Loading...
HomeMy WebLinkAboutNC0028916_Lab Certification Inspection_20050304Michael F. Easley, Governor r Oho WArFRQG March 4, 2005 5350 Mr. Joseph Shields Town of Troy WWTP 650 Glen Rd. Troy, NC 27371- SUBJECT: Laboratory Certification Maintenance Inspection William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality MAR -12005 Wo Dear Mr. Shields: Enclosed is a report for the inspection performed on February 24, 2005 by Ms. Tonja Springer. No deficiencies or lettered comments and/or recommendations are cited in this report, a response is not required. We appreciate the fine job you and your staff are doing. As a certification requirement, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by email, or if you have questions or need additional information please contact us at 919-733- 3908. Sincerely, James W. Meyer Laboratory Section Enclosure cc: Tonja Springer Fayetteville Regional Office ye/L Laboratory Section 1623 Mail Service Center; Raleigh, NC 27699-1623 4405 Reedy Creek Road; Raleigh, NC 27607 Phone (919) 733-3908 / FAX (919) 733-2496 / Internet: www.dwglab,org NorthCarolina Natural!" An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper On -Site Inspection Report LABORATORY NAME: Town of Troy ADDRESS: 650 Glen Road Troy, NC 27371 CERTIFICATE NO: #5350 DATE OF INSPECTION: February 24, 2005 TYPE OF INSPECTION: Field Certification Inspection EVALUATOR: Ms. Tonja Springer LOCAL PERSON CONTACTED: Mr. Joseph Shields I. INTRODUCTION: This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. II. GENERAL COMMENTS: The inspection consisted of reviewing data for NPDES #NC0028916. The staff is congratulated for doing an excellent job of implementing the laboratory certification program. Very good bench sheets and forms are used. The laboratory is of adequate size and well equipped. All equipment is well maintained. Records are well kept and the data appeared accurate. Comment: For all benchsheets, it is recommended that the lab indicate which edition of the method is being referenced. This will aid the analysts, when method changes are promulgated by EPA, to maintain adequate documentation of their data. III. DEFICIENCIES, REQUIREMENTS, COMMENTS AND RECOMMENDATIONS,: Total Residual Chlorine: Comment: The facility has a UV system and only keeps the chlorine as a backup. An annual verification curve is analyzed by Meritech. Comment: As a reminder, the gel standards should be checked when the annual verification curve is analyzed. Record and document that reading. That reading will be assigned as the true value for the gel standard until the next time the annual calibration verification is done. It is recommended that the true value be documented on the gel standard box and the benchsheet. The gel standards can be used passed the expiration date as long as the daily check meets the + 10% criteria and the gels show no sign of deterioration. IV. PAPER TRAIL INVESTIGATION: A paper trail was conducted at this facility. This consisted of comparing laboratory bench data with DMR reports. There were no transcription errors detected. V. CONCLUSIONS: No deficiencies were found during the inspection. No response is required. Report prepared by: Tonja Springer Date: February 25, 2005