.11 6.97 15.5 27.5 20.5 4.12 12.8 7.8 5.0 70.3 0.703 141.4 87.0 7.0 11.82 7.11 16.0 28.0 21.0 4.19 13.0 8.0 5.0 80.5 0.805 145.7 86.8 6.8 13.54 7.25 16.2 28.2 21.4 4.14 13.3 8.1 5.2 85.6 0.856 148.2 86.8 6.8 14.39 7.32 16.4 28.4 21.7 4.13 13.5 8.2 5.2 90.0 0.900 149.9 86.7 6.7 15.14 7.39 16.5 28.5 21.8 4.10 13.6 8.3 5.3 Values @ Failure 7.0 11.82 7.11 16.0 28.0 21.0 4.19 13.0 8.0 5.0 Failure criteria used* 3 `Note:"1"=Max Deviator Stress;"2"=Deviator Stress @ 15% Strain;"3"=Max Eff.Stress Ratio(a',/a'3) Page 3 of 7 Triaxial CU.xls [CJ, REV 1; 10-10-05 Client Project # Project Name Sample ID Location T.E... S.T. TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com ,ASHY] A 0 C R 4 Ll I Y L G Tested By Date Check EB/KP 01/12/21 ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Laboratory Project # Sample Type Depth/Elevation Additional Info 20-623 American Thread 36979/B-16 2160-03-1 Remold 20-25.0' Shear Stress, psi Total and Effective Mohr's Circles Y= 0.5162x + 2.287 8 12 16 Normal Stress, psi pecimen Effective Consolidation Stress, psi Deviator Stress at Failure, psi Effective Minor Principal Stress at Failure, psi Effective Major Principal Stress at Failure, psi Axial Strain at Failure, % c y = 0.2 773x + 2 .683 20 24 28 3.0 6.0 12.0 9.3 11.6 16.0 1.1 2.3 5.0 10.4 13.9 21.0 1.19 4.95 11.82 STRENGTH PARAMETERS* Total Effective 4)° 15.5 (1)'° 27.3 C, psi 2.7 C', psi 2.3 *Valid only for Received Material at Reported Densities and Moisture Contents. Please see remarks on page 6 of this report Triaxial CU.xls [Mohr's Circles], REV. 1; 10-10-05 Page 4 of 7 Phone: 770-938-8233 Fox 770'823'8873 Web: www.test-llc.com 1874 Forge Street Tucker, GA 30084 4;�:A AASHN0 Aa C P a �'��0 Tested By EB/KP ASrmm*767/AA8uTVTzv7 Standard Test Method for Consolidated u"un`in,uTnxxial Compression Test for Cohesive Soils Client Ft# 20-623 Laboratory Project # Pr. Name American Thread Sample Type Sample ID 30979/B'10 Depth/Elevation Location Additional Info Date 01/12/21 Check -450 210U-031 Remold O 4 P" ~ Q Graph 8 P', psi 12 16 16 12 4 O A REMOLDING PROPERTIES A m mCompaction mMax Dry Density mDifference from Optimum m.c 95.1 3.1 95.1 31 FAILURE SKETCH o a, psi a, degree 2.0 24.6 T -1--,S.T. TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 AABHIO Web: www.test-Ilc.com 4cL7t Tested By EB/KP Date 01/12/21 Check Client Pr. # Pr. Name Sample ID Location ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Laboratory Project # Sample Type Depth/Elevation Additional Info 20-623 American Thread 36979/B-16 2160-03-1 Remold 20-25.0' 20 16 Deviator Stress, Aa, psi Stress - Strain Graph i 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Axial Strain, % Balance ID Number Oven ID Number Deformation Indicator ID # Digital Caliper ID # Load Cell ID # Apparatus ID # REMARKS DESCRIPTION 563/700 496/610 178/349/689 370/458 347/692/815 293/693/814 Samples (Material passing #4 Sieve) were remolded to specified % compaction and moisture content of Standard Proctor values Reddish Brown Sandy Silt NOTES: 1. Method for Saturation 2. Method for determination of cross -sectional after consolidation 3. Initial specimen moisture content obtained from cuttings 4. Final specimen moisture content obtained from entire sample WET B LL PL PI Gs USCS (ASTM D2487: D2488) ML Triaxial CU.xls [Stress -Strain GRAPH], REV. 1; 10-10-05 Pagr 6 of 7 TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Tested By EB/KP Date Check 01/12/21 �— .4ASH ID Web: www.test-llc.com r ASTM D 4767 / AASHTO T 297 Standard Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils Client Pr. # 20-623 Laboratory Project # 2160-03-1 Pr. Name American Thread Sample Type Remold Sample ID 36979/B-16 Depth/Elevation 20-25.0' Location - Additional Info - 0 Pore Pressure - Strain Graph Pore Pressure, psi D — N W A Cal CA .1 C 1 i ! ! Bar L 0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Axial Strain, % Effective Stress Ratio -Strain Graph 12.00 11.00 10.00 A 0 9.00 R 8.00 ix 7.00 to to R (-in Eff. Stre 7 N W A Ul C J 0 0 0 0 O C D O O O O O C [N f—, _ v.vv 7 0 2 4 6 8 10 12 14 16 Axial Strain,% Triaxial CUxls [Stress Ratio & Pore Water Pr. -Strain GRAPH], REV. 1; 10-10-05 Page 7 of 7 TIMELY ENGINEERING SoIL. TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com AASHI❑ hG G RCG IT CO Tested By EB Date 01/07/21 Checked By Client Pr. # Pr. Name Sample ID Location 20-623 American Thread 36979/B-16 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 Bulk 20-25.0' ASTM D 4318/AASHTO T 88, T 89 Standard Test Method for Liquid Limit, Plastic Limit, and Plasticity Index of Soils (Atterberg Limits) Number of Blows Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % MOISTURE CONTENT °/ 34 33 32 31 30 29 28 LIQUID LIMIT 35 26 15 48.91 46.15 44.74 43.56 41.06 40.54 25.24 24.40 27.79 29.20 30.55 32.94 Oven ID # Balance ID # Liquid Limit Device ID # 10 Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % DESCRIPTION 20 25 30 40 NUMBER OF BLOWS PLASTIC LIMIT 34.40 35.86 32.57 33.55 24.61 23.35 22.99 22.65 NATURAL MOISTURE 847.80 723.50 304.60 29.67 Reddish Brown Sandy Silt 15/496/610 139/563 451/569 100 NOTE: MATERIAL PASSING NO. 40 SIEVE WAS USED FOR TEST LIQUID LIMIT (LL) PLASTIC LIMIT (PL) PLASTICITY INDEX (PI) LIQUIDITY INDEX (LI) USCS (ASTM D2487; D2488) ML AASHTO (M 145) 31 23 8 0.83 NA TIMELY ENGINEERINGPhone: SOIL TEST'S, LLC 1874 Forge Street Tucker, GA 770-938-8233 Fax: 770-923-8973 Web: www.test-11c.com 30084 Tested By Date Checked By n T.E. A S.T. IH 01/07/21 A A G G R C O T co Ale Client Pr. # Pr. Name Sample ID Location 20-623 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 American Thread Bulk 36979/B-16 20-25.0' - - ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311; Particle Size Analysis (Split Sieve) MOISTURE CONTENT of TOTAL Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % SAMPLE MOISTURE CONTENT of FINE MATERIAL Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, % 847.8 510.90 723.5 485.00 304.6 105.70 29.7 6.8 TOTAL Mass of wet sample before splitting & tare, g Mass of Tare, g TOTAL Mass of dry sample, g Mass of Wet Fine Material & Tare, g Mass of Tare, g Mass of Dry Fine Material, g % of Total Sample Passing Split Sieve 27420.0 190.60 0.0 0.00 21145.5 178.42 99.6 SIEVE ANALYSIS* Mass of Tare, Sieve Size 12" 3" 2.5" 2" 1.5" 1" .75" 5" .375" COARSE g MATERIAL % RETAINED % PASSING Mass of Tare, g Sieve Size #4 #10 #20 #40 #60 #100 #20o * - ASTM Defini ** - AASHTO Definitions FINE MATERIAL % PASSING (of Total) 0.0 0.00 Sample & Tare, g Cumulative Mass retained, g COBBLES 0.0 100.0 COARSE GRAVEL 0.0 100.0 COARSE SAND 2.38 98.3 0.0 100.0 MEDIUM SAND 8.81 94.7 0.0 100.0 16.25 90.5 0.0 100.0 FINE SAND 23.60 86.4 0.0 100.0 30.13 82.8 FINE GRAVEL 21.5 0.1 99.9 40.47 77.0 45.3 0.2 99.8 FINES 68.69 61.2 86.7 0.4 99.6 ions of Classification of Classification NOTE: Sieve 3/8" (9.5 mm) Sieve used for splitting sample on fine and coarse material PARTICLE -SIZE ANALYSIS' Oven ID # Balance ID# Shaker ID # REMARKS 15/496/610 % COBBLES % COARSE Gravel % FINE Gravel % COARSE Sand 0.0 % MEDIUM Sand % FINE Sand % FINES % TOTAL SAMPLE 8.3 139/142/700 0.1 25.2 555 1.6 61.2 3.6 100.0 PARTICLE -SIZE ANALYSIS"" COBBLES % COARSE Gravel (Stone) % MEDIUM Gravel (Stone) % FINE Gravel (Stone) 0.0 % COARSE Sand % FINE Sand % FINES (Silt -Clay) % TOTAL SAMPLE 8.3 0.0 25.2 0.4 61.2 4.9 100.0 DESCRIPTION USCS (ASTM D2487; Reddish Brown Sandy Silt D2488) AASHTO (M 145) Page 1 of 2 ML NA TIMELY 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 '1".. S.T. ENGINEERING Tested By IH SOIL Date 01/07/21 Web: WWW.test-Ilc.com .4 SH CI G Checked By Ale TESTS, LLC Client Pr. # Pr. Name Sample ID Location 20-623 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 American Thread Bulk 20-25.0' 36979/B-16 - - ASTM D 6913 (D 422 old version), D 1140, C 136, C 117 / AASHTO T 88, T 27, T 11, T 311 Standard Test Method for Particle -Size Analysis of Soils and Aggregates (Split Sieve) 100 Particle -Size Analysis _ VV O �c O O VOV 00 O O O .�. M N iV 2 :L.N ik ik ik ik O V O 90 • • • • � • • • • • • • • • • • • 80 70 P 60 A S 50 S I N 40 G 30 20 10 0 1000 100 10 1 0 1 0.01 0.001 Grain size in millimeters Coarse Fine Coarse Medium Fine Silt or Clay Boulders Cobbles Gravel Sand Fines Dto NA mm D30 NA mm D60 NA mm Cu NA Cc NA Project's Specific % Passing NA Page 2 of 2 Project's Specific Particle Size, mm NA TIMELY ENGINEERING SOIL TESTS, LLC 1874 Forge Street Tucker, GA 30084 Phone: 770-938-8233 Fax: 770-923-8973 Web: www.test-Ilc.com AA5H1❑ A99 RCQI TC6 Tested By Date IH 01/09/21 Checked By seer Client Pr. # Pr. Name Sample ID Location 20-623 American Thread 36979/B-16 Lab. PR. # S. Type Depth/Elev. Add. Info 2160-03-1 Bulk 20-25.0' ASTM D 698 Standard Test Method for Laboratory Compaction Characteristics of Soil Using Standard Effort (12,400 ft-Ibf/ft3 (600kN-m/m3)) Mass of Soil before sieving, g Mass of Mat. Retained on No. 4 sieve, g Mass of Mat. Retained on 3/8" sieve, g Mass of Mat. Retained on 3/4" sieve, g Material Retained on No. 4 Sieve, Material Retained on 3/8" Sieve, % Material Retained on 3/4" Sieve, % Total, % (oversized) Points Mass of Mold and Soil, g Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, Wet Density, pcf Dry Density, pcf DETERMINATION OF TEST PROCEDURE wet dry 27420.0 21145.5 86.7 86.7 0.4 0.4 TEST DATA MOISTURE CONTENT Coarse + Fine Mass of Wet Sample & Tare, g Mass of Dry Sample & Tare, g Mass of Tare, g Moisture Content, 1 2 3 4 5 5993.0 6120.0 6142.0 6130.0 500.0 499.0 540.8 506.0 462.4 450.6 491.1 446.6 179.5 130.1 183.3 124.3 13.3 15.1 16.1 18.4 115.21 123.6 101.7 107.4 125.1 107.7 124.3 105.0 Procedure Coarse 847.8 86.7 723.5 86.7 304.6 0.0 29.7 0.0 B Mold ID Number Mass of Mold, g Volume of Mold, ft3 Hammer ID Number Number of Blows per layer Number of Layers Mechanical Compactor ID Number 798 4252.4 0.0333 318 25 3 317 Method A: Material retained on No. 4 Sieve<25% Method B: Material retained on 3/8" Sieve <25% Method C: Material retained on 3/4" Sieve <30% Dry Density, pcf 110.0 108.0 Moisture vs. Dry Density • 106.0 • 104.0 102.0 100.0 100% Saturation Curves: Gs=2.6); (Gs=2.7); Gs=2.8) 13.0 14.0 15.0 16.0 17.0 18.0 19.0 20.0 Moisture Content, 21.0 22.0 23.0 REMARKS DESCRIPTION Reddish Brown Sandy Silt Maximum Dry Density, pcf Optimum Moisture Content, % 107.8 15.8 USCS (ASTM D2487; D2488) Corrected Maximum Dry Density, pcf Corrected Optimum Moisture Content, % ML AASHTO M145 NA NA NA Project Name: American Thread - Slope Stability Analysis Location: Marion, North Carolina Date: February 1, 2021 Project No. 20-623 APPENDIX D - SLOPE STABILITY PROFILES vi -40 -20 0 20 40 60 80 100 120 14 Project SLIDE - An Interactive Slope Stability Program Analysis Description Company File Name Section B-3 - 020121.slim u, N v Cii Date 2/1/2021, 8:48:29 AM 1.063 1.409 \ 1 00Ibs/ft2 m0 3 '° o` �IJ O N QI) (1111) C q)— III 11111r-4 'pi ��r lin' 2°' qi iz z 0 O -0 O oO W O l ors O O Lr) O O O O O O O O O O O O O O O O O O O O N O Lr) O N O Lr) O rl rl N N Cr) Cr) ,r' ,r' Lo O O N Lo + O O O lI I III •ddIIIII ' I 1 I I OZ176 OO176 I) 09E6 I I I I I I I I I I 09E6 I I I I I I I I I OPE6 -40 -20 0 20 40 60 80 100 120 140 Project SLIDE - An Interactive Slope Stability Program L. /1 !-- _ - — - - Analysis Description ■ Company File Name Section B-3 - 020121.slim CO CO M N v m m Now NNW Date LIDEINTERPRET 6.039 2/1/2021, 8:48:29 AM In0_0n ms/ft9 QII)Cil C gill '4 O�, ' iz O -0 O O C a O - co O O � O + O O O O O O O O O O O O O O O O O O O O O O O N O � O N O � O N O rl rl N N Cr) Cr) �' �' in in LD IliIIIIII •ilIIIII� Obbl OZb6 OOb6 08E6 09E6 ObE6 V.LVV -40 -20 0 20 40 60 80 100 120 140 Project SLIDE - An Interactive Slope Stability Program Analysis Description Company Flle Name Section B-13 - 020121.slim Ln M N m Date 2/1/2021, 9:39:06 AM CO 3 QI)IcDI gil) 1 OA ��r ' 2°' vi z iz E''' E O o -0O O O co o O Ln O + o 0 0 o 0 0 0 o o 0 0 O O O O O O O O O O O O Lf) O Ln O Lf) O Ln O Lf) O rl rl N N CO') CO') �' �' In In LD 4111111.illllll Obb6 1,.,.1111 111111111 1,. . 1 , . , . 1 , OZb6 OOb6 08E6 09E6 '1 "I" '1 ObE6 Di- M N - M II-21 P o o -40 -20 0 20 40 60 80 100 120 140 Project SLIDE - An Interactive Slope Stability Program Analysis Description Company Flle Name Section B-13 - 020121.slim Date 2/1/2021, 9:39:06 AM CO ` Woad iI- CII) III ! 4 Op III ��r ' 2°' vi 4.11...4, E z 0 O -0 O 0 O I -I O l cri O O � O + O O O O O O O O O O O O O O O O O O O O O O O N O � O N O � O N O rl rl N N Cr) (`') ,r' ,r' LO LO LD Ili II Nil lb. Obb6 OZb6 OO176 08E6 09E6 ObE6 0 — N Project SLIDE - An Interactive Slope Stability Program Analysis Description Company Flle Name Section B-15 - 020121.slim 0 0 0 O — o 0.880 -40 -20 0 20 40 60 80 M Date 2/1/2021, 10:33:59 AM N v m ii CO O` CII) 0 C Illi,4 + -gill/ - Op 0 o o o 0 0 o 0 0 0 o o 0 0 - -' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o LO O in o LO O in o LO O in o _ a O O rl rl N N Cr) Cr) �' �' in in LD - O co 4111111.illllli- -_ ��� 2°' vi Lz �_ Z 1 ottL 1 1 OZIb6 1 OObL 1 09C6 1 1 09C6 1 1 OK I. 1 1 n ° ° o -60 -40 -20 0 20 40 60 80 100 120 Project SLIDE - An Interactive Slope Stability Program Analysis Description Company Flle Name Section B-15 - 020121.slim 0 CO O l M O M N v Date 2/1/2021, 10:33:59 AM 0 CO CCII) 1111) III- 11111r-4 I`, ��� 2°' vi Lz �_ Z n 0 o -' 0 0 o Ca O (ll4111111.illllli- co o 0 LO O + o 0 0 o 0 0 0 o o 0 0 0 0 0 0 0 0 0 0 0 0 0 O Ln o LO O �n o LO O �n o rl rl N N Cr) Cr) �' �' in in 1 otti. 1 1 OZIbi. 1 OObl. 1 09Cl• 1 1 09Cl• 1 1 OK I. 1 1 CATAWBA VALLEY ENGINEERING & TESTING PO Box 747 Hickory, NC 28603 161 Lenoir Rhyne Blvd Hickory, NC 28602 828 578 9972 0 www.cvet.net NC Firm No. C-3833 SC Firm No. 5201 Geotechnical Engineering Environmental Services CMT/Special Inspections February 18, 2021 Mr. Matt Vranjes, PE Assistant Project Manager 3701 Arco Corporate Drive, Suite 400 Charlotte, North Carolina mvranjes@cecinc.com Re: Supplementary Recommendations American Thread - Slope Stability Analysis 630 American Thread Road Marion, McDowell County, North Carolina CVET Project No.: 20-623 Dear Mr. Vranjes: Catawba Valley Engineering and Testing (CVET) is providing this letter summarizing our supplementary recommendations for the project as discussed during a conference call on February 3, 2021. These supplementary recommendations are intended to provide clarification and supersede the recommendations presented in our original report dated February 1, 2021. The purpose of this letter is to discuss the three possible remedial options to increase the stability of the existing coal ash slopes. CONCLUSIONS AND RECOMMENDATIONS After discussion during the conference call, review of the site conditions encountered during the subsurface exploration, and the results from the slope stability analysis performed, we have generated the following three options to address the long-term stability of the basin slopes. Option 1: Piping the Existing Creek/Storm Water and Overbuilding Slopes The first option to increase the long term stability of the existing slopes would be to overbuild all existing slopes to a minimum inclination of 3:1 (H: V). Decreasing the inclination of these slopes greatly increase the stability and promote positive long-term performance. This option is also minimally invasive and will not require major disturbance of the in - place coal ash. This option would require the installation of a piping system along the eastern side of the site to allow for continued flow of existing creek/ storm water collection area to facilitate grade raise fill modifications. Permitting and piping of this area is recommended to be performed in American Thread CVET Project No.: 20-623 Page 12 accordance with NCDEQ guidelines. Any fill soils, as applicable, should be compacted to at least 98 percent of the maximum dry density obtained in accordance with ASTM Specification D-698, Standard Proctor Method, with a moisture content within +/- 3% of the optimum moisture content (OMC). Acceptable fill soils should be soil that has less than 5 percent organic content and a liquid limit and plasticity index less than 50 and 20, respectively. Soils with USCS group symbols of SP, SW, SM, SC, and ML are recommended for use as controlled fill, although it is important to note that silty soils are moisture sensitive and can be difficult to place with in -situ moisture contents at or above the OMC. All fill soils should be placed in horizontal loose lifts and compacted with adequately -sized equipment. Loose lift thicknesses will vary depending on the size of the compaction equipment: we recommend a maximum of 8 inches for large self-propelled compactors, 6 inches for small self- propelled compactors, and 4 inches for remote -controlled compactors and hand - operated equipment (plate tampers, wacker-packers, or jumping jacks). Vibratory smooth -drum rollers are appropriate for cohesionless/coarse-grained soils while sheepsfoot rollers are appropriate for cohesive/fine-grained soils. Option 2: Excavating Site Slopes to Decrease Inclination The second option would be to lay the existing slopes back to decrease the inclination to a minimum of 3:1 (H: V). We anticipate this option will likely be the most economical option; however approval and guidance from the NCDEQ will be required as a result of the extensive disturbance of the in -place coal ash. Option 3: Earth Retention System The third option would be to install an earth retention system to stabilize the existing slopes. We anticipate this option will likely be the most expensive option, but will reduce the disturbance of the in -place coal ash. Any earth retention system selected should be designed so the slopes have a minimum factor of safety of 1.50. This report has been prepared for the exclusive use of CEC and their agents for specific application to the referenced property, in accordance with generally accepted soils and foundation engineering practices. No warranties, expressed or implied, are intended or made. The conclusions and recommendations presented in this report are based on the specific laboratory testing, visual observations, and testing performed as part of our scope of work and do not reflect variations in subsurface conditions that may exist between test locations or in unexplored portions of the site. Site safety, excavation support related to OSHA requirements, and construction dewatering requirements are the responsibility of others, not American Thread CVET Project No.: 20-623 Page 13 CVET. In the event changes are made to the proposed construction plans, design or location of the project as described within this report, the conclusions and recommendations provided in this report shall not be considered valid unless CVET is given the opportunity to review the changes, and either verifies or modifies the conclusions and recommendations contained in this report in writing. CVET appreciates the opportunity to provide our geotechnical engineering services for this project. If you have any questions regarding the contents of this report, or if we can provide additional services for the project, please do not hesitate to contact us. Sincerely, CATAWBA VALLEY ENGINEERING AND TESTING, . P.0 y 5+1y1L 1Ltl J1S'++FF Cosy Io• •ins, Project Manager SEAL ip' 04 419 ;: ; ff.,JJt Lif, David M. LeGrand Jr., P.E. Principal Engineer NC #041419 APPENDIX B ENGINEERING DRAWINGS ereichenbach) — LP: 3/5/2021 1:09 PM P:\300-000\304-826\—CADD\Dwg\CV01 \304826—CV01—0000—COVER.dwgfC000—COVER SHEET) LS.•(3/5/2021 PROJECT TEAM OWNER COATS NORTH AMERICA 630 AMERICAN THREAD ROAD MARION, NC 28752 PH: (828-756-4111) CONTACT: JOHN MOSS CIVIL ENGINEER CIVIL & ENVIRONMENTAL CONSULTANTS, INC. 3701 ARCO CORPORATE DRIVE SUITE 400 CHARLOTTE, NC 28273 PH: (980) 237-0373 FX: (980) 237-0372 EMAIL: MVRANJES@CECINC.COM CONTACT: MATT VRANJES, P.E. SURVEYOR CIVIL & ENVIRONMENTAL CONSULTANTS, INC. 3701 ARCO CORPORATE DRIVE SUITE 400 CHARLOTTE, NC 28273 PH: (980) 237-0373 FX: (980) 237-0372 EMAIL: JPITTMAN@CECINC.COM CONTACT: JETTER PITTMAN, PLS COATS NORTH AMERICA SEVIER PLANT MARION, NORTH CAROLINA MARCH 2O21 NORTH Ov COAL ASH BASIN EVALUATION AREA VICINITY MAP BASE IMAGE FROM GOOGLE EARTH AERIAL IMAGERY DATE APRIL 26, 2019 1" = 3,000' SCALE IN FEET 0 3000 6000 DRAWING INDEX Sheet Number Sheet Title C000 COVER SHEET C001 GENERAL NOTES C100 EXISTING CONDITIONS PLAN BEFORE YOU DIG! CALL 1-800-632-4949 N.C. ONE —CALL CENTER IT'S THE LAW! REVISION RECORD DESCRIPTION w Q 0 O z co) ti N CO N Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com 1- z Q a o QI- W_ZO� -CCO � aU Q Z M W J J Q�LJ.Iix O oc���Q 1WWZOV 44(' i 64 cc— cc mwZO OCCCC2Oz ZUofic CO t� O v P7 Z ��-1C A��1j��1 0 ;4.4t. SEAL -: y 033786 COVER SHEET cc cc w DRAWN BY: 1- u- cc CHECKED BY: MARCH 2021 w 0 AS NOTED DWG SCALE: N co o PROJECT NO: 1- u- a Ir 0 APPROVED BY: DRAWING NO.: C000 GENERAL NOTES P:\300-000\304-826\ —CADD \ Dwg \ CV01 \ 304826—CV01—0001—GENERAL NOTES. dwg/C001—GENERAL NOTES/ LS.•(3/5/2021 — ereichenboch) — 1. EXISTING CONDITIONS AS DEPICTED ON THESE PLANS ARE GENERAL AND ILLUSTRATIVE IN NATURE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE SITE AND BE FAMILIAR WITH EXISTING CONDITIONS PRIOR TO BIDDING ON THIS PROJECT. IF CONDITIONS ENCOUNTERED DURING EXAMINATION ARE SIGNIFICANTLY DIFFERENT FROM THOSE SHOWN, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 2. EXISTING SITE INFORMATION / TOPOGRAPHIC SURVEY WAS PREPARED BY CIVIL & ENVIRONMENTAL CONSULTANTS, INC. ON DECEMBER 18, 2020. 3. GEOTECHNICAL REPORT WAS PREPARED BY CATAWBA VALLEY ENGINEERING AND TESTING ON FEBRUARY 1, 2021. 4. THE CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL EXISTING UTILITIES (INCLUDING THOSE LABELED PER RECORD DATA) PRIOR TO THE BEGINNING OF CONSTRUCTION OR EARTH MOVING OPERATIONS. INFORM ENGINEER OF ANY CONFLICTS DETRIMENTAL TO THE DESIGN INTENT. 5. 48 HOURS BEFORE DIGGING IS TO COMMENCE, THE CONTRACTOR SHALL NOTIFY THE FOLLOWING AGENCIES: THE NC UTILITY PROTECTION SERVICES, AND ALL OTHER AGENCIES THAT MAY HAVE UNDERGROUND UTILITIES INVOLVING THIS PROJECT AND ARE NON—MEMBERS OF NC UNDERGROUND PROTECTION, INC. 6. THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR COMPLYING WITH APPLICABLE FEDERAL, STATE AND LOCAL REQUIREMENTS, TOGETHER WITH EXERCISING PRECAUTIONS AT ALL TIMES FOR THE PROTECTION OF PERSONS (INCLUDING EMPLOYEES) AND PROPERTY. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTORS TO INITIATE, MAINTAIN AND SUPERVISE ALL SAFETY REQUIREMENTS, PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. 7. THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE OWNER AND OWNER'S REPRESENTATIVE FOR ANY AND ALL INJURIES AND/OR DAMAGES TO PERSONNEL, EQUIPMENT AND/OR EXISTING FACILITIES OCCURRING IN THE COURSE OF THE DEMOLITION AND CONSTRUCTION DESCRIBED IN THE PLANS AND SPECIFICATIONS. 8. CONTRACTOR SHALL OBTAIN A PERMIT FOR ALL CONSTRUCTION ACTIVITIES IN ACCORDANCE WITH LOCAL, STATE, & FEDERAL REGULATIONS. 9. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL CODES, OBTAIN ALL APPLICABLE PERMITS, AND PAY ALL REQUIRED FEES PRIOR TO BEGINNING WORK. 10. ANY WORK PERFORMED IN THE LOCAL OR STATE RIGHT OF WAYS SHALL BE IN ACCORDANCE WITH THE APPLICABLE LOCAL OR STATE REQUIREMENTS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN THE NECESSARY PERMITS FOR THE WORK, SCHEDULE NECESSARY INSPECTIONS, AND PROVIDE THE NECESSARY TRAFFIC CONTROL MEASURES AND DEVICES, ETC., FOR WORK PERFORMED IN THE RIGHT OF WAYS. 11. THE CONTRACTOR IS TO PERFORM ALL INSPECTIONS AS REQUIRED BY THE NCDEQ FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT AND FURNISH OWNERS REPRESENTATIVE WITH WRITTEN REPORTS. GENERAL CONTRACTOR TO CONTACT OWNERS ENVIRONMENTAL DEPARTMENT FOR ANY ADDITIONAL OWNER RELATED REQUIREMENTS. 12. CONTRACTOR SHALL IMPLEMENT ALL SOIL AND EROSION CONTROL PRACTICES REQUIRED BY NCDEQ. 13. ALL GROUND SURFACE AREAS THAT HAVE BEEN EXPOSED OR LEFT BARE AS A RESULT OF CONSTRUCTION AND ARE TO FINAL GRADE AND ARE TO REMAIN SO, SHALL BE SEEDED AND MULCHED AS SOON AS PRACTICAL IN ACCORDANCE WITH SPECIFICATIONS. IF NO SPECIFICATIONS ARE SUPPLIED, REFER TO NCDEQ EROSION CONTROL MANUAL. 14. ALL WORK PERFORMED BY THE CONTRACTOR SHALL CONFORM TO THE LATEST REGULATIONS OF THE AMERICANS WITH DISABILITIES ACT. 15. THE CONTRACTOR SHALL REFER TO OTHER PLANS WITHIN THIS CONSTRUCTION SET FOR OTHER PERTINENT INFORMATION. IT IS NOT THE ENGINEER'S INTENT THAT ANY SINGLE PLAN SHEET IN THIS SET OF DOCUMENTS FULLY DEPICT ALL WORK ASSOCIATED WITH THE PROJECT. 16. BEFORE INSTALLATION OF STORM OR SANITARY SEWER, OR OTHER UTILITY, THE CONTRACTOR SHALL VERIFY ALL CROSSINGS, BY EXCAVATION WHERE NECESSARY, AND INFORM THE OWNER AND THE ENGINEER OF ANY CONFLICTS. THE ENGINEER WILL BE HELD HARMLESS IN THE EVENT HE IS NOT NOTIFIED OF DESIGN CONFLICTS PRIOR TO CONSTRUCTION. 17. ADJUST/RECONSTRUCT ALL EXISTING CASTINGS, CLEANOUTS, ETC. WITHIN PROJECT AREA TO GRADE AS REQUIRED. 18. CONTRACTOR TO REMOVE & REPLACE PAVEMENT AS SPECIFIED. 19. SITE SIGNAGE AND STRIPING SHALL BE IN ACCORDANCE WITH THE NC MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES. 20. IF CONTRACTOR ELECTS TO ENTER PROJECT SITE AT A DIFFERENT LOCATION OTHER THAN SHOWN, COORDINATE WITH ENGINEER. THIS MAY REQUIRE ADDITIONAL E/C PERMITTING AND DRIVEWAY PERMITS. 21. REFER TO OWNER SCOPE OF WORK AND LAYOUT FOR DETAILS AND TO AVOID CONFLICTS. REVISION RECORD DESCRIPTION w 0 0 z CO if N CO 1 1 0 Li I (g J IW "0 z W Pmml Charlott 3701 Arco Corporate Drive • Suite 400 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com z a wZoz >-OCO va o z_ w J J a�LO wCC wZoC) 2Zav= as-2 c mwZO OCCCC2Oz Zoo a co 1. co O v BEFORE YOU DIG! CALL 1-800-632-4949 N.C. ONE —CALL CENTER IT'S THE LAWI :112', *31p_ ; SEAL r; x • 033786 '_t31taSt• �. GENERL NOTES cc cc w DRAWN BY: 1- L_ cc CHECKED BY: MARCH 2021 w 0 AS NOTED DWG SCALE: N co 0 PROJECT NO: 1- L_ cc 0 APPROVED BY: DRAWING NO.: C001 3 2 / --------�—_ �� \ REVISION RECORD DESCRIPTION I / ,�—� (//o—L°- 1'T�o\\\�i�\`_ LEGEND / / I / ��� /�' //—�\ //� ° ° ` ( \ \ 0 0 0 o o EXISTING FENCE /!/ — //J \ / / �/' /z/ o / / I / / I I ( \ \ /1 \ 0 100o EXISTING MAJOR CONTOURS -----goof ---- EXISTING MINOR CONTOURS NORTH / �!/ /� ,;/, , ° / / / \ / \ \ / / EXISTING CURB // ,/ / / // I / 7 7 / // // \ / l \ /—° \ 1 ° \ / I \ ---. \--�I \ \\ EXISTING BUILDING EXISTING FEMA FLOODZONE NOTES: j/ o EXISTING LIMEKILN CREEK / // rz / /l 4 /7 / ---- I K \ 7 / //�' I ^ 1 \ \ c/ //// /j���\--_� — \,, 1 ° w / //iii ^ -- �� �� I \ o �\ //// /� �/ -1-- 1 o `\ \� // \ ,,38p_ �, / / \/ EXISTING ^/ CLARIFIERS t i \ N /// 1. SEE SHEET C001 FOR GENERAL NOTES. DATE / / / , / // 77 / ��� /� = \v \\\�\\\ / / / Sy//// ///,— �\ ' / / / iii' 0 i' /% j% = \\ \ / / /' / `� /�/i ;139/ // �//'� �\ \ \ ` \\ / / // /, ///�� ��` \\` \ / / / // // ///////�/ \\ \\ \\ / // // / zz/�/ //90////// \�\\\\\\\ / / / / //i//' //1 i// �h j/ \ \�\\\ \w\ / // // // / 'y \•� / / / �/// 7/ _-// ///1/ \\ / / /,i - j /—��/// �// \ .3%\ \\\ / I Gam/� /� /�i / \\�\\\ 7 1 \ 1 /7 7 /i'� �/ / / / \ // / // /// /7,777 //� I I 11 / \ \// '/////%' \C�J I �, \\/'/ %'/ i�"/� „ Jl COAL ASH BASIN 2 I II111 777 ��� \� I , l ► / ��/ /��::;;T7' I Imo- \ \ \ �\\ o _/ ` \\\\\\\ (2) EXISTING 6" PVC — \ /' \ ` \ \\`\ I PIPES. PIPES TO BE F/LLED �— / \ \`�\\ I WITH FLOWABLE FILL AND CAPPED. / /' / \ \ w\\�Ci�. \ \ /' /' \ \\\\\,\ \ / 7 \ \ \ \ \\ \ \ ` / /' g \ \ / / / \ , A \\\ \ / / / \\\ \ / / �, \`\\�\\\\\ \ I/// // \ 7 \ \ \ -- 7 / 111 \ , `, \\\\ \\\ �-- / I \ � `\� ` / \\I \ ( 1 \\\\\\\\�\ ��_\ /— — _�/' \ III 1 1 , `\\\\\\\�___�'_/� �__/_ / / / / / / NCBELS #C-3035 Civil & Environmental Consultants, Inc. 3701 Arco Corporate Drive • Suite 400 • Charlotte, NC 28273 Ph: 980.237.0373 • Fax: 980.237.0372 www.cecinc.com �/9 ��/%/\'38 ��� / �� I CI) ),_/J `\\�\ �`�— -- \\ � _�' 52- — / // _- �=i �-._ / 6'6- LiI / 7 - //// 4--------- ///� r // \ \\\ \\ �-\\ /�/--:��/ /---%- // ��---- __ NAGREEN C350 TURF ,\\ \\ \ \ --/�—/ �-_/- /i!— // / ---- /--- REINFORCEMENT LINED \\\ \\\ \ \\ \ ,-\ -��/i%i� ` / / i%'/ /— / /// --'/ SPILLWAY FROM BASIN #1 \\\\ \\\\\\ \ \ \\ \\ \\ ;; /�/ ,^_ \;//^_�/ // ,� / \ W / \\\\\ 1 /,,,,,_//\\\\ ,,\ \\\\ \ `J // 1 /// -- / / 1 / \ \\\\\ \�\\\ I\ 1 / ,— / / / NN w Oz / I \ \\\\\ \\ / / \\\\\\\\\\\% //j-'//1\\//J ///'‘ \1\\\ \` \ \\\A\\\\\�\ � I / `—' \��_ -� // \\\ \ \ FEMA 500-YR}\\\\\�\\� FLOODPAIN / `\ \ / / \\\ `\/3,g0. -\ COATS NORTH AMERICA-SEVIER PLANT CCR BASIN EVALUATION 630 AMERICAN THREAD ROAD MARION, MCDOWELL COUNTY NORTH CAROLINA \\\ \/� °\\\\\ \�I\1\\\ \\\\ " \ \ \\ \ I _--- / / _ EX/ST/NG �/ \\\ (�' 1391 --' COAL ASH BASIN #1 BE FILLED / \ \\ AND CAPPED. •/• • \\\ \\\\ II / /i 13g2---- j /// \ \ // '� ' ,—'—'7 — t /\ \\/—_� _ 392 // _� �� �� / 0 o EXISTING \\\ w\\ /_—� / \ \\ —%'� r'�//1. 391 ' — "%� ' / /'' FACILITY •\ \�— \ �-- `/ '�/ 1 __---/���'/ /�// l BUILDING\ /��--_/ // \\ \ \ --- ----- --;-_-;--::;\�"1391' /�—' \ /i' �� l \ \\\ \\ \ I /' /�/— --- L — - �/ — )� �— \\ \\ \\\\\� / / �'/ //' ii' ��393 /'/ /i'/ \ \ \ \\\ /ii' / //' / / /ii' //'� /// /�// —// — ii �/ // • `// - /// — // // \` i//'/ /// / / /// v/ // I 139S. ii /// /// �1391� /�77//�///' i// / \ --/// _/ // / EXISTING PARKING \ `� / /// 9¢� / / /i/139 / �' —%�� \\\\\\\\\\\\\ --\\\\FEMA00-YR \ FLOODPLAIN \I\\\\\\ \\\`\, 6"PVC PIPE. P/PE TO \ \ \ \ \ c,, \ co\ \ WITH FLOWABLE FILL \ \ \ \ \ \ \\� \\ ; w \ \ \ \ \\ \ \\ / l \ \ \ \ \ \ \\ \\ \\\\\\ \ \ \\ / / � \\ \\\\\ \ �)llll I / /\ /�-->,39O \ \ \\ \\ \ \\ \\T\\\\\\\\ / \ / // I I I I I 1 1 Jill11 / 1 / / 1396-- / 12 1 / / // /// / /// / — // ---1391—/,�-�., _/j/y—///,�`t9.\�.\ // 6' / ////\\/i-- i /7/ //�/j i /�'i/��i/ I �II \ \ \111111 ll1111 / // /� / / / \I / \ / II / / AREA \ \ / /iii/ / / /// 1 // /— ��� ' .��///j�j / \ \\ iii/ / j/ / _/ _/-- / -\ \ //%// -�%-- — \// /' /�/ - j� \\\ /iiiii27 / LA i / —/jjib ///,� ii� //�/// / / —� //�— / / \ / -139/// /. —�// // \ / l\\ /�j�/ �'- /// // 96 j j �' / \ \ \ ....)//7--c-•,..-..-- --------_____,---- ....„..:1-;:....--;,----- \\ \ ..z\\\ (\) \ /%."--- .--- ,) / ---/„.------ /.... \ \ /�\\�i/// \ / A �5����� \ \ //' / ..... EXISTING STORMWATER ` %�%��/ OUTFALL AND HEADWALL i EXISTING CONDITIONS PLAN DRAWN BY: ERR CHECKED BY: DRAFT PROJECT NO: 304-826 APPROVED BY: DRAFT \\\. / BEFORE YOU DIG, CALL 1-800-632-4949 N.C. ONE -CALL DATE: MARCH 2021 DWG SCALE: AS NOTED CENTER ITS THE LAW, SCALE IN FEET 1 — — I 0 40 80 REFERENCE 07 64 ;4' SEAL r - • 033786 = DRAWING NO.: c100 1. TOPOGRAPHIC SURVEY WAS CONDUCTED ON DECEMBER 18, 2020 BY CIVIL & ENVIRONMENTAL CONSULTANTS, INC. 2. FEMA DATA DOWNLOADED FROM FEMA ON JANUARY 28, 2021 AS SHOWN ON FEMA FIRM MAP 3710170500J. r rt. NT�� ` , \��� Ill fR ��� .f '‘. 6 5 3 2 APPENDIX C SITE PHOTOS 'MI: 17/ Civil & Environmental Consultants, Inc. Page 1 of 3 SITE PHOTOS Date 03/05/2021 Outlet PVC pipe in Coal Ash Basin#1 has been temporarily capped to avoid point discharge from the basin to surface water outside of the basin. Outlet pipe to be permanently capped and filled with flowable fill. /Aroppiffr Civil & Environmental Consultants, Inc. Page 2 of 3 Date 03/05/2021 (2) Outlet PVC pipes in Coal Ash Basin #2 have been temporarily capped to avoid point discharge from the basin to surface water outside of the basin. Outlet pipes to be permanently capped and filled with flowable fill. (Picture is of the inlet side of the outlet pipes) 'MI: 17/ Civil & Environmental Consultants, Inc. Page 3 of 3 Date 03/05/2021 (2) Outlet PVC pipes in Coal Ash Basin #2 have been temporarily capped to avoid point discharge from the basin to surface water outside of the basin. Outlet pipes to be permanently capped and filled with flowable fill. (Picture is of the outlet side of the outlet pipes; temporary caps on both sides of pipe)