Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0088366_Inspection_20100615
A47,4 NCDENR North Carolina Department of Environment and, Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary June 15, 2010 Harnett County Utilities Attn: Steve Ward, Director P.O. Box 1119 Lillington, NC 27546 SUBJECT: June 11, 2010 Compliance Evaluation Inspection Harnett County Utilities South Harnett Regional WWTP Permit No: NC0088366 Harnett County Dear Mr. Ward: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on June 11, 2010. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Chemist, of the Fayetteville Regional Office. The cooperation of Mr. Kenny Fail, Grade IV ORC, was greatly appreciated. The facility was found to be in Compliance with permit NC0088366. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance: Comments • " Facility was clean and neat in appearance at the time of the inspection. All records and logbooks are very well kept. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3327. Sincerely, Mail; Brantleyi Environmental Chemist Surface Water Protection Section Fayetteville Regional Office cc: Kenneth Wayne Fail, ORC Central Files• y tte„uille�Fi es (k`m�b)� NorthCarolina Naturally North Carolina Division of Water Quality/Aquifer Protection Section 225 Green St./ Suite 714 Fayetteville, NC 28301 Phone (910) 433-3300 FAX (910) 486-0707 Internet: h2o.enr.state.nc.us Customer Service 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper United States Environmental Protection Agency E P n/y Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data•System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 INI 2 I5I 31 NC0088366 111 121 10/06/11 117 Type Inspector Fac Type • 18ICI 19ISI 20I II 1 1 1 1 1 1 I 1 I 1 1 1 1 1 1 166 Remarks 21 1 1 1 1 1 1 1 1 1 1 1 1 I I I 1 I 1 I I 1 1 1 I I I 1 1 I 1 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 169 70 13 I 71 I N I 721 NI 73 I I 174 75I I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) South Harnett Regional WWTP PO Box 1119 Lillington NC 275461119 Entry Time/Date 09:30 AM 10/06/11 Permit Effective Date 10/05/01 Exit Time/Date 11:40 AM 10/06/11 Permit Expiration Date 11/05/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Kenneth Wayne Fail/ORC/910-897-5022/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Kenneth Wayne Fail,PO Box 1119 Lillington NC 275461119//910-897-5022/No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit ■ Flow Measurement • Operations & Maintenance • Records/Reports Self -Monitoring Program • Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) . Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Mark Brantley FRO WQ//910-433-3300 Ext.727/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Belinda S Henson ed./4/; , 9 .r) FRO WQ//910-433-3300 Ext. 4 / Date C 6N - I $ -- / EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 2 3 111 12 17 I NI i 5I 1 NC0088366 1 10/06/11 1 Type Inspector Fac Type 18 19 20 ICI I sl � 1 I IIII IIII I 1 I I 1 I 166 Remarks 291III IIII IIII III IIIII IIII I I I 1 I I I Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 1 69 7° 1 31 711 NI 721 N 1 731 1 1 74 751 1 1 1 1 1 1 1 80 Section B: , Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) South Harnett Regional WWTP PO Box 1119 Lillington NC 275461119 Entry Time/Date 09:30 AM 10/06/11 Permit Effective Date 10/05/01 Exit Time/Date 11:40 AM 10/06/11 Permit Expiration Date 11/05/31 Name(s) of Onsite Repreentative(s)/Titles(s)/Phone and Fax Number(s) /// Kenneth Wayne Fail/ORC/910-897-5022/ Other Facility Data . Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Kenneth Wayne Fail,P0 Box 1119 Lillington NC 275461119//910-897-5022/No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit • Flow Measurement • Operations & Maintenance Records/Reports Self -Monitoring Program • Facility Site Review • Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Mark Brantley FRO WQ//910-433-3300 Ext.727/ \ j ✓''(s t 6 -/5"- /n Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Belinda S Henson 6.NYC 1, -) FRO WQ//910-433-3300 Ext.- Date I O 4/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yr/mo/day Inspection Type NC0088366 ' I11 12I 10/06/11 I17 181 CI' 1 Section D: Summary of'Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Facility was clean and neat in appearance at the time of the inspection. All records and logbooks appear to be very well kept. v Page # 2 • Permit: NC0088366 Owner - Facility: South Harnett Regional WWTP Inspection Date: 06/11/2010 Inspection Type: Compliance Evaluation S. Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Yes No NA NE ■nnn Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ n n n Judge, and other that are applicable? Comment: Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Yes No NA NE n n■n ■ nnn n n•n ■ nnn ■ nnn Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn ■nnn ■ ■ ■ ■ ■ nnn n nn■ ■ nnn ■ nnn ■ nnn ■ nnn. ■ nnn Page # 3 Permit: NC0088366 Owner - Facility: South Harnett Regional WWTP Inspection Date: 06/11/2010 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ n n n Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ n ❑ n Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less): Has the permittee submitted a new application? n n ® n Is the facility as described in the permit? ® n n n # Are there any special conditions for the permit? n n ® n Is access to the plant site restricted to the general public? ® n n n Is the inspector granted access to all areas for inspection? ■ n n ❑ Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ n n n Is all required information readily available, complete and current? ■ n n n Are all records maintained for 3 years (lab. reg. required 5 years)? ■ n n n Are analytical results consistent with data reported on DMRs? W n n n Is the chain -of -custody complete? , ®n n n Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses. • Transported COCs Are DMRs complete: do they include all permit parameters? ® n n' n Has the facility submitted its annual compliance report to users and DWQ? nnnai (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? ®n n n Is the ORC visitation log available and. current? ® n n n Is the ORC certified at grade equal to or higher than the facility classification? ® n n n Is the backup operator certified at one grade less or greater than the facility classification? © n n n Is a copy of the current NPDES permit available on site? ®n n El Page # 3 10 Permit: NC0088366 Owner - Facility: South Harnett Regional WWTP Inspection Date: 06/11/2010 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? 0 n n ■ Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? • ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ■ ❑ rl fl If effluent (diffuser pipes are required) are they operating properly? ❑ n ■ ❑ Comment: Flow Measurement - Effluent Yes No 'NA NE # Is flow meter used for reporting? - ■ n fl n Is flow meter calibrated annually? • ❑ 0 n Is the flow meter operational? ■ ❑ ❑ ❑' (If units are separated) Does the chart recorder match the flow meter? n El • El Comment: Flow meter was last calibrated in October 2009. .Bar Screens Yes No NA NE Type of bar screen a.Manual 11 b.Mechanical ■ Are the bars adequately screening debris? ■ Q n ❑ Is the screen free of excessive debris? ■ ❑ ❑ ❑ Is disposal of screening in compliance? • n ❑ n Is the unit in good condition? • n n n Comment: Grit Removal Yes No NA NE Type of grit removal a.Manual n b.Mechanical ■ Is the grit free of excessive organic matter? • n n n Is the grit free of excessive odor? • ❑ ❑ n # Is disposal of grit in compliance? • n n Q Comment: Page # 4 Permit: NC0088366 Owner - Facility: South Harnett Regional VWVTP Inspection Date: 06/11/2010 Inspection Type: Compliance Evaluation Sequencing Batch Reactors Type of operation: Is the reactor effluent free of solids? Does minimum fill time correspond to the peak hour flow rate of the facility? Is aeration and mixing cycled on and off during fill? The operator understands and can explain the process? Comment: Filtration (High Rate Tertiary) Type of operation: Is the filter media present? Is the filter surface free of clogging? Is the filter free of growth? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids and filter media? Comment: Disinfection - UV Are extra UV bulbs available on site? Are UV bulbs clean? Is UV intensity adequate? Is transmittance at or above designed level? Is there a backup system on site? Is effluent clear and free of solids? Comment: Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Yes No NA NE Duplex ■ nnn nnn■ ■ nnn ■ nnn- Yes No NA NE Up flow ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn, Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn W HEW Ennn Yes No NA NE Ennn ■ nnn ■ nnn n nn■ ■ nnn n nn■ Page # 5 v. ▪ Permit: NC0088366 Owner - Facility: South Harnett Regional WWTP Inspection Date: 06/11/2010 Inspection Type: Compliance Evaluation Sequencing Batch Reactors Type of operation: Is the reactor effluent free of solids? Does minimum fill time correspond to the peak hour flow rate of the. facility? Is aeration and mixing cycled on and off during fill? The operator understands and can explain the process? Comment: Filtration (High Rate Tertiary) Type of operation: Is the filter media present? Is the filter surface free of clogging? Is the filter free of growth? Is the air scour operational? Is_the scouring acceptable? Is the clear well free of excessive solids and filter media? Comment: Disinfection - UV Are extra UV bulbs available on site? Are UV bulbs clean? Is UV intensity adequate? Is transmittance at or above designed level?, Is there a backup system on site? Is effluent clear and free of solids? Comment: Standby Power Is automatically activated standby power available? Is the generator -tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? - Is there an emergency agreement with a fuel vendor for extended run on back-up power? Yes No NA NE Duplex ■ nnn nnn■ ■ nnn ■ nnn Yes No NA NE Up flow ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ®nnn Yes No NA NE ® nnn ®nnn ■ nnn ■ nnn n n®n ®nnn Yes No NA NE ®nnn ®nnn e nnn n nn■ ® nnn n nn■ Page # 5 Permit: NC0088366 Owner - Facility: South Harnett Regional WWTP Inspection Date: 06/11/2010 Inspection Type: Compliance Evaluation Standby Power Yes No NA NE Is thegenerator fuel level monitored? ■ n n Comment: Influent Sampling Yes No NA NE # Is composite sampling flow proportional? fl ❑ ot n Is sample collected above side.streams? ■ n n Is proper volume collected? ■ .n n . n Is the tubing clean? ■ n n n # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Ei n n n Is sampling performed according to the permit? ■ ❑ ❑ ❑ - Comment: Temperature was at 6 degrees celsius. Effluent Sampling Yes No NA NE Is composite sampling flow proportional?- ■ ❑ n n Is sample collected below all treatment units?, ■ n ❑ n Is proper volume collected? _ ■ n fn n Is the tubing clean? • ❑ n n # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ n n n Is the facility sampling performed:as required by the permit (frequency, sampling type representative)? ilo n n n Comment: Effluent sampe temp was at 4 degrees celsius. Upstream / Downstream Sampling ices No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)?..n fn Comment: Facility is a member of the Middle Cape Fear Basin Association. ■n Page # 6