Loading...
HomeMy WebLinkAboutWQ0024795_Regional Office Historical File Pre 2018Michael P. Easley, Governor William (1. Ross Jr,. Secretary North Carolin.a. Depanment al -Environment and Natural Resources Alan IA', Klimek., P.E. Director Dion of Water Quality January 21, 2005 Mr. Barry Webb, City Manager City of Belmont Post Office Box 431 Belmont, North Carolina 28012 Subject: Permit No. WQ0024795 City of Belmont Wal-Mart Store # 5085-00 Wastewater Collection System Extension Gaston County, North Carolina Dear Mr. Webb: In accordance with your application received on January 12, 2005, we are forwarding herewith Permit No. WQ0024795, dated January 21, 2005, to the City of Belmont for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application, It shall be the Perrnittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules, Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax (704) 663-6040 Internet: h2o,enr.state.nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycled/10% Post Consumer Paper NgerthCarolina aturally Mr, Barry Webb Page 2 January 21, 2005 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Belmont for the construction and operation of approximately 1,820 linear feet of 8- inch gravity sewer to serve 188,640 square feet of comrrmercial space as part of the Wal-Mart Store # 5085-00 project, and the discharge of 22,640 gallons per day of collected domestic wastewater into the City of Belmont's existing sewerage system, pursuant to the application received January 12, 2005, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Belmont WWTP (NPDES No. NC0021181) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North. Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. cc: Gaston County Health Department Mooresville Regional Office, Water Quality Section James Freeland, Freeland and Kauffman, Inc. Water Quality Central Files Marie Doklovic, PERCS Sincerely, 1)-C' for Alan W. Klimek, P.E. F Permit No. NC0021181) NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER CO LECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 28 .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7% A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this perrnit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. in the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. e 21st day of January, 2005. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024795 Fast Track Engineering Certification Permit No. WQ0024795 January 21, 2004 Complete and submit his form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications arefeouired fgr any changes resulting in non-compliance with this permit, regulations or minimum design criteria, This project shall not be considered complete nor allowed to operate until this Engineers Certification and all required supporting documentation have been received by the Division. Therefore, it Is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial El Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically, 0 weekly, 0 full time) the construction of the Wal-Mart Store # 5085-00, Gaston County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: IT SEND THIS FORM & SUPPORTING DOCUMENTATION REQUIRED ATTACHMENTS,ToTHE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions: °TRACK: �APICATION for GRAVITY SE'y°4'ERS, PC STATIONS, AND FORCE MAINS PAGE 3 0 0 EL • 1 f. North Carotin State 0 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD (City of Belmont) Full Legal Name (company, municipality„ HOA, utility, etc.) 1 b. Mr. Barry Webb j ity Manager) Application Number: (to be completed by OWQ) Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) lc. The legal entity who will own this system is: ❑ Individual ❑ Federal Municipality ❑ State/County ❑ Private Partnership ❑ Corporation ❑ Other (specify). a. id. f3.0. Box4 Street Address lh. 17041825-5 86 1i. (704) 825-0514 Telephone Facsimile 2. Project (Facility) information: 2a. Wal-Mart Store fI5085-00 Brief Project Name (permit will refer to this name 3. Contact Person: • 3a. Rogan Martin — Freeland and Kauffman, Inc. 0 2 0 LL Z le. Belmont City lg. 28012 Zip Code 1j. bwebb@cityofbelmont.org E-mail 2b. Gaston Count County V Ihere Project Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (8641672-3439 Phone Number 1, Project is New i j Modification 3c. rmartin@fk-inc.com E-mail of an existing permit) If Modification, Permit No.: ted For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line sizeflength, etc.). Only include the modified information in this permit application • do not duplicate project information in B(7) and B(10-11) that has already been included In the original permit. 2, Owner is ® Public (skip to Item 8(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose tine El Retaining Ownership (i,e. store, church, single office, ❑ Leasing units (lots, townhomes, etc, - skip to Item (� ❑ Selling units (lots, townhomes, etc.. - go to Item B(2b, City of Belmont Owner of Wastewater Tre 4a City of Belmont Wastewater Treatment Plant Name of WWTF 5a. City of Belmont Owner of Downstream Sewer The origin of this wastewater ❑ Residential Subdivision Apartments/Condominiums O Mobile Home Park ❑ School Restaurant ❑ Office c.) or ❑ Public Utility (Instruction III) ❑ Homeowner Assoc./Developer (Instruction IV) t Facility (WWTF) Tre 9 astewater From This Project 4b. NC 0021181 WWTF Permit No. 5b. 12-inch / 8-inch 5c. N/A Receiving Sewer Size Permit Number of Downstrea check all that apply): El Car Wash ❑ Institution 0 Hospital Church ❑ Nursing Home Other (specify), Commercial 7. Volume of wastewater to be permitted in this project. 22,640 gallons per day Sewer (if known 100 % Domestic/Commercial % Industrial Other (specify): If the permitted flow is zero, indicate why. O Interceptor Line - Flow will be permitted is subsequent permits that connect to this line El Flow has already been allocated in Permit No. El Rehabilitation or replacement of existing sewer with no new flow expected 16,r,R fe ^Y fF`Y a4 rh rYA iYXA i -TRACK APPLICATION for GRAVITY SEWERS, PUMP .STATIONS, AND FORCE MAINS PAGE 4 Ui z z 0 z z 03 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H ,0219(I) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below, Values other than that in 15A NCAC 2H ,0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H ,0219(1)(3). 120 Gallons per day per 1,000 square feet = 188,64 x 120 = 22,640 GPD (Store Area — 188,640 sf) 10. Summary of Sewer Lines to be Perrnitted (attach additional sheets if necessary) Size (inches) 8 Length (feet) 1820 ENTER TOTAL LINE LENGTH IN MILES 0.345 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Gravity or Force Main (use the pull down menu) Gravity Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator ye/telemetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? rj Yes 0 No N/A Sedimentation and Erosion Control Plan? Z Yes fl No Ej N/A Stormwater7 Z Yes 0 No 0 N/A r'r rA, 4,n" rc.4 IT TRACK APPLIL TTON for GRAVITY SE v6'ERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 z 0 z 0 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/0 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets a necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following. El A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down siope waterbody; AND, D A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of map for cross-reference) Waterbody County Mount Holly UT to Catawba River Gaston County 1 a. River Basin Catawba River hacin Waterbody Stream Waterbody Index Classification 11 — (122) WS IV & B CAA Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: 1, Barry Webb, attest that this application for Wal-Mart Store #5085-0© has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note, In accordance with North Carolina General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2.misdemeanor which may include a fine not to exceed $10, 00© as well as civil penalties up to $25,000 per violation. Signing Official Si ature 2. Professional Engineer's Certific ton. 1 attest that this application for Wal-Mart Store#5085-00 in Belmont, North Carolina has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and se& signifies that I have reviewed this material and have judged it to be consistent with the proposed design, Nate: in accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may, fine not to exceed $10,000 as well as civil penalties up to S25,000 per violation. 2a. James R. Freeland Professional Engineer Name 2h. Freeland and Kauffman, Inc Engineering Firm 2c. 209 est Stone Avenue Address 2d, Greenville 2e. SC 2f. 29609 City State Zip 2g. (864) 233-55497 2h. �864) 233-8915 2i, Telephone Facsimile E-mail Seal„ Signature k: Date 10'1' .A, ev,5 d�, Permit Number Q0024795 Perm Tracking Slip 01( 1I5 Prow in ateg r Status Prolect Type Non -discharge In review New Project Permit Type Fast ra It Version Permit Classi abort Gravity Sewer Extension, Pump Stations, Pressure Sewer Individual xtensions Primant Reviewer sonjab singer Permitted Flow 22640 Facility Name aEMart Store # 508500 Location Address Owner Owner Name City of Belmont DasiEves PennContact A iiiation Major! Minor nor Region Mooresville County Gaston Facility Contact Affiliation Scheduled Orig Isaac Apo Received Draft tnttiated issuance Public Notice Issue 01/1, 1 a Owner Type GovernmentMunicipal' Owner Affiliation Barry Webb PO Pox 431 Belmont Regulated Activities r industrial, other ater rtallection off. NULL terbodv Name strew index' Number NC i12 Effect Expiration e uestad/Received Even Additional infrarrraatidn requested Additional irtforrraatirtn received Cu Subbasin Sif As Shown Checked by: DAH Drawn by: qL Date: 1,25.02 ENGINEERING TESTING ENVIRONMENTAL SERVICES USGS TOPOGRAPHIC MAP 22-Acre Wal-Mart Super Center Property Belmont, Gaston County North Carolina Job No 1261-02-006 Figure No, 2 F EELAND an J 1 MAN, INC. ENG1NEEfi5 • LANDSCAPEARCH1rECT5 January 10, 2005 To: NCDENR -- Mooresville Regio From: Rogan Martin Re: Wal-Mart Store #5085-00 Belmont, North Carolina a O fice Affiliate and -Kauffman wican, Inc. 5entonvlUe, Arkaneaa Enclosed are one original and one copy of the fast track application for gravity sewer for the proposed Wal-Mart Store #5085-00 in Belmont, NC. Also enclosed are two copies of the flow acceptance letter from the director of the public works, department for the City of Belmont, a color USGS topographic map and a check in the amount of $400.00, Please call me at (864) 672-3439 if there are any problems with this application or if you require additional information. Thank you for your time and help with the processing of this application. J A. 209 West Stone Avenue • Greenville, South Carolina 29Tetcpione 864-233-5 97• Fax 864--233-5915