HomeMy WebLinkAboutWI0400011_Report of Geothermal Well Sampling_20210616ROY COOPER
Governor
JOHN NICHOLSON
Interim Secretory
S. DANIEL SMITH
Director
Mr. Robert Risen
3057 Lori Lane
Yadkinville, North Carolina 27055
NORTH CAROLINA
Environmental Quality
June 16, 2021
SUBJECT: Laboratory Analytical Results
Geothermal Heating/Cooling Water Return Wells
Permit No. WI0400011
Yadkin County
Dear Mr. Risen:
On April 22, 2021, Jim Gonsiewski of the Division of Water Resources (DWR) collected groundwater
samples from the influent and effluent access points to your Geothermal Heating/Cooling Water Return
Wells. The samples were sent to the DWR Central Laboratory in Raleigh, NC for analysis.
The samples were analyzed for fecal coliform, bromide, chloride, fluoride, sulfate, total dissolved solids,
nitrate and nitrite, aluminum, antimony, arsenic, barium, beryllium, calcium, cadmium, chromium, cobalt,
copper, iron, lead, lithium, magnesium, manganese, molybdenum, nickel, potassium, selenium, silver,
sodium, thallium, vanadium, and zinc. Laboratory analytical results from the samples did not detect any
constituents above the State of North Carolina 2L (NC2L) groundwater standards.
We appreciate your cooperation in the collection of these samples. If you have any questions, please contact
me at (336) 776-9800 or via email at jim.gonsiewski@ncdenr.gov.
Sincerely,
CDocuSlgned by:
P a°V14i"jd
E197B66F179D45F...
James J. Gonsiewski, P.G.
Hydrogeologist
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ — WSRO
enc.: Laboratory Analytical Reports
cc: WSRO Electronic Files
Laserfiche Files
a E Q*)
OD.4 amtmkm.Mw nerdnr� .6/
North Carolina Department of Environmental Quality I Division of Water Resources
Winston-Salem Regional Office 1450 West Hanes Mill Road, Suite 300 I Winston-Salem, North Carolina 27105
336.776.9800
-
>T I_
] .
lIIT l_
•�-. a"�. f-:T � I
1 - 1 4
I J
4-
xi:.
1 tl 1 1 ❑ 1:1 ❑ 111 - I - .1111 I,
I
II 1 11 :1 1 -
I ❑ _
I
1: ii1"1 P .11 kit 1= I :1: .!: it ,1'i• .11 s[l.�y. :i::-Lr1.. I /:,: 1" .:: .1 if_ I FI_IN a -11 :.a - Itf.rl -,. I.'•
I - k...--x-rt�= :•�".: p_���-� r = .I .1:T - if f. 011 I11-;r -" =1 a:I i :x 1. ` • ..111 = - i
17,'] n=,i, },i' _ il.' I I_ = t :1: 1 7I114. T-.y1:11,f �;2ui. :^-k. p_�I•}IF _ - 1-'Ti .. 11� te.. Iz-x!r
1" T. 11 I: - r._[h / TS'� - :I--_I]I: 1 i.tj I - - - Y'.,
YI— _ I -'IF; '41:7I
➢ I: 1. G 11 I1
MI_i' f;
i 6, :..11_ ;-
1! •' "An '' I
11: ■ t .7 »::. I II
x
tt11� -
11
AC83941
Loc. Descr.:
County.
Region:
River Basin
Emergency
COC Yes/No
North Carolina Division of Water Resources Water Sciences Sect'on Laboratory Results
RISON RESIDENCE
Yadkin
Winston-Salem
YAD
Collector: J GONSIEWSKI
Report To WSRO
Collect Date: 04/22/2021
Collect Time: 10_42
Sample Depth
Visitl0
Location ID:
Priority
Sample Matrix:
Loc. Type.
Final Report
WSRO NLC
ROUTINE
GROUNDWATER
Water Supply
Sample ID:
PO Number #
Date Received:
Time Received:
Labworks Login ID
Delivery Method
Final Report Date:
Report Print Date:
AC83941
04/23/2021
08:30
TASCENZOI
NC Courier
6/11/21
06/11/2021
If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes.
CAS # Analyte Name
Sample temperature at receipt by lab
PQL
Result/
Qualifier
LAB
1.1
Units
°C
Method
Reference
Analysis
Date
Validated by
4/23/21 MSWIFT
Coliform, MF Fecal in liquid
1
MIC
1 B2,Q1
CFU/100m1
SM 9222 D-1997 4/23/21 JJURGEVICH
Coliform, MF Total in liquid
1
1 B2,Q1
CFU/100m1
SM 9222 B-1997 4/23/21 JJURGEVICH
14797-55-8 Nitrate as N in liquid
0.02
NUT
0.57
mg/Las N
EPA 353.2 REV 2 4/28/21 ALWILLIAMS
14797-65-0 Nitrite as N in liquid
0.01
0.01 U
mg/L as N
EPA 353.2 REV 2 4/23/21 ALWILLIAMS
E701177
NO2+NO3 as N in liquid
0.02
0.57
mg/L as N
EPA 353.2 REV 2 4/28/21 ALWILLIAMS
24959-67-9 Bromide
0.4
WET
0.4 U, Q2
mg/L
EPA 300.0 rev2 1
5/21/21 ALWILLIAMS
16887-00-6 Chloride
1.0
2.4 Q2
mg/L
EPA 300.0 rev2.1
5/21/21 ALWILLIAMS
16984-48-8 Fluoride
0.4
0.4 U, Q2
mg/L
EPA 300.0 rev2.1
5/21/21 ALWILLIAMS
14808-79-8 Sulfate
2.0
2.0 U, Q2
mg/L
EPA 300.0 rev2 1
5/21/21 ALWILLIAMS
pH in Liquid
6.9
pH Units
4/23/21 ALWILLIAMS
Total Dissolved Solids in liquid
12
98
mg/L
SM 2540 C-1997
4/28/21 ALWILLIAMS
7440-22-4 Ag by ICPMS
1.0
MET
1.0 U
ug/L
EPA 200 8 Rev5.4 5/6/21 JJURGEVICH
7429-90-5 Al by ICP
50
50 U
ug/L
EPA 200.7 Rev4 4 5/6/21 JJURGEVICH
7440-36-0
Antimony by ICPMS
10
10 U
ug/L
EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
7440-38-2 As by ICPMS
2.0
2.0 U
ug/L
EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
7440-38-3 Ba by ICP
10
20
ug/L
EPA 200.7 Rev4.4 5/6/21 JJURGEVICH
7440-41-7 Be by ICP
5.0
5.0 U
ug/L
EPA 200.7 Rev4 4 5/6/21 JJURGEVICH
7440-70-2 Ca by ICP
0.10
12
mg/L
EPA 200.7 Rev4 4 5/6/21 JJURGEVICH
7440-43-9 Cd by ICPMS
0.50
0.50 U
ug/L
EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
7440-48-4 Cobalt by ICP
50
50 U
ug/L
EPA 200.7 Rev4.4 5/6/21 JJURGEVICH
7440-47-3 Cr by ICPMS
5.0
5.0 U
ug/L
EPA 200 8 Rev5 4 5/6/21 JJURGEVICH
7440-50-8 Cu by ICPMS
2.0
160
ug/L
EPA 200.8 Rev5 4 5/6/21 JJURGEVICH
7439-89-6
Fe by ICP
50
50 U
ug/L
EPA 200.7 Rev4.4 5/6/21 JJURGEVICH
7440-09-7
K by ICP
0.10
1.6
mg/L
EPA 200.7 Rev4.4 5/6/21 JJURGEVICH
7439-93-2 LI ICP
25
25 U
ug/L
EPA 200.7 Rev4 4 5/6/21 JJURGEVICH
7439-95-4 Mg by ICP
0.10
4.9
mg/L
EPA 200.7 Rev4 4 5/6/21 JJURGEVICH
7439-96-5 Mn by ICP
10
10 U
ug/L
EPA 200.7 Rev4.4 5/6/21 JJURGEVICH
7439-98-7 Mo by ICPMS
10
10 U
ug/L
EPA 200 8 Rev5.4 5/6/21 JJURGEVICH
7440-23-5
Na by ICP
0.10
6.2
mg/L
EPA 200.7 Rev4 4 5/6/21 JJURGEVICH
WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908
"Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL.
Page 1 of 3
NC rD'W , Laboratory Section RsuCts/SarnpCe Comments/Qyalifier Defsnitions
Sample ID: AC83941
CAS # Analyte Name
7440-02-0 Ni by ICPMS
PQL
2.0
Result/
Qualifier
2.0 U
Method
Units Reference
ug/L EPA 200.8 Rev5.4
Analysis
Date Validated by
5/6/21 JJURGEVICH
7439-92-1
Pb by ICPMS
2.0 2.0 U uglL EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
7782-49-2 Se by ICPMS
1.0 1.0 U ug/L EPA 200.8Rev5.4 5/6/21 JJURGEVICH
7440-28-0 Thallium (TI) ICPMS
2.0
2.0 U
uglL
EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
7440-62-2 V by ICP
10
10 U
ug/L
EPA 200.7 Rev4.4 5/6/21 JJURGEVICH
7440-66-6 Zn by ICPMS
10
11
ug/L
EPA 200.8 Rev5.4
5/6/21
JJURGEVICH
Sample Comments
MIC:Fecal Coliform-B2-Counts from all filters = 0.
MIC:Fecal Coliform-Q1-Sample exceeded holding time prior to receipt at lab.
MIC:Total Coliform-B2-Counts from all filters = 0.
MIC:Total Coliform-Q1-Sample exceeded holding time prior to receipt at lab.
WET:F-Q2-estimated-sample hold time exceeded after receipt by lab due to instrum
WET:CI-Q2-estimated-sample hold time exceeded after receipt by lab due to instru
WET:Br-Q2-estimated-sample hold time exceeded after receipt by lab due to instru
WET:SO4-02-estimated-sample hold time exceeded after receipt by lab due to instr
WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908
"Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL.
Page 2 of 3
NC VI R, Laboratory Section Results/Sample Comments/Qualifier Definitions
Sample ID: AC83941
CAS # Analyte Name
PQL
Result/
Qualifier
Units
Method
Reference
Analysis
Date
Validated by
NCDEQ-WSS-Chemistry Lab Data Qualifiers
Al The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to call
B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor
B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 ml that would have been
B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle:
B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported
B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies.
B6 Coliform-Estimated Value. Blank contamination evident.
B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc
BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu.
BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value.
C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated.
G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L.
G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea:
G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L.
G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de
G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L.
G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated foi
G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for
G9 BOD-The DO depletion of the dilution water blank produced a negative value.
J1 Surrogate recovery limits have been exceeded.
J10 Unidentified peak; estimated value.
J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration
J12 The calibration verification did not meet the calibration acceptance criterion for field parameters.
J2 The reported value failed to meet the established quality control criteria for either precision or accuracy.
J3 The sample matrix interfered with the ability to make any accurate determination.
J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p
J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non-
J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate.
J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th
J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate.
J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration
M Sample and duplicate results are "out of control". The sample is non -homogenous (e.g., VOA soil). The reported value is the lower
N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library.
N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of
N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is Tess than the labo
N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo
N5 The component has been tentatively identified based on a retention time standard.
P Elevated PQL* due to matrix interference and/or sample dilution.
Q1 Holding time exceeded prior to receipt by lab.
Q2 Holding time exceeded following receipt by lab.
S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD).
U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value repo
U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate.
UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tt
✓ Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s
X1 Sample not screened for this compound.
X2 Sampled, but analysis lost or not performed -field error.
X3 Sampled, but analysis lost or not performed -lab error.
Y Elevated PQL* due to insufficient sample size.
Z1 Inability to analyze the sample.
Z2 Questions concerning data reliability.
WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908
'Not Detected" or"U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL.
Page 3 of 3
AC83942 North Carolina Division of Water Resources Water Sciences Section Laboratory Results
Loc. Descr.: RISON RESIDENCE
County: Yadkin Collector: J GONSIEWSKI VisitID
Region: Winston-Salem Report To WSRO Location ID: WSRO_NLC
River Basin YAD Collect Date: 04/22/2021 Priority ROUTINE
Emergency Collect Time: 11:08 Sample Matrix: GROUNDWATER
COC Yes/No Sample Depth Loc. Type: Water Supply
Final Report
Sample ID: AC83942
PO Number #
Date Received: 04/23/2021
Time Received: 08:30
Labworks LogintD TASCENZOI
Delivery Method NC Courier
Final Report Date: 6/11/21
Report Print Date: 06/11/2021
If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes.
Result/
CAS # Analyte Name PQL Qualifier
LAB
Sample temperature at receipt by lab 1.1
Units
oC
Method Analysis
Reference Date Validated by
4/23/21 MSWIFT
MIC
Coliform, MF Fecal in liquid 1 1 B2,Q1
CFU/100m1 SM 9222 D-1997 4/23/21 JJURGEVICH
Coliform, MF Total in liquid
1 1 B2,Q1
CFU/100m1 SM 9222 B-1997 4/23/21 JJURGEVICH
14797-55-8 Nitrate as N in liquid
NUT
0.02 0.58
mg/L as N EPA 353.2 REV 2 4/28/21 ALWILLIAMS
14797-65-0 Nitrite as N in liquid
0.01 0.01 U
mg/L as N EPA 353.2 REV 2 4/23/21 ALWILLIAMS
E701177
NO2+NO3 as N in liquid
0.02 0.58
mg/L as N EPA 353.2 REV 2 4/28/21 ALWILLIAMS
24959-67-9 Bromide
0.4
WET
0.4 U, Q2
mg/L
EPA 300.0 rev2.1 5/22/21 ALWILLIAMS
16887-00-6 Chloride
1.0 2.3 Q2
mg/L
EPA 300.0 rev2.1 5/22/21 ALWILLIAMS
16984-48-8 Fluoride
0.4 0.4 U, Q2
mg/L
EPA 300.0 rev2.1 5/22/21 ALWILLIAMS
14808-79-8 Sulfate
2.0 2.0 U, Q2
mg/L
EPA 300.0 rev2.1
5/22/21 ALWILLIAMS
pH in Liquid 6.8
pH Units
4/23/21 ALWILLIAMS
Total Dissolved Solids in liquid 12 100 mg/L SM 2540 C-1997 4/28/21 ALWILLIAMS
7440-22-4 Ag by ICPMS
MET
1.0 1.0 U ug/L EPA 200.8 Rev5 4 5/6/21 JJURGEVICH
7429-90-5 Al by ICP 50 50 U
ug/L
EPA 200.7 Rev4.4 5/6/21 JJURGEVICH
7440-36-0 Antimony by ICPMS 10 10 U ug/L EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
7440-38-2 As by ICPMS
2.0 2.0 U ug/L
EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
7440-38-3 Ba by ICP 10 20
ug/L
EPA 200.7 Rev4.4 5/6/21 JJURGEVICH
7440-41-7 Be by ICP
5.0 5.0 U ug/L
EPA 200.7 Rev4.4 5/6/21 JJURGEVICH
7440-70-2 Ca by I C P
0.10 12
mg/L
EPA 200.7 Rev4 4 5/6/21 JJURGEVICH
7440-43-9 Cd by ICPMS
0.50 0.50 U ug/L EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
7440-48-4 Cobalt by ICP
50 50 U ug/L
EPA 200.7 Rev4.4 5/6/21 JJURGEVICH
7440-47-3 Cr by ICPMS
5.0 5.0 U ug/L EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
7440-50-8 Cu by ICPMS
2.0 22
ug/L
EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
7439-89-6
Fe by ICP
50 50 U
ug/L
EPA200.7 Rev4.4 5/6/21 JJURGEVICH
7440-09-7 K by ICP
0.10 1.5
mg/L
EPA200.7 Rev4.4 5/6/21 JJURGEVICH
7439-93-2 Li ICP 25 25 U ug/L
EPA200.7 Rev4.4 5/6/21 JJURGEVICH
7439-95-4 Mg by ICP
0.10 4.8
mg/L
EPA 200.7 Rev4 4 5/6/21 JJURGEVICH
7439-96-5 Mn by ICP
10 10 U ug/L EPA200.7 Rev4 4 5/6/21 JJURGEVICH
7439-98-7 MO by ICPMS
10 10 U ug/L EPA 200.8Rev5 .4 5/6/21 JJURGEVICH
7440-23-5 Na by ICP
0.10
6.1 mg/L
EPA200.7 Rev4.4 5/6/21 JJURGEVICH
WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908
"Not Detected" or "U'' does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL
Page 1 of 3
NC 1DIA, Ga6oratorySection 1�su(ts/Sampee Comments/QuaCfrer(Definitions
Sample ID: AC83942
CAS #
7440-02-0
Analyte Name
Ni by ICPMS
PQL
2.0
Result)
Qualifier
2.0 U
Units
ug/L
Method
Reference
EPA 200.8 Rev5.4
Analysis
Date Validated by
5/6/21 JJURGEVICH
7439-92-1 Pb by ICPMS
2.0
2.0 U
ug/L
EPA200.8 Rev5.4 5/6/21 JJURGEVICH
7782-49-2 Se by ICPMS
1.0 1.0 U ug/L EPA200.8 Rev5.4 5/6/21 JJURGEVICH
7440-28-0 Thallium (TI) ICPMS
2.0 2.0 U ug/L EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
7440-62-2 V by ICP
10
10 U
ug/L
EPA 200.7 Rev4.4 5/6/21 JJURGEVICH
7440-66-6 Zn by ICPMS
10
10 U
ug/L
EPA 200.8 Rev5.4 5/6/21 JJURGEVICH
Sample Comments
MIC:Fecal Coliform-B2-Counts from all filters = 0.
MIC:Fecal Coliform-Q1-Sample exceeded holding time prior to receipt at lab.
MIC:Total Coliform-B2-Counts from all filters = 0.
MIC:Total Coliform-Q1-Sample exceeded holding time prior to receipt at lab.
WET:F-Q2-estimated-sample hold time exceeded after receipt by lab due to instrum
WET:CI-Q2-estimated-sample hold time exceeded after receipt by lab due to instru
WET:Br-Q2-estimated-sample hold time exceeded after receipt by lab due to instru
WET:SO4-02-estimated-sample hold time exceeded after receipt by lab due to instr
WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908
"Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL.
Page 2 of 3
NC (D`GL R, Laboratory Section Rsu(ts/Sample Comments/Qua( r'Definitions
Sample ID: AC83942
CAS # Analyte Name
PQL
Result/
Qualifier
Units
Method
Reference
Analysis
Date Validated by
NCDEQ-WSS-Chemistry Lab Data Qualifiers
Al The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to cal
B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor
B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 ml that would have been
B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smaller
B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported
B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies.
B6 Coliform-Estimated Value. Blank contamination evident.
B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc
BB1 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu
BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value.
C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated.
G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L.
G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea:
G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L.
G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de
G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L.
G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated foi
G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for
G9 BOD-The DO depletion of the dilution water blank produced a negative value.
J1 Surrogate recovery limits have been exceeded.
J10 Unidentified peak; estimated value.
J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration
J12 The calibration verification did not meet the calibration acceptance criterion for field parameters.
J2 The reported value failed to meet the established quality control criteria for either precision or accuracy.
J3 The sample matrix interfered with the ability to make any accurate determination.
J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p
J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non-
J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate.
J7 This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th
J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate.
J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration
M Sample and duplicate results are "out of control". The sample is non -homogenous (e.g., VOA soil). The reported value is the lower
N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library.
N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of
N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo
N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo
N5 The component has been tentatively identified based on a retention time standard.
P Elevated PQL* due to matrix interference and/or sample dilution.
Q1 Holding time exceeded prior to receipt by lab.
Q2 Holding time exceeded following receipt by lab.
S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD).
U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit`. The number value repo
U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate.
UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tt
✓ Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s
X1 Sample not screened for this compound.
X2 Sampled, but analysis lost or not performed -field error.
X3 Sampled, but analysis lost or not performed -lab error.
Y Elevated PQL* due to insufficient sample size.
Z1 Inability to analyze the sample.
Z2 Questions concerning data reliability.
WSS Chemistry Laboratory» 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908
"Not Detected" or"U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL.
Page 3 of 3