Loading...
HomeMy WebLinkAboutWQ0037325_Regional Office Historical File Pre 2018NCDENR North Carolina Department of Environment and Natural Resources jOhOE, SkVQrl8.iN Secretary Donald E.Duncan, Jr. City ofConover POBox 649 Conover, NC2G613 Subject. Permit Nn.VVQOOI7]Z5 City ofConover Conover Station U Wastewater Collection System Extension Catawba County Dear Mr. Duncan: In accordance with your application received on August 26, 2014 we one forwarding herewith Permit No. VV[0037325' dated August 13, 2814, to the City ofConover for the construction and operation of the subject wastewater collection system extensinn. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations, as specified therein. This cove/ letter and supplement shall be considered a part of this permit and are therefore incorporated therein byreference. Please pay particular attention to the following conditions contained within this permit: Condition 11.4: Requires that the wastewater collection facilities he properly operated and maintained in accordance with 15A NCAC 2T.0403 or any individual system -wide collection system permit issued tothe Permi1tee. it shall be responsibility of the City ofConover tn ensure that the as -constructed project meets the appropriate design criteria and rules, Failure to comply may result in penalties in accordance with North Carolina General Statute V143-215.6A through 6143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. if any parts, requirements, or Unnkntiona contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, N[37G99-67I4. Unless such demands are made, this permit shall befinal and binding. Mooresville Regbndk0ffica010East CenerAveue, Moomnville,lCamUna2055 Pku&704-66316�9\ntene|:x�wnpdenr�qry y 0 Conover IhQ0Cl37325 If you need additional information concerning this matter, please contact James Beaile at (704) 663- 1699 or via e-rnall at jamesibealle@ncdenrigov. Division of Water Resources by Michael L Parker Regional Supervisor Water Quality Regional Operations Section tVloaresville Regional Office cc: Pi Scott Bell, Davis & Floyd, Inc, Mooresville Regional Office Water Resources Central Files PERCS (electronic copy) STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Conover Catawba County for the construction and operation of approximately 315 linear feet of 8-inch gravity sewer as part of the Conover Station Ip project, and the discharge of 9,400 gallons per day of collected domestic/commercial wastewater into the Clark Creek WWTP existing sewerage system, pursuant to the application received August 26, 2014, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. ermit issued this the 5th day of September, 2014. for Thomas A. Reeder Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ0037325 �UU�K�U�������������K�������������� .~��"o �n_v�vu~o�v v�� ""�"xoroo" ~~���u~vx .�ovo~u.� City of Conover is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Clark Creek Wastewater Treatment Facility (NCO036196) prior to being discharged into the receiving stream. Permitting ofthis project does not constitute an acceptance of any part of the project that does not meet 154 NC4[ ZT; the Division's Gravity Sewer Minimum Design Criteria adopted February 12' 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting ofPump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application, It shall be the Prrmhtee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. . SPECIAL CONDITIONS I. If, atany time, the additional wastewater flow volume made tributary oothbsewerextemaon is believed to exceed the value permitted herein, a modification shall be requested for this permit from the Division of Water Resources to properly allocate the subject wastewater flow. U.STANQARD CONDITIONS I. This permit bnot transferable. |nthe event there isadesire horthewastewater collection facilities tochange ownership, or there is a name change of the Pornni<tee' a, formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval nfthis request shall beconsidered onits merits and may ormay not beapproved, 1 This permit shall become voidable unless the wastewater collection bc|bks are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12' 1990asapplicable; the Division's Minimum Design Criteria for the Fast -Track Permitting ofPump Stations and Force Mains adopted June I' 200Oas applicable; and other supporting materials unless specifically mentioned herein, 3. This permit shall he effective only with respect to the nature and volume of wastes described in the application and other supporting data, 4. The wastewater collection facilities shall he properly maintained and operated a,all times. ThePermVttee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCA[2T .0403. If an individual permit is no, required, the following performance criteria shall bemet asprovided inl5ANCA[ZT.U4O3: a. The sewer system shall beeffectively maintained and operated at all times to prevent discharge ^oland or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b, A map of the sewer system shall be developed and shall be actively maintained, , ppp7c An operabon and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d, Pump stations that are not connected to telemetry system shall beinspected everyday (Le. 365 day per year). Pump stations that are connected toatelemetry system shall be inspected atleast once per week. e High -priority sewer lines shall be inspected at least once per ever six -months and inspections are documented. 9- A8ene/a�obsemationoftheemtiresevvprsystemshaUbvconductedat)east once per year. Overflows and bypasses shall bereported tm the appropriate Division regional office in accordance with 154 N[A[213 0506(e)' and public notice shall be provided as required byNorth Carolina General Statute §143-215.1C. h. AGrease Control Program isinplace ashmUows� l. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the |egal means to require grease interceptors at existing establishments. The plan shall also include legal moans for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems, 2. For privately owned collection systems' the Grease Control Program shall include at least bi-annual distribution of grease education materials to users of the collection system by the permlttee or its representative, 3, Grease education materials shall bedistributed more often than required in Parts (l) and (l) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows, Right-of-waysand easements shall bemaintained xnthe full easement width for personnel and equipment Documentation shall be kept for Subparagraphs (a) through Q of this Rule for a minimum of three years with exception mfthe map, which shall bemaintained for the life ofthe system, S Noncompliance Notification: The Permitneeshall report bytelephone toawater resources staff member at the Mooresville Regional Office, telephone number (704)6h3-1h99.assoon os possible, but }nno case more than Z4hours oron the next working day, following the occurrence or first knowledge of the occurrence of either of the following� a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSOand/or spill over l'0O0gallons; or c, Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report Overflows and spills occurring outside normat business hours may also be reported to the Division of Emergency Management attelephone number (80D)858-0368or (919) 733-3300. Persons reporting any nf the above occurrences shall file aspill report bycompleting and submitting Part IofForm [S'SSO(or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond 6� Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7 Per I5A N[4C 2T.8116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form Acomplete certification is one where the &m,rn is fully executed and the supporting documents are provided as applicable, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actilons, If the permit is issued to a private entity with an Operational Agreement, them a copy ofthe Articles of |ncorpostion'nmc|arabons/[ovenants/Re»hctiqns, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. Acomp|ere certification is one where the form is fully executed and the supporting documents are provided as apphoab|e. Supporting documentation shall include the foUmwinQ� a. One copy ofthe project construction record drawings (plan & profile viewxmfsemer|ines & force mains) of the wastewater collection system extension, Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined msthe design drawings that are marked up or annotated with after construction information and show required buffers, separation distances' material changes, etc. b` One copy ofthe supporting pump station design calculations (selected pumps, system curve operating point buoyancy ca|cu|vt|omv, available storage if portab|eDenemtm/(s) or storage greater than longest past three year outage reliability option selected) for any PUMP stations permitted as part of this project, c Changes tothe project that donot result |nnon-compliance with this permit, regulations, orthe Minimum Design Criteria should be dearly identified on the record drmwings, on the certification in the space provided, orinwritten summary form. Prior toCertification (Final or Partial)- Permit modifications are required for any changes resoidn8iu non- compliance with this permit (|ncyuding pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regu|at�ons' or the Minimum Design Criteria, Requested modifications orvariances tm the Minimum Design Criteria will he reviewed on a case -by -case basis and each an its own merit, Please note that var)ance5 to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged bythe Division and may not beapproved, thus requiring ,rp|acementorrepair prior \ocertification &activation. 8 A copy of the construction record drawings shall be maintained on file by the Pe(mitteo for the life of the wastewater coNechoofacilities. S� Failure ooabide bythe conditions and limitations contained inthis permit; I5AN[A[2T;the Division's Gravity Sewer Design Criteria adopted February 12' 1998 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June l, 2008 as applicable; and other supporting materials may subject the Permittec to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through g14]-215,6(, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the 10, In the evert that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this DWision, such as the construction of additional or replacement facilities. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 154 NCAC 2 .0200, erosion and sedimentation control requirements in 154 NCAC h. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands urader 154 NCAC 2B ,0200 and 154 NCAC 2H .0500 FAST TRACK ENGINEERING CERTIFICATION Permittee: City of Conover Permit No, WQ0037325 Project: Conover Station II Issue Date: 09/05/14I Complete and submit this form to the permit issuing regional office with the following • One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) in pdf format. Record drawings should indicate the design and the marked up changes during construction. • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. Modifications should be submitted prior to certification. This project shall not be considered complete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. PERMITTEE'S CERTIFICATION , the undersigned agent for the Perrnittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. L Printed Name, Title Signature Date ENGINEER'S CERTIFICATION P Partial Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (I] periodically, n weekly, Eli full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable: and other supporting materials, North Carolina Professional Engineer's Seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS DIVISION OF WATER RESOURCES WATER QUALITY REGIONAL OPERATIONS SECTION MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, z MOM USE THE TAB KEY TO MOVE FROM FIELD TO FIELD Application Number: (to be completed by DWR) / Owner/Permittee: la, City of Conover Full Legal Name (company, municipality, HOA, utility, etc.) 1 b. Donald E. Duncan Jr Ciy Mana,,er Signing Official Name and Title (Please review 15A NCAC 2T .01,06 (01 for authorized signing officials) lc, The legal entity who will own this system is, 0 Individual 0 Federal Z Municipality LI State/County 0 Private Partnership ID Corporation 0 Other ld. Pg Box 549_ Mailing Address if NC State 0 111. 828.464.1191 11 828 465 5177 Telephone Facsimile 2. Project (Facility) Information: 2a Conover Station II Brief Project Name (permit will refer to this name 3 Contact Person: 3a P Scott Bell, PE, Consultant le. Conover City lg. 28613 7014 Zip Code 1j DONALD.DUNCAN CONOVERNC.GOV E-mail 2b. Catawba County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 828.322.2290 Phone Number ai.sbell@clavisfloyd.com E-mail 1 Project is Z New 0 Modification (of existing permit) If Modation, Permit No,: 2 Owner is Public (skip to Item B(3)) Z Private (go kfjem 2(a)) 2a If private, applicant will !pe- p Retaining Ownership (i e. store, church, single office, etc.) or 0 Leasing units (lots, townhomes, eto. - skip to Item B(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. City of Newton Owner of Wastewater Treatment Facility F) Treating Wastewater From This Project 4a. Clarke Creek Name of VVWTF 5a, City of Conover 15b. 8" Gravity 5c. W00034446 Owner of Downstream SewerlReceiving Sewer Size i0 Force Main Permit # of Downstream SewerInstruction F 6, The origin of this wastewater is (check all that apply): 0 Residential Subdivision : 0 Retail (Stores, shopping centers) , 100% Domestic/Commercial 0 Apartments/Condominiums ID Institution % Industrial 0 Mobile Home Park 0 Hospital ,41' 0 School 0 Church (Attach Description) Restaurant E] Nursing Home % Other 0 Office 4 Other (specify): , (Attach Descnption) b. If sold, facilities owned by a (must choose one) O Public Utility (Instruction D) El Homeowner Assoc (Developer (instruction E) 4b. VINVTF Permit No. 7 Volume of wastewater to be allocated or permitted for this particular project, 9,400 gallons per day *Do not include future :flows or previously permitted allocations 8, If the permitted flow is zero, indicate why: 0 Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) 08-13 APPLICATION Page 4 of 6 2 2 0 2 0 I W. 0 U. 9. Provide 1M wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for' the value in Item B(7) ND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 W. 40 gal/seat x 75 seats (restaurant) = 3000 gal 50 gal/100 SF x 12,000 SF (Gym) = 6000 gal 10 ga1/100 SF x 4,000 SF (Yogurt) = 400 gal 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main 8 315 New Gravity 11 Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID: rife (self chosen - as shown on plans/map for reference) Longitude: Latitude: Design Flow Power Reliability Option Operational Point (MGD) 1 - permanent generator w/ATS; Force Main Size Force Main Length GPM @TDH 2 - portable generator w/MTS Pump Station Location ID: nia (self chosen - as shown on plans/map for reference) Longitude: Latitude: Design Flow (MGD) Operational Point GPM @TD11 Power Reliability Option 1 - permanent generator WATS; Force Main Size Force Main Length 2 - portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ri Yes No If Yes, permit number of 2nd treatment facility (RO — if 'yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Permitting_ of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? E Yes 0 No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 08-13 APPLICATION Pa(ze 5 of 6 14. Have the following permits/certific,ations been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401Certification? 0 Yes 0 No 1 N/A Sedimentation and Erosion Control Plan? El Yes El No 0 N/A Trout Buffer Waiver? 0 Yes 0 No N/A Stormwater? 0 Yes 0 No N/A 15. Does this project include any high priority lines (15A NCAC 02T 0402 (2)) involve aerial nes, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: I=J and provide details: 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Name) la, 1, Donald E. Duncan Jr. , attest that this application for Conover Station II _ has been reviewed by Me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incornp, General Statutes 143-215.6A and 143-215,6B, any person who know' certification in any application shall be guilty of a Class 2 misdeme as well as civil penalties up to $25,000 per violation. icial Si e e: In accordance with North Carolina statement, representation, or fine not to exceed $10„000 ate ENGINEERING DESIGN DOCUMENTS MUST BE COMP SUBMITTAL OF THIS APPLICATION THESE DOCUMENTS MUST INCLUDE PLAN AND F SEWERS, THEIR PROXIMITY (1) TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T .0305 0 2. Professional Engineers Certification (Signature of Design Engineer and Project Name) LU 1, P. Scott Bell ,attest that this application for _ Conover Station II _ has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per 2a. Preston Scott Bell Professional Engineer Name 2b Davis & Floyd Engineering Firm 2c. 1073 le Street SE Mailing Address 2d, Hickory City 2e NC 2f 28602 State Zip 2g, 828-322-2290 2h, 2i, sbell@davisfloy_d_com Telephone Facsimile E-mail NC PE ture & Date FTA 08-13 APPLICATION Page 6 of 6 State of North Carolina Department of Environment and Natural Resources Division of Water Resources How Tracking/Acceptance for Sewer Extension Applications (ENE 08-13) Project Applicant Na f New Project Name, for which tlove is being requested: Conover Station 1.1, more than ,,,,tIL FTSE 1)iC4,1' be requirel "Or o single prqleor the u 7i 1 c?" the IHITT!, is not responsible for ail pump s !Oa 011S tit Ot'tg I he 1'0We (1: 'the proposed wastewater flow. .1. Complete this section n if yolt a re the owner of the Wastewater treatment plant, a. WIkrf P Facility Name: Clarks Creek Waterwatcr Treatment PLant b. WWTP Faciliiy Permit /z: NC0036196 c. WW rp facility's permitted llow 5.0 d. Estimated obligated flow not yet tributaryto the \V\\ 0 e. WWfP facility's actual avg.. flow E Total flow for this specific request g.. 'rotal actual and obligated flows to the facility h. Percent of permitted flow used IGO ")94 1 .9 3 8% II, (..-',.omplete this section for each painp station you are responsible for along the route of this proposed wastewater flow. List pump stations located betw"een the project connection point and the WWTP: (A) (11) (C) (D)-(13+C) (I)-(A-D) Desin Obligated, Pump Average Daily Approix, Not Yet Total Current Station firf T1 HOW" Ctirrell t Avg, Tributary Flow l'h. (Name or Capacity:* (Firm 1 pf), Daily Flow, Daily Flow, Obligated Avnilable Number) MO 0 N1GD MG 1) MGD F low Capacity*** . . I ite Finn Capacity. ofpunipstation is dcfiucd as the maximum pumped flow' that can be achieved With the largest pump taken out 01service. Design Average Daily Flow is the firm capacity of the pinup station dixided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached fur each pu.nip station located between the project connection point and the WW'IfP where the Available Capacity is < O. Page 1 of 6 1TSE 08-13 boasStatement: i 'ilc a{Iaatit be peirm tta test c?t x F t aa'oject Caaas been rde �a•a��t�l pit°� taaat�ta�at IBC aaaaaa c@ �raat a°tax .a z a t iallent iaa tC taCa Etta tat? a �aa been I rt rnac. as < tra€Ctaaaa � t}a C ac¢a1 tt�EaC : as aaiCaakC aCaat�a; °I`Iais r°tiiaatita atlaC.aCia. kc� tCass its a C att a Et aC a,la as aat= a ,, 5 at aa3 as iaC a��3 ar a for w party, Page km .fib of Newton,. North USGS Tope Map Fig 1) 1305 NORTH CENTER STREE el HICKORY, NC 28601 lecture 828-322-2290 ! Dlnvironmental & laboratory Services towner CITY OF CONOVER Draing Title STREET LEVEL MAP Project Title CONOVER STATION II Dote 8/13/14 Job No, 041000.07 Olin, 11O•11111101110111, figC Sketch Reference W-201, eU-2E12 ject Location CONOVER STATION EXBT-2 August 13, 2014 NCDENR DNision of Water Resources Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Re: Conover Station fi Sewer Extension D&F Job Number: 041000.07 Dear Sir: The City of Conover is providing site improvements for Conover Station II, an infdl project associated with the rnultimodal facility. The existing site was formerly a 26.5 acre Broyhill Furniture Plant located just north of Hwy 70 SE on the west side of 3rd St. SE, Site Improvements are to include a paved parking lot new connector street, storm drainage, connection to existing public utilities, and a new 1 story building housing a new gym facility, and potentially a restaurant and a yogurt shop. This application is for the 314 LF extension of an existing 8" PVC gravity sewer. The new gravity sewer will serve the proposed building, with no future flows anticipated, The project will be competitively bid, and constructed by an insured general contractor, licensed in accordance with NC General Statutes. Very truly yours, DAVIS & FLOYD, INC, P. Scott Bell, PE Senior Project Manager Enclosures nia c:n/a Engineering Architecture Environmental I Laboratory 1073 139 Street SE Hickory, NC 28602-4165 [8281 322 2290 davisfloyd,corn r Number Progr itsCategoty Non-diseharge Permit Type Grayly Sewer Extension, Pump Stetsons, &'Pressure Sewer Extensions Primary Reviewer lames Tulle tar Ftu Parmitred Platy 9,400 Facia Facility Name Conover Station if Location Andress Own Central Files: APS Permit Tracking Stip tacus Active Version 1.00 Project Type New Projec Permit Classifeati i Individual', st Granted Affiliation Mn Facility C ntas la on 114 Region Mooresville County Catawba wvner Name City of Conover ntu °v,iter Type overrrent -Municipal Owner Affiliation rr r y A Clark Orig Issue 9/512014 Regulated Actl App Received Draft lnitlatetl 8/26/2014 citerlrrted (ranee astaurant Wastewater cr llection trt Cdailioncl Additional inform PO Box 549 (Conover rta 9/512014 alra rt rn+r sled N 2 61 054 Effective Expiration 9/5112014 body Nan trearraCnde r Number Ctrrrsnt C a Subbasin 67743 8480.00