HomeMy WebLinkAboutWQ0017885_Regional Office Historical File Pre 2018State of North Carolina
Department of Environment
and Natural Resources
Division of Water Quality
James B. Hunt, Jr., Governor
Bill Holman, Secretary
Kerr T. Stevens, Director
January 25, 2000
MITCHELL B. MOORE, CITY MANAGER
CITY OF BELMONT
POST OFFICE BOX 431
BELMONT, NC 28012
Dear . Moore:
NORTH CAROLINA DEPARTMENT OF
ENVIRONMENT AND NATURAL_ RESOURCES
Subject: Permit No, WQ0017885
City of Belmont
Park Street Subdivision
Wastewater Collection System
Gaston County
In accordance with your application received January 4, 2000, attached is Permit No,
W(2001.7885, dated January 25, 2000, to the City of Belmont for the construction and operation of the
subject. wastewater collection extension.
This permit shall be effective from the date of issuance until rescinded and you shall be subject
to the conditions and limitations as specified in the North Carolina Gravity Sewer Design Criteria
adopted February 1.2, 1996 and the attached permit.
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North
Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted
for the construction and operation of approximately 1,672 linear feet of 8-inch gravity sewer to serve
300 office employees as part of the Park Street Subdivision project, and the discharge of 7,500 GPD of
collected domestic wastewater into the City of Belmont's existing sewerage system, pursuant to the
application received January 4, 2000, and in conformity with the North Carolina Gravity Sewer Design
Criteria.
The sewage and wastewater collected by this system shall be treated in the City of Belmont
Wastewater Treatment Facility (NPDES Permit No. NC0021181) prior to being discharged into the
receiving stream.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of
this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North
Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding,
1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 FAX (919) 715-6048
An Equal Opportunity Affirmative Action Employer 50% recycled( 10% post -consumer paper
The issuance of this permit does not preclude the Permittee l"rcan coin lal ira ith any and all
statutes, rules, regulations, or ordinances which may be imposed by other g ve1» men t agencies
Ira ai
state, and federal) which have jurisdiction.
(
you need additional nforrnation concerning this
-5083 extension 375,
Since]
ple contact Natasha Powers at
Ket r " , Sto
cc: Gaston County Health Depa -trr�ertt
Mooresville ille Regional Office, Water Quality Section
Mansour Edlin Consulting
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
GRAVITY SEWER COLLECTION SYSTEMS PERMIT
This permit shall be effective from the date of issuance until rescinded and shall be subjectto the
following specified conditions and limitations:
1. This permit shall become voidable unless the facilities are constructed in accordance with the
conditions of the Division of Water Quaiity Gravity Sewer Design Criteria adopted February 12,
1996.
This permit is effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
The facilities st be properly maintained and operated at all times.
4. This permit is not transferable. in the event there is a desire for the facilities to change ownership,
or there is a name change of the Permittee, a formal permit request must be submitted to the
Division of Water Quality (Division) accompanied by an application fee, documentation from the
parties involved, and other supporting materials as may be appropriate. The approval of this request
will be considered on its merits and may or may not be approved.
Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing
utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the
State.
6. Upon completion of construction and prior to operation of this permitted facility, a certification
and a copy of the record drawings (i.e., as constructed plans) must be received from a professional
engineer certifying that the permitted facility has been installed in accordance with the Division of
Water Quality Gravity Sewer Design Criteria adopted February 12, 1996, and other supporting
materials. If this project is to be completed in phases and partially certified, you shall retain the
responsibility to track further construction approved under the same permit, and shall provide a final
certificate of completion once the entire project has been completed. A copy of the record
drawings, indicating the facilities constructed in the phase being certified, shall be submitted with
each partial certification. Mail the Certification and one (1) copy of the "Record Drawings" to the
Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617.
7. A copy of the Record Drawings shall be maintained on file by the Permittee for a minimum of five
years from the date of the completion of construction.
Failure to abide by the conditions and limitations contained in this general sewer permit or the
North Carolina Gravity Sewer Design Criteria may subject the Permittee to an enforcement action
by the Division, in accordance with North Carolina General Statute 143-215.6A to 143-2,15.6C.
1
9. In the event that the facilities fail to per . factorily, including the creation of nuisance
conditions, the Permittee shall take immediate corrective action, including those as may be required
by this Division, such as the construction of additional or replacement wastewater collection
facilities.
10. Noncompliance Notification:
The Perrittee shall report by telephone to the Mooresville Regional Office, telephone number (704)
663-1699, as soon as possible, but in no case ruore than 24 hours or on the next working day,
following the occurrence or first knowledge of the occurrence of either of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps, line
blockage or breakage, etc., or
b. Any failure of a sewer line resulting in a by-pass directly to receiving waters without treatment
of all or any portion of the influent to such station or facility.
Persons reporting such occurrences by telephone shall also file a written report in let -ter form within
five (5) days following first knowledge of the occurrence. This report must outline the actions
taken or proposed to be taken to ensure that the problem does not recur.
Permit issued this th nty-fifth day of January. 2000
NORTH
NII?NTMENTAL MANAGEMENT COMNIISSION
Kerr T. Stevens, Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Nurraber WQ0017885
!FIlir
Perr it �No. WQOO17SSS
January 25, 2000
ENGINEER'S CERTIFIC. TION
Partial Final
as a duly registered Professional Engineer in the State of North
Carolina, having been authorized to observe (periodically, weekly,
project,
Project Name
me) the construction of the
Location and County
for the
Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation
of the construction such that the construction was Observed to be built within substantial compliance of
this permit, the certificate of coverage, the North Carolina Gravity Sewer Minimum Design Manual, and
other supporting materials.
Signature Registration. No.
Date
The above Engineer's Certification must be completed and submitted to the address below with one (1)
copy of the "Record Drawings" (i.e,, as -constructed plans) of the wastewater collection system This
project shall not be considered complete and allowed to operate until this Engineer's Certification and
the "Record. Drawings" plans have been submitted. Any wastewater flow made tributary to the
wastewater collection system prior to completion of this Engineer's Certification shall be considered a
violation of the permit and shall subject the Permittee to appropriate enforcement actions.
NORTH CAROLINA DIVISION OF WATER QUALITY
WATER QUALITY SECTION
PERMITS AND ENGINEERING UNIT
1617 MAIL SERVICE CENTER
RALEIGH, NORTH CAROLINA 27699-1617