Loading...
HomeMy WebLinkAboutWQ0039737_Regional Office Historical File Pre 2018Water Resources ENVIRONMENTAL QUALITY January 1 I, 2018 Warren Wood, City Manager City of Hickory 76 North Center Street Hickory, NC 28601 ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director Subject: Permit No. WQ0039737 City of Hickory R3100A Utility Extension Wastewater Collection System Extension Permit Catawba County Dear Mr. Wood: In accordance with your application received. January 10, 2018, we are forwarding herewith Permit No. WQ0039737 dated January 11, 2018 to the City of Hickory (Peuiiittee) for the construction and operation. upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteriaand rules. Failure to comply may result in penalties in accordance with North Carolina General. Statute § 1.43-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. State of North CaroEnviran,t ental Quality Toter Resourees oa r t amlity Req onai E Aerations Mooresville Regionli t?l tc 610 East Center Avenue, Strata 3G}l (Moores ille, l r lr Carol na 1111; 704 663 1699 If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicator)/ hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact lion Snider at (704) 235-2196 or via e-mail at ton.snider ainedenr. ov. Sincerely, by W . Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ cc: Miles A. Wright, PE (E-copy) Mooresville Regional Office Files Water Resources Central Files PERCS (Escopy) Page 2 of 8 Environmental Quality STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY WASTEWATER COLLECTION SYSTEM EXTENSION' PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hickory Catawba County for the construction and operation of approximately 4,597 linear feet of 8 inch gravity sewer as a dry line constructed within a NCDOT project for future use and the discharge of 0 gallons per day of collected wastewater into the City of Hickory existing sewerage systern, pursuant to the application received. January 10, 2018, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Purnp Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein, by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ By authority of the Environmental Management Commission Permit Number: WQ0039737 Permit Issued:. January 11, Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET City of Hickory is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. Permitting of this project does not constitute an acceptance of any part of the project that does not meet I 5A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS 1) This dry line shall have 0 flow until an application for permit modification for an incr a in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304 (b)J. II. STANDARD CONDITIONS 1. This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein, [15A NCAC 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all. times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 1.5A NCAC 2T ,0403. If an individual permit is not required., the .following performance criteria shall be met; [15A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained, Page 4 of 8 c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six months and inspections documented. g. A general observation of the entire e system shall be conducted at least once per year. Overflow's and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1 For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permit -tee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volurne„ that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part 1 of Form CS-SSO (or the most current Division approved form) within five days following first Page 5 of 8 knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can -also be completed to show that the SSO was beyond control. [G.S. 143- 215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State, [ISA NCAC 02T,0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the fortn. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis, If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in non-compliance with this peonit, regulations,. or the Minimum Design Criteria should be clearly .identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): 'Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10°A or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria, Requested modifications or variances to the Minimu.m, Design Criteria will be reviewed on a case -by -case basis and each on its own merit..Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] Page 6 of 8 1➢. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .01161 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes § 143-21.5.6A through § 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] In the event that the wastewater collection facilities 'fail to perform satisfactorily, 'including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page 7 of 8 FAST TRACK SEER ENGINEERING CERTIFICATION PERMITTEE: CITY OF HICKORY PERMIT #: WQ0039737 PROJECT: R3 I a©A. UTILITY EXTENSION ISSUE DATE: JANUARY 11, 2018 This project shall not be considered complete nor allowed to operate in accordance with standard Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Regional Supervisor, Water Quality Regional Operations Section at the address noted in the page Tooter. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received by the Division. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional. Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION as a duly registered Professional En ineer in the State of North Carolina, having been authorized to observe ( periodically, P weekly, [J full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track .Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: Final [1 Partial (include description Certification Comments/Qualifiers (attach if necessary): NCDWR hdnnrr�c�ril4, uality Regional Operations Section 610 East Center Avenue, Suite 301, Mooresville, NC 28115 i nffer© Phr,rP' irnna F,A3_1ACP FAN.- 17nan_r��-;ntfn Division of Water Resources State of North Carolina Department of Environme.nttml Quality Division of Water Resources IS 1. NCAC" 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number; A d ned APPLICANT INFORMATION: 1. Applicant's name: City of Hickory (company, murticipalit HOA, utility, etc.) 2 Applicant type: ❑ Individival1 ❑ C:orporatia n. ❑ Ciew rat Partnership ❑ Privately ( i eti Publl © Federal - g name.: Warren �_�, s rren Wood per �. t nature auth�'artt�.', Title: City hla.naner 4. Applicant's mailing address City:Hickory° State: NC Z"op: 2860 ❑ State/Con raty Municipal (h) Applicant's contact into. ntatlottt Phone number: (828) a2a3-7412 Email Address: woodhdhickorvnc aov PROJECT IFOR\I'UION: 1. Project name: R3100A wUtility:Extension 2, Application/Project status: Z Proposed (Nei Pertu t) ❑ Exiting Permit•'`Project If a modification., provide the existing permit number: V »t10 and issued date: If new construction but part of a master plan, provide the existing permit number: W Q00 3, County where project is located: Catawba 4, Approximate Coordinates (Decimal Degrees;: I attitude: 35,606 Longitude:-81.1.13Ci " 5. Parcel. lD (if applicable): (or Parcel It) to closest downstream sewer) III. CONSULTANT INFORMATION:: I. Professional 1- nnineer:'vliles A. Wright,,PE Firm. Wright & Associates Mailing address: 209 1' Ave South City: Conover State: NC Phone, number: (828) 465-2205 Zip: 286 I J- ilta°ratl Address: mi License 'kutrilet•. 24934 riQhtandassOi a IV. WASTEWATER TREATMENT FACILE"T"F (WWTF) INFORMATION: I. Facility Name: Permit Number: Owner Name: cite' of Hickory RECEIVING DOWNSTREAM SEWER INFORMATION Ct:tdifferent than VWTF): ,Permit Nun;'laer(s): AtiaQa. y' tar: st=i.l Owner Namei`s). Dowraastrearn (Re NA inch FORM: ETA, 04-. 6 Prge 1 of GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Ow lithe Applicattt is a Develop; tithe .Mpphc;an is a l [,,ina'Prer Onin of wastewater: (check all t © Residential Owned ❑ Residential Leased ❑ School t` preschool f" da ❑ Food and drink fac. ❑ Businesses offices I fact( Nature of w;astewat.er :d Public Utility, has a Certificate of Public C 'yes ON/A Ly apply}: 0 Retai..l (stores, centers, malls) ❑ Retail with food preparation/service Q Medical/denial ' veterinary facilities Q Church Nursing Home, °fo Dome.-ticr'C.ornmercial o Industrial {4 I 5 A NC "sd;' d£ ce ry been attached? been attached`.' attached'' ❑ Car Wash Hotel and'or Motels ❑ Swimming. Pool =°`Clubhouse Swimming Pool/Filter Backwash ® Other (Expi ain in Attachment) �Fu Commercial aPretreatment Program in effect? Has a flow reduction be•rn approved under 15:i N 'tC } 1 J(t)? ❑ yes If yes, provide.a cony of flow reduction approval IeRer Sumrnari ater generated by project: tablishment Type (see O T,tl1IA See dwelling; proposed ar ;and residential property ing:S_...4 :A�q,) den tial deve d south or east of the b Per I5A NCAC 02'T ,0[144. desiito Ilow rat determined using available flow datta, water as Wastewater generated b•y project: Q GPI (per l Do not include future flows; or previously per If permitted flow is zero, ina Q Pump Station or (.gravity why: ❑ now has already been allocated in Permit mber' Rehabilitation or replacement of ❑ Other (Explain): Dry • lsti[ No 'No. of Units Flow design GPD GPF) (aPL) GPE) minimum Ilowper s; public access f acilities located near high public use areas; coastal Waterway to be used as vacation rentals as defined ishments not identified [in table I 5A NC,Ac 0 occupancy or operation patterns, and other measured wt) ermined in subsequent permits tha. xpected Conn FORM: FTA 0t-1 b VIE GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC Gravity Sewers): 1, Summarize gravity sewer to he permitted: Size (inches) Length (feet) rietaterial Section If & of the MDC for Permitting of Gra.vity Sewers contains information related to design, criteria Section 111 contains information related to minimum slopes for gravity sewerts) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC PUMP STATION DESIGN CRITERIA (If Applicable) —02,T ,0305 & MDC (PUT „ Stations]Foc COMPLETE FOR EACH PIMP STATION LNCLUDED IN THIS PROJECT 1, Pump station number or name Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3, Desig.nflovv of the pump station: millions gallons per day (tirm capacit)) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head TDH) 5. Summarize the force main to be permitted (for this Purnp Station Size (inches) Length (feet) Material 6. Power reliability in accordance with 15],1 NC A C 02T ,030.50-0,1 ): ID Standby power source or 'pump with automatic activation and telemetry - 15.A .NCAC 02T „0305(h)(1)(13,); Required for all pump stations with an average daily flow greater than or equal to 1.5000 gallons per day .> Must be permanent to facility Or if the pump station has an average daily flow less than 15..000 gallons per day: EJ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)( 1)(C) or [1] Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 021 03o500( 1xc): It shall be demonstrated to the Division that the portable source is owned or contractedby the applicant (draft agreement) and is compatible with the station, f the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel thriefratries, shall be provided in the case of a multiple station, power outage, FORM: FTA 04-16 Page 3 of 5 SETBACKS & SEPARATIONS — (02B ,0200 & 15A NCAC 02T .0305(0): 1, Does the proje,ct comply with all separations found in I 5,\ r44505i t) gIgfg IA NCAC 0217.0305(f) contains minimum separations that shall be provided for sewer systems: Storm sewers and other 'utilities not listed. below (vertical, 2/1 inches Water m.ains (vertical -water over sewer including in benched trenches) Water mains (horizontal) Reclaimed water lines (vertical reclaimed,/ Reclaimed water lines (horizontal - reclaimed over sewer) **Any private or pu.blic, water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoir's used as a source of drinking water **Waters classified WS (except VS-1 or VS-V), B„ SA, ORW, HQW, or SB from normal high water or tide elevation), and wetlands (sce item IX,2) **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches. Ans building toundatt I An v basement Z Yes Setback Parameter* Separation Respire( Top slope of embankment or cuts of 2 feet ur more vrtieaLhei.ght 1 Drainage systems and interceptor drains Any swimming Pools Final earth grade (vertical) 8nches 10 feet inches 2 feet 50 feet 10 feet 5 feet 10 feet ":eel 5 feet „.., 10 feet .36 inches 5,A NCIAC 02 II„0,305i g) contains alternatives where separations in 02T,030,5afl cannot be achieved. **Stream classifications can be identified u,sing the Division's NC_Surface Water C assi rex/ions el. -graze • Ifnoncompliance with 02/1/.0c,05(1) orcg), see Section X of this application 2. Does the project comply with separation requirements for %verlands'.? (50 feet of separation) fl 't es ▪ See the Division's draft separation .requirements for situations 'where separation cannot he meet • No variance is required if the alternative design criteria specified is utilized in design and construction. As built documents should reference the location of areas effected No ID NIA 3- Does the project comply with setbacks found in, the river basin rules per 15,.\ NC.A.0 02.B 1)2.00? Z Ye' 0 No El NIA I'l/his would include Trout Buffered Streams per $A NCAC 2B4O20; 4 Does the project require coverage authorization under a 404 Nationwide or individual -permits or 401 Water Quality Certifications? • Information can be obtained from the ,401 Buffer Permitting ,Branch Lllves El No 5, Does project comply with l5A 02'F,0105.(c.t(6) (addition.ai permits/certifications)? El Yes LI No Per 1,..5A NCAC 0.1 (,),5' e'10 directlyrelated environmental permits or cenification applications are being prepared, have been applied for, or have been obtained, Issuance of this .permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stonnwater management plans, etc,), 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NC,AC, 021.0,..102. "high -priority, sewer" means "any aerial sewer, sewer contacting surface wiiterS, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer, El Yes flNo NIA • if yes, include an attachment with details for each iine, including type (aerial. line, size, material, and loatiun) High priority lines shall be inspected by the permit -tee or its representative at least once every six -months and inspections, documented per 15A NCAC 02T,0403(a)(5) or the permitee's individual System -Wide Collection permit FORM: FITA 04-16 Page ,4 of 5 X. CERTIFICATIONS: 1, Does the submitted system comply with ).5.A : 02T. the M nmtuv and Force M:tins ethee;,st vi2rsitsth and the Graeqs, Sewer MitheitIrn L. Z Yes0 No UN°, complete and submit the VariancetAlternative Design Request application (VADC 10-14) and suppo review. Approval of the r ottestis required prior to submittal of the Fasi 2. Professional Engineer's Certification: 1, (les k, attest that this application for (Professional EngitQer's name from Application Item 111. I.) riteria for the Permitnzeptii ttirthe Sthtipres est version:, as applicable'? a documents for rack AprOcation and supportinu documents. has been reviewed by me and is accurate, complete and consistent with the information. supplied in the plans, specifications, engineering calculations,. and all other supporting documentation to the best of my knowledge, I further attest that to the best of tny knowledge the proposed. design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria. for Gravity Sewers (latest version)„ and the Minimum Design Criteria for the Fast -Track Permitting of. Pomp Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have Judged it to be consistent with. the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215,6B. any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation::i",iti,.: North Carolina Professional Engineer's seal, signature, and date: „. : ,... . - :4- SEAL — 24934 3, Applicant's Certification per 15A NCAC 02T ,0 06(b): 1, '0,171:11 (Signature Authoritys rlame & tide fm Application Item 1.3.) A 11‘ attest that this applicationfor has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that d'art1 required parts of this applicationare not completed and that if all required supportingdocumentation and attachments are not included, this application package is subject to being returned as (ncomplete. 1 understand that any discharge of ,vastewatet from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, andlor criminal prosecution, 1 will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In 'accordance with General Statutes 143-215 6A and 143H2l5.6ft any person who knowingly makes any fa se statement, representation, or certification in any application package shall be glair,' of a Class 2 misdemeanor, which may include a fine not to exceed $10.000 as well as civil penalties up to $25,000 per violation, Date. FORM: FTA 04- 16 Page 5 of 5 USGS science for a changing world U.S. DEPARTMENT OF THE INTERIOR U.S. GEOLOGICAL SURVEY PROP. Olivers SEWERLINE Crossroads PROP. SEWERL9NE R3100 utility Wife a des rjrAt err fray your map. WRIGHT: 209 l' Ave. South ' Conover, NC 2861; • (828) 465-2205 January 9, 2018 NCDEQ Water Quality Section 610 East Center Ave Mooresville, NC 28115 Re: R3100A Utility Extensions Please find the attached:. 1) One (1) Original Fast Track Sewer System Extension Application 2) One (1) Copy Fast Track Sewer System Extension Application 3) One Application Fee ($480) 4) One (1) Original Site Map 5) One (1) Copy of Site Map 6) One (1) Original Street Level Map 7) One (1) Copy Street Level Map If you have any questions or need further information, please contact me. Thank you, Miles A. Wright, PE CIVIL ENGINEERS SURVEYORS Luckman, Debbie From: Miles A, Wright, PE, PLS <miles@wrightandassociates,us> Sent: Wednesday, January 10, 2018 3:07 PM To: Luckrnan,, Debbie Cc: Tuvia, Ori A Subject: [External] RE: Fast Track application for City of Hickory CAUTION: External ernaiL Do not click links or open attachments unless verified.0.Send all suspicious email as an attachment to reportspam@nc.gov.. Deborah, l had talked with Ori about this earlier, the project has 0 flow and is not connecting to Any existing lines. It is a dry line that the County is installing within a NCDOT project for future Use, We were told that in this case we did not need a Flow Tracking Sheet since we are not connecting To an existing sewer. Just let me know if we need to do anything else. Thanks Miles A. Wright, PE, L (828) 465-2205 (828) 850-21.60 Ave South Conover, NC 28613 WRIGHT ASSOCIATES S From: Luckman, Debbie[mailto.debbie,luckman@ncdenr.gov] Sent: Wednesday, January 10, 2018 2.50 PM To: miles@wrightandassociates.us Subject: Fast Track application for City of Hickory Miles, I received the application for City of Hickory/R310OA Utility Extension today. However, I am not able to enter it into the system because it does not have a Flow Tracking sheet, I will hold this if you can get it to me within the next few days. It can be emailed to me. Please call if you have any questions. Thank you ber W 0039737 Pro ram at oryi Nonctscharg Permit Type Gravity Sewer Exxtensiod, Pump taliens, & Pressure ewer Extensions Prim ry Reviews lon.snider Cstet Wule Perrot 0 Fad fly d Flow Central Files. APS Permit Tracking Slip N.otave Version 1.©0 Perm oratact A Project Type New Praiact Permit Classifica Individual Facility Name R 100A Ulility Extension Location Address Owner Regloar Mociresville County Catawba Facll"ety Contact AIllatlon City of Hickory 0rig issue 111 t3i8 Scheduled App Recetrred Draft In[tiateri issuance' 10012018 Regulated Activiti Wastewater collection tt%a Government 4 Municipal PO Box 388 Hickory 1t018 1d 2018 Requested !Received Events NC 28601 Expiration 9 Additional information requested Additional information received Waterlooc Name Sire Index Num Current C Subbasin