Loading...
HomeMy WebLinkAboutWQ0003487_Additional Information Request_20210617ROY COOPER Governor JOHN NICHOLSON Interim Secretary S. DANIEL SMITH Director CHARLES D. SHAPIRO — SENIOR DIRECTOR NOVOZYMES NORTH AMERICA, INC. 77 PERRY CHAPEL CHURCH ROAD FRANKLINTON, NORTH CAROLINA 27525 Dear Mr. Shapiro: NORTH CAROLINA Environmental Quality June 17, 2021 Subject: Application No. WQ0003487 Additional Information Request Novozymes Residuals Processing Facility and Distribution Program Distribution of Class A Residuals Franklin County Division of Water Resources' Central and Regional staff has reviewed the application package received April 1, 2021. However, additional information is required before the review may be completed. Please address the items on the attached pages no later than the close of business on July 19, 2021. Please be aware that you are responsible for meeting all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the Applicant's responsibility. In addition, any omissions made in responding to the outstanding items in Sections A through I, or failure to provide the additional information on or before the above requested date may result in your application being returned as incomplete. Please reference the subject application number when providing the requested information. All revised and/or additional documentation shall be signed, sealed and dated (where needed), with two paper copies and one electronic copy submitted to my attention at the address below. If you have any questions regarding this request, please do not hesitate to contact me at (919) 707- 3659 or erickson.saunders@ncdenr.gov. Thank you for your cooperation. Sincerely, �2GC,' 5'azzfrt eA - Erick Saunders, Engineer Division of Water Resources cc: Raleigh Regional Office, Water Quality Regional Operations Section (Electronic Copy) Charles Stahl, PE — S&ME, Inc. (Electronic Copy) Permit Application File WQ0003487 D.E NORTH CAROLINA Department of Environmental Quality North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 919.707.9000 Mr. Charles D. Shapiro June 17, 2021 Page 2 of 3 A. Distribution of Class A Residuals (FORM: DCAR 06-16): 1. Application Item. I1I.4. states that only 22 days of storage are provided at the facility, but the note states that the Division requires 30 days of storage in units separate from the treatment system. If storage below this 30-day requirement is to be suggested, the Permittee shall request to use alternative Design Criteria and Application Submittal requirements in their response to this letter in accordance with 15A NCAC 02T .0105(n) that demonstrates that the alternative will provide: (1.) Equal or better treatment of the waste; (2.) Equal or better protection of the waters of the state; and (3.) No increased potential for nuisance conditions from noise, odor, or vermin. Please provide a request meeting the above criteria, or provide a design that meets the 30 day storage requirement. B. Application Fee: 1. No comments. C. Cover Letter: 1. No comments. D. Program Information: 1. No comments. E. Detailed Plans and Specifications: 1. Page 1 in Section 230902 indicates that the high -high tank level for Transfer Valve FLF96DT-V- 01 for the new storage structure is 27', and FLF31301_U502986NEW indicates that the total height of the structure is 28'. Please note that the Division requires that all open -atmosphere treatment lagoons, ponds and storage units shall have at least two feet of freeboard. Please update the plans, specifications, and any calculations in Section F to reflect this freeboard requirement. F. Engineering Calculations: 1. In accordance with 15A NCAC 02T .1104(a)(2)(C), all new and expanding residuals treatment and storage facilities shall provide engineering calculations which include unit sizing criteria, total dynamic head and system curve analysis for each pump, and buoyancy calculations. Please provide signed and sealed calculations supporting the sizing of the proposed storage tank and pumps. G. Environmental Assessments: 1. N/A Mr. Charles D. Shapiro June 17, 2021 Page 3 of 3 H. Operation and Maintenance Plan (O&M Plan): 1. The submitted O&M Plan does not immediately provide the requirements for the plan as listed in 15A NCAC 02T .1110(a). Please provide a full O&M Plan that meets these requirements for review. I. Residuals Source Certification (FORM: RSC 06-16): 1. The Summary for FORM: RSC 06-16 lists that the current and the maximum dry tons per year from the residuals sources is staying the same at 41,000 dry tons per year (DT/yr). Please provide an approximate contribution of the new reverse osmosis waste stream generated from Permit No. NC0089621 similar to the differentiated SBM and WAS sources as listed in the Attachment A of the current permit.