Loading...
HomeMy WebLinkAboutNC0028916_Pretreatment Inspection_20050209NCDENR North Carolina Department of Environment and Natural Resources Michael F. Easley, Governor February 9, 2005 Roy Maness, Mayor Town of Troy 444 North Main Street Troy, North Carolina SUBJECT: Pretreatment Compliance Inspection Town of Troy WWTP NPDES Permit. No. NC0028916 Montgomery County William G. Ross Jr., Secretary Alan W. Klimek, P.E.; Director Coleen H. Sullins, Deputy Director Division of Water Quality Dear Mayor Maness: Enclosed you will find a copy of the Pretreatment Compliance Inspection Report for the inspection conducted on , January 26, 2005 in which I met with Gray Walls (Public Works Director) and Linda Walls (Pretreatment Coordinator). The report indicates that Troy WWTP continues to meet the pretreatment requirements as outlined in 15A NCAC 2H .09.04 (b) for Modified Pretreatment- Programs. You are commended for your continued success in maintaining your program. The report is self-explanatory and contains observations, requirements and recommendations. If you or your staff have any questions or require clarification, please do nothesitate to contact me at (910) 486-1541 or Deborah Gore at (919) 733-5083, extension 593. Sincerely, Dale Lopez Environmental Specialist Enclosures: Pretreatment Compliance Inspection Report Pretreatment Review of Long Term Monitoring Plan (June a 16, 2004 letter) cc: Gray Walls, P.E., Town of Troy Public Works Director Deborah Gore, PERCS - Pretreatment Unit 225 Green Street — Suite 714, Fayetteville, North Carolina 28301-5043 Phone: 910-486-1541 \ FAX: 910-.486-0707 \ Internet: www:enr.state.nc.us/ENR/ An Equal opportunity./ Affirmative Action Employer - 50 Recycled 110 % Post Consumer Paper Northarolina aturalli United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance InspeCtton Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98' Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES - yr/mo/day Inspection 1 LJ 2 II] 3 I NC0028916 111 121 05/01/26 117 Type Inspector Fac Type 18 U 1912] 20. U III I.IIIIIIIIII166 Remarks 211 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---- —Reserved-------__-- 67 I 2.0 169 70 el 71 U 72 LJ 731 1 174 751 1-1 I 1 1 1 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Troy WWTP 650 Glen Rd Troy NC 27371 Entry Time/Date 11:00 AM 05/01/26, :. Permit Effective Date 04/08/01 Exit Time/Date. 02:00PM 05/01/26 Permit Expiration Date 09/06/30 Name(s) of Onsite Representative(s)lTitles(s)/Phone and Fax Number(s) /I/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number E. Gray Walls,444 N Main St Troy NC 27371//910-572-7841/9105723663Contacted No Section C: Areas Evaluated During Inspection (Check only,those areas evaluated) Pretreatment . Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) . Name(s) and ature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Dat Dale Lopezfa, FRO WQ//910-486-1541 Ext,712J pZ 5 65 Signature of Management Q A eviewer Agency/Office/Phone and Fax Numbers Date .rl,649./7/.S EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. NPDES NC0028916 111 121 yr/mo/day 05/01/26 Inspection Type 117 18 U 1 Section D: Summaryof Finding/Comments (Attach additional sheets of narrative and checklists as necessary) • This facility has a conscientiously run program. Requirement:- Please perform the STMP as according to the June 16, 2004 from DWQ- Pretreatment Unit, implementing the STMP during the 3rd quarter of 2007 through the 3rd quarter of 2008. NORTH CAROLINA DIVISION OF WATER QUALITY PRETREATMENT COMPLIANCE INSPECTION (PCI) REPORT FAYETTEVILLE REGIONAL OFFICE BACKGROUND INFORMATION 1. Control Authority (POTW) Name: Town of Troy 2. Control Authority Representative: Gray Walls, P.E./Linda Walls 3. Title(s): Public Works Director/Pretreatment Coordinator 4. Last Inspection Date: June 8, 2004 Inspection Type (Circle One): pi Audit 5. Has Program Completed All Requirements from the Previous Inspection or Program Info Sheet(s)? 6. Is POTW under an Order That Includes Pretreatment Conditions? Order Type And Number: Are Milestone Dates Being Met?Yes / No / PCS CODING Trans.Code N1 Program NPDES Number MM/DD/YY 1 NI CIO 10 12 18 19 11 16 J O1 /26 /05 (DTIA) Inspec.Type IILI (TYPI) IN/AI Inspector (INSP) `Yes /No Yes / No Fac.Type (FACC) 7. Current Number of Significant Industrial Users (SIUs)? 2 SIUS 8. Current Number of Categorical Industrial Users (ClUs)? 0 CIUS 9. Number of SIUs Not Inspected by POTW in the Last Calendar Year? 0 10. Number of SIUs Not Sampled by POTW in the Last Calendar Year? 0 11. Enter the Higher Number of 9 or 10. 0 NOIN 12. Number of SIUs With No IUP or With an Expired IUP? 0 NOCM 13. Number of SIUs In SNC for Either Reporting or Limits Violations During Either of the Last 2 Semi -Annual Periods (Total Number of SIUs in SNC). 0 PSNC 14. Number of SIUs in SNC for Reporting During Either of the Last 2 Semi -Annual Periods. 0 MSNC 15. Number of SIUs in SNC for Limits Violations During Either of the Last 2 Semi -Annual Periods? 0 SNPS 16. Number of SIUs in SNC for Both Reporting and Limits Violations During Either of the Last 2 Semi -Annual Periods? 0 POTW INTERVIEW 17. Since the Last PCI, has the POTW had any NPDES Limits Violations? If Yes, What are the parameters and how are these problems being addressed? 18. Since the Last PCI, has the POTW had any Problems Related to an Industrial Discharge (Interference, Pass -Through, Blockage, Citizens' Complaints, Increased Sludge Production, Etc.)? If Yes, How Are These Problems Being Addressed? YES NO YES NO 19. Which Industries have been in SNC during either of the Last 2 Semi - Annual Periods? Have any Industries in SNC (During Either of the Last 2 Semi -Annual Periods) not been Published for Public Notice? (May refer to PAR if Excessive SIUs in SNC) SNC for Limits: 0 SNC for Reporting: 0 Not Published: 0 20. Which Industries are on Compliance Schedules or Orders? For all SIUs on an Order, Has a Signed copy of the Order been sent to the Division? 21. Are any Permits or Civil Penalties Currently Under Adjudication? If Yes, Which Ones? None YES I10 PRETREATMENT PROGRAM ELEMENTS REVIEW - Please review POTW files and complete the following: Program Element Date of Last Approval Date Next Due, If Applicable Headwork Analysis (HWA) 06/04/04 01/31/09 Industrial Waste Survey (IWS) 02/02/05 12/31/09 Sewer Use Ordinance (SUO) 02/02/05 01/31/05 Enforcement Response Plan (ERP) 11/24/92 Long Term Monitoring Plan (STMP) 06/16/04 22. Is the STMP Monitoring Being Conducted at Appropriate Locations and Frequencies? 23. Should any Pollutants of Concern be Eliminated From or Added to the STMP? If Yes, which ones? Eliminated: Added: 24. Are Correct Detection Levels being used for all STMP Monitoring? Yes / No Yes / Yes fr o / No 25. Is the STMP Data Maintained in a Table or Equivalent? JYes / No Is the Table Adequate? es /No VIEW 26. User Name 1. Candor Hosiery 2. Capel 3. 27. IUP Number 0007 0002 28. Does File Contain Current Permit? a. Yes / No IYesJNo 29. Permit Expiration Date? 01/01/09 01/01/09 30. Categorical Standard Applied (I.E. 40 CFR 413, Etc.) or N/A N/A N/A .. 31. Does the File Contain Permit Application Completed Within One Year Prior to Permit Issue Date? Yes / No O o 09/03/03 08/18/03 32. Does the File Contain an Inspection Completed Within Last Calendar Year? [Yes / No Elo 08/13/04 07/18/04 33. a. Does File Contain A Slug Control Plan? b. If No, is One Needed? (See Inspection Form from POTW) a. Yes b. Yes / iill / Nol a. Yes/No b. Yes/f . 34. For 40 CFR 413 And 433 TTO Certifiers, Does The File Contain A Toxic Organic Management Plan (TOMP)? Yes/No N/A Yes / No IN/AI 35. a. Does the File Contain Original Permit Review Letter from the Division? b. All Issues Resolved? EM 06/04/04 b. Yes o a. / No 06/04/04 b.Yes / No N/A 36. During the Most Recent Semi -Annual Period, Did the POTW Complete its Sampling as Required by IUP? 'Yes / No B o 37. Does File Contain POTW Sampling Chain -Of -Custody's? Yes / No E o Located at the POTW 38. During the Most Recent Semi -Annual Period, Did the SIU Complete Yes / No N/A E o N/A its Sampling as Required By IUP? POTW does all of the sampling 39. Does Sampling Indicate Flow or Production? Yes / No N/A fres/No 40 During the Most Recent Semi -Annual Period, Did the POTW Identify All Non -Compliance from Both POTW and SIU Sampling? 'Yes / No E212o 41. a. Was the POTW Notified by SIU (Within 24 Hours) of All Self- Monitoring Violations b. Did Industry Resample Within 30 Days? a.Yes / No/ IN/AI a.Yes / No/ N/A b.Yes / No/ b.Yes / No/ IN/A 1l/A 42. Was the SIU Promptly Notified of any Violations (Per ERP)? IYesl / No N/A Yes/No N/A 43. During the Most Recent Semi -Annual Period, Was the SIU in SNC? Yes / Ilo Yes/® 44. During the Most Recent Semi -Annual Period, Was Enforcement Taken as Specified in the POTWs ERP? Yes /No/ II/AI Yes/No IN/A 45. Does the File Contain Penalty Assessment Notices? Yes / No N/A] Yes/No N/A 46. Does the File Contain Proof of Penalty Collection? Yes / No N/A] Yes/No IN/AJ 47. a. Does the File Contain any Current Enforcement orders? b. Is SIU in Compliance with Order? a.Yes / No rN/A b.Yes / No Yes/NoIN/AI N/A 48. Did the POTW Representative Have Difficulty in Obtaining any of this Requested Information for You? Yes / No Yes/ if FILE REVIEW COMMENTS PCI Comments: Conscientiously run program.. Requirements: Please perform the STMP as according to the June 16, 2004 letter (enclosed with this report), implementing the STMP during the 3rd quarter of 2007 through the 3rd quarter of 2008. Recommendation: None Requirements from the 06/08/04 inspection report: SUO --- Due to regulatory changes, the maximum fine in the SUO is now $25,000. Guidance for making this change will be available on the Pretreatment web site within the next 4 weeks. Do not make this change without consulting the guidance. If you do not have intemet access, call the Pretreatment Unit for hard copy. Submit the updated SUO to the Pretreatment Unit by January 31, 2005. COMPLETE The Town of Troy is a Modified Program and as such is only required to conduct a Short Term Monitoring Plan (STMP) for development of the site specific HWA. Troy has voluntarily been conducting Long Term Monitoring. As discussed at the inspection, Troy wishes to reduce the monitoring frequency to 1/ qtr for 4 consecutive quarters the year prior to the HWA. A review of the Plan submitted in January will be sent under separate cover to address this change. Please note that EPA Method 1631 for mercury must be used for effluent mercury sample analysis. Note the due date for the Industrial Waste Survey — 9/30/2004. Recommendation from the 06/08/04 inspection report: COMPLETE Pretreatment records starting before 1999 may be discarded at your discretion. NOD: YES NOV: YES QNCR: YES NO NO NO POTW Rating: Satisfactory 1 Marginal Unsatisfactory PCI COMPLETED BY: Dale Lopez, Env. Specialist Date:02/09/05 Name and Signature of Reviewer �((}B���e�li1/1neda Henson Agency/Office/Telephone Date NCDENR/Fayetteville/(910) 486-1541 a - 7 - D s INDUSTRY INSPECTION CODING: No Industrial Inspection was conducted during the PCI Inspection Trans.Code Main Program Permit Number MM/DD/YY Inspec.Type Inspector Fac.Type lv1 1111111 I11 1.Industry Inspected: 2.Industry Address: 3.Type of Industry/Product: 4. Industry Contact: Phone: Fax: LaJ 12( (DTIA) (TYPI) (INSP) (FACC) 5.Does the POTW use The Division Model Inspection Form or Equivalent? 6.Did the POTW Contact Conduct the Following Parts of the Industrial Inspection Thoroughly? Comments: A. Initial Interview B Plant Tour C. Pretreatment Tour D. Sampling Review E. Exit Interview Industrial Inspection Comments: Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Coleen H. Sullins, Deputy Director Division of Water Quality June 16, 2004 GRAY WALLS DIRECTOR OF PUBLIC WORKS TOWN OF TROY 444 NORTH MAIN STREET TROY NC 27371 Subject: Pretreatment Review of Long Term Monitoring Plan Town of Troy Montgomery County NPDES Number: NC0028916 Dear Mr. Walls: The Pretreatment Unit of the Division of Water Quality has reviewed the Long Term Monitoring Plan (LTMP) submitted by the Town of Troy. This LTMP was received by the Division on January 6, 2004. Review of the LTMP was delayed due to some anticipated changesto the Pretreatment Program that did not occur. As discussed at the Pretreatment Compliance Inspection conducted on June 8, the Town of Troy is a Modified program and as such is required to perform Short Term Monitoring. Troy has voluntarily been performing Long Term Monitoring and now wishes to decrease the monitoring frequency. The sampling sites, pollutants of concern and detection requirements remain unchanged, except for mercury (see # 3 below). Attached are corrected pages to convert the LTMP to a STMP. The changes are as follows. 1. On page 2, the "First Year" and "Thereafter" columns are crossed off. 2. Also on page 2, under the "1 Year Before HWA" column the frequencies for influent and effluent are quarterly on a workday. The frequency for SIUs is once for all POCs. 3. On page 3, the mercury method required for the effluent samples is specified. The next HWA is due 1/31/2009, unless circumstances warrant an earlier revision. Therefore, the STMP must be implemented during the 3`d quarter of 2007 through the 3rd quarter of 2008. This will allow at least 4 months to complete the HWA. Thank you for your continued cooperation with the Pretreatment Program. If you have any questions or comments, please contact Deborah Gore at (919) 733-5083 ext. 593 [email: deborah.gore@ncmail.net]. Sincerely, Alan W. Klimek Enclosure: Corrected page 2 & 3 of STMP dg/troySTMP.01 cc: Central Files Deborah Gore, Pretreatment Unit, w/enclosure Dale Lopez, FRO, w/enclosure NC—DENR, DWQ, PRETREATMENT UNIT 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Wehsite: http://h2o.enr.state.nc.us/Pretreat/index.html Telephone: 919-733-5083 Fax: 919-715-2941 ©'A An Equal Opportunity Affirmative Action Employer NCDENR 50% recycled/10% post -consumer paper Short -bong Term Monitoring Plan Activated Sludge / Aerobic Digester with Land Application of Biosolids F. Sampling Frequency Sampling Point First Year Thereafter 1 Year Before HWA 1- Influent Monthly on a Workday and per NPDES requirement '4 uarterly on a Workday and per NPDES Requiremen Mcrfthly on a Workday and per NPDES requirement. 2- Effluent Monthly on a Workday and per NPDES requireme I Quarterly o' a Workday , d per NP D ES Req ' , - ment Moptbly on a ��,c Workday and ► per NPDES requirement 3- Activated Sludge Basin Once per : months a . b) One; per six Mo % I (grab) Once per six months (grab) 4- Sludge to Disposal Per S dge Pe uu ' and 503 regul "ons (1/yr) ' er Sludge P - rmit and 503 gulations (1/yr) Per Sludge Permit and 503 regulations{44yr)- Per SIU Permit (Reco nded for all .O.C.'s once er year) SIU's 0002 & 0007 Pe SIU Permit 1' ecommended for all P.O.C.'s once per year) Per SIU Permit (Recommended for all P.O.C.'s once per year) l G. Sampling Plan P.O.C. Pt. 1 Pt. 2 Pt. 3 Pt. 4 As x x x X Cd x x x X Cr x x x X Cu x x x x Pb x x x x Hg x x x x Mo x x x x Ni x x x x Se x x x x Zn x x x x Cn x x x x Ag x x x x NH3 x x Chloride x x Flow x x % solids x BOD x x TSS x x Tot. N x x Tot. P x x 2 Short 4g Term Monitoring Plan Activated Sludge / Aerobic Digester with Land Application of Biosolids I. Detection Level and Sampling Method P.O.C. Detection Level (ugn) Sample Method As 10 24 hr Composite 24 hr Composite Cd 2 Cr 5 24 hr Composite Cu 2 24 hr Composite Pb : 10. 24 hr Composite -* Hg .2 24 hr Composite Mo 5 24 hr Composite Ni 10 24 hr Composite Se 10 24 hr Composite Zn 10 24 hr.Composite BOD 2 mg/1 24 hr.Composite TSS 2 mg/1 24 lir Composite 24 hr Composite Tot. N .5 mg/1 Tot. P 50 24 hr Composite : Grab. CN . 5 Ag 5 24 hr Composite NH3 .1 mg/1 24 hr Composite Chloride : 1 mg/1 24 hr Composite Sludge to Disposal samples and Septage samples will be grab. Volatile P.O.C.'s shall be grab samples. Sampling, preservation, and analytical method must be from 40 CFR 136. Generally, Graphite Furnace Determinations are required to attain the desired detection level for the metals. y ` a "ram' 3