Loading...
HomeMy WebLinkAboutNC0021504_Survey_20020813• FAYETTEVILLE REGIONALOFFICE DIVISION OF WATER .QUALITY „ SURVEY OF NPDES PERMITTED FACILITIES PLEASE RETURN ON OR BEFORE AUGUST 16, 2002 :‘-' Ale 11 5 2002 FACILITY ADDRESS: P 0 BOX 1228 BISCOE NC 27209 PHONE NUMBER: 910-428-4112 FAX: 910-428-3975 1. What method of composite sampling is your facility [ ] a.. Continuous currently utilizing? [ ] b. Constant time / variable volume [ ] c. Variable time / constant volume [X ] :d. Constant time / constant volume Please be aware that constant time / constant volume composting must meet the criteria outlined in the code. In addition to the above requested information, please describe your quality control / quality assurance techniques that are utilized in sampling. Please include the following: 2. What type of sample container is used: plastic, glass or metal for composite sampling? PLASTIC 3. What procedures are used to clean the composite sample container? SOAP MI. -WATER AND-_TRIpLE:,RINSE 4. What cleaning agents are used in the cleaning of the composite sample container? DISH WASHING DETERGENT 5. How often is the composite sampler tubing cleaned and / or replaced? IT IS CLEANED EACH TIME IT IS USED (WEEKLY) AND REPLACED ABOUT EVERY 6 WEEKS AS NEEDED v 6. What type of sampling device is used for grab sampling? PLASTIC DIPPERS 7. Is the grab sampling device kept outside? NO, IT IS KEPT INSIDE AT THE PLANT • 8. How is the grab sampling device cleaned? SOAP AND WATER AND TRIPLE RINSE 9. What cleaning agents are used in -the cleaning of the grab sampling device? DISH WASHING DETERGENT 10. Please describe the effluent sampling point. SAMPLES ARE TAKEN AT THE CHLORINE CONTACT CHAMBER AFTER IT HAS PASSED OVER THE WEIR A few other questions related to what typo, of process contral analyses are performed at you, -facility are also included in this survey: 11. Does your facility analyze the following parameters? Parameters Analyzed How Often Mixed Liquor Suspended Solids NO Food / Mass Ratio NO Sludge Age NO Settleable Solids NO 12. Does your facility have Inflow / Infiltration (I/1) problems within the sewer system which flows to the wastewater treatment facility? [x ] Yes [ ] No If you answer YES to the above question, would you consider it to be : [ ] Minor [ X ] Moderate [ ] Severe If the I / I problems are moderate or severe, what are the_plans or what is being implemented to eliminate this from your system? W K DICKSON HAS JUST COMPLETED SMOKE TESTING OUR COMPLETE SEWER SYSTEM AND ARE SENDING US MAPS, PICTURES AND THEIR RECOMMENDATIONS AS TO REPAIRS THAT SHOULD BE MADE 13. Do you have access to the INTERNET at your facility and if so, what is your facility's INTERNET address? NO Survey Completed By: ,��� Date: 2 / /J /02