Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0032111_Regional Office Historical File Pre 2018
Michael F. Easley, Governor William G. Ross Jr, Secretary North Carolina Department of Environment and Natural Resources (olten :Sullins, Director Division of Water Quail.. August 31, 2007 Mr. Barry Webb, City Manager City of Belmont PO Box 431 Belmont, NC 28012 Subject. Permit No. WQ0032111 Abbington Subdivision City of Belmont Wastewater Collection System Extension Gaston County, North Carolina Dear Mr, Webb, In accordance with your application received on August 21, 2007, we are forwarding herewith Permit No. WQ0032111, dated August 31, 2007, to the City of Belmont for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T ,0403 or any individual system -wide collection system permit issued to the Permittee, Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T, 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable: 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application, It shall be the Perrnittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215,6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, Moores.vtlic Regional Office 610 East Center Ave., Suite 301. 111)oresville, NC 2.8115 Imernet wwwitornwaterquality,org Customer Service, 1-877-623-6748 An .Equal Opportunity/Affirmative Action Employer —5,0% Recyclec1110% Post Consumer Paper Phone, (704) 663-1699 Fax: (704) 663-6040 One NhCaro1ina Natteigy Mr, Webb Page 2 August 31, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Belmont for the construction and operation of approximately 3,030 linear feet of fl- inch gravity sewer and the discharge of 18,320 gallons per day of collected domestic wastewater into the City of Belmont existing sewerage system, pursuant to the application received August 21, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable, the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Belmont WWTP (NPDES No, NC0021181) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina. General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714, Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, Coleen H. Sullins cc: Collections System Permit Files Douglas Dowell, Dowell & Company, PC Surface Water Protection Central Files Tom Asenzo, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit: 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L ,0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintainedc. , An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4, This permit shall not be transferable, In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for he life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 27; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C, 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities, 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B ,0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500, 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 7 Voice trail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence This report shall outline the actions taken or proposed to ensure that the problem does not recur, Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control Permit issued this the 31 day of August, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION ibr Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032111 1 Permit No r T��ck��nqineehnq����rtifqcati{)M August31.2U07 QwnenA&&rTPfNC]CS PE Barry Webb, City Manager Douglas Dowell City of Belmont Dowell & Company, PC POBox 431 POBox 35O4 Belmont, NC28O12 Mooresville, NC 28117 Complete and submit this form to the permit issuing regional office with the following: v One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension w Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted aspart ofthis project 0 Changes bothe project shou|dbeo|ear|yidentifiedun1hereconddrawinSaorinwritteosummaryhmrm.Pernnit modifications are required for any ohanOearesulting innon-compliance with this permit, regulations or minimum des.ign criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received bythe Division. Therefore, itimhighly recommended that this certification be sent in w manner that provides proof mfreceipt by the Division. ENGINEER'S CERTIFICATION L Partial F Final i .asaduly registered Professional Engineer inthe State cfNorth Carolina, having been authorized to observe ([— periodically, Fl weekly, [:1 full time) the construction ofAbbingtoo Subdivision, a Gaston County project h»rthePermittee.herebystate1ha\.tothebesrofmyabi|ihoe.duecare and diligence was used inthe observation of the construction such that the construction was observed to be built within substantial compliance of this permit 15A NCAC 2T� the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12. 1996 as applicable: the Division's Minimum Design Ch\ehe for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1. 2080 as applicable,, and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TOTHE FOLLOWING ADDRESS MQORESV0LLEREGIONAL OFFICE SURFACE WATER PROTECTION 610EAST CENTER AVENUE, SUITE 3Di MHOORESV|LLEy4C 28115 The Permittee is responsible for tracking all partial certifications up until a final certification ioreceived, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, ACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! 1. Owner: la. City of Belmont Full Legal Name (company, municipality, HOA, utility, etc. z 1 b. Mr. Barry Webb - City Manager O Signing Official Name and Title (Please review 5A NCAC 2H .0206(b) for authorized signing officials!) Application Number: (to be completed by DWQ) 093 2, I - lc, The legal entity who will own this system is: 1411. 0 Individual 0 Federal Municipality 0 State/County 0 Private Partnership 0 Corporation Ej Other (specify): ce id. P. O. Box 431 - 115 N. Main St. O Street Address if. NC State • 1 h. 704-825-5586 1 i. Telephone 2. Project (Facility) Information: Belmont City lg. 28012 Zip Code 1j. Facsimile E-mail • 2a. Abbington Subdivision CI. Brief Project Name (permit will refero this name) < 3. Contact Person: 3a, Douglas L. Dowell, Jr„ Name and Affiliation of 0 2h. Gaston County Where Project is Located eone Who Can Answer Questions About this Application 3b. 704-660-9697 3c. leland7896@aol.com Phone Number E-mail 1 Project is 0 New Ej Modification fof an existing permit) If Modification, Permit No.: 2. Owner is O Public (skip to Item B(3)) EJ Private (go to Item 2(a)) 2a, If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) 0 Retaining Ownership stare, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc, - skip to Item B(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) El Public Utility (Instruction III) El Homeowner Assoc./Developer (Instruction IV) O 3. City of Belmont Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 5 4a City of Belmont Wastewater Treatment Facility 4b, NC 0021181 O 5a. City of Belmont 5b, 8" 5c. Owner of Downstream Sewer Receiving Sewer Size The origin of this wastewater is (check all that apply): ul M Residential Subdivision O Apartments/Condominiums O Mobile Home Park O School 0 Restaurant 0 Office 0 Car Wash 0 Institution O Hospital O Church El Nursing Home 0 Other (specify): Name of WWTF WWTF Perrnit No. Permit Number of Downstream Sewer known) 7. Volume of wastewater to be permitted in this project: 18,320 gallons per day 100 % Domestic/Commercial % Industrial % Other (specify): 8. If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line O Flow has already been allocated in Permit No, Ej Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 z 0 z 0 CK. APPLICATION for GRAVITY SEWERS, PL IP S°I ATIONS, AND FORCE MAINS PAGE 4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application, Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3). 51 Lots @ 360 gallons per day = 18,320 gallons per day 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8„ ENTER TOTAL LINE LENGTH IN MILES Length (feet) 3030.0 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Design Flow Operational Point 0 (as shown on plans) (MGD) GPM @ TDH Z Gravity or Force Main (pull down menu) Gravity Gravity Gravity Gravity Gravity G ravity Gravity Power Reliability Option (dual line feed, permanent generator w1ATS, portable generator wltelemetry, wet well storage) 12, Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H ,0200 as applicable? 0 Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No ❑ N/A Sedimentation and Erosion Control Plan? J Yes ❑ No ❑ N/A Stormwater? El Yes ❑ No ❑ N/A FTA 02//03 _1( APPLJCATJ[ON for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1, Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following; El A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody: AND, 111 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID Name of Waterbody Stream Waterbody on Map Waterbody County River Basin Index Classification Site Fites Gaston Catawba 11-121-(1) WS-IV Submit the 8,5" x 11" topographic map as required In In 1. Applicant's Certification: ru n VI regardless of whether a classification is provided! 1, Barry Webb , attest that this application for Abbington Surdivision has been reviewed by me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B. any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as c!vJp.iftes up to $900 p violation. la. z". Signing Officl Sj1ature 2. Professional neer's Certification: I attest that this application for Douglas L. Dowell, Jr. has ,been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that/ have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowngly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a Doinlas L. Dowell, Jr., PE, PLS Professional Engineer Name 2b: Dowell & Company, PC Engineering Firm 2c. P. 0, Box 3504 Address 2d, Mooresville City 2g. 704-660-9697 Telephone 2h, 704-664-5177 Facsimile 2e, NC 2f. 28117 State Zip 2i, IeIand7896aoLcom E-mail FTA 2/03 'MOUNT HOLLY, NC 35081=C 1-TF-OO24 1993 DMA 47.54 V ST.-SERft VE,42 (BELMOrF 4764 LJL O3 A DOWELL & CO., P.C. Engineering * Surveying *Planning 344 Rolling Hills Drive * Suite 103 * Mooresville, NC 28117 Office: (704) 660-9697 Fax: (704) 664-5177 leland7896@aoLcorn TO: NC DENR Attn: Ms. Dec Browder LETTER OF TRANSMITTAL Date: 8/21/07 Job No: 06-642 Re: Abbington Subdivision 01....# . rsN imietovkL pt. OtJRCEs r!tpl F WE ARE SENDING YOU Attached Ei Under separate cover via HE FOLI,OWING ITEMS: 0 Shop Drawings LI Copy of Letter Prints Plans 0 Change Order 0 Other: LI Samples 0 Specifications opies N Sewer Applications USGS Maps Check 4734 for $400.00 THESE ARE TRANSMITTED AS CHECKED BELOW: For approval E For your use 0 As Requested 0 For review and comment El FOR BIDS DUE REMARKS: 0 Approved as submitted. 0 Resubmit 0 Approved as noted El Submit 0 Returned for corrections 0 Return 0 Other: 0 PRINTS RETURNED AFTER LOAN TO US Copy To: Signed: copies. for approval copies for distribution corrected prints Central Files. AP 08 Permit Number 00 Permit Tracking Slip Program Category scan disharge Status Active Project Type New Project Permit Type Fast Track Version Permit Classificatrora Gravity Sewer Extension, Pump Stations, Pressure Sewer 100 Extensions Primary Reviewe dee. browder Permitted Flow 18320 Feility Facility Name Addington Subdivision Location Address Owner Owner Name City of Belmont Dates/vent Individual Permit c ntact Affili Lion Major/ in Region Minor Mooresville County Gaston Facliity Contact Affiliation Owner Type Government - Municipal Owner Affi l iatin Barry Webb PG Box 431 elmunt N 28012 Scheduled rig issue- App Received Draft Initt tect Issuance Public Notice Issue Effect - 08i31 /07 08/ 1 /0 r 08/ 1 / 708/31 /07 Reditlatect Activities Subdivision an pivect Event Additional info rtnaticrn requested ter co leceon Additional inresrniation received Out al UL body Name a, nde Numb Expiration Currant Class Subbasin o 4) Michael F. Easley, Governor Willuan� G Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen Sullins, Director Division of Water Quality August 7, 2008 City of Belmont P.J. Box 431 Belmont, North Carolina 28012 Attn: Barry Webb, City Manager SUBJECT: Abbington Subdivision Permit No. WQ0032111 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for fire subject project on July 2, 2008. A ful! review'at the certification materials may or may not be conducted. It is assumed that receipt of' this certification indicates compliance with ail regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not re+oeived a copy, please contact your consultant immediately to obtain a copy. You are recei` Ind this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from tp]ih2o E:nr t$P nc usLn,dpulnasuapps,htr1 E Seryy t. if you have any questions concerning this document or the completion of Form P NOCF-S necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@no mail net, erely, &Q 1 f , t-tiC Robert Krebs Surface Water Protection Regional Supervisor Enclosure Cc: Douglas Dow, 11, uvw°eS Co„ PC Surface 'vVcter Prates Mbar Central Files (pert Ecotton page an t„o i na Pretreatment, Emergency Response and Cote 1617 Mal Service Center, Raleigh, NC 27999-18'17 Telephone (919) 733-50083 Fax (919) 733-00 9 Internet htlp..rih2o_enr.ncstate.us/ndpu An Equal opportun,ty Actuon Employer 5055 recycled/10% post -consumer paper Fast Track Engineering Certification , Permit No, VVQ0032111 August 31, 2007 nerANVOrP/WQCS PE Barry Webb, City Manager Douglas Dowell City of Belmont Dowell & Company, PC PO Box 431 PO Box 3504 Belmont, NC 28012 Mooresville, NC 28117 Complete and submit this form to the permit issuing regional office with the following, One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Per Li modifications are required for any changes resulting in non-compliance with this permit regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial No Final vv 1 " , as a duly registered Professional Engineer in the State of North Carolina, having been authoredto observe periodically, [11 weekly, full time) the construction of Abbington Subdivision, a Gaston County project for the ermittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: olle SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collectionsystem extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions,. DWELL & CO,. P.C. Engineering . Surveying * Planning 344 Rolling Hills Drive , Suite 103 4 Mooresville, NC 28117 Office: (704) 660-9697 Fax: (704) 664-5177 Email: l l411d7896 c)ao .coin Attn: Ms. Dee Bro 'der SENDING YOU Ill Attached E FOLLOWING ITEMS: ❑ Shop Drawings ❑ Copy of Letter Prints Change Order LETTER OF TRANSMITTAL Date: 7/2/08 job No: 07-642 Re: Abbington Subdivision. © Under separate cover via El Plans © Samples Other: NC DENR M t tIt44AoN I!44 1' AV!x ❑ Specifications Crap AA -Built Ertirteers C"ertioatitatr Deserlp T IESE ARE TRANSMITTED AS CHECKED BELOW: For approval ❑ Approved as submitted 0 Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution ❑ As Requested ❑ Returned for corrections ❑ Return corrected prints ❑ For review and comment 0 Other: ❑ FOR BIDS DUE D PRINTS RETURNED AFTER LOAN TO US REMARKS: Copy To: Signed: