Loading...
HomeMy WebLinkAboutWQ0032113_Regional Office Historical File Pre 2018Michael E. Easley, Govern() William G, Ross Jr., Secretary North Car- f Environment and Natural Resources Coleen 1 Sullins, Director Division of 'Water Quality August 23, 2007 Mr. Brad Cornwell, Utilities Director City of Shelby 824 West Grover Street Shelby, NC 28150 Subject; Permit No, WQ0032113 Shelby Airport Lift on Wastew.a-ter Collection Sys Cleveland County, North Carolina Dear Mr, Stewart, In accordance with your application received on August 1, 2007, we are forwarding herewith Permit No, WQ0032113 dated August 23, 2007, for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable, 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215,6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. MooresvilleRegional Office 6 Ell East Center Ave,, Suite 301 Mooresville, NC 2811.5 Internet www,ncmwaterquality.org Customer Service, 1-877-623-6748 An Equal Opportunity/Affirmatiye Action Employer —50% Recycled/10% Post Consumer Paper .Phone: (704) 063-1699 Fax: (704) 663-0040 Ore Nort ardina AtitUriay Pr, Co'rnwell Page 2 August 23: 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 1,433 linear feet of 8-inch gravity sewer, 446 linear feet of 2-inch force main, a 35 GPM pump station (with duplex pumps, on site audible and visual high water alarms, and a portable generator receptacle with telemetry),and the discharge of 5,000 gallons per day of collected domestic wastewater into the City of Shelby's existing sewerage system, pursuant to the application received August 1, 2007, and in conformity with 15A NCAC 2T, the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Shelby's WWTP (NPDES No, NC0024538) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Since ly, Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files D. W. Odom, Odom, Hollifield & Assoc. Engineering, Inc. Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein, 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times, The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 27 .0403; a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L 0200 or the surface water standards in 15A NCAC 2B ,0200, b. A map of the sewer system shall be developed and shall be actively maintained, c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Per 15A NCAC 2T ,0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit, 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9, In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H ,0500 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence, This report shall outline the actions taken or proposed to ensure that the problem does not recur, Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control, Permit issued this the 23rd day of August 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION r Coieen H, Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Nur-niter W00032113 VFast Track Engineering Certification Permit No, WQ0032113 August 23, 2007 OwneriWQC StWWTP Brad Cornwell, Utilities Director City of Shelby 824 W. Grover Street Shelby, NC 28150 PE D W, Odom Odom, Hollifield & associates Engineering, Inc. 152 E Main Street Forest City, NC 28043 Complete and submit this form to the permit issuing regional office with the following. One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are Lifted for an han es resultin in non-com liance with this lations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION 0 Partial Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (Ej periodically, E weekly, Lil full time) the construction of Shelby Airport Liftstation, a Cleveland County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T, the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable: and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, APPLICATION for GRAViTY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 0 pi USE THE TAB KEY TO MOVE FROM FIELD TO FIELDt z 0 1. Owner: la, CITY OF SHELBY Full Legal Name (company, municipality, HOA, utility, etc.) lb. BRAD CORNWELL, UTILITIES DIRECTOR Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) forauthorized signing officials!) 1 c. The legal entity who will own this system is: 0 Individual 0 Federal Municipality 0 State/County 0 Private Partnership 0 Corporation 0 Other (specify): Application Number: (to be completed by DWQ) 0 ld, 824 W GROVER ST z 0 a. a. Mailing Address if, NC State lh. 704-484-6840 Telephone Facsimile 2, Project (Facility) Information: 2a. Shelby Airport Liftstation and force ain Brief Project Name (permit will refer to this name) 3. Contact Person: 3a. SCOTT ROACH le. SHELBY City lg. 28150 Zip Code 1j, brad,cornwe ofsheltycom li 704-484-6808 2b CLEVELAND County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 31), 828-247-4495 3c, sco domen ineerin .co E-mail Phone Number 1. Project is El New Modification (of an existing permit) if Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is El Public (skip to Item 8(3)) 0 Private (go to Item 2(a)) 2a. If private, applicant will be. 2b. If sold, facilities owned by a (must choose ne El Retaining Ownership (i,estore, church, single office, etc.) or 0 Public Utility (Instruction III) Z EI Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Homeowner Assoc./Developer (Instruction IV) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) 3, CITY OF SHELBY Owner of Wastewater Treatment Facility F Treating Wastewater From This Project 4a, CITY OF SHELBY 4b. WQ0017771 Name of WWTF WWTF Permit No. 5a. CLEVELAND COUNTY .5b. 6" Ili Gravity 15c, WQ0017771 Owner of Downstream Sewer Receiving Sewer Size El Force Main Permit Number of Downstream Sewer (if known) 6. The origin of this wastewater is (check all that apply): 0 Residential Subdivision Ej Car Wash 0 Apartments/Condominiums 0 Institution 0 Mobile Home Park El Hospital E1 School El Church Ej Restaurant 0 Nursing Home El Office El Other (specify): AIRPORT 100 % Domestic/Commercial % Industrial % Other (specify): 7. Volume of wastewater to be allocated for this particular project: 5000 GPD gallons per day *Do not include previously permitted allocations 8, if the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted in subsequent permits that connect to tbs line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected ETA 02103 - Rev. 3 04/05 TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below, Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H ,0219(1)(3). Q = 200 PEOPLE / DAY x 25 GAL 1 PERSON / DAY = 5000 GPD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 446' 1433' ENTER TOTAL LINE LENGTH IN MILES 0.625 Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (self chosen - as shown on Design Floe plans for cross-reference) (MGD) 005 MGD LIFT STAT. #1 Operational Point Gravity or Force Main (use the pull down menu) FORCE MAIN GRAVITY Power Reliability Option (1- dual line feed; 2- permanent generator wiATS; 3- GPM TDH portable generator wltelemetry; 4-wet well storage) 5GPM@ 15' TDH 2. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force; Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the fallowing permits/certifications been submitted for appro Wetland/Stream Crossings - General Permit or 401 Certification? El Yes Sedimentation and Erosion Control Plan? ❑ Yes Stormwater? ❑ Yes 14. Does this project involve aerial lines or siphons? Check if yes: ❑ These lines will be considered hioh orioruty and must be checked once every syx months 15. Does this project have gravity sewer lines designed at minimum slopes? Be aware that the Division will riot accept installed fines more than 10% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. El No QN/A ❑No ®N/A El No N/A FTA 02103 - Rev, 3 04105 4:c uJ 0 -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: Z A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, 0 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification la Submit the 8.5°' x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: 1, BRAD CORNWELL, attest that this application for SHELBY AIRPORT LIFT STATION AND FORCE MAIN has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-2156B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 civilpenaities up to $25,000 per violation, Signing Official Signature Professional Engineer's Certification: Date I, DAVID W. ODOM, attest that this application for SHELBY AIRPORT LIFT STATION AND FORCE MAIN has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, 2a, D. W. ODOM Professional Engineer Name 2b, ODOM, HOLLIFIELD & ASSOC ENGINEERING INC Engineering Firm 2c, 152 E MAIN ST Mailing Address 2d, FOREST CITY City 2g. 828-247-4495 2h, 828-247-4498 2e, NC 2f, 28043 2i, State Zip Telephone Facsimile davidodom@odomengineering. Seal, Signature & Date FTA 02/03 - Rev. 3 04/05 one - Shelby Municipal Airport,USGS Shelby (NC) North Carolina Topo Sap Page 1 of 1 P 0.1 9.2 0.3 9.4 9.5 km 9 0.09 0.18 0.27 0.36 0.45 mi 35° 15' 16"N, 81° 36' 01"VV (NAD27) Shelby Municipal Airport, USGS Shelby (NC) Quadrangle Projection is UTM Zone 17 NAD83 Datum http."//www.topozone.cot t/prinLasp?lat=35.25452&Ion=-81.60021 &s=24&size=l&u=6&la... 7/31 /2007 0enlral Files: APS SwF, 08/22/07 Number W00032113 PermIt Tracking king Iip Program Category (on -discharge Status In review Permit Type Fast Track Version Gravity Sewer Extension, Pump Stations Pressure Sewer A Extensions Primary Rayiew dee.brorder Permitted Flow 5000 Project Type New Project Permit Classiffcation Individual Permit Contact Affifiatit n Facility Name Shelby Airport Location Address Owner inn Owner Name City of Shelby nts Ori Issue App Received Draft Initiated 08/2 /0i7 08/22107 Regulated Activities REastevvatcr collection Off all NULL body Name Scheduled Issuance ajort mtinor Region Minor Moores County Cleveland Facility contact Affiliation Owner Type Government Municipal Owner Affiliation Brad Cornwell PO Box 207 Shelby NC 28151 Public Notice Issue Effective Expireticrr 08/23/07 8/2 / 7 Received Events Aricditicrnal inform ati on requested Ardcdif onafi inform n received arcs Index NumberCurr nt Clas Subbasrn ODOM, HOLLIFIELD & ASSOCIATES ENGINEERING, INC. (828) 247-4495 FAX (828) 247-4498 152 EAST MAIN STREET FOREST CITY, NC 28043 PAY TO THE NCDENR- ORDER OF Four Hundred, and owlo0**********m*******,0**************************************.f********* sraosimoimmoniramgmAmsworm. CAFIOUNA FIRST BANK FOREST CITY, NC 28043 67-219/539 1427 ,ttaTat.gt . 9230 7131.12007 $ "400 00 MEMO NCDENR- Moorseville 610 'E, Center Ave, Suite 301 Mooresville, NC 28115 00 1:0 0 2 /971:7 OO6 200 SI-ole DOLLARS 152 East Main St.- Forest City, NC 28043 • 828/247-4495 • Fax if 828-247-4498• TRANSMITTAL SHEET To: Attn: Re: We are sending copy (ies) of the f Shop drawings Letter For approval For review and comment Remarks Cb Make corrections noted As requested Date: Plans Specifications Pay RequestOther Signed FtTrack Enqineerip Permit No. WQ0032113 August 23, 2007 OwnerNVQCSAMWTP Brad Cornwell, Utilities Director City of Shelby 824 W. Grover Street Shelby, NC 28150 C ertIflatIon PE D W. Odom Odorn, Hollifield & associates Engineering, inc. 152 E Main Street Forest City, NC 28043 Complete and submit thie form to the permit issuing regional office with the ilowing: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit mdifIcattons are reouired for any chanQes resultingw minimum design criteria, This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it Is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S PERTIRCATION 0 Partial (Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe periodically, El weekly, 0 full time) the construction of Shelby Airport Liftstatkm, a Cleveland County project for the Perrnittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1998 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking ail partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the pe11tand Shall subject the Permitte*tellippopriate enforcement actions. 7j. ET WELL CALCS Flow Length of Line Starting Elevation Ending Elevation Line Size Friction Coefficient Starting Pressure Head Loss Flow Velocity Pressure Drop Cycle Time UNITS VALUE gpm 40 ft 460 810 2 140 psi ft 24 in fps 4 psi 10 20 mins Design Flow to RS, 7 gpm Pumping Rate of Single Pump 40 gpm WeNvel Size 6 ft torage Volum Gallons Per Foot Storage Height 115:50 gal 211 gal 1 ft