Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0036004_Regional Office Historical File Pre 2018
NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor City of Hickory M±. Mick W. Berry, City Manager P.O. Box 398 Hickory,. N.C, 28603 Dear Mr. Berry: Division of Water Quality Charles Wakild, P. E. Dee Freeman Director Secretary June 21, 2012 Subject: Permit No. WQ0036004 29 North (Multi -Family Development) Wastewater Collection System Extension Catawba County, North Carolina In accordance with your application received onJune 14, 2012, we are forwarding herewith Permit No.WQ0036004, dated June 21, 2012 to the City of Hickory for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance -until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of :this permit and is therefore incorporated therein by reference. Please pay particular attention to Perrnit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 1.5A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A. NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria :for the Fast -Track Permitting of Purnp Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. it shall be the Perrnittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §1.43-215,6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, andfor referral of the North Carolina -licensed Professional Engineer to the licensing board. ape ThCarolina Aaturally Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 internal: mrirvv.nomwaterquality,ong Customer Service° 1-877-623-6748 An Equal Oppodunity/Affirmative Action Employer --50% Recycled/10% Post Consumer Paper Phone, (704) 663,-1699 Fax: (704) 663-6040 4V, Mr, Berry Page. 2 ..,'Lirre 21, 2012_ In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of :Hickory for the construction and operation of approximately 793 linear feet of 8-inch. gravity sewer and the discharge of 28,440 gallons per day of collected domestic wastewater into the Northeast treatment sewerage system, pursuant to the application received on june14, 2012, and in conformity with 15.A NCAC 2T; the Division's Gravity Sewer Minim.urn Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of the City of Hickory. The City of Hickory must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the %WIT' permitted limits and the WQCS00020 permit requirements. [he sewage and wastewater collected by this system shall be treated in The Northeast 'WWTP .(NPD.ES No.NC0020401) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days .following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Samar Bou-Ghazale at (704) :63-1699. Sincerely, for Charles Wakild, P.E. cc; Mooresville Regional Offi.ce, Collection System Permit File Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT (MODIFICATION) This permit shall be effective from the date of issuance until rescinded and shall be subject o the following specified conditions and limitations: This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data, 3. The wastewater collection facilities shall be properly maintained arid operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B 0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater coIection facilities to change ownership, or there is a name change of the Permittee, a forma i permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the Iife of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215,6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11, Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report Overflows and spills occurring outside normal business hours may also be reported to the Division, of Emergency Management at telephone number ( - or (919) -. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form - (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur, Part 11 f Form CS -SS (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Per issued this the 21E day of June, 2012 NORTH CAROLINA ENVIRONMENTAL ANAGEMENT COM SSION r r° haries Wakild, RE., Director Division of Water Quality By Authority of the Environmental Management Com Permit a hr* C; pti 6004 sion Fast Track Enginee Permit No, WQ0036004 June 21, 2012 Owner/W N TPMWCS City of Hickory P.© Box 398 Hickory, NC 28603 n Certification Paul J. Harrison, PE Bluewater Civil Design, LLC 19 Washington Park- Suite 100 Greenville SC 29601 Complete and submit this form to the permit issuing regional office with the followings • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Perm i modifications are required_for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION E Partial El Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (I periodically, Ij weekly„ El full time) the construction of 29 North (Multi -Family Development), a Catawba County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, USE THE TAB KEY TO MOVE FROM FIELD TO FIELD OwneriPermittee: la, Cif of Hickory Application Number: (to be completed by DWQ) Full Legal Name (company, municipality, HOA, utility, etc.) lb. Mick W Berri — City ri/lana_ger , — Signing Official Name and Title (Pease review 15A NCAC 2T .010 authorized signing officals) lc. The legal entity who will own this system is: 2 Ei Individual Federal Ej Municipality El State/County EI Private Partnership n Corporation [1 Other (specify)0 U. z z 0 —J O. • z 0 0 u_ ld PO Box 398 Mailing Address lf. NC State Zip Code lh 828-323-7427 1 828-322-1405 1jgreer@hckoryncgov Telephone Facsimile E-mail le. Hickory_ City lg. 28603 2. Project (Facility) Information: 2a 29 North (Multi -Family Development) 2b Catawba Brief Project Name (permit will refer to this name) County Where Project is Located 3. Contact Person: Paul J. Harrison, P E (Bluewater Civil Design, LLD) Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 864-735-5068 3c. paul@bluewaterciviLcom Phone Number E-mail 1, Project is New El Modification (of an existing permit) If Modification, Permit No.: 2. Owner is PI Public (skip to Item B(3)) 111 Private (go to item 2(a)) 2a, If private, applicant will be. 2b. If soldt facilities owned by a (must choose one) rj Retaining Ownership (i.e. store, church, single office, etc.) or Ej Leasing units (lots, townhomes, etc - skip to Item B(3)) r.1 Selling units (lots, townhomes, etc - go to item B(2b)) 3, City of Hickory rj Public Utility (Instruction C) [I] Homeowner Assoc /Developer (Instruction D) Owner of Wastewater Treatment Facility (VVVVTF) Treating Wastewater From This Project 4a. NORTHEAST VVWTP 4b. NC 0020401 Name of VVVVTF W1TF Permit No. 5a, CITY OF HICKORY 151o. 8 Gravity Sewer E Gravity 5c. Owner of Downstream Sewer Receiving Sewer Size i[i] Force Main Permit # of Downstream Sewer (Instruction E) 6. The origin of this wastewater is (check all that apply): Ej Residential Subdivision Apartments/Condominiums E] Mobile Home Park El School El Restaurant El Office [I] Retail (Stores, shopping centers) [1] Institution rttl Hospital [11 Church Ej Nursing Home El Other (specify) 7. Volume of wastewater to be allocated or permitted for this particular project': 2 44 *Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: 100 % Domestic/Commercial % Industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) % Other (specify). gallons per day Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line II Flow Inas already been allocated in Permit No. E] Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T 0303 to determine f a permit is required) 2/07 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for, the value in Item B(7) ANDIOR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7), Values other than that in 15A NCAC 2T ,0114 (b) and (c) must be supported with actual water or wastewater use! data in accordance with 15A NCAC .2T .0114 (f), (233) Total Bedrooms @, 120 GPD / Bedroom and (1) Clubhouse 480 GPD = 28,440 GPD (Total) 10. Summary of Sewer Lines to be Permitted (attach additional sheets tf necessary) Size (inches) Length (feet) 8 793 New Gravity or Additional Force Main New Gravity 1 Summary of Pump Stations w/ associated Force Mains to be Permitted attach additional sheets as necessary) Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow (MGD) 0 0 0 u. uJ th Operational Point. GPM 4iTDH Power Reliability Option 1 - permanent generator wIATS; Force Main Size Force Main Length 2 - portable generator WAITS Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow Power Reliability Option Operational Point (MGD) GPM @TDH 1 - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator wIATS; 2 - portable generator w/MTS Force Main Size Force Main Length 12, Will the wastewater flow in the proposed sewer linesor pump stations be able to be directed to another treatment facility? r] Yes Z No If Yes., permit number of 2" treatment facility (RO — if "yes.'' to B,12 please contact the Central Office PERCS Unit) 13_ Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? Z Yes 11 No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FIA,12107 i 14, Have the following permitsicertificafions been submitted for approval for the system or project to be served? Wetland/Stream Crossings - Genera( Permit or 401Certification? [1] Yes No [2] N/A Sedimentation and Erosion Control Plan? Yes LI No LI NA Storrnwater? Yes [1] No Lil N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or nterference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes. LI and provide details 1. OwneriPermittees Certification: (Signature of Signing Official and Project Name) 1, Mick W Berry , attest that this application for 29 North - City of Hickory_ has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note. In accordance with North Carolina General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any fa/se statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 1a, Signing Official Signature ) Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION, THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T ,0305 0 I— 2. Professional Engineer's Certification (Signature of Design Engineer and Project Name) Paul J. Harrison, P.E. attest that this application for 29 North (Multi -Family Development) has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria! for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump s, Stations and Force Mains adopted June 1_2000 and the watershed classification in accordance with Division guidance Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation, 2a Paul J. Harrison, P.E. Professional Engineer Name 2b. Bluewater Civil Design, LLC Engineering Firm 2c, 19 Washington Park - Suite 100 Mailing Address 2d., Greenville City CAR ••••.%.4s • — • . x-.•• t_S•Sio'•, C). -• • cr SEAL 1.7- ci- = 0 38371, ' tcsn, 2e. SC 2f 29601 ••• State Zip 29 864-735-5068 2h. 855-735-7350 2i pul@bluewatercivil.com Telephone Facsimile E-mail NC PE Seal, Signature Date FTA12/07 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE -IWO?) Project Applicant Name: City of Hickory Project Name for which flow is being requested: 29 North. More than one FIS E- I 0/ 07 ,nctv be required fOr a single pre#eci 'tithe owner c •,! WWTP is not responsible ji)r all pump stations along the route of the proposed wastewater flow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Northeast Waste Water Treatment Plant b. WWTP Facility Permit #: NC0020401 Ali flows are in MGD e. WWTP facility's permitted flow 6 MCA) d. Estimated obligated flow not yet tributary to the WWTP 0.192495 MCI) e. WWTP facility's actual avg. flow 3,175 MGD f. Total flow for this specific request 0.02844 MCD g, Total actual and obligated flows to the facility 3.395935 MGD h.. Percent of perrnitted flow used 5'7 % 11. Complete this section for each pump station you are responsible for along the route ofthis proposed wastewater flow, List pump stations located between the project connection point and the WWTP Pump Station Name 1-1 LI limn. Cove Approx. Capacity, MGD Approx. Current Avg. (Firm./Design) Daily Flow, MGD 0,240 MCI) 0.0225 MGD 111. Certification Statement: 1, Mick W. Berry., City Manage.7certify that, to the best of m' knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary/ sewer overflows or overburden any downstream pump station en route to the receiving :treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the hest available data. This certification applies to those items listed above in Sections 1 and 1.1 for which 1 am the responsible party. Signature of this form indicates acceptance o this wastewpter flow. Signing gificial Signal / 7 ate State of North Carolina Department of Environment and Natural Resources Division of Water Qua1iRy Flow Tracking/Aceptance for Sewer Extension Permit Applications (FIE —10/07) Project Applicant Name: City of Hickory ,Project Name for which flow is being, requested: 29 North more 117011 rine ITSE -10; 0 .be required for 41 single prnfeci ?: the owner (:?/ the es nor roponsibie fro- ail ( via( 10,7S ,;;110Vig ihe rowe (')1" the proposed ViYISIOWCaer17ow, I, Complete this section only if you are the ov of the Wastewater 11 ealment p a. WWTP Facility Name: Northeast Waste Water Treatment Plant b. WWTP Facility Permit .4: NC0020401 All flows are in M(jL) WWII) -facility's permitted flow 6 MG D d. Estimated obligated flow not yet tributa„ WWTP 0, I 92495 MG D e. WAVIP facility's actual avg. flow 3.175 MGD "Fotal flow for this specific request 0.02844 M(I) Total actual and obligated flows to the 'facility 3,395935 MCiD h. Percent of permitted flow used 57 0,10 11 (..T7omplete this section for each pump station you are responsible for along ti e routeot this — proposed wastewater flow. Lit pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity.. \IGD Approv Current Avg (Firm/Design) Daily Flow, M(iI) Huffman Cove 0.24 MGD 0,0225. MG[) 111 Certification Statement: I. Mick 'W. Berry. City ,N4anager, certify that., to the best of my knowledge, the addition of the \ (flume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not ,anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route: to the receiving treatment plant under normal circumstanc,es, This analysis has been performed in accordance with local established policies and procedures using the het available data, This certification applies to those items listed above in Sections I and II for which 1 am the responsible party Signature of this lom indicates acceptance othis wastew flow, Signing Oficial Signatre- ate 29 North (USGS Topographic Map) NOTES: BW# 2012-022 Vie, vea�. r 611 1112 4:38 PM Central APS SWP 06/20/12 Per ttttt Number 'k f, 0036004 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit. Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Individual Extensions Primary Reviewer Permit Contact Affiliation samar.bou-ghazale Coastal SW Rule Permitted Flow 28440 Facility Facility Name 29 North (Multi -Family Development) Location Address Owner Major/Minor Region Minor Mooresville County Catawba Facility Contact Affiliation Owner Name City of Hickory Dates/Events Owner Type Government - Municipal Owner Affiliation Mick Berry PO Box 398 Hickory Orig Issue 06/21/12 App Received 06/14/12 Regulated Activities Apartment complex Condominium Wastewater collection Outfall NULL body Name Draft Initiated Scheduled Issuance NC 286010398 Public Notice Issue Effective 06/21/12 06/21/12 Requested/Received Events Additional information requested Additional information received Stream Index Number Current Class Expiration Subbasin IA' HUG ES CO ERCIAL PROPERTIES, C. TO THE ORDER t9t: PO Box 10440 GREEMALLE, SC 29603 HAM I I Eg rld 01 0 r TO E3ANK, NATIONAL IJAL ASSOCIATION G EEN tILLE SC 29601 ET-i.3' Jun DATE AMOUNT T blue ciiL June 12, 2012 Plan Reviewer NCDENR Division of Water Quality - Mooresville Regional Office 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 RE: 29 North - Multi -Family Development "Fast Track Sanitary Sewer Extension Submittal Package" Hickory, NC To Whom it May Concern, Please find the attached Engineering Plans a Specifications for purposes of permitting the public sanitary sewer system for the above referenced project. I have detailed out the submittal documents below for your use. Please feel free to contact me (paui@bluewatercivil.com or 864-735-5068) if you have any comments or questions concerning this submittal. Regards„ Bluewater Civil, esign, PLLC Paul. J. Harrison, P.E., LEEO® AP Partner Items Included With Submittal • (1) transmittal letter (This Document) • (1) original Fr (1) copy of the application form • (1) $480.00 check (Application Fee) • (1) copy of the signed FORM FTSE-10/07 • (1) 8.5"X11" USGS Topographic Map Showing the Project Delineation and closest surface waters • Certifications on the application BLUEWATER CIVIL DESIGN, PLLC • 19 Washington Park - Suite 100 • Greenville, SC 29601 (864) 735-5068 • i*),:?:',biLif',,,,,,,aterciviLcorrp • www,htuewaterciviLcom Fast Track Engineering Certification Permit No, WQ0036004 June 21, 2012 OwnerIWWTP/WQCS City of Hickory P.O Box 398 Hickory, NC 28603 Paul J. Harrison, PE Bluewater Civil Design, LLC 19 Washington Park- Suite 100 Greenville SC 29601 Complete and submit this form to the permit Issuing regional office with the following; One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are reguil'ed for any changes resulting in non-compliance with this permit regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION El Partial EX Final 4-tA a , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ( periodically, 0 weekly, © full time) the construction of 29 North (Multi -Family Development), a Cataw a County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: 11.110/1. E A L 3637a .. SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE. SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is respepsibl d'rtracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions.