Loading...
HomeMy WebLinkAboutWQ0029196_Regional Office Historical File Pre 20187,, Michael F. Easlev„ Governor William G. Ross Jr.„ Secietary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality August 19, 2005 Mr, Eddie Faulkner, Director of Public Works Town of Maiden 113 W. Main Street Maiden, NC 28650 Subject: Permit No. WQ0029196 Town of Maiden Propst Sewer Line Wastewater Collection System Extension Town of Maiden Catawba County, North Carolina Dear Mr. Faulkner: In accordance with your application received on August 3, 2005, we are forwarding herewith Permit No. WQ0029196, dated August 19, 2005, to the Town of Maiden for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules, Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. 1,•Pitri Carolina Aaturally Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet h2o.entstatemc „US Customer Service. 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycied/10% Post Consu Mr, Faulkner Page 2 August 19, 2005 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, perrnission is hereby granted to the Town of Maiden for the construction and operation of approximately 2,652 linear feet of 8-inch gravity sewer as part of the Town of Maiden Propst Sewer Line project, and the discharge of 8,160 gallons per day of collected domestic wastewater into the Town of Maiden existing sewerage system, pursuant to the application received August 3, 2005, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Town of Maiden WWTP (NPDES No. NC0039594) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, rNSA for Alan W. Klimek, P.E. cc: Catawba County Health Department Mooresville Regional Office, Surface Water Protection (WWTP Permit No, NC0039594) Richard Anderson, HSMM Inc. Surface Water Protection Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system perrnit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H ,0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. "12%tatienz2itiliVvs!NV,-Nim. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Perrnittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215,6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Perrnittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 28 .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 28 .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Perrnittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part. II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 19th day of August, 2005. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for AlanW. Klimek, P.E., rector Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0029196 T-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 0 0 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed DWQ) 1f;L-cl 1. Owner la, Town of Maiden Full Legal Name (company, municipality, HOA, utility, etc.) lb. Eddie Faulkner, Director of Public Works Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) lc, The legal entity who will own this system is: 0 Individual 0 Federal Municipality 0 State/County El Private Partnership 0 Corporation 0 Othe ld. 113 W. Main Street le, Maiden Mailing Address City if North Carolina lg, 28650 State 1h. (828) 428-5006 (828) 428-5017 Telephone Fac-simile 2, Project (Faci)ity) Information' —I 2a. Town of Maiden Propst Sewer Line a. Brief Project Name (permit will refer to this name) 'CC 3. Contact Person. .ce 3a, Richard Anderson, P,E„ Engineer for the Town of Maiden Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (864) 597-0580 3c, randerson@hsrnm,com Phone Number E-mail Zip Code 1j. E-mail 2b. Catawba County Where Project is Located s ci 1 Project is New El Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit 2. Owner is Z Public (skip to Item B(3)) El Private (go to item 2(a)) 2a. If private, applicant will be: 2b if sold, facilities owned by a (must choose one 0 Retaining Ownership (i,e, store, church, single office, etc.) or 0 Public Utility (Instruction III) 2 0 Leasing units (lots, townhomes, etc, - skip to Item B(3)) 0 Homeowner Assoc,/Developer (Instruction IV) 0 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) ..... 3, Town of Maiden Owner of Wastewater Treatment Facility (WAITE) Treating Wastewater From This Project cxi 2 et 4a. Town of Maiden VVWTP 4b, NC0039594 Name of WWTF VWVTF' Permit No. I 0 5a. N/A -.51q. 0 Gravity 5c. ' Z Owner of Downstream Sewer Receiving Sewer Size ,0 Force Main Permit Number of Downstream Sewer (if known , I.- 6. The origin of this wastewater is (check all that apply): Z Residential Subdivision 0 Car Wash 0 Apartments/Condominiums 0 Institution 0 Mobile Home Park El Hospital 0 School 0 Church 0 Restaurant 0 Nursing Home 0 Office Ej Other (specify): 7. Volume of wastewater to be allocated for this particular project: 8,160. gallons per day *Do not include previously permitted allocations 8. If the permitted flow is zero, indicate why: Interceptor Line - Flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No, 0 Rehabilitation or replacement of existing sewer with no new flow expected % Domestic/Commercial % Industrial % Other (specify): FTA 02/03 - Rev. 3 04/05 „ ST-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS„AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H ,0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3), 17 residences at 480 gpd each (4 bedrooms 120 gpd/bedroom) 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8 Gravity or Force Main (use the pull down menu) 2,652 Gravity ENTER TOTAL LINE LENGTH IN MILES 4,3 0 1 Summary of Pump Stations to be Permitted (attach additional sheets as necessary) re 0 z u_ Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (I- dual line feed; 2- permanent generator WATS; 3- plans for cross-reference) (MGD) GPM TDH portable generator w/telemetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Yes 0 No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes 0 No Sedimentation and Erosion Control Plan? Ej Yes No Stormwater? El Yes 0 No 14, Does this project involve aerial lines or siphons? Check if yes: El These lines will be considered high priority and must be checked once every six months 15. Does this project have gravity sewer lines designed at minimum slopes? Be aware that the Division will not accept installed lines more than 10% flatter than the minimum siope Lines instalted outside this tolerance should be corrected prior to submitting the final engineering certification. N/A N/A N/A FTA 02/03 - Rev. 3 04/05 PrST-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: LI A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, El A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody, z 0 z 0 Location ID on Map (self chosen - as shown on map for cross-reference) OFEk 7r1.) Name of Waterbody Un-named Tnbutary to Maiden Creek County Catawba Waterbody Stream Waterbody River Basin Index Classification Catawba 11-129-5-7-2-(3) Submit the 85" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: 1, 7-'eld Ci"rk „ attest that this application for Town of Maiden Propose Sewer Line has been reviewed by me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete, Note: In accordance with North Carolina General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be 9u111y of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $2 0 r OffiCia Signature 2. Professional Engineer's Certification: I attest that this application for Town of Maiden Propose Sewer Line has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this materialand have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215„6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Richard Anderson Professional Engineer Name 2b, HSMM. Inc. Engineering Firm 2c, 1460 John 8. White,Sr,Blvd Mailing Address 2d, Spartanburg City 2g. (864) 597-0580 2h. (864) 597-0583 Telephone Facsimile 2e, SC 2f 29306 State Zip 21 rande nthsmrn.com E-mail Seal, Signature & Date 1TA 02/0.3 Rev, 3 04/05 Permit Numb Program Category Non -discharge Permit Type Gravity Serer Extension, Pump Static ns, Pressure Server Individual 0029196 Central Files:APS PermitTracking Slip Extensions Primary Reviewer d e.browder Permitted Flow Faeitity Facility Name Town of Maiden Propst Sewer Line Location Address vvner Name Town of Maiden Events Orly Issue Apt) Received 08/03/05 leauled Activities Duffel! IUL' Waterbady Name status In review Version Permit Contact ,Affiliation Project Type New Project Permit Classification Major/Pwl9inr Region Minor Mooresville County Catawba Facility Contect Affiliation Scheduled t Initiated Issuance s am In Owner Type Government- Municipal 08 Owner Affiliation Todd Clark, Manager Town PO Box 125 Maiden Public Notice issu fiber NC Effective Additional orrn rt requested Additional information received Cure s Expiration subbasin August l , 2005 T.0 Department of Fnvirc>intet� & Natural Resources DWQ Non -Discharge Penn ittin . Mooresville Regional Office 610 E. Center Ave. Suite 301 Mooresville. NCarolina 2i Re: ei Propt Sewer Gidon, Ni.. Commission No. 60726.11 Dear Sir or Madam.: Enclosed. please find a Fast Track pplicaGravity Sewers, Pump Stations, and Force is package for Town of Maiden Props t ewer Line. Included is the application form, a ck for S400.00 dollars for the application fee, and a USGS map. li you have any comments ~r uetiotis concerning this smitta, please do not l esitate to contact inc at _597-05 0. Si c Richard And Project Mana! enclosures; as noted Copieo: Mr. Eddie Faulkner,'"I o n cat l+laiden Project File